You are on page 1of 11

Chair Swivel Durability

Tester
Operation Manual
(Please do read this manual carefully before operation)

(Warning: Always use a transformer to convert your 110V AC to 220V AC

for power supply)

锦辉试验设备制造厂
Kingwells Test Equipment Mfg., Ltd.
Preface

Thank you for purchasing our equipment. We provide not only good quality products but also
reliable after sale service.

This manual is for use of operators of this equipment. It is highly recommended that the
operators to read and understand this manual before operating the equipment with special
attention to warnings and cautions. The manual details the working principles, construction
and features, operation instruction and maintenance of the equipment. Those texts “Test
Specified” or “Standard” mentioned in this manual are for reference only, please cross check
with relevant standards or data for correct information.

Contents

一、Working Principles‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥1
二、Construction and Features ‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥1
三、Operation Instructions‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥1-5
四、Installation and Handling ‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥6
五、 Cautions and Maintenance‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥ 6
六、Technical Specifications‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥‥6-7
1 Working Principles:
KW-BFM-09 Chair Swivel Durability Tester is a model of test equipment which adopts integrated
and digital control technology. It contains 2 parts: electrical and mechanical systems. The electrical
system is comprised of touch screen, PLC and other electrical parts, easy to operate; The mechanical
system uses a cylinder to apply the test load on seating surface, and the positive/negative electric
motor drives the plate (where chair sample is secured on) rotating as standard specifies. It applies
widely to office chairs and other furniture tests.

2 Construction Features

Cylinder

Force Meter

Control box

Manual pressure
regulating valve

Motor (MPRV) and hand


valve (HV)

Loading Pad

Fixing
bolts
Force applying mechanism can

move frontward/backward by
loosing this knob

Fig. 1

1
2 Operation Instructions

2.1 Test Sample Clamping

2.1.1 Adjust the positions of the fixing bolts on Chair Center Locating Template (CCLP) and place
the chair base in between the bolts, then turn clockwise the inner circle of the CCLP so that each two
neighboring bolts can clamp the legs tightly. (Fig 2)

Turn clockwise
to clamp legs

Fig.2

2.1.2 When the base is fixed, turn left the knob of Manual Pressure Regulating Valve (MPRV) to
discharge the air pressure, then press down the Hand Valve (HV) and turn right the knob of MPRV
until specified force value is attained (the force value is displayed from the Force Meter which is
installed at top right of the body. (see Fig.3)

2
Force Meter

MPRV and HV

Fig.3

2.2 How to operate Control Box:

2.2.1Turn on the power switch at back of control box, wait 5 – 10 seconds then enter system interface.
(Fig 4)

3
Click to
Enter

Fig.4

2.2.2 Click OK and come to Access Input (Fig 5). Key in number “1”for Operator Account and “123456”for
Operator Password (original and changeable), then press “Confirm” to enter Work Mode Options. (Fig.
6)

点击输入密码

图5

4
点击进入

图6
2.2.3 Select the work mode and click “OK” to enter and set up, or click RETURN to
go back to previous page, see Fig. 7

Fig. 7

2.2.3.1 Single Direction Swivel Control Mode Setting – Fig. 8

Swivel Cycles Set: key in cycle number required


Current Cycles: display cycles accomplished. To reset, press and hold the number 3
seconds. Touch “START” and hold for 3 seconds to operate test.
5
RPM: Shall display only one minute after the machine starts running or the Speed Knob
is adjusted.

Click and key in numbers

Reset by holding for 3 Sec.

Click to enter the other mode

Fig.8

2.2.3.2 Bi- Directional Swivel Setting(Fig.9):

Angle Rotating

减速角度

Reset for
new test

Min. setting 0.5

Click to enter the other mode 图9

6
3 How to shut off the machine

3.1 To shut off the machine, press red button STOP, and snap the hand valve upward to
discharge the load, then shut off the power switch at back of control box, lastly turn off
the air source.
3.2 To guarantee the lifetime, ensure to shut off the power and air source when not in use.

4.Installation and Handling:

4.1 Ensure not to be struck or turned over during handling.


4.2 Installation:
4.2.1 When the machine is moved to installation location, adjust the screws on wheels to
ensure the machine stands firmly and horizontally.
4.2.2 Power Supply: AC 220V,50 Hz. 10A
(Must use transformer to convert your 110V AC to 220V AC)
Danger: Ensure supply voltage within ±10% of nominal and be properly grounded to avoid
hazards due to electricity leakage

4.2.3 Environmental Condition: 10℃~35℃,RH ≦80%.

Warning: Keep the machine far from magnetic field, corrosive and shaking environment.

5. Cautions and Maintenance

5.1 Cautions:

5.1.1 The force output of cylinder has been calibrated.


5.1.2 Strictly follow requirements for proper power connection.
5.1.3 Operators shall read and understand sufficiently the operation and maintenance of this
equipment before use.
5.1.4 The control and display system of this equipment is precise parts, so it is highly
recommended to use individual power source, and avoid external interference.
5.1.5 Install the machine in a clean and dry location.
5.1.6 Avoid damage when it is moved to other location.
5.1.7 Periodically check the transmission device and adjust if found loose.
5.1.8 Recommend for periodical calibration to ensure accuracy of main and critical parts.
5.1.9 Compressed air source must be filtrated and dried to avoid damage to pneumatic
components.
7
5.2 Maintenance:

5.2.1 Regularly clean platform surface。


5.2.2 Clean the electroplating surface with engine oil to keep shiny and avoid rusted.
5.2.3 Regularly lubricate those wear parts using grease (add in a small amount of engine oil
5.2.4 Never clean the control box panel with wet cloth to avoid damage to IC parts.
5.2.5 All fixtures must be properly used and kept, and regularly maintained with anti – rusting
oil.

6. Technical Specifications:

ANSI/BIFMA X5.1- 2011 09


Application
BS EN 1335-3:2009 7.3.3

Test Object All kinds of seating with swivel function

Separate Control Box


Touch Screen Panel + PLC with memory at power failure
Control System
function
RMP display and Self-checking
Rotation Frequency:1~15RPM adjustable
Rotating Angle: Clockwise, counter-clockwise, or
o
360 counter-rotation
Output Force: 150Kg
Parameters
Cylinder Stroke: 500mm
Counter range: 0~999999
Loading height for Seating surface: 350~800mm
Turn Plate Dia.: 800mm

Air Pressure:≥0.5MPa
Air Source Air Flow:≥800L/min
Air must be filtrated and dried

Power Supply Single Phase 220V/50Hz/10A

External Size 1200x1360x1680mm (L x W x H)

Weight 212 KGS


Chair Center Locating Template KW-BFM-06: 1 set
Accessories
Loading Pad with universal joint: 1 set

8
Special Statements:
1. We are committed to continuous improvement and upgrade of our products, so the real equipment
prevail this manual (description, figures or illustrations) if you find there is difference between them.

2. Those texts “Test Specified” or “Standard” mentioned in this manual are for reference only, please cross
check with relevant standards or data for correct information

3. This manual shall not be used as basis for any requests from Kingwells.

4. Final rights of interpretation of this manual belong to Kingwells.

Please call us or send written messages if you have any inquiries, our engineers always
Stand by to provide professionals technical support.

东莞市锦辉试验设备制造厂
Kingwells Test Equipment Mfg.,Ltd.
地址:广东省东莞市南城区白马方屋氹村 1 巷 1 号
电话: 86-769-22906728
传真: 86-769-22909619
Web: www.kingwells.com
Kingwells E-Mail: info@kingwells.com

You might also like