A digitalized system to combine multiple services.
Flexible distributed structure and expansion which supports maximum 192 Digital Piont Units (DPUs) with single DAU and 16 DEUs with combination of star and cascaded connection. Hybrid-fiber for DEU&DPU connection, remote power supply supported. (Optional) Integrated delay adjustment feature. Support Gigabit ethernet backhaul. Built-in LTE modem for remote controlling and monitoring. Meet 3GPP standards. DPU can support 4 bands 2*2 MIMO or 1 band 4*4 MIMO and 2 bands 2*2 MIMO. Two types of DPU: DPU with integrated Omni antenna, DPU with individual single band ports for external antennas.
Information contained in this document is subject to confirmation at time of ordering. Page 1 of 3 Specifications may differ depending on region and customers’ requirements. DS-Control: 0-0-3 / 0319 ComFlex Pro Low Power DAS Specifications System 700MHz, 800E MHz, 850MHz, 900MHz, 1800MHz, 1900MHz, EAWS, 2100MHz, System 2300MHz, 2600MHz (FDD), 2600MHz (TDD), Optical Fiber Single Mode Optical Wavelength nm 1270/1330 Maximum Communication Distance km DAU-DEU: 10km; DEU-DEU:2km; DEU-DPU:0.3km Data Rate Gb/s 12.5
Electrical 700 800E 850 900 1800
Operating Frequency, Uplink MHz 703-748 832-862 824-849 880-915 1710-1785 Operating MHz 758-803 791-821 869-894 925-960 1805-1880 Frequency, Downlink Operating Bandwidth Per Sub-band MHz Max 45 Max 30 Max 25 Max 35 75 Total Output Power, Uplink dBm -5 700/ 800/ 850/ 900: 17 Total Output Power, Downlink dBm 1800: 21 Maximum System Gain dB 700/ 800/ 850/ 900: 24, 1800: 28 Attenuation Adjustment Range dB DAU: 0-30, DPU: 0-20 (1dB step) Pass Band Ripple, p-p dB 3 Uplink Noise Figure dB 10 System Group Delay sec 8 Spurious Emission dBm 3GPP TS 36.106 Absolute Maximum RF Input Power dBm Uplink: -10dBm; Downlink: +10dBm; Antenna Integrated Antenna Impedance 50
Electrical 1900 EAWS 2100 2300 2600 FDD 2600 TDD
Operating Frequency, Uplink MHz 1850-1915 1710-1780 1920-1980 2500-2570 Operating 2300-2400 2570-2620 MHz 1930-1995 2110-2180 2110-2170 2620-2690 Frequency, Downlink Operating Bandwidth Per Sub-band MHz Max 65 Max 70 Max 60 Max 80 Max 70 Max 50 Total Output Power, Uplink dBm -5 Total Output Power, Downlink dBm 21 Maximum System Gain dB 28 Attenuation Adjustment Range dB DAU: 0-30, DPU: 0-20 (1dB step) Pass Band Ripple, p-p dB 3 Uplink Noise Figure dB 10 System Group Delay sec 8 Spurious Emission dBm 3GPP TS 36.106 Absolute Maximum RF Input Power dBm Uplink: -10dBm; Downlink: +10dBm; Antenna Integrated Antenna or external antenna (8 ports) Impedance 50
Information contained in this document is subject to confirmation at time of ordering. Page 2 of 3 Specifications may differ depending on region and customers’ requirements. DS-Control: 0-0-3 / 0319 ComFlex Pro Low Power DAS Power, Mechanical & Environmental DAU 88 x 485 x 400 Dimensions, DEU mm 88 x 485 x 360 H x W x D (approx.) DPU 62 x250x 250 DAU 13 Weight (approx.) DEU Kg 18 DPU 3.5 DAU DC48 /AC100~240V VAC Power Supply DEU AC100~240V DPU VDC Supplied by DEU/DC48V DAU 130 Power Consumption DEU W 70 (approx.) DPU 65 DAU Cluster RF connector, simplex RF Connectors DEU / DPU SMA-Female (External antenna version) DAU -10~+45 Operating Temperature DEU C -10~+45 DPU -10~+45 DAU IP Level DEU IP30 DPU
Information contained in this document is subject to confirmation at time of ordering. Page 3 of 3 Specifications may differ depending on region and customers’ requirements. DS-Control: 0-0-3 / 0319 ComFlex Pro Low Power DAS