You are on page 1of 3

ComFlex Series Distributed Access System

ComFlex Pro Low Power DAS


Features

 A digitalized system to combine multiple services.


 Flexible distributed structure and expansion which supports maximum 192 Digital Piont
Units (DPUs) with single DAU and 16 DEUs with combination of star and cascaded
connection.
 Hybrid-fiber for DEU&DPU connection, remote power supply supported. (Optional)
 Integrated delay adjustment feature.
 Support Gigabit ethernet backhaul.
 Built-in LTE modem for remote controlling and monitoring.
 Meet 3GPP standards.
 DPU can support 4 bands 2*2 MIMO or 1 band 4*4 MIMO and 2 bands 2*2 MIMO.
 Two types of DPU: DPU with integrated Omni antenna, DPU with individual single
band ports for external antennas.

Functional Block Diagram

© 2019 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 1 of 3
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-3 / 0319
ComFlex Pro Low Power DAS
Specifications
System
700MHz, 800E MHz, 850MHz, 900MHz, 1800MHz, 1900MHz, EAWS, 2100MHz,
System
2300MHz, 2600MHz (FDD), 2600MHz (TDD),
Optical Fiber Single Mode
Optical Wavelength nm 1270/1330
Maximum Communication Distance km DAU-DEU: 10km; DEU-DEU:2km; DEU-DPU:0.3km
Data Rate Gb/s 12.5

Electrical 700 800E 850 900 1800


Operating Frequency, Uplink MHz 703-748 832-862 824-849 880-915 1710-1785
Operating
MHz 758-803 791-821 869-894 925-960 1805-1880
Frequency, Downlink
Operating Bandwidth Per Sub-band MHz Max 45 Max 30 Max 25 Max 35 75
Total Output Power, Uplink dBm -5
700/ 800/ 850/ 900: 17
Total Output Power, Downlink dBm
1800: 21
Maximum System Gain dB 700/ 800/ 850/ 900: 24, 1800: 28
Attenuation Adjustment Range
dB DAU: 0-30, DPU: 0-20
(1dB step)
Pass Band Ripple, p-p dB 3
Uplink Noise Figure dB 10
System Group Delay sec 8
Spurious Emission dBm 3GPP TS 36.106
Absolute Maximum RF Input Power dBm Uplink: -10dBm; Downlink: +10dBm;
Antenna Integrated Antenna
Impedance  50

Electrical 1900 EAWS 2100 2300 2600 FDD 2600 TDD


Operating Frequency, Uplink MHz 1850-1915 1710-1780 1920-1980 2500-2570
Operating 2300-2400 2570-2620
MHz 1930-1995 2110-2180 2110-2170 2620-2690
Frequency, Downlink
Operating Bandwidth Per Sub-band MHz Max 65 Max 70 Max 60 Max 80 Max 70 Max 50
Total Output Power, Uplink dBm -5
Total Output Power, Downlink dBm 21
Maximum System Gain dB 28
Attenuation Adjustment Range
dB DAU: 0-30, DPU: 0-20
(1dB step)
Pass Band Ripple, p-p dB 3
Uplink Noise Figure dB 10
System Group Delay sec 8
Spurious Emission dBm 3GPP TS 36.106
Absolute Maximum RF Input Power dBm Uplink: -10dBm; Downlink: +10dBm;
Antenna Integrated Antenna or external antenna (8 ports)
Impedance  50

© 2019 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 2 of 3
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-3 / 0319
ComFlex Pro Low Power DAS
Power, Mechanical & Environmental
DAU 88 x 485 x 400
Dimensions,
DEU mm 88 x 485 x 360
H x W x D (approx.)
DPU 62 x250x 250
DAU 13
Weight (approx.) DEU Kg 18
DPU 3.5
DAU DC48 /AC100~240V
VAC
Power Supply DEU AC100~240V
DPU VDC Supplied by DEU/DC48V
DAU 130
Power Consumption
DEU W 70
(approx.)
DPU 65
DAU Cluster RF connector, simplex
RF Connectors DEU /
DPU SMA-Female (External antenna version)
DAU -10~+45
Operating Temperature DEU C -10~+45
DPU -10~+45
DAU
IP Level DEU IP30
DPU

© 2019 Comba Telecom. All rights reserved


Information contained in this document is subject to confirmation at time of ordering.
Page 3 of 3
Specifications may differ depending on region and customers’ requirements.
DS-Control: 0-0-3 / 0319