PULLING CABLE
GROUP Cable Spec INSTALLED Range Voltage Test (V) CONCLUSION
NO.
NO. Core Size (mm²) FROM TO (m) Core-Core (Average) ACCEPT REJECT
1 LLJ Lamp 1 2+G 2.5 PHASE L NEUTRAL 20 OL
(NYM 2C+G x 2,5 mm2) 2+G 2.5 PHASE L GROUND 20 OL
2+G 2.5 NEUTRAL GROUND 20 OL
PULLING CABLE
GROUP Cable Spec INSTALLED Range Voltage Test (V) CONCLUSION
NO.
NO. Core Size (mm²) FROM TO (m) Core-Core (Average) ACCEPT REJECT
1 Booth R.KSPT 2+G 4 PHASE L NEUTRAL 20 OL
(NYFGbY 3C x 4 mm2) 2+G 4 PHASE L GROUND 20 OL
2+G 4 NEUTRAL GROUND 20 OL
LAMPU LAJUR
PANEL - GENSET
Date
QC-EL.01.02 24 November 2020
PT. MITRA PERKASA EKATAMA CV. REKA RAYA TAMBA
Doc. Page 1 of 1
No
PULLING CABLE
GROUP Cable Spec INSTALLED Range Pentanahan Test (Ω) CONCLUSION
NO.
NO. Core Size (mm²) FROM TO (m) Core-Core (Average) ACCEPT REJECT
Grounding System
1 1 50 Panel DB-GT Box Control 80 1.65
(BC 1 x 50mm2)
PULLING CABLE
GROUP Cable Spec INSTALLED Range Pentanahan Test (Ω) CONCLUSION
NO.
NO. Core Size (mm²) FROM TO (m) Core-Core (Average) ACCEPT REJECT
Grounding System Epoxy Tank
1 1 50 Box Control 3 0.01
(BC 1 x 70mm2) Farm
Sistem pembumian (grounding system) adalah suatu perangkat instalasi yang berfungsi untuk melepaskan arus petir ke dalam bumi, salah
satu kegunaannya untuk melepas muatan arus petir. Tingkat kehandalan sebuah grounding ada di nilai konduktivitas logam terhadap tanah
yang ditancapinya. Semakin konduktif tanah terhadap benda logam, maka semakin baik. Kelayakan grounding harus bisa mendapatkan nilai
tahanan sebaran maksimal 5 ohm (PUIL 2000 : 68) dengan menggunakan earth ground tester. Namun begitu, untuk daerah yang resistans
jenis tanahnya sangat tinggi, resistans pembumian total seluruh sistem boleh mencapai 10 ohm (PUIL 2000 : 68).
Resistivity
Hasil Test (Ω) CONCLUSION
NO. INSTALLED
Resistivity ACCEPT REJECT
B AREA TEST
Hasil = Ω
AREA TEST
C Hasil = Ω
AREA TEST =
D `` Hasil Ω
Remark :
Date : 08/18/2021
Date
QC-EL.01.02 18 Agustus 2021
Resistivity
Hasil Test (Ω) CONCLUSION
NO. INSTALLED
Resistivity ACCEPT REJECT
F Hasil = Ω
AREA TEST
AREA TEST
G Hasil = Ω
H
AREA TEST Hasil = Ω
Remark :
Date : 08/18/2021
Date
QC-EL.01.02 18 Agustus 2021
Resistivity
Hasil Test (Ω) CONCLUSION
NO. INSTALLED
Resistivity ACCEPT REJECT
1 Tank Farm -
TANK FARM
A
Hasil = Ω
AREA TEST
TANK FARM
B Hasil = Ω
AREA TEST
TANK FARM
C Hasil = Ω
AREA TEST
Remark :
Date : 08/18/2021
Date
QC-EL.01.02 18 Agustus 2021
Resistivity
Hasil Test (Ω) CONCLUSION
NO. INSTALLED
Resistivity ACCEPT REJECT
1 Tank Farm -
TANK FARM
D Hasil = Ω
AREA TEST
TANK FARM
Hasil = Ω
AREA TEST
AREA TEST
F
TANK FARM
Hasil = Ω
Remark :
Date : 08/18/2021
Date
QC-EL.01.02 18 Agustus 2021
Resistivity
Hasil Test (Ω) CONCLUSION
NO. INSTALLED
Resistivity ACCEPT REJECT
1 Tank Farm -
TANK FARM
G Hasil = Ω
AREA TEST
AREA TEST
H
TANK FARM
Hasil = Ω
AREA TEST
I
TANK FARM
Hasil = Ω
Remark :
Date : 08/18/2021