You are on page 1of 2

Conplast SP495 CX constructive solutions

Multi-range water reducing admixture

Uses Dosage

 To reduce the water demand of a concrete mix without The optimum dosage of Conplast SP495 CX to meet specific
reducing workability, allowing increased early and ultimate requirements should always be determined by trials using
strengths without additional cement. the materials and conditions that will be experienced in use.
 To significantly improve the workability of concrete without Where increased strengths through water reduction are required
increasing water demand. the normal dosage range is from 0.25 to 1.50 litres/100 kg of
 Particularly suitable for increasing workability of ready- cementitious material, including PFA, GGBFS and microsilica.
mixed concrete at elevated temperatures. For high workability concrete the normal dosage range is from
 To reduce concrete permeability and thereby reduce water 0.25 to 1.00 litres/100 kg of cementitious material.
penetration and enhance durability. Dosages at the higher end of the ranges recommended will
give significant retardation and may only be suitable for use
Advantages in warmer climates.
 Usable across a wide dosage range to provide Use at other dosages
performance ranging from normal plasticiser to
superplasticiser, providing flexibility in performance to Dosages outside the typical ranges quoted above may be
meet a range of needs. used to meet particular mix requirements. Contact Fosroc for
advice in these cases.
 Use in production of flowing concrete permits easier con-
struction with quicker placing and compaction and reduced Effects of overdosing
labour costs.
An overdose of double the intended amount of Conplast
 Workability loss in high workability concrete is slower than
SP495 CX will result in a significant increase in retardation as
normally found with superplasticisers.
compared to that normally obtained at the intended dosage.
 Reduction in water:cement ratio enhances durability, pro- This effect is found with most water reducing admixtures, al-
ducing low permeability concrete with reduced shrinkage though the degree may vary. Provided that adequate curing is
cracking potential. maintained, the ultimate strength of the concrete will not be im-
 Suitable for use with all normal cement replacement ma- paired by increased retardation and will generally be increased.
terials, including PFA, GGBFS and microsilica. The effects of overdosing will be further increased if sulphate
resisting cement or cement replacement materials are used.
Standards compliance
An overdose will increase core workability and increased initial
Conplast SP495 CX conforms with BS 5075, BS:EN 934-2, workability will tend to extend the working life of the concrete,
BS:EN 480 and with ASTM C494 as Type A & G depending which will delay finishing and stiffening times to some extent.
on dosage used.
Properties
Description Appearance : Brown liquid
Specific gravity : Typically 1.130 at 20°C
Conplast SP495 CX is a multi-range water reducing admixture
Chloride content : Nil to BS 5075 & BS:EN934-2
based on specially selected and blended organic polymers. It is
supplied as a brown solution which instantly disperses in water.
Technical support
Conplast SP495 CX disperses the fine particles in the concrete
Fosroc provides a technical advisory service for on-site assis-
mix, enabling the water content of the concrete to perform
tance and advice on admixture selection, evaluation trials and
more effectively. The improved dispersion of cement particles
dispensing equipment.
enhances the efficiency of hydration. At higher dosage levels
retardation of setting will be obtained.
Conplast SP495 CX
Conplast SP495 CX

Instructions for use Storage

Mix design Conplast SP495 CX has a minimum shelf life of 12 months


provided the temperature is kept within the range of 2°C to
Where the primary intention is to improve strengths, initial
50°C. Should the temperature of the product fall outside this
trials should be made with normal concrete mix designs. The
range then contact your local Fosroc office for advice.
addition of the admixture will allow water reduction from the
mix whilst maintaining workability. After initial trials, minor Freezing point: Approximately -6°C
modifications to the overall mix design may be made to opti-
mise performance. Precautions

Where the primary intention is to provide high workability Health and safety
concrete, the mix design should be suitable for use as a pump
Conplast SP495 CX does not fall into the hazard classifications
mix. Advice on mix design for flowing concrete is available
of current regulations (see notes 1 and 2 below). However, it
from Fosroc.
should not be swallowed or allowed to come into contact with
Compatibility skin and eyes.

Conplast SP495 CX is compatible with other Fosroc admixtures Suitable protective gloves and goggles should be worn.
in the same concrete mix. All admixtures should be added to
Splashes on the skin should be removed with water. In case
the concrete separately and must not be mixed together prior
of contact with eyes rinse immediately with plenty of water
to addition. The resultant properties of concrete containing
and seek medical advice. If swallowed seek medical attention
more than one admixture should be assessed by the trial mixes.
immediately - do not induce vomiting.
Conplast SP495 CX is suitable for use with all types of Portland
For further information consult the Material Safety Data Sheet
cements and cement replacement materials such as PFA,
available for this product.
GGBFS, SRC and silica fume.
Fire
The use of a combination of admixtures in the same concrete
mix and or cement replacements may alter the setting time. Conplast SP495 CX is water based and non-flammable.
Trials should always be conducted to determine such setting
Cleaning and disposal
times.
Spillages of Conplast SP495 CX should be absorbed onto
Dispensing
sand, earth or vermiculite and transferred to suitable contain-
The correct quantity of Conplast SP495 CX should be meas- ers. Remnants should be hosed down with large quantities
ured by means of a recommended dispenser. The admixture of water.
should then be added to the concrete with the mixing water to
The disposal of excess or waste material should be carried out
obtain the best results. Contact Fosroc for advice regarding
in accordance with local legislation under the guidance of the
suitable equipment and its installation.
local waste regulatory authority.

Estimating - packaging Note 1: CPL Regulations 1984 Supply - Schedule 1

Conplast SP495 CX is available in 210 litre drums and bulk * Denotes the trademark of Fosroc International Limited
supply.

See separate data sheet

Important note
Fosroc products are guaranteed against defective materials and manufacture and are sold subject to its standard Conditions for the Supply of
Goods and Service. All Fosroc datasheets are updated on a regular basis. It is the user’s responsibility to obtain the latest version.

Head Office
telephone: (+9714) 2039699 fax: (+9714) 2859649 email: agf@fosroc.com
Al Gurg Fosroc Co. LLC
Regional offices
Post Box 657, Dubai Abu Dhabi, Al Gurg Fosroc telephone: 673 1779 fax: 673 1449 email: abudhabi@fosroc.com
Bahrain, YBA Kanoo telephone: 17738200 fax: 17732828 email: bahrain@fosroc.com
United Arab Emirates Kuwait, Boodai telephone: 4817618 fax: 4832124 email: kuwait@fosroc.com
www.fosroc.com Oman, Al Amana telephone: 24815080 fax: 24817554 email: oman@fosroc.com

UAE/1070/22/A

You might also like