You are on page 1of 2

Distributed Processing Units

Power Switch Over unit (PSO-P)

Description
The PSO-P module serves as a This model includes automatic fuses, The figure below shows the principle
“switch over” unit between two a version for use with the AutoChief of operation for the PSO-P:
independent 24V DC power sources, Propulsion Control System and
providing redundant power supply K-Chief alarm monitoring and control
to Distributed Process Units (DPUs). system.
The PSO have two 24VDC inputs and
five 24VDC output, including relay
output for power #1 and power #2
failures.
Technical Specifications

Supply voltage Digital output Ambient storage temp:


• 18-32 VDC • Isolated (Relay output). • -25°C to +70°C
• 1X10 and 2X10 ports
• No galvanic separation in module IP Code Max. rel. Humidity:
• IP20 • 96% non-condensing
Power consumption
• Nominal 360 W at maximum load Mounting Weight of module
(5x 3A) • In cabinet with minimum IP 20 • 1.1 kg

Nominal output Isolation Type approval


• 5 x 24 V DC, maximum 3A • Power: No isolation • DNV, LRS, BV, GL, RINA, NK,
(Automatic fuse with manual reset ABS, KR, PRS, RMR, CCS
included in module). ENV properties (allows direct mounting on
• Output voltage is equal to the • IACS E10 engines, compressors, etc. in
highest voltage supplied to the • IEC 60945 suitable cabinets)
module.
Vibration
Signal • 4G
• Relay output: Change over contact.
• Max 3A 230VAC / 32VDC Ambient operational
inductive load. temperature
• –15°C to +70°C

Copyright © 2009 Kongsberg Maritime AS – All rights reserved


Specifications may be subject to change without prior notice 340332-A

Kongsberg Maritime AS
Bekkajordet 8A Telephone: +47 815 73 700
P.O.Box 1009 Telefax: +47 850 28 028
NO-3189 Horten www.kongsberg.com
Norway km.sales@kongsberg.com

You might also like