REVERSE OSMOSIS (R.O.) PLANT – 3000LPH

1
SHREE PADMAWATI POLYMERS
F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-306401)
PH. 9829620316

TECHNO-COMMERCIAL PROPOSAL / QUOTATION FOR

REVERSE OSMOSIS PLANT

CAPACITY – 3000 LPH

DATE:- 09.12.2023

ANNEXURE – I :- DESIGNING PARAMETERS

ANNEXURE – II :- OPERATING SPECIFICATIONS

ANNEXTURE- III:- SCOPE OF SUPPLY

ANNEXTURE- IV:- TECHNICAL SPECIFICATION OF EQUIPMENTS

ANNEXTURE – V :- BROAD SCOPE OF SUPPLY

ANNEXTURE – VI :- PRICE , TERMS & CONDITIONS

2
SHREE PADMAWATI POLYMERS
F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-306401)
PH. 9829620316

ANNEXURE – I :- DESIGNING PARAMETERS

OBJECT :-

TO Design the REVERSE OSMOSIS ( R.O.) WATERTREATMENT PLANT along


with pre-treatment operation , having PRODUCTION CAPACITY OF PRODUCT /
PERMEATE WATER OF 3000 LITRE / HOUR . (3.0 m3/Hr.). For Boil Feed Water
Application

DESIGN ASSUPTION:-

(1) No. Of working Shift Per Day. = 2 Shift. / Day.

(2) No. Of working Hours Per Shift. = 10 Hours./ Shift.

(3) No. Of working Hours Per Day = 20 Hours/ Day


( 10 Hours Day. + 10 Hours Night )

3
SHREE PADMAWATI POLYMERS
F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-306401)
PH. 9829620316

Continue.. ANNEXTURE –I

PRODUCTION CAPACITY OF R.O. PLANT:-


(1) R.O. TREATED FLOW RATE:- = 3000 LPH
(PRODUCT / PERMEATE WATER)

(2) R.O. TREATED WATER OUT PER SHIFT = 30,000 LITRE / SHIFT.
(PRODUCT / PERMEATE WATER)

(3) WASTE WATER FLOW RATE:- = 3000 LPH


( REJECT / CONCENTRATE WATER)

(4) WASTE WATER OUT PUT PER SHIFT:- = 30,000 LITRE / SHIFT.
( REJECT / CONCENTRATE WATER)

(5) % RECOVER OF R.O. SYSTEM = 50%

CONSUPTION REQUIRE FOR R.O. PLANT:-

(1) RAW WATER REQUIRE PER HOUR. = 6,000 LPH


(FEED WATER FLOW RATE )

(2) RAW WATER REQIRED FOR A DAY = 1,20,000 LITRE

(3) ELECTRICITY DEMAND LOAD REQ. = 8 HP/ 6.0 KW.

4
(4) ELECTRICITY TYPE. = 415Volt./3Ph./50Hz

SHREE PADMAWATI POLYMERS


F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-306401)
PH.9829620316

Continue.. ANNEXTURE –I

BASIS OF DESIGN:-
The following raw water / feed water sourced from well , analysis assumed as
basis of design for R.O. Plant.

(I) RAW WATER CHARACTERISTICS

Sr. PARAMETERS VALUE

01 PH 6–8
02 TOTAL DISSOLVED SOLIDS / TDS 4000 PPM
03 TOTAL SUSPENDED SOLIDS / TSS 2 – 5 PPM
04 TURBIDITY < 1.0 NTU
05 SLIT DENSITY INDEX / SDI (15 min.) < 3-5
06 FREE CHLORINE (Cl2) <0.1 – 0.0 PPM
07 FREE ORGANICS NIL
08 IRON / MAGANANE (Fe+3 / Mn+2) NIL
09 TOTAL HARDNESS as CaCO3 100 PPM
10 TOTAL ALKALINITY as CaCO3 75 PPM
11 P. ALKALINITY as CaCO3 NIL
12 OIL & GREASE NIL
13 CHLORIDE (Cl-) as CaCO3 250 PPM
14 FLUORIDE (F-) as CaCO3 <10 PPM
15 SULPHATE (SO4-) as CaCO3 <150 PPM
16 TOTAL SILICA (SiO2) as CaCO3 <20 PPM
17 SODIUM (Na+) as Na <150 PPM 5
18 CONDUCTIVITY uS / cm
SHREE PADMAWATI POLYMERS
F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-06401)
PH.9829620316

Continue.. ANNEXTURE –I

(II) R.O. TREATED / PRODUCT / PERMEATE WATER QUALITY

The following are the permeate water quality

Sr. PARAMETERS VALUE

01 PH 6.5- 7
02 TOTAL DISSOLVED SOLIDS / TDS <50 PPM
03 TOTAL SUSPENDED SOLIDS / TSS < 3 PPM
04 TURBIDITY NIL
05 SLIT DENSITY INDEX / SDI (15 min.)
06 FREE CHLORINE (Cl2) NIL
07 FREE ORGANICS NIL
08 IRON / MAGANANE (Fe+3 / Mn+2) NIL
09 TOTAL HARDNESS as CaCO3 0.0 PPM
10 TOTAL ALKALINITY as CaCO3 1 PPM
11 P. ALKALINITY as CaCO3 NIL
12 OIL & GREASE NIL
13 CHLORIDE (Cl-) as CaCO3 <10 PPM
14 FLUORIDE (F-) as CaCO3 <1 PPM
15 SULPHATE (SO4-) as CaCO3 <10 PPM
16 TOTAL SILICA (SiO2) as CaCO3 <0.0 PPM

6
17 SODIUM (Na+) as Na <15 PPM
18 CONDUCTIVITY uS / cm

SHREE PADMAWATI POLYMERS


F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-306401)
PH. 9829620316

ANNEXTURE –(II ) OPERATING SPECIFICATIONS

(I) OPERATING SPECIFICATIONS

DESIGN TEMPRATURE 25 – 40 C
FEED WATER FLOW RATE (M3/hr) 6.000
PERMEATE WATER FLOW RATE (M3/hr) 3.000
REJECT / CONCENTRATE WATER FLOW RATE 3.000
(M3/hr)
TYPE /ARRAY OF RO PLANT Single Stage
SYSTEM RECOVERY OF 1st Stage 50%
OVER-ALL RECOVERY 50%
WORKING PRESSURE FOR 1st Stage 10-15 Bar

(II) R.O. FEED WATER LIMITING CONDITION

TURBIDITY <1.0 NTU


SLIT DENSITY INDEX /SDI (15 min.) <3
HEAVY METALS NIL
OIL & GREASE NIL
ORGANICS & BACTERIA NIL

7
RESIDUAL CHLORINE / OXIDISING NIL
AGENT
TEMPERATURE 35 C
COLOUR COLOUR LESS
ODOUR ODOUR LESS

SHREE PADMAWATI POLYMERS


F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-06401)
PH. 9829620316

ANNEXTURE- III

(I) SCOPE OF SUPPLY

 RAW WATER PUMP

 MULTI GRADED FILTER (MGF)

 ACTIVATED CARBON FILTER (ACF)

 DOSING PUMP

 MICRON FILTER

 HIGH PRESSURE PUMP

 R.O. ASSEMBLY

 SYSTEM ACCESSORIES

8
 INSTRUMENTS

 CONTROL PANEL

 SKID

SHREE PADMAWATI POLYMERS


F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-306401)
PH. 9829620316

ANNEXTURE- IV
TECHNICAL SPECIFICATION OF EQUIPMENTS

(01) RAW WATER PUMP:

(1.1) PURPOSE:- To feed the Dual Media Filter @ pressure more


than 2.0 bar ,which is minimum operating pressure
for pressure filter , but less than 4.5 bar.

(1.2) PUMP SPECIFICATION:-

Quantity offered : One No


Type : Monoblock Centrifugal Pump
MOC : Cast Iron (C.I.)
Operating Flow rate : 6.0 M3 / Hr. @ 25 m Head
Operating : 2.5 – 3.5 Kg. / cm2
Type of Drive : III phase, squirrel cage induction

9
Motor
Electrical Connection Required. : 415 Volt. / 3 phase / 50 Hz.
Electrical Power (KW / RPM) : 1.5 KW/(2.0 HP)/ 2900 (Approx.)
Make : KIRLOSKAR/CRI/TEXMO/EQU.

(02) MULTI GRADED MEDIA FILTER (MGF)


(PRESSURE SAND FILTER / DUAL MEDIA FILTER)

(2.1) Purpose:- To Remove the Total Suspended Solid (TSS) particles


& dirt of particle size greater than 50 Micron, and thereby
Reducing the SDI(Silt Density Index) Load of feed Water,
Which can foul the R.O. Membrane.

(2.2) Specification :-

PRESSURE-VESSEL:
Quantity offered : One No
Type : Down Flow – 24 X 72 / 4 ” TOP / 4” Bottom
OPENING WITH FAPT & TRIPOD STAND.

MOC : FRP – Epoxy Resin impregranated glass fibre


Roving wound in helical format on frp liner.

Size : 24” X 72”


Diameter of Tank : 24”
Height of Tank. : 72”
Wall thickness of Tank. : 10.0 mm.
Testing Pressure : 10 bar ( 10 kgf. / cm2 ) = 150 psig.
Operating Flow rate : 6.0 M3 / Hr. @ 30 m Head
Operating Pressure : 2.5 – 3.5 Kg. / cm2.
Make & Brand : Stracture from Pentair / Advance / Aventure
HT. CAMMA.

VALVE:

10
Make : Inetiative / UKL / PREHAR / PENTAIR
Valve Type : MULTI PORT – SINGLE LEVER VALVE
MOC : NORYL .
SIZE OF MPV : 40 NB / 40 MM.
MAX. FLOW RATE : 15000 LITRE / HOUR.
WORKING FLOW RATE: 6000 LITRE /HOUR ( 6.0 M3 / HR.)
MAX. WORKING : 6 BAR. ( 6.0 kgf. / cm2 ) = 90 psig.
PRESSURE
WORKING PRESSURE : 2.5 – 3.5 BAR ( 2.5 – 3.5 kgf./ cm2 ) = 37.5 – 52.5 psig.
WORKING FLOW : DOWN FLOW.

MEDIA:

Mixed Bed of Sand Media consisting of following.


(i) Gravels (ii) Pebbles (iii) Quartz Sand & (iv) Anthracite
Bed Depth is 800mm – 1000mm.
Average Porosity of bed is 50 micron particulate size

(03) ACTIVATED CARBON FILTER (ACF)

(3.1) Purpose:- To Remove the Total Organic Matter/Compound (TOC)


In Raw Water , thereby water gets free from Colour,
Smell & Odor, that was due to Organic Impurities.
Activated Carbon can adsorb the free Chlorine
containing in feed Water/ Raw Water, that is essential
to save the R.O Membrabe

(3.2) Specification :-

PRESSURE-VESSEL:
Quantity offered : One No
Type : Down Flow – 24” X 72” / 4” TOP / 4” Bottom
OPENING WITH FAPT & TRIPOD STAND.

MOC : FRP – Epoxy Resin impregranated glass fibre


Roving wound in helical format on frp liner.

11
Size : 24” X 72”
Diameter of Tank : 24”
Height of Tank. : 72”
Wall thickness of Tank. : 10.0 mm.
Testing Pressure : 10 bar ( 10 kgf. / cm2 ) = 150 psig.
Operating Flow rate : 6.0 M3 / Hr. @ 30 m Head
Operating Pressure : 2.5 – 3.5 Kg. / cm2.
Make & Brand : Stracture from Pentair / Advance / Aventure
HT. CAMMA.

VALVE:

Make : Inetiative / UKL / PREHAR / PENTAIR


Valve Type : MULTI PORT – SINGLE LEVER VALVE
MOC : NORYL .
SIZE OF MPV : 40NB / 40 MM.
MAX. FLOW RATE : 15000 LITRE / HOUR.
WORKING FLOW RATE: 6000 LITRE /HOUR ( 6.0 M3 / HR.)
MAX. WORKING : 10 BAR. ( 6.0 kgf. / cm2 ) = 90 psig.
PRESSURE
WORKING PRESSURE : 2.5 – 3.5 BAR ( 2.5 – 3.5 kgf./ cm2 ) = 37.5 – 52.5 psig.
WORKING FLOW : DOWN FLOW.

MEDIA:

Activated Carbon / Charcoal derived from Coconut-Shell ( I.V. 900 – 1100 )


Bed supported on bottom filled with Gravels & Pabbles.
Bed Depth is 800 – 1000 mm.
Average Porosity of bed is 50 micron particulate size

(04) ANTISCALANT DOSING SYSTEM:

(4.1) Purpose:- To Dose the Anti-Scalant Chemical to protect the


R.O. Membrane from the Scaling formation on
Membrane surface.

12
(4.2) Specification of Dosing Pump:-

Quantity offered : One No


Type : Electronic Diaphram Dosing Pump
Operating Flow rate : 6 L.P.H. (Max.)
Operating Pressure : 7 bar
Make : E-dose-Aster / Etatrone DS. Italy
Milton-USA / SEKO-Japan
Dosing Tank : 50 litre HDPE Tank

(05) MICRON CARTRIDGE FILTER:-

(5.1) Purpose:- To Remove the Fine particles up to 05 micron


& thereby reducing the SDI (Silt Density Index)
Load containing in feed water to desire level <3
So TSS Load on Membrane gets reduced.

(5.2) Specification of Cartridge Filter & Housing.

HOUSING:

Make & Brand : Jumbo Big Blue – PENTAIR


MOC of Housing : PP
Length : 20” (inch)
Diameter : 4.5” (inch)
Quantity offered : One No

CARTRIDGE-FILTER:

Type : Non-Woven PP Platted wound Cartridge.


Make : Filtermation – Malaseya
Purtex – G.E. Water USA.

13
MOC : Polypropylene
Length : 20”
Diameter : 4”
Quantity : 1 Nos.
Micron Rating. : 5 Micron.

(06) HIGH PRESSURE PUMP:-

(6.1) Purpose:- To Feed the Reverse Osmosis (R.O.) Membrane


At pressure more than the Osmotic Pressure of
Feed water taking into consideration of Flux Rate,
Flow & Recovery.

(6.2) Specification of High Pressure Pump:-

Quantity offered : One No


Type : Vertical Multi-Stages Centrifugal Pump
Operating Flowrate. : 6.0 M3 / Hr (6000 LPH )@ 100 -120MWC
Discharge Pressur. : 10-12 Kg. / cm2
MOC of Pump : SS - 304
Make : CRI-/ SUMO-/ CNP-/ GROUNDFOS
Electrical Power KW/(HP) : 5 KW / (7.5 HP.)
Req. Electrical Supply : 415 Volt. / 3 Phase / 50 HZ

(07) R.O. ASSEMBLY:-

(7.1) REVERSE OSMOSIS (R.O.) MEMBRANE:

Purpose:- To Remove the Major part of TDS ( Total Dissolved- Solid )


up to 98- 99% by Reverse Osmosis Membrane
and designed to give adequate Flow & Recovery

Specification of R.O. Membrane


(a)Type of Membrane : Thin Film Composite Polyamide

14
Spirally Wounded.(TFC-PA-SW)
8040-TFC – PA – Spiral.

(b) Diameter of RO Memrane : 8” (inch)


(c) Length of RO Membrane : 40” (inch) / 1.0 meter.
(d) No. of RO Membrane : 4 Nos.
(e) % Recovery per Membrane : 15 %
(f) Salt Rejection per Membrane : 98 – 99 %
(g) Make of Membrane : Hydranautics – USA (CPA2 – 8040)
DOW- FILMTEC- USA (BW30-365)
TORAY – JAPAN ( TFC 8040-400 )
( TM720D400)

(7.2) R.O. PRESSURE TUBE :-

Purpose:- To Pack the Reverse Osmosis Membranes in High


Pressure Rating Housing and Operate at High
Pressure up to 20 bar ( 20 Kgf / Cm2)= 300 Psig.

Specification of Pressure Tube / Housing.

MOC of Pressure Housing/Tube : FRP/Fibre Reinforced Plastics

No of Pressure Housing/Tube : 1 Nos ( 4 Element Long)

Make of Pressure Housing/Tube : EcoLine- Pentair ,


Aventure - Wave Cybre,

Diameter of Pressure Housig/Tube. : 8.2”(inch)

Length of Pressure Housing / Tube. : 6.4 Meter.

Max. Operating Pressure : 20bar / 20 Kgf./ Cm2 / 300 Pisg.

Operating Flow rate : 12.0 M3 / Hr

Operating Pressure : 10– 12 Kg. / cm2

15
(8) ELECTRICAL PANEL:-

Puspose:- To provide the Safe & Smooth power supply to Pumps.


A PLC/ Microprocessor based Complete Automatic /
Manual Mode
Electronic Panel provided as a safety measure for the
The Pumps & other electrical items.

Specification of Electrical Panel:-

(a) Incomer Supply Switch : 415 V / RYBN- 3phase / 30 Amp.


Siemens, L&T, ABB etc.

(b) Contractor : Siemens, L&T,ABB or Equt.

(c) Overload Thermal Relay : Siemens, L&T, ABB,Schnider

(d) Voltmeter, Amparemeter,: inbuilt electronic

(e) Timer Switch. : inbuilt

(f) Rocker Switch : KAYCEE, Jaibalaji

(g) Single Phase Preventer : inbuilt

(h) PLC/Microprocessor : Aster make

(9) INSTRUMENTATION:-

16
(9.1) PRESURE GAUGE :-

Purpose :- To Monitor the Pressure Reading of any Unit of RO System,


& For Calculating Δ P ( Pressure Drop ) of each Unit of
RO System.

Specification of Pressure Gauge:-

Type : Liquid Filled Burdon tube

Quantity : 6 Nos.

MOC : Wetted Parts – SS

Dial Size : 2.5” / 62 mm

Mounting : Bottom entry – Field side


Back entry – Panel side

Connection : 1 / 4 “ BSPT/ ½” BSPT

Range : 0 – 150 psi – Low pressure


: 0 – 600 psi – High pressure

Make ; H.Guru/ Wick /Waree/ Gluck / Feibig

(9.2) Flow Meter / Roto-Meter:-

Purpose :- To Measure the online Flow of Permeate Water & Reject Water.,
And Control the designed set % Recovery by Flow Meter Reading

17
Of RO System.

Specification of ROTA-METER

Quantity : 2 Nos ( One in Permeate side


& One in Reject side)

Type : Panel Mounted / Field Mounted

MOC : Heavy Duty Acrylic Body Tube &


Float – SS-304

Range : 0 – 10.0 M3/ Hr. FLOW RATE

Make : Flow-Star / Aster / Transa-Equip/


Spink Control

( 9.3 ) TDS Meter / Conductivity Meter:-

Purpose:- To Measure the TDS (Total Dissolved Solid ) in Permeate


Water.

Specification of TDS Meter

Quantity : 1 Nos

Range : 0 – 9999 PPM

Reading Option : PPM (Mg / Litre) & Micro-Siemens/cm

Sensor : On line Conductivity electrode

Make : Aster / HM – USA

(9.4) Pressure Switch :-

18
Purpose :-

Low Pressure Switch (LPS ) :- To Protect the High Pressure


Pump (HPP) from Dry Running.

High Pressure Switch (HPS):- To Protect the High Pressure


Pump (HPP) from Back Pressure and also Protect the Pressure
Tube from pressure surge.

Specification of Pressure Switch:-

Quantity : 1 Nos ( Low Pressure & High Pressure )

Range : 0 – 450 psi

Connection Port : 1/4" BSPT SS316

Make : Indfos / Denfos/Orion

(10) PIPING & FITTING:-

Low Pressure Piping & Fitting :- Rigid PVC or Standard uPVC


ASTRAL / Ashirwad / Supreme Make.

High Pressure Piping & Valves :- SS304 PIPE & CF 8M Valve

19
SHREE PADMAWATI POLYMERS
F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-06401)
PH 9829620316

ANNEXTURE- V

BROAD SCOPE OF SUPPLY

Our scope shall cover design, engineering , supply and supervision of erection and
Commissioning for the R.O. plant described in the following annexure. The broad
Scope of supply is as follows:-

S.No. EQUIPMENT / MATERIAL QTY. OFFERED

20
01 RAW WATER STRORAGE TANK BY CLIENT.
02 RAW WATER PUMP ONE
03 DUAL MEDIA FILTER ONE
04 ACTIVATED CARBON FILTER ONE
05 ANTISCALANT DOSING SYSTEM ONE
06 ACID DOSING SYSTEM -----
07 CARTRIDGE FILTER WITH HOUSING ONE
08 HIGH PRESSURE PUMP WITH MOTOR ONE
09 R.O. BLOCK ONE
10 INTERCONNECTING PIPE WORK ONE LOT
11 SENSOR CABLES FROM FIELD TO RO ONE
INSTRUMENT PANEL
12 PERMEATE STORAGE TANK & PUMP BY CLIENT
13 INSTRUMENT TDS/CONDUCTIVITY METERONE
14 ROTO-METER TWO
15 PRESSURE INDICATOR SIX
16 PRESSURE SWITCH ONE
17 ELECTRIC CONTROL PANEL ONE
18 U-PVC & SS PIPING,FITTINGS & VALVES ONE LOT
19 MS SKID ONE

SHREE PADMAWATI POLYMERS


F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-06401)
PH. 91-2932-23031/ MOB.0946081817

ANNEXTURE – VI :- PRICE , TERMS & CONDITIONS

(1) PRICE OF RO PLANT OF 3000 LPH RO WATER CAPACITY

Our price for the supply of R.O. system 3.000 M3/ Hr.(3000 litre per hour) as specified in
our Technical offer / proposal is Rs. 4,50,400/- (Rupees Four lacs Fifty thousand FOUR
hundred only)
The Supervision of erection & commissioning charges are included

21
R.O. system plant Cost := Rs 4,50,400/--
(3.0 M3/hr.product water)
Including installation and commission .

Sub Total := Rs 4,50,400/-

GST @ as Applicable 18% := Rs 81,072/-

Total := Rs 5,31,472/-

In Word: Rupees Five lac Thirty One Thousand Four hundred Seventy Two Only.

SHREE PADMAWATI POLYMERS


F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-06401)
PH. 9829620316

(2) TERM & CONDITIONS

Terms of Payments:-

22
60% of the total value of the order to be paid as advance along with purchase order.

The balance 40% against Performa invoice prior to dispatch.

Validity:-

Our offer is valid for your consideration for a period of 30 days from the date of our
Proposal./ Offer for RO Plant

Delivery:-

We shall design , manufacture, and supply the equipment within five to Six Weeks
from the Date of receipt of technically and commercially clear order along with advance.

Warrantee & Garentee:-

Our RO Plant will carry the Warrantee for One Year from the Date of Invoice against
Any manufacturing defects & Design. Any Faults or / and Breakage occur due to
Mis-operation / faulty running of RO Plant / any kind of working default will not cover
Under the warrantee period. All pumps warrantee cover as per pump manufacturer and
RO membrane will not cover any warrantee as per their manufacturer accept any manufacturing
Defects, that can be replace by membrane manufacturer.

SHREE PADMAWATI POLYMERS


F-271, MANDIA ROAD, PALI – MARWAR (RAJASTHAN) – 306401,
Ph:- 9829620316

To,
DATE:-27.12.23
M/s Vikram Industries
Mandia Road, Riico Industrial Area,

Kind Attend. To :- SRI MOHIT JI

Sub:- Techo-commercial offer for your requirement of Reverse Osmosis

23
Water Treatment Plant. With Capacity of 3000 liter / hr.

Thank you very much for the courtesy extended to us during our discussion with you . As
per discussion with you & getting inquiry about the feed water characteristics, We
are pleased to give our techno - commercial offer your requirement of Reverse
Osmosis Water Treatment Plant of 3000 L.P.H Product / Permeate Water Capacity.
That plant will need about 6,000 liter/hr. as feed raw water.

We look forward to serving your esteemed organization.

Warm regards.

Rajesh Kothari.
Shree Padmawati Polymers