OBJECT :-
DESIGN ASSUPTION:-
3
SHREE PADMAWATI POLYMERS
F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-306401)
PH. 9829620316
Continue.. ANNEXTURE –I
(2) R.O. TREATED WATER OUT PER SHIFT = 30,000 LITRE / SHIFT.
(PRODUCT / PERMEATE WATER)
(4) WASTE WATER OUT PUT PER SHIFT:- = 30,000 LITRE / SHIFT.
( REJECT / CONCENTRATE WATER)
4
(4) ELECTRICITY TYPE. = 415Volt./3Ph./50Hz
Continue.. ANNEXTURE –I
BASIS OF DESIGN:-
The following raw water / feed water sourced from well , analysis assumed as
basis of design for R.O. Plant.
01 PH 6–8
02 TOTAL DISSOLVED SOLIDS / TDS 4000 PPM
03 TOTAL SUSPENDED SOLIDS / TSS 2 – 5 PPM
04 TURBIDITY < 1.0 NTU
05 SLIT DENSITY INDEX / SDI (15 min.) < 3-5
06 FREE CHLORINE (Cl2) <0.1 – 0.0 PPM
07 FREE ORGANICS NIL
08 IRON / MAGANANE (Fe+3 / Mn+2) NIL
09 TOTAL HARDNESS as CaCO3 100 PPM
10 TOTAL ALKALINITY as CaCO3 75 PPM
11 P. ALKALINITY as CaCO3 NIL
12 OIL & GREASE NIL
13 CHLORIDE (Cl-) as CaCO3 250 PPM
14 FLUORIDE (F-) as CaCO3 <10 PPM
15 SULPHATE (SO4-) as CaCO3 <150 PPM
16 TOTAL SILICA (SiO2) as CaCO3 <20 PPM
17 SODIUM (Na+) as Na <150 PPM 5
18 CONDUCTIVITY uS / cm
SHREE PADMAWATI POLYMERS
F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-06401)
PH.9829620316
Continue.. ANNEXTURE –I
01 PH 6.5- 7
02 TOTAL DISSOLVED SOLIDS / TDS <50 PPM
03 TOTAL SUSPENDED SOLIDS / TSS < 3 PPM
04 TURBIDITY NIL
05 SLIT DENSITY INDEX / SDI (15 min.)
06 FREE CHLORINE (Cl2) NIL
07 FREE ORGANICS NIL
08 IRON / MAGANANE (Fe+3 / Mn+2) NIL
09 TOTAL HARDNESS as CaCO3 0.0 PPM
10 TOTAL ALKALINITY as CaCO3 1 PPM
11 P. ALKALINITY as CaCO3 NIL
12 OIL & GREASE NIL
13 CHLORIDE (Cl-) as CaCO3 <10 PPM
14 FLUORIDE (F-) as CaCO3 <1 PPM
15 SULPHATE (SO4-) as CaCO3 <10 PPM
16 TOTAL SILICA (SiO2) as CaCO3 <0.0 PPM
6
17 SODIUM (Na+) as Na <15 PPM
18 CONDUCTIVITY uS / cm
DESIGN TEMPRATURE 25 – 40 C
FEED WATER FLOW RATE (M3/hr) 6.000
PERMEATE WATER FLOW RATE (M3/hr) 3.000
REJECT / CONCENTRATE WATER FLOW RATE 3.000
(M3/hr)
TYPE /ARRAY OF RO PLANT Single Stage
SYSTEM RECOVERY OF 1st Stage 50%
OVER-ALL RECOVERY 50%
WORKING PRESSURE FOR 1st Stage 10-15 Bar
7
RESIDUAL CHLORINE / OXIDISING NIL
AGENT
TEMPERATURE 35 C
COLOUR COLOUR LESS
ODOUR ODOUR LESS
ANNEXTURE- III
DOSING PUMP
MICRON FILTER
R.O. ASSEMBLY
SYSTEM ACCESSORIES
8
INSTRUMENTS
CONTROL PANEL
SKID
ANNEXTURE- IV
TECHNICAL SPECIFICATION OF EQUIPMENTS
9
Motor
Electrical Connection Required. : 415 Volt. / 3 phase / 50 Hz.
Electrical Power (KW / RPM) : 1.5 KW/(2.0 HP)/ 2900 (Approx.)
Make : KIRLOSKAR/CRI/TEXMO/EQU.
(2.2) Specification :-
PRESSURE-VESSEL:
Quantity offered : One No
Type : Down Flow – 24 X 72 / 4 ” TOP / 4” Bottom
OPENING WITH FAPT & TRIPOD STAND.
VALVE:
10
Make : Inetiative / UKL / PREHAR / PENTAIR
Valve Type : MULTI PORT – SINGLE LEVER VALVE
MOC : NORYL .
SIZE OF MPV : 40 NB / 40 MM.
MAX. FLOW RATE : 15000 LITRE / HOUR.
WORKING FLOW RATE: 6000 LITRE /HOUR ( 6.0 M3 / HR.)
MAX. WORKING : 6 BAR. ( 6.0 kgf. / cm2 ) = 90 psig.
PRESSURE
WORKING PRESSURE : 2.5 – 3.5 BAR ( 2.5 – 3.5 kgf./ cm2 ) = 37.5 – 52.5 psig.
WORKING FLOW : DOWN FLOW.
MEDIA:
(3.2) Specification :-
PRESSURE-VESSEL:
Quantity offered : One No
Type : Down Flow – 24” X 72” / 4” TOP / 4” Bottom
OPENING WITH FAPT & TRIPOD STAND.
11
Size : 24” X 72”
Diameter of Tank : 24”
Height of Tank. : 72”
Wall thickness of Tank. : 10.0 mm.
Testing Pressure : 10 bar ( 10 kgf. / cm2 ) = 150 psig.
Operating Flow rate : 6.0 M3 / Hr. @ 30 m Head
Operating Pressure : 2.5 – 3.5 Kg. / cm2.
Make & Brand : Stracture from Pentair / Advance / Aventure
HT. CAMMA.
VALVE:
MEDIA:
12
(4.2) Specification of Dosing Pump:-
HOUSING:
CARTRIDGE-FILTER:
13
MOC : Polypropylene
Length : 20”
Diameter : 4”
Quantity : 1 Nos.
Micron Rating. : 5 Micron.
14
Spirally Wounded.(TFC-PA-SW)
8040-TFC – PA – Spiral.
15
(8) ELECTRICAL PANEL:-
(9) INSTRUMENTATION:-
16
(9.1) PRESURE GAUGE :-
Quantity : 6 Nos.
Purpose :- To Measure the online Flow of Permeate Water & Reject Water.,
And Control the designed set % Recovery by Flow Meter Reading
17
Of RO System.
Specification of ROTA-METER
Quantity : 1 Nos
18
Purpose :-
19
SHREE PADMAWATI POLYMERS
F-271,MANDIA ROAD, RIICO INDUSTRIAL AREA,
PALI- MARWAR (RAJASTHAN-06401)
PH 9829620316
ANNEXTURE- V
Our scope shall cover design, engineering , supply and supervision of erection and
Commissioning for the R.O. plant described in the following annexure. The broad
Scope of supply is as follows:-
20
01 RAW WATER STRORAGE TANK BY CLIENT.
02 RAW WATER PUMP ONE
03 DUAL MEDIA FILTER ONE
04 ACTIVATED CARBON FILTER ONE
05 ANTISCALANT DOSING SYSTEM ONE
06 ACID DOSING SYSTEM -----
07 CARTRIDGE FILTER WITH HOUSING ONE
08 HIGH PRESSURE PUMP WITH MOTOR ONE
09 R.O. BLOCK ONE
10 INTERCONNECTING PIPE WORK ONE LOT
11 SENSOR CABLES FROM FIELD TO RO ONE
INSTRUMENT PANEL
12 PERMEATE STORAGE TANK & PUMP BY CLIENT
13 INSTRUMENT TDS/CONDUCTIVITY METERONE
14 ROTO-METER TWO
15 PRESSURE INDICATOR SIX
16 PRESSURE SWITCH ONE
17 ELECTRIC CONTROL PANEL ONE
18 U-PVC & SS PIPING,FITTINGS & VALVES ONE LOT
19 MS SKID ONE
Our price for the supply of R.O. system 3.000 M3/ Hr.(3000 litre per hour) as specified in
our Technical offer / proposal is Rs. 4,50,400/- (Rupees Four lacs Fifty thousand FOUR
hundred only)
The Supervision of erection & commissioning charges are included
21
R.O. system plant Cost := Rs 4,50,400/--
(3.0 M3/hr.product water)
Including installation and commission .
Total := Rs 5,31,472/-
In Word: Rupees Five lac Thirty One Thousand Four hundred Seventy Two Only.
Terms of Payments:-
22
60% of the total value of the order to be paid as advance along with purchase order.
Validity:-
Our offer is valid for your consideration for a period of 30 days from the date of our
Proposal./ Offer for RO Plant
Delivery:-
We shall design , manufacture, and supply the equipment within five to Six Weeks
from the Date of receipt of technically and commercially clear order along with advance.
Our RO Plant will carry the Warrantee for One Year from the Date of Invoice against
Any manufacturing defects & Design. Any Faults or / and Breakage occur due to
Mis-operation / faulty running of RO Plant / any kind of working default will not cover
Under the warrantee period. All pumps warrantee cover as per pump manufacturer and
RO membrane will not cover any warrantee as per their manufacturer accept any manufacturing
Defects, that can be replace by membrane manufacturer.
To,
DATE:-27.12.23
M/s Vikram Industries
Mandia Road, Riico Industrial Area,
23
Water Treatment Plant. With Capacity of 3000 liter / hr.
Thank you very much for the courtesy extended to us during our discussion with you . As
per discussion with you & getting inquiry about the feed water characteristics, We
are pleased to give our techno - commercial offer your requirement of Reverse
Osmosis Water Treatment Plant of 3000 L.P.H Product / Permeate Water Capacity.
That plant will need about 6,000 liter/hr. as feed raw water.
Warm regards.
Rajesh Kothari.