Professional Documents
Culture Documents
Operator’s Manual
Hyundai Intelligent Watch Monitoring System
Abbreviation
Terms
Interface
Interface attribute describes the methods and rules governing interaction between different
entities.
Local Area Network
A LAN is a group of computers and associated equipment that are linked by cable and that share
a communications line for running the communication and protocols. It is used with a commercial
network.
This manual describes the function, the operation of the HiWMS(Hyundai Intelligent Watch
Monitoring System). The description is based on the requirements of ship yard.
The aim of this instruction and guidance is to provide successful operation for the HiWMS.
DOCUMENT STATUS
Issue
Issue No. Inc. by Issue No. Issue Date/Year Inc. by
Date/Year
R 1.0 30.08.2004 MDTECH R2.1 03.04.2009 M.W.LEE
R1.1 28.09.2005 M.W.LEE R2.2 05.03.2010 M.W.LEE
R1.2 07.11.2005 M.W.LEE
R1.3 25.07.2007 M.W.LEE
R1.4 30.06.2008 M.W.LEE
R2.0 01.10.2008 M.W.LEE
CHANGES IN DOCUMENT
Paragraph
No. Issue No. Description of Change
No.
1 R1.0 INITIAL
2 R1.1 4.5.4 Update
3 R1.2 4.5.2 Update
4 R1.3 2.2.1 Update
5 R1.4 3.2 Update
6 R2.0 Modify
7 R2.1 3.2,3.3,4.2 Update
8 R2.2 Modify
CONTENTS
Section Page
1 SYSTEM OVERVIEW
1.1 Introduction
1.2 Functions
Bridge Safety
- Indicates that an alert officer of the navigational watch is present on the bridge.
- Alarms operation status on the bridge in the event of a failure of the bridge navigation
equipment and the severe failure of shipboard safety systems.
- Provides visual and audible alarms and warnings.
Officer of the Watch Alertness-check
System used for periodic verification of the officer of the navigational watch's alertness
shall be adjustable time intervals and constructed, fitted and arranged so that only the
ship's master has access to the component for setting the appropriate intervals.
Alarm Transfer
Alarm that is transferred from the bridge to the master and the back-up navigator in case
of any officer of the watch deficiency (absence, lack of alertness, no response to another
alarm/warning, etc.). Alarm Sequence without acknowledgements is followings.
- Visual Flashing Indication.
- First Stage Audible (Sound) Alarm.
- Second and Third Stage Remote Audible (Sound) Alarm.
Back-up Navigator Call-Alarm
- Provisions are to be made at the bridge to activate the master and back-up navigator
call-alarm.
1.3 Operation
The following functions are available from the HiWMS Bridge Unit (WBU) :
Operation Mode
- Automatic (Automatically brought into operation whenever the ship’s heading or track
control system is activated and inhibited when this system is not activated)
- Manual (Interval Check System On / Off manually by operator)
Security (Password) Operation
- Adjust Timer and Periods
- Privilege level of users
Operation of indication and Alarm
- Audible and Visual alarm indications
- Reset for Sound-Off and Acknowledge of alarms
Emergency Call Facility
- Selection of back-up navigator on duty
- Call of back-up navigator
1.4 Specification
Panel mounting
Flush mounting - attached Table.
Power requirements
- Ship main and emergency power supplies.
- Internal battery float charged from the 24V.
Interface
In - reset devices or navigation equipment. Out - visual indications and audible
devices.
Environmental requirements
Operating temperature: -15 °C to + 70 °C, Maximum humidity: 96% no condensation.
EMC properties
IEC 60945
Software Version
WBU Software : Version1.0.2.x
2 SYSTEM CONFIGURATION
Hyundai Intelligent Watch Monitoring System (HiWMS) unit consists of two separated units.
The HiWMS Bridge Unit (WBU) is a stand-alone panel or flush mounted assembly based on
standard hardware and software. It performs interval-checking algorithm requiring manual
acknowledgment within pre-set intervals, thereby detecting the well being of the navigating
officer.
A navigation alarm system which transfers operational warnings from the grounding and
collision avoidance system as well as instrument malfunction alarms to a WBU and further to
the captains quarters, public areas and the cabin of a back-up navigator.
The alarm output can be connected to navigator cabins, public areas and other alarm
systems, via a digital output relays in HiWMS I/O Unit (WIU).
External
3 -NMEA 0183, IEC 61162-1 Std. Protocol
Communication
Primary Secondary BRIDGE WING (P) WING (S) BRIDGE WING (P) WING (S) EXT. EXT. AUTO
Power Power CONTROL CONSOLE CONSOLE BUZZER BUZZER BUZZER RESET SND. OFF. PILOT
(DC24V) (DC24V)
CONSOLE
P.FAIL RST WARN RST WARN RST WARN RST BUZZER BUZZER BUZZER
POWER
(DC24V)
POWER
Terminal Block
BRIDGE
CAPTAIN'S QUARTER CHIEF OFFICER 2'ND OFFICER 3'RD OFFICER PUBLIC ROOM
3 SYSTEM FUNCTION
The system is to be arranged so that only the captain(Master) has access to the means for
setting the intervals and modes.
The system is to be designed and arranged such that only the vessel’s Master(captain) has
access for enabling and disabling it and setting the appropriate intervals so that it cannot be
operated by an unauthorized manner, i.e., removing the fuses or keeping the
acknowledgment button permanently depressed.
a) Off-course
b) Off-track
c) Planned route deviation
d) Pre-warning of approach-way point , and
the closest point of approach
Required alarms and reset
e) Off-preset water depth
controls
f) Gyrocompass failure
g) Failure of alarms Watch Monitoring and Alarm
System
h) Failure of power supply to distribution panel
serving relevant equipment
INTERVAL CHECKING
EXTERNAL MODE START
EXTERNAL RESET
SOUND-OFF
NO
MODE ON ?
NO
1'st Stage ?
YES WBU
YES MODE
"ON"
INTERVAL TIMER (T1)
LAMP BUZZER START (3 ~ 12 Min)
TIMER(T1)
RESET
NO
= T1 Sec ?
BRIDGE
YES LAMP INTERVAL CHECK
EMERGENCY PREWARNING
BACKUP CALL
NO
= T1 + 15 Sec ?
BRIDGE
YES BUZZER INTERVAL CHECK
NO WARNING
ICT MODE ON ?
NO
YES = T1 + 30 Sec ?
YES
NO YES
= T2 Sec ?
CAPTAIN
BUZZER BUZZER BUZZER BUZZER
BUZZER
...
CAPTAIN
BUZZER BUZZER BUZZER BUZZER BUZZER
BUZZER
...
CAPTAIN'S 1'st BACKUP 2'nd BACKUP 3'rd BACKUP n'th BACKUP PUBLIC
QUARTER CABIN CABIN CABIN CABIN ROOM
NO
ALARM ?
YES
BRIDGE
WBU
BUZZER
NO
SOUNF OFF ?
"ALARM"
DISPLAY
YES
NO
ACK ?
BRIDGE NO YES
BUZZER ACK ? ALARM TIMER START
(T3 = 15 Sec)
YES
NO
=T3 Sec ?
ACK. ALARM BRIDGE
BUZZER
YES
NO
=T4 Sec ?
INDICATOR LAMP BUZZER
YES
NO
FLICKER STEADY DARK CONTIN. PULSATING SILENCE ICT MODE ON ?
SOUND SOUND
YES
NO
=T5 Sec ?
1'st 2'nd 3'rd n'th
BACK-UP BACK-UP BACK-UP ... BACK-UP
ON ? ON ? ON ? ON ?
YES YES YES YES
CAPTAIN
BUZZER BUZZER BUZZER BUZZER
BUZZER
...
CAPTAIN
BUZZER BUZZER BUZZER BUZZER BUZZER
BUZZER
...
CAPTAIN'S 1'st BACKUP 2'nd BACKUP 3'rd BACKUP n'th BACKUP PUBLIC
QUARTER CABIN CABIN CABIN CABIN ROOM
4 SYSTEM OPERATION
Sub-Menu Window
Latest Alarm Status Window
Figure 12. Main Display
Up / Down Arrow Keys ▪ Scroll Channel List for the Selected Alarm Group
MAIN MENU
Display Operation
Display Operation
Display Operation
☞ If the Select Switch Box (Option) is installed in the captain room, the selection function of ICT On/Off
(F2) is not available on the HiWMS Bridge Unit (WBU).
Display Operation
: “Backup” Selection.
Display Operation
: Disable Scroll
: Enable Scroll
Display Operation
Display Operation
: Enable Move
: Disable Move
Display Operation
: Enable Move
: Disable Move
Display Operation
: Enable Move
: Disable Move
Display Operation
Display Operation
: “Password” Selection.
: “Supervisor” Selection.
: “User” Selection.
) Password Initialization:
Enter the “Clear Password Number” matched with the given “Password Code”, the password will be
initialized as Supervisor ‘0000’ / User ‘1111’. The “Password Code” will be randomly.
If you forget the password, contact HHI and send the given “Password Code” by mail.
And then HHI will send you a “Clear Password Number”. (E-Mail : aconis@hhi.co.kr)
) Current Password :
1. Ship’s Number is in fore – digit number : ship’s Number is possword at delivery
2. Ship’s Number is in three – digit number : ship’s Number is possword at delivery. But insert “0”
at the head of ship’s number.
(ex : H2222 – Password : 2222, H222 – Password : 0222 )
: “Timeout” Selection.
Display Operation
: “Timer 1” Selection.
: “Timer 2” Selection.
Display Operation
: “Clock” Selection.
: “Date” Selection.
: “Timer” Selection.
Display Operation
: “Index” Selection.
: “Inhibit” Selection.
▪ 1 : Normal Close
▪ 2 : Normal Open
Display Operation
Display Operation
Display Operation
5 HiWMS CONFIGURATION
ETHERNET NETWORK