You are on page 1of 1

4.

00
4.00

2.70 1.30 2.0


2.70 1.30 0 0 0
4.0
2.7
1
FCO 0.8 .20
FCO 0 0
KS 100mm Ø DP 10 1.3
.00

2.00
FD 3.0

2.00
FCO
0

100mm Ø DP

3.20
WC

3.20
FD 2.3 3.2
0 0
0.80
1.20

LAV.
UP

0.80
1.20
1.5
0
3.0
0

100mm Ø SP
2.0 0
0 0
2.7 4.0
1

100mm Ø DP
F
0.8 .20 20m 2.3
3.00

3.00
0 mØ 0 0
10.00

PVC

3.00

3.00
10
PIP
1.3

10.00
.0
0 3.0 E 1.5
0 UP SH
O .
0
CV 2.0 0
2.3 F
3.2
0
FC
0
2.7 4.0
0 O
IP E 0 1
CP
KS
PV 0.8 .20 100

mm
100mm Ø SP

1.5 0 Ø
0
20m
10 DP 1.3
2.30

2.30
0 .00

2.30

2.30
3.0 FC
3.0 O
100mm Ø DP

0 UP
0 mm
100
FC FD
ØD WC O
P
FD
E
PIP
2.3 LA 3.2
VC V.
2.3 0
ØP 0 0
m 100
20m
100
1.50

1.50

mm mm
ØS
1.5 ØD

1.50

1.50
P P
1.5 0
0
3.0
0
100 100
mm mm
ØD ØS
P P
2.3
0
2.20 1.80
1.5
0
4.00

4.00
PLUMBING LAYOUT ROOF PLUMBING LAYOUT ISOMETRIC VIEW

SPECIFICATIONS :
LENGTH
4.00 0.15 2L/3 L/3 0.15
1. ALL SANITARY WORKS HERE IN SHALL BE EXECUTED
ACCORDING TO THE PROVISIONS OF THE NATIONAL BLDG.

0.15
2.70 1.30
0.15

CODE. THE NATIONAL PLUMBING CODE AND ITS


20mm Ø PVC PIPE IMPLEMENTING RULES & REGULATIONS. CO CO

W/2
F
2. COORDINATE THE DRAWING WITH OTHER RELATED MH

WIDTH
2.00

SHO.

100mm Ø PVC Pipe


DRAWINGS & SPECIFICATIONS. THE ARCHITECT/ENGR. MANHOLE
3.20

SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY MH CO


CV 100mm Ø PVC Pipe CO

W/2
200
FOUND THEREIN. HIS/HER DECISION IS FINAL. MANHOLE

MH
0.80
1.20

F
UP
20mm Ø PVC PIPE

600
3. ALL PIPES SHALL BE INSTALLED AS INDICATED. ANY

0.15
600

RELOCATION REQUIRED FOR THE PROPER EXECUTION OF


200

PLAN OTHER TRADES SHALL BE W/ PRIOR APPROVAL OF ARCT./ENGR. PLAN


3.00

3.00

200mm CI GARDEN DRAIN 4. PROPOSED SANITARY LINES/UTILITIES SHALL CONFORM TO MH MH


10.00

PLAN
THE ACTUAL LOCATION, DEPTH, & INVERT ELEV. OF EXISTING
PIPES & STRUCTURES AS VERIFIED BY THE CONTRACTOR.

0.40
200 mm CI GARDEN DRAIN

800
1000
AIR SPACE
100mm Ø PVC Pipe 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQ'D.

200
100mm Ø PVC Pipe
800
1000

FLOOR & WALL OPENINGS. SCUM LEVEL

1.80 M.
2.30

2.30

200

SECTION
20mm Ø PVC PIPE

INLET OUTLET
DIGESTIONCHAMBER
6. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN LEACHING
SECTION 1% AS MIN. UNLESS OTHERWISE NOTED. WELL
1.50

1.50

7. ALL FIXTURES BE VENTED, UNLESS OTHERWISE NOTED.


L = 2.00 M
8. THE CONTRACTOR SHALL CONDUCT AND VALIDATE SITE
0.15 .15

CONDITION AND TAPPING POINTS. W= 3.00 M


SECTION
CATCH CASIN DETAIL 9. THE CONTRACTOR WILL COORDINATE WITH ER ADMIN PRIOR TO
START OF ANY WORK OUTSIDE OF PROPERTY.

10. THE CONTRACTOR WILL SUBJECT TO THE INSPECTION ER ADMIN.


ALL TAPPING WORKS PRIOR TO RESTORATION. SEPTIC TANK DETAIL
WATERLINE LAYOUT 11. ANY DAMAGE TO PROPERTY SHALL BE RESTORED AT THE
CONTRACTOR'S EXPENSE.

SPS. LAURO & FLORENDA L. SIOSON GROUND FLOOR PLUMBING LAYOUT


DECK PLUMBING LAYOUT -
GROUND FLOOR WATER LAYOUT
ISOMETRIC VIEW
ONE (1) STOREY SEPTIC TANK DETAIL
CATCH BASIN DETAIL
RESIDENTIAL BUILDING WITH LOFT GENERAL NOTES AND SPECIFICATIONS

B37 L2 WINWARD SUBD. BRGY. BUROL 1,DASMARINAS CITY, CAVITE


P-1

You might also like