In case of overpressure, the extinguisher agent is fully discharged outside the helicopter through the
proper discharge indicator.
Upon the discharge, the outer green disc is ejected, and a red interior circular band is exposed providing a visual indication of agent discharge that is visible during on ground inspection. To discharge the extinguisher agent into the engine bays, each bottle is provided with two outlet valves that contain an electrically actuated explosive cartridge and a frangible disc breaks The temperature compensated pressure switch monitors the pressure in the fire extinguishing bottle. This pressure switch operates when the pressure decreases more than 15% of the standard pressure. An output signal is sent to the MAU 1 and the maintenance message 2 FIRE EXTING EMPTY is shown on the Multifunction Display (MFD) for the ground personnel.
Ref to w/o HTB12256-0048 (NO2 FIRE EXTINGUSHER DISCHARGE INDICATOR WAS
FOUND DAMAGE) 30-06-2023. FAULT CODE 26202001FIR MFD MSG ON 21 NOV LEG2 ON FLIGHT 06.45 21 NOV LEG2 ON GRD 08.14 23 NOV LEG 2 ON GRD