Safety Test Report

Report No.: AGC08009200601ES01

PRODUCT DESIGNATION : USB humidifer with mood light

BRAND NAME : N/A

MODEL NAME : MO9406

APPLICANT : Mid Ocean Brands B.V.

DATE OF ISSUE : Jul. 12, 2020


EN 60335-2-80:2003+A1:2004+A2:2009,
STANDARD(S) : EN 60335-2-98:2003+A1:2005+A2:2008,
EN 60335-1:2012+A11:2014+A13:2017, EN 62233:2008

REPORT VERSIN : V1.0

Attestation of Global Compliance (Shenzhen) Co., Ltd.

CAUTION:
This report shall not be reproduced except in full without the written permission of the test
laboratory and shall not be quoted out of context.
Report No.: AGC08009200601ES01
Page 2 of 94

TEST REPORT
EN 60335-2-80, EN 60335-2-98
Household and similar electrical appliances- Safety-
Part 2-80: Particular requirements for fans
Part 2-98: Particular requirements for humidifiers
Report reference No. .......................... : AGC08009200601ES01

Tested by (+ signature) ......................: Hudson Huang

Reviewed by (+ signature) .................: Yeats Qin

Matte He
Approved by (+ signature) .................:
(Authorized officer)
Date of issue .......................................: Jul. 12, 2020
Contents ..............................................: Total 94 pages
Testing laboratory
Name...................................................: Attestation of Global Compliance (Shenzhen) Co., Ltd.

Address ...............................................: 1-2/F, Building 19, Junfeng Industrial Park, Chongqing Road, Heping
Community, Fuhai Street, Bao 'an District, Shenzhen, Guangdong, China
Testing location...................................: Same as above
Applicant
Name................................................... : Mid Ocean Brands B.V.

Address ...............................................: 7/F., King Tower, 111King Lam Street, Cheung ShaWan, Kowloon,
HongKong.
Manufacturer
Name...................................................: Mid Ocean Brands B.V.
Address ...............................................: 7/F., King Tower, 111King Lam Street, Cheung ShaWan, Kowloon,
HongKong.
Factory
Name...................................................: Mid Ocean Brands B.V.

Address ...............................................: 7/F., King Tower, 111King Lam Street, Cheung ShaWan, Kowloon,
HongKong.
Report No.: AGC08009200601ES01
Page 3 of 94

Test specification
Standard..............................................: EN 60335-2-80:2003+A1:2004+A2:2009,
EN 60335-2-98:2003+A1:2005+A2:2008,
EN 60335-1:2012+A11:2014+A13:2017, EN 62233:2008
Test procedure ...................................: Type test
Procedure deviation............................: N/A
Non-standard test method ..................: N/A

Test Report Form/blank test report


Test Report Form No. .........................: AGC60335-2-98A6
TRF originator. ....................................: AGC

Master TRF .........................................: Dated 2019-01

Test item
Product designation ...........................: USB humidifer with mood light
Brand name ........................................: N/A
Test model ..........................................: MO9406
Series models .....................................: N/A
Rating(s)..............................................: 5V 0.5A
Test case verdicts
Test case does not apply to the test object ................. : N(/A)
Test item does meet the requirement .......................... : P(ass)
Test item does not meet the requirement .................... : F(ail)
Testing
Date of receipt of test item .......................................... : Jul. 22, 2020
Date(s) of performance of test ..................................... : Jul. 22 - Jul. 12, 2020
Attachment
Attachment A ................................................................ : Photos of product
General remarks
This report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item tested.
"(see remark #)" refers to a remark appended to the report.
"(see appended table)" refers to an appended table to the report.
Throughout this report a comma is used as the decimal separator.
Report Revise Record
Report Version Revise Time Issued Date Valid Version Notes

V1.0 / Jul. 12, 2020 Valid Initial release


Report No.: AGC08009200601ES01
Page 4 of 94

General product information


The product is class III equipment, The main body of the appliance is a humidifier, with a USB output port, which
can be connected to a DC fan or LED light. It is for indoor used only.
The appliance can be LED light, it is test according to EN 60598, Refer to test report No.: AGC08009200601ES02.
Instructions and equipment marking related to safety is applied in the language that is acceptable in the country in
which the equipment is to be sold.
Summary of testing
Test items passed.
Copy of marking plate

USB humidifer with mood light


Model: MO9406
Rating: 5V 0.5A
Mid Ocean Brands B.V.
7/F., King Tower, 111King Lam Street,
Cheung ShaWan, Kowloon, HongKong.
Importer: XXXX Address: XXXX

Made In China

Remark:
1) The CE marking and WEEE symbol (if any) should be at least 5mm and 7mm respectively in height.
2) The markings and instructions are the minimum requirements required by safety standard. For final production
samples, the additional markings which do not give rise to misunderstanding may be added.
3) As declared by the applicant, the importer (and manufacturer, if it is different)’s name, registered trade name or
mark and the postal address will be marked on the products before being place on the market.
4) Marking on the packaging or in a document accompanying the electrical equipment is only acceptable if it is not
possible to place such markings on the product.
Report No.: AGC08009200601ES01
Page 5 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
5 GENERAL CONDITIONS FOR THE TESTS P
Tests performed according to clause 5, e.g. nature of P
supply, sequence of testing, etc.
5.6 Humidistats are short-circuited or rendered inoperative N
(EN 60335-2-98)
5.7 Fans to be used in tropical climates, the tests of clause N
10,11 and 13 are carried out at 40 °C +/- 2 °C (EN
60335-2-80)
Fans marked with ambient operating temperature, the N
tests of clause 10, 11 and 13 are carried out at marked
value +/- 2 °C (EN 60335-2-80)

6 CLASSIFICATION P
6.1 Protection against electric shock: Class III P
Class I, II, III ................................................................. :
6.2 Protection against harmful ingress of water N
At least IPX2 for Duct fans (EN 60335-2-80) N
6.101 Classification to climatic conditions (EN 60335-2-80): P
- fans for temperature climates P
- fans for tropical climates N

7 MARKING AND INSTRUCTIONS P


7.1 Rated voltage or voltage range (V) .............................. : 5V P
Symbol for nature of supply, or .................................... : P
Rated frequency (Hz) ................................................... : N
Rated power input (W), or ............................................ : N
Rated current (A) ......................................................... : 0.5A P
Electrode-type appliances shall be marked with their N
rated power input.(EN 60335-2-98)
Manufacturer's or responsible vendor's name, Refer to the marking plate P
trademark or identification mark ................................... :
Model or type reference ............................................... : MO9406 P
Symbol IEC 60417-5172, for class II appliances N
IP number, other than IPX0 .......................................... : N
Symbol IEC 60417-5180, for class III appliances, P
unless
Report No.: AGC08009200601ES01
Page 6 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
the appliance is operated by batteries only N
The marking of rated voltage or rated voltage range, N
for appliances intended to be connected to the supply
mains, shall cover
- 230 V for single-phase appliances; N
- 400 V for multi-phase appliances N
Symbol IEC 60417-5036, for the enclosure of N
electrically-operated water valves in external hose-
sets for connection of an appliance to the water mains,
if the working voltage exceeds extra-low voltage
Appliances manually filled have level mark or other Cannot be filled beyond N
means to indicate when they filled to their rated
capacity, unless they cannot be filled beyond this
capacity. Indication visible when appliance being filled.
(EN 60335-2-98)
If temperature of water vapour exceeds 60 °C, Water vapour no exceeds 60 °C N
appliance marked with symbol IEC 60417-5597 (2002-
10) or (EN 60335-2-98)
with substance of the following: N
CAUTION: Hot water vapour(EN 60335-2-98)
This symbol is a warning sign and the rules of ISO N
3864-1 apply. (EN 60335-2-98)
For tropical climates marked with letter T (EN 60335-2- N
80)
Fans intended for operation in location where the local N
temperature exceeds 40 °C shall be marked with the
ambient operating temperature. (EN 60335-2-80)
7.2 Warning for stationary appliances for multiple supply N
Warning placed in vicinity of terminal cover N
7.3 Range of rated values marked with the lower and N
upper limits separated by a hyphen
Different rated values marked with the values N
separated by an oblique stroke
7.4 Appliances adjustable for different rated voltages, N
the voltage setting is clearly discernible
Requirement met if frequent changes are not required N
and the rated voltage to which the appliance is to be
adjusted is determined from a wiring diagram
7.5 Appliances with more than one rated voltage or one or N
more rated voltage ranges, marked with rated input or
rated current for each rated voltage or range, unless
Report No.: AGC08009200601ES01
Page 7 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
the power input or current are related to the arithmetic N
mean value of the rated voltage range
Relation between marking for upper and lower limits of N
rated power input or rated current and voltage is clear
7.6 Correct symbols used P
Symbol for nature of supply placed next to rated P
voltage
Symbol for class II appliances placed unlikely to be N
confused with other marking
Units of physical quantities and their symbols P
according to international standardized system
N
Steam [symbol IEC 60417-5597 (2002-10)] (EN
60335-2-98)
7.7 Connection diagram fixed to appliances to be N
connected to more than two supply conductors and
appliances for multiple supply, unless
correct mode of connection is obvious N
7.8 Except for type Z attachment, terminals for connection to the supply mains indicated as N
follows:
- marking of terminals exclusively for the neutral N
conductor (letter N)
- marking of protective earthing terminals (symbol IEC N
60417-5019)
- marking not placed on removable parts N
7.9 Marking or placing of switches which may cause a N
hazard
7.10 Indications of switches on stationary appliances and P
controls on all appliances by use of figures, letters or
other visual means ................................... ................... :
This applies also to switches which are part of a P
control
If figures are used, the off position indicated by the N
figure 0
The figure 0 indicates only OFF position, unless no N
confusion with the OFF position
Devices used to start/stop operational functions of the P
appliance, if any, shall be distinguished from other
manual devices by means of shape, or size, or surface
texture, or position, etc
Report No.: AGC08009200601ES01
Page 8 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
An indication that the device has been operated shall P
be given by:
• A tactile feedback or P
• An audible and visual feedback P
A selector switch with an off-position clearly N
identifiable is allowed
An ON/OFF switch, if any, is considered a suitable N
device to stop operational functions. A plug is not
considered a suitable device to stop operational
functions, as it can be difficult to be reached by
vulnerable persons
7.11 Indication for direction of adjustment of controls P
7.12 Instructions for safe use provided P
Details concerning precautions during user P
maintenance
The instructions state that: P
- This appliance can be used by children aged from 8 P
years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved
- Children shall not play with the appliance. Cleaning P
and user maintenance shall not be made by children
without supervision
For a part of class III construction supplied from a N
detachable power supply unit, the instructions state
that the appliance is only to be used with the unit
provided
Instructions for class III appliances state that it must P
only be supplied at SELV, unless
it is a battery-operated appliance, the battery being N
charged outside the appliance
If the instructions state that the guard has to be P
removed for cleaning purposes, the instructions shall
state the substance of the following:
Ensure that the fan is switched off from the supply
mains before removing the guard.(EN 60335-2-80)
Instructions include details regarding filling, cleaning P
and descaling (EN 60335-2-98)
The instructions shall state the substance of the following: (EN 60335-2-98) P
Report No.: AGC08009200601ES01
Page 9 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
- care should be taken when using the appliance due to N
the emission of hot water vapour; (EN 60335-2-98)
- unplug the appliance during filling and cleaning. (EN P
60335-2-98)
The instructions for electrode-type appliances shall include the substance of the N
following (EN 60335-2-98):
- the composition and quantity of solution to be used N
and advice not to use an excessive amount of salt;
(EN 60335-2-98)
- the appliance is not to be operated from a d.c. supply. N
(EN 60335-2-98)
If symbol IEC 60417-5597 (2002-10) used, meaning N
explained (EN 60335-2-98/A2)
7.12.Z1 The specific instructions related to the safe operation P
of this appliance (as given in 7.12 of this standard)
shall be collated together in the front section of the
user instructions.
The height of the characters, measured on the capital P
letters, shall be at least 3 mm.
These instructions shall also be available in an P
alternative format, e.g. on a website
The installation instructions for appliances intended to N
be connected to the water mains shall state the
maximum permissible water pressure in pascals. (EN
60335-2-98)
7.12.1 Sufficient details for installation supplied P
For an appliance intended to be permanently N
connected to the water mains and not connected by a
hose-set, this is stated
The installation instructions shall include the N
substance of the following:(EN 60335-2-80)
– the model or type reference of a luminaire that may N
be installed in a fan constructed forthis purpose;
– whether the fan is intended for mounting in outside N
windows or walls (for partition fans);
– that the fan is to be installed so that the blades are N
more than 2,3 m above the floor (for fans intended to
be mounted at high level);
– that precautions must be taken to avoid the back- N
flow of gases into the room from the open flue of gas
or other fuel-burning appliances (for duct and partition
fans).
Report No.: AGC08009200601ES01
Page 10 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
7.12.2 Stationary appliances not fitted with means for N
disconnection from the supply mains having a contact
separation in all poles that provide full disconnection
under overvoltage category III, the instructions state
that means for disconnection must be incorporated in
the fixed wiring in accordance with the wiring rules
7.12.3 Insulation of the fixed wiring in contact with parts N
exceeding 50 K during clause 11; instructions state
that the fixed wiring must be protected
7.12.4 Instructions for built-in appliances: N
- dimensions of space N
- dimensions and position of supporting and fixing N
- minimum distances between parts and surrounding N
structure
- minimum dimensions of ventilating openings and N
arrangement
- connection to supply mains and interconnection of N
separate components
- allow disconnection of the appliance after installation, N
by accessible plug or a switch in the fixed wiring,
unless
a switch complying with 24.3 N
7.12.5 Replacement cord instructions, type X attachment with N
a specially prepared cord
Replacement cord instructions, type Y attachment N
Replacement cord instructions, type Z attachment N
7.12.6 Caution in the instructions for appliances incorporating N
a non-self-resetting thermal cut-out that is reset by
disconnection of the supply mains, if this cut-out is
required to comply with the standard
7.12.7 Instructions for fixed appliances stating how the N
appliance is to be fixed
7.12.8 Instructions for appliances connected to the water mains: N
- max. inlet water pressure (Pa) ................................... : N
- min. inlet water pressure, if necessary (Pa) ............... : N
Instructions concerning new and old hose-sets for N
appliances connected to the water mains by
detachable hose-sets
7.13 Instructions and other texts in an official language English P
7.14 Marking clearly legible and durable, rubbing test as P
specified
Report No.: AGC08009200601ES01
Page 11 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
7.15 Markings on a main part P
Marking clearly discernible from the outside, if P
necessary after removal of a cover
For portable appliances, cover can be removed or N
opened without a tool
For stationary appliances, name, trademark or N
identification mark and model or type reference visible
after installation
For fixed appliances, name, trademark or identification N
mark and model or type reference visible after
installation according to the instructions
Indications for switches and controls placed on or near P
the components. Marking not on parts which can be
positioned or repositioned in such a way that the
marking is misleading
Symbol IEC 60417-5597 (2002-10) or (EN 60335-2-98) N
marking relating to hot water vapour near vapour outlet N
(EN 60335-2-98)
7.16 Marking of a possible replaceable thermal link or fuse N
link clearly visible with regard to replacing the link

8 PROTECTION AGAINST ACCESS TO LIVE PARTS P


8.1 Adequate protection against accidental contact with Class III equipment, no live P
live parts parts in the appliance
8.1.1 Requirement applies for all positions, detachable parts P
removed
Lamps behind a detachable cover not removed, if N
conditions met
Insertion or removal of lamps, protection against N
contact with live parts of the lamp cap
Use of test probe B and probe 18 of IEC 61032, with a P
force not exceeding 1 N: no contact with live parts
Use of test probe B of IEC 61032 through openings, P
with a force of 20N for probe B and 10N for probe 18:
no contact with live parts
Lamps are not removed. However, during insertion or N
removal of lamps, no contact with live parts of the lamp
cap. (EN 60335-2-80)
8.1.2 Use of test probe 13 of IEC 61032, with a force not P
exceeding 1 N, through openings in class 0 appliances
and class II appliances/constructions: no contact with
live parts
Report No.: AGC08009200601ES01
Page 12 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
Test probe 13 also applied through openings in N
earthed metal enclosures having a non-conductive
coating: no contact with live parts
8.1.3 For appliances other than class II, use of test probe 41 N
of IEC 61032, with a force not exceeding 1 N: no
contact with live parts of visible glowing heating
elements
8.1.4 Accessible part not considered live if: P
- safety extra-low a.c. voltage: peak value not N
exceeding 42.4 V
- safety extra-low d.c. voltage: not exceeding 42.4 V P
- or separated from live parts by protective impedance N
If protective impedance: d.c. current not exceeding N
2 mA, and
a.c. peak value not exceeding 0.7 mA N
- for peak values over 42.4 V up to and including N
450 V, capacitance not exceeding 0,1 F
- for peak values over 450 V up to and including N
15 kV, discharge not exceeding 45 C
- for peak values over 15kV, the energy in the N
discharge not exceeding 350 mJ
8.1.5 Live parts protected at least by basic insulation before installation or assembly: N
- built-in appliances N
- fixed appliances N
- appliances delivered in separate units N
8.2 Class II appliances and constructions constructed so N
that there is adequate protection against accidental
contact with basic insulation and metal parts
separated from live parts by basic insulation only
Only possible to touch parts separated from live parts N
by double or reinforced insulation
Compliance is checked by applying the test probes of N
EN 61032
For built-in appliances and fixed appliances, the test N
probe B and probe 18 of EN 61032 are applied only
after installation
After removal of detachable parts for user maintenance N
purposes, the basic insulation of internal wiring may be
touched provided the equivalent insulating of cords
complying with IEC 60227 or IEC 60245. (EN 60335-2-
80)
Report No.: AGC08009200601ES01
Page 13 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict

9 STARTING OF MOTOR-OPERATED APPLIANCES N


Requirements and tests are specified in part 2 when N
necessary

10 POWER INPUT AND CURRENT P


10.1 Power input at normal operating temperature, rated (see appended table) N
voltage and normal operation not deviating from rated
power input by more than shown in table 1 ................. :
For electrode-type appliances, negative deviation not N
limited (EN 60335-2-98)
Test carried out at upper and lower limits of the ranges N
for appliances with one or more rated voltage ranges,
unless
the rated power input is related to the arithmetic mean N
value
Appliances are tested with shutters or similar devices N
in the open position.(EN 60335-2-80)
10.2 Current at normal operating temperature, rated (see appended table) P
voltage and normal operation not deviating from rated
current by more than shown in table 2 ..................:
Test carried out at upper and lower limits of the ranges N
for appliances with one or more rated voltage ranges,
unless
the rated current is related to the arithmetic mean N
value of the range
Appliances are tested with shutters or similar devices N
in the open position. (EN 60335-2-80)

11 HEATING P
11.1 No excessive temperatures in normal use P
11.2 The appliance is held, placed or fixed in position as P
described ...................................................................... :
11.3 Temperature rises, other than of windings, determined P
by thermocouples
Temperature rises of windings determined by N
resistance method, unless
the windings are non-uniform or it is difficult to make P
the necessary connections
Report No.: AGC08009200601ES01
Page 14 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
11.4 Heating appliances operated under normal operation N
at 1,15 times rated power input (W) ......................:
Electrode-type appliances are supplied at 1,06 times N
rated voltage (EN 60335-2-98)
If temperature rise limits exceeded in appliances N
incorporating motors, transformers or electronic circuits,
and the power input is lower than rated power input,
test repeated with appliance supplied at 1,06 times
rated voltage (EN 60335-2-98)
11.5 Motor-operated appliances operated under normal (see appended tables) P
operation at most unfavourable voltage between 0.94
and 1.06 times rated voltage (V) .................................. :
11.6 Combined appliances are operated as heating N
appliances (EN 60335-2-98)
11.7 Appliances are operated until steady conditions are P
established. (EN 60335-2-80)
11.7 Appliances are operated until steady conditions are P
established (EN 60335-2-98)
11.8 Temperature rises monitored continuously and not (see appended tables) P
exceeding the values in table 3 ................................... :
The temperature rise limits of motors, transformers and N
components of electronic circuits, including parts
directly influenced by them, exceeded when appliance
operated at 1,15 times rated power input (EN 60335-2-
98)
If the temperature rise of a motor winding exceeds the N
value of table 3, or
if there is doubt with regard to classification of N
insulation,
tests of Annex C are carried out N
Sealing compound does not flow out N
Protective devices do not operate, except P
components in protective electronic circuits tested for N
the number of cycles specified in 24.1.4
The temperature rise limits for appliances for tropical N
climates are reduced by 15 K. (EN 60335-2-80)
The temperature rise limits for fans marked with an N
ambient operating temperature are reduced by the
difference between the marked value and 25 °C. (EN
60335-2-80)
Report No.: AGC08009200601ES01
Page 15 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE P
13.1 Leakage current not excessive and electric strength P
adequate
Heating appliances operated at 1,15 times the rated N
power input (W) .....................................................:
Motor-operated appliances and combined appliances (see appended table) N
supplied at 1,06 times the rated voltage (V) .........:
Electrode-type appliances supplied at 1,06 times rated N
voltage (EN 60335-2-98)
Protective impedance and radio interference filters N
disconnected before carrying out the tests
13.2 For class 0, class II and class III appliances, leakage P
current measured by means of the circuit described in
figure 4 of IEC 60990
For other appliances, a low impedance ammeter may N
be used
Leakage current measurements .................................. : (see appended table) N
Electrode-type appliances, leakage current measured N
between metallic mesh placed in water vapour, 10 mm
from outlet, and accessible metal parts including metal
foil (EN 60335-2-98)
Leakage current not exceed 0,25 mA (EN 60335-2-98) N
13.3 The appliance is disconnected from the supply P
Electric strength tests according to table 4 .................. : (see appended table) P
No breakdown during the tests P

14 TRANSIENT OVERVOLTAGES N
Appliances withstand the transient over-voltages to N
which they may be subjected
Clearances having a value less than specified in table N
16 subjected to an impulse voltage test, the test
voltage specified in table 6 ........................................... :
No flashover during the test, unless N
of functional insulation if the appliance complies with N
clause 19 with the clearance short-circuited

15 MOISTURE RESISTANCE P
15.1 Enclosure provides the degree of moisture protection N
according to classification of the appliance
Report No.: AGC08009200601ES01
Page 16 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
Compliance checked as specified in 15.1.1, taking into N
account 15.1.2, followed by the electric strength test of
16.3
No trace of water on insulation which can result in a N
reduction of clearances or creepage distances below
values specified in clause 29
15.1.1 Appliances, other than IPX0, subjected to tests as N
specified in IEC 60529 ................................................. :
Water valves containing live parts in external hoses for N
connection of an appliance to the water mains tested
as specified for IPX7 appliances
The outer part of fans to be installed in the external N
structure is subjected to subclause 14.2.4(a) of IEC
60529:1989. The part of fans that is not mounted on the
outside surface is protected against the spray water
from the oscillating tube. (EN 60335-2-80)
The test is carried out with the appliance in the rest N
position and then in operation while supplied at rated
voltage, shutters or similar devices being in the open
position. (EN 60335-2-80)
Fans marked with the second numeral of the IP system N
are subjected to the appropriate test of IEC 60529 both
at rest and in operation while supplied at rated voltage.
(EN 60335-2-80)
15.1.2 Hand-held appliance turned continuously through the N
most unfavourable positions during the test
Built-in appliances installed according to the N
instructions
Appliances with an automatic cord reel are tested with N
the cord in the most unfavourable position in such a
way that the reeling of the wet cord may affect
electrical insulation during operation. The cord shall
not be dried before reeling
Appliances placed or used on the floor or table placed N
on a horizontal unperforated support
Appliances normally fixed to a wall and appliances N
with pins for insertion into socket-outlets are mounted
on a wooden board
For IPX3 appliances, the base of wall mounted N
appliances is placed at the same level as the pivot
axis of the oscillating tube
For IPX4 appliances, the horizontal centre line of the N
appliance is aligned with the pivot axis of the
oscillating tube, and
Report No.: AGC08009200601ES01
Page 17 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
for appliances normally used on the floor or table, the N
movement is limited to two times 90 for a period of 5
min, the support being placed at the level of the pivot
axis of the oscillating tube
Wall-mounted appliances, take into account the N
distance to the floor stated in the instructions
Appliances normally fixed to a ceiling are mounted N
underneath a horizontal unperforated support, the
pivot axis of the oscillating tube located at the level of
the underside of the support, and
for IPX4 appliances, the movement of the tube is N
limited to two times 90 from the vertical for a period of
5 min
Appliances with type X attachment fitted with a flexible N
cord as described
Detachable parts subjected to the relevant treatment N
with the main part
However, if a part has to be removed for user N
maintenance and a tool is needed, this part is not
removed
15.2 Spillage of liquid does not affect the electrical N
insulation
Appliances with type X attachment fitted with a flexible N
cord as described
Appliances incorporating an appliance inlet tested with N
or without an connector, whichever is most
unfavourable
Detachable parts are removed N
Overfilling test with additional amount of the solution, N
over a period of 1 min (l) .............................................. :
In case of doubt, the spillage test is carried out with the N
appliance deviating from the normal position of use by
an angle not exceeding 5 °(EN 60335-2-98)
Appliances intended to be connected to water mains N
operated until maximum water level reached. Inlet valve
held open and filling continued for 15 min after first
evidence of overflow or (EN 60335-2-98)
until inflow stops automatically (EN 60335-2-98) N
The appliance withstands the electric strength test of N
16.3
No trace of water on insulation that can result in a N
reduction of clearances or creepage distances below
values specified in clause 29
Report No.: AGC08009200601ES01
Page 18 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
15.3 Appliances proof against humid conditions P
Checked by test Cab: Damp heat steady state in IEC P
60068-2-78
Detachable parts removed and subjected, if P
necessary, to the humidity test with the main part
Humidity test for 48 h in a humidity cabinet 25C, 93%, 48h P
Reassembly of those parts that may have been P
removed
The appliance withstands the tests of clause 16 P

16 LEAKAGE CURRENT AND ELECTRIC STRENGTH P


16.1 Leakage current not excessive and electric strength P
adequate
Protective impedance disconnected from live parts N
before carrying out the tests
Tests carried out at room temperature and not N
connected to the supply
16.2 Single-phase appliances: test voltage 1.06 times rated (see appended table) N
voltage (V) .................................................................... :
Three-phase appliances: test voltage 1.06 times rated N
voltage divided by 3 (V) .............................................. :
Leakage current measurements .................................. : (see appended table) N
Limit values doubled if: N
- all controls have an off position in all poles, or N
- the appliance has no control other than a thermal N
cut-out, or
- all thermostats, temperature limiters and energy N
regulators do not have an off position, or
- the appliance has radio interference filters N
With the radio interference filters disconnected, the N
leakage current do not exceed limits specified ............ :
16.3 Electric strength tests according to table 7 .................. : (see appended table) P
Test voltage applied between the supply cord and inlet P
bushing and cord guard and cord anchorage as
specified ....................................................................... :
No breakdown during the tests P

17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS N


Report No.: AGC08009200601ES01
Page 19 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
No excessive temperatures in transformer or N
associated circuits in event of short-circuits likely to
occur in normal use ...................................................... :
Appliance supplied with 1.06 or 0.94 times rated N
voltage under the most unfavourable short-circuit or
overload likely to occur in normal use (V) .................... :
Basic insulation is not short-circuited N
Temperature rise of insulation of the conductors of N
safety extra-low voltage circuits not exceeding the
relevant value specified in table 3 by more than 15 K
Temperature of the winding not exceeding the value N
specified in table 8
However, limits do not apply to fail-safe transformers N
complying with sub-clause 15.5 of IEC 61558-1

18 ENDURANCE N
Requirements and tests are specified in part 2 when N
necessary

19 ABNORMAL OPERATION P
19.1 The risk of fire, mechanical damage or electric shock (see appended table) P
under abnormal or careless operation obviated
Electronic circuits so designed and applied that a fault
P
will not render the appliance unsafe ............................ :
Appliances incorporating heating elements subjected
N
to the tests of 19.2 and 19.3, and
if the appliance also has a control that limit the
temperature during clause 11 it is subjected to the test N
of 19.4, and
if applicable, to the test of 19.5 N
Appliances incorporating PTC heating elements are
N
also subjected to the test of 19.6
Appliances incorporating motors subjected to the tests
P
of 19.7 to 19.10, as applicable
Appliances incorporating electronic circuits subjected
P
to the tests of 19.11 and 19.12, as applicable
Appliances incorporating contactors or relays
subjected to the test of 19.14, being carried out before N
the tests of 19.11
Appliances incorporating voltage selector switches
N
subjected to the test of 19.15
Report No.: AGC08009200601ES01
Page 20 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
Fans incorporating shutters or similar devices N
operated by a control are also subjected to the test of
19.101.(EN 60335-2-80)
Unless otherwise specified, the tests are continued N
until a non-self-resetting thermal cut-out operates, or
until steady conditions are established P
If a heating element or intentionally weak part N
becomes open-circuited, the relevant test is repeated
on a second sample
19.2 Test of appliances with heating elements with N
restricted heat dissipation; test voltage (V), power
input of 0.85 times rated power input (W) .................... :
The container of electrode-type appliances is filled with N
a saturated solution of NaCl at 20 °C ± 5 °C, the
appliance being supplied at rated voltage.(EN 60335-2-
98)
A solution is saturated when no more salt can be N
dissolved. (EN 60335-2-98)
19.3 Test of 19.2 repeated; test voltage (V), power input of N
1.24 times rated power input (W) ................................. :
Test not applicable to electrode-type appliances N
(IEC60335-2-98)
19.4 Appliances only filled with sufficient water to cover N
heating elements (IEC60335-2-98)
Fans switched off (IEC60335-2-98) N
19.5 Test of 19.4 repeated on Class 0I and I appliances N
with tubular sheathed or embedded heating elements.
No short-circuiting, but one end of the element
connected to the sheath
The test repeated with reversed polarity and the other N
end of the heating element connected to the sheath
The test is not carried out on appliances intended to N
be permanently connected to fixed wiring and on
appliances where an all-pole disconnection occurs
during the test of 19.4
19.6 Appliances with PTC heating elements tested at rated N
voltage, establishing steady conditions
The working voltage of the PTC heating element is N
increased by 5% and the appliance is operated until
steady conditions are re-established. The voltage is
then increased in similar steps until 1.5 times working
voltage or until the PTC heating element ruptures (V) . :
Report No.: AGC08009200601ES01
Page 21 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
19.7 Stalling test by locking the rotor if the locked rotor N
torque is smaller than the full load torque, or
locking moving parts of other appliances Locked the DC fan P
Locked rotor, capacitors open-circuited one at a time N
Test repeated with capacitors short-circuited one at a N
time, unless
the capacitor is of class P2 of IEC 60252-1 N
Appliances with timer or programmer supplied with N
rated voltage for each of the tests, for a period equal
to the maximum period allowed ................................... :
Other appliances supplied with rated voltage for a P
period as specified ....................................................... :
Winding temperatures not exceeding values specified (see appended table) P
in table 8 ....................................................................... :
Mounting of separate control (EN 60335-2-80) N
Approximately 50 % of the area of each ventilating N
opening is blocked. (EN 60335-2-80)
Winding temperatures not exceeding values specified in N
table 8 (EN 60335-2-80)
The temperature rise of the board not exceed: (EN N
60335-2-80)
– 50 K, for appliances with T marking N
– 65 K, for other appliances N
19.8 Multi-phase motors operated at rated voltage with one N
phase disconnected
19.9 Running overload test on appliances incorporating N
motors intended to be remotely or automatically
controlled or liable to be operated continuously
Motor-operated and combined appliances for which N
30.2.3 is applicable and that use overload protective
devices relying on electronic circuits to protect the
motor windings, are also subjected to the test
Winding temperatures not exceeding values as N
specified ....................................................................... :
19.9 Not applicable.(EN 60335-2-80) N
19.10 Series motor operated at 1.3 times rated voltage for N
1 min (V) ....................................................................... :
During the test, parts not being ejected from the N
appliance
Report No.: AGC08009200601ES01
Page 22 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
19.11 Electronic circuits, compliance checked by evaluation N
of the fault conditions specified in 19.11.2 for all
circuits or parts of circuits, unless
they comply with the conditions specified in 19.11.1 P
Appliances incorporating an electronic circuit that N
relies upon a programmable component to function
correctly, subjected to the test of 19.11.4.8, unless
restarting does not result in a hazard N
Appliances having a device with an off position N
obtained by electronic disconnection, or a device
placing the appliance in a stand-by mode, subjected to
the tests of 19.11.4
If the safety of the appliance under any of the fault N
conditions depends on the operation of a miniature
fuse-link complying with IEC 60127, the test of 19.12
is carried out
During and after each test the following is checked: P
- the temperature of the windings do not exceed the P
values specified in table 8
- the appliance complies with the conditions specified P
in 19.13
- any current flowing through protective impedance not P
exceeding the limits specified in 8.1.4
If a conductor of a printed board becomes open-circuited, the appliance is considered to P
have withstood the particular test, provided both of the following conditions are met:
- the base material of the printed circuit board P
withstands the test of Annex E
- any loosened conductor does not reduce clearance N
or creepage distances between live parts and
accessible metal parts below the values specified in
clause 29
19.11.1 Fault conditions a) to g) in 19.11.2 are not applied to circuits or parts of circuits meeting P
both of the following conditions:
- the electronic circuit is a low-power circuit, that is, the P
maximum power at low-power points does not exceed
15 W according to the tests specified
- the protection against electric shock, fire hazard, P
mechanical hazard or dangerous malfunction of other
parts of the appliance does not rely on the correct
functioning of the electronic circuit
19.11.2 Fault conditions applied one at a time, the appliance operating under conditions N
specified in clause 11, but supplied at rated voltage, duration of the tests as specified:
Report No.: AGC08009200601ES01
Page 23 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
a) short circuit of functional insulation if clearances or N
creepage distances are less than the values specified
in clause 29
b) open circuit at the terminals of any component N
c) short circuit of capacitors, unless N
they comply with IEC 60384-14 N
d) short circuit of any two terminals of an electronic N
component, other than integrated circuits
This fault condition is not applied between the two N
circuits of an optocoupler
e) failure of triacs in the diode mode N
f) failure of microprocessors and integrated circuits N
g) failure of an electronic power switching device N
Each low power circuit is short-circuited by connecting N
the low-power point to the pole of the supply source
from which the measurements were made
19.11.3 If the appliance incorporates a protective electronic N
circuit which operates to ensure compliance with
clause 19, the relevant test is repeated with a single
fault simulated, as indicated in a) to g) of 19.11.2
19.11.4 Appliances having a device with an off position N
obtained by electronic disconnection, or
a device that can be placed in the stand-by mode, N
subjected to the tests of 19.11.4.1 to 19.11.4.7, the N
device being set in the off position or in the stand-by
mode
Appliances incorporating a protective electronic circuit N
subjected to the tests of 19.11.4.1 to 19.11.4.7, the
tests being carried out after the protective electronic
circuit has operated, except that
appliances operated for 30 s or 5 min during the test N
of 19.7 are not subjected to the tests for
electromagnetic phenomena.
Surge protective devices disconnected, unless N
They incorporate spark gaps N
19.11.4.1 The appliance is subjected to electrostatic discharges N
in accordance with IEC 61000-4-2, test level 4
19.11.4.2 The appliance is subjected to radiated fields in N
accordance with IEC 61000-4-3, test level 3
Report No.: AGC08009200601ES01
Page 24 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
19.11.4.3 The appliance is subjected to fast transient bursts in N
accordance with IEC 61000-4-4, test level 3 or 4 as
specified
19.11.4.4 The power supply terminals of the appliance subjected N
to voltage surges in accordance with IEC 61000-4-5,
test level 3 or 4 as specified
Test level 3 is applicable for the line-to-line coupling N
mode
Test level 4 is applicable for the line-to-earth coupling N
Earthed heating elements in class I appliances N
disconnected
19.11.4.5 The appliance is subjected to injected currents in N
accordance with IEC 61000-4-6, test level 3
19.11.4.6 Appliances having a rated current not exceeding 16 A N
are subjected to the Class 3 voltage dips and
interruptions in accordance with IEC 61000-4-11
Appliances having a rated current exceeding 16 A are N
subjected to the Class 3 voltage dips and interruptions
in accordance with IEC 61000-4-34
19.11.4.7 The appliance is subjected to mains signals in N
accordance with IEC 61000-4-13, test level class 2
19.11.4.8 The appliance is supplied at rated voltage and N
operated under normal operation. After 60s the power
supply is reduced to a level such that the appliance
ceases to respond or parts controlled by the
programmable component cease to operate
The appliance continues to operate normally, or N
requires a manual operation to restart N
19.12 If the safety of the appliance for any of the fault N
conditions specified in 19.11.2 depends on the
operation of a miniature fuse-link complying with
IEC 60127, the test is repeated, measuring the current
flowing through the fuse-link; measured current (A);
rated current of the fuse-link (A)................................... :
19.13 During the tests the appliance does not emit flames, P
molten metal, poisonous or ignitable gas in hazardous
amounts
Temperature rises not exceeding the values shown in (see appended table) P
table 9 ........................................................................... :
Compliance with clause 8 not impaired P
If the appliance can still be operated it complies with P
20.2
Report No.: AGC08009200601ES01
Page 25 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
Insulation, other than of class III appliances or class III constructions that do not contain N
live parts, withstands the electric strength test of 16.3, the test voltage as specified in
table 4:
- basic insulation (V) ..................................................... : N
- supplementary insulation (V) ..................................... : N
- reinforced insulation (V) ............................................. : N
After operation or interruption of a control, clearances N
and creepage distances across the functional
insulation withstand the electric strength test of 16.3,
the test voltage being twice the working voltage
The appliance does not undergo a dangerous P
malfunction, and
no failure of protective electronic circuits, if the P
appliance is still operable
Appliances tested with an electronic switch in the off position, or in the stand-by mode: N
- do not become operational, or N
- if they become operational, do not result in a N
dangerous malfunction during or after the tests of
19.11.4
If the appliance contains lids or doors that are controlled by one or more interlocks, one N
of the interlocks may be released provided that:
- the lid or door does not move automatically to an N
open position when the interlock is released, and
- the appliance does not start after the cycle in which N
the interlock was released
19.14 Appliances operated under the conditions of clause N
11, any contactor or relay contact operating under the
conditions of clause 11 being short-circuited
For a relay or contactor with more than one contact, all N
contacts are short-circuited at the same time
A relay or contactor operating only to ensure the N
appliance is energized for normal use is not short-
circuited
If more than one relay or contactor operates in clause N
11, they are short-circuited in turn
19.15 For appliances with a mains voltage selector switch, N
the switch is set to the lowest rated voltage position
and the highest value of rated voltage is applied
19.101 Fans incorporating shutters or similar that are operated N
automatically are supplied at rated voltage in the closed
or open position, whichever is more unfavourable (EN
60335-2-80)
Report No.: AGC08009200601ES01
Page 26 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict

20 STABILITY AND MECHANICAL HAZARDS P


20.1 Appliances having adequate stability P
Tilting test through an angle of 10, appliance placed Place the test according to P
on an inclined plane/horizontal support, not connected normal use, Not overturn
to the supply mains; appliance does not overturn
Tilting test repeated on appliances with heating N
elements, angle of inclination increased to 15
Possible heating test in overturned position; N
temperature rise does not exceed values shown in
table 9
Portable pedestal fans exceeding 1,7 m and exceeding <1.7m,<10 kg N
10 kg tested with a force of 40 N at 1,5 m. (EN 60335-
2-80)
20.2 Moving parts adequately arranged or enclosed as to N
provide protection against personal injury
Protective enclosures, guards and similar parts are N
non-detachable, and
have adequate mechanical strength N
When using the test probe similar to test probe B with N
a circular stop face, the accessories and detachable
covers are removed
Enclosures that can be opened by overriding an N
interlock are considered to be detachable parts
Self-resetting thermal cut-outs and overcurrent N
protective devices not causing a hazard by
unexpected closure
Test probe 18 applied with a force of 2,5N on the N
appliance fully assembled
Not possible to touch dangerous moving parts with the N
test probe described
20.101 Fan blades, other than those of fans for mounting at P
high level, shall be guarded unless their leading edges
and tips are rounded with a radius of not less than 0,5
mm and (EN 60335-2-80)
– they have a hardness less than D 60 Shore, or (EN P
60335-2-80)
– they have a peripheral speed less than 15 m/s when N
the fan is supplied at rated voltage, or (EN 60335-2-80)
– the fan has a power output not exceeding 2 W when N
supplied at rated voltage. (EN 60335-2-80)
Report No.: AGC08009200601ES01
Page 27 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict

21 MECHANICAL STRENGTH P
21.1 Appliance has adequate mechanical strength and is P
constructed as to withstand rough handling
Checked by applying 3 blows to every point of the P
enclosure like to be weak, in accordance with test Ehb
of IEC 60068-2-75, spring hammer test, with an
impact energy of 0,5 J
The appliance shows no damage impairing P
compliance with this standard, and
compliance with 8.1, 15.1 and clause 29 not impaired P
If doubt, supplementary or reinforced insulation N
subjected to the electric strength test of 16.3
If necessary, repetition of groups of three blows on a N
new sample
Appliances are also subjected to the test of 21.101 (EN N
60335-2-80)
21.2 Accessible parts of solid insulation having strength to N
prevent penetration by sharp implements
Test not applicable if the thickness of supplementary N
insulation is at least 1 mm and reinforced insulation at
least 2 mm
The insulation is tested as specified, and does N
withstand the electric strength test of 16.3
21.101 Fan guards are subjected to a push and pull force of 20 N
N applied along the axis of the motor. Dangerous
moving parts are not accessible with a test probe that is
similar to test probe B of IEC 61032, but having a
circular stop face with a diameter of 50 mm instead of
the non-circular face. (EN 60335-2-80)
The test probe is applied with a force not exceeding 5N. N
(EN 60335-2-80)
21.102 Ceiling fans have adequate strength. (EN 60335-2-80) N
Ceiling fans are mounted in accordance with the N
installation instructions. A load equal to four times the
mass of the fan is suspended from the body of the fan
for 1 min. (EN 60335-2-80)
A torque of 1 Nm is then applied to the fixed body of the N
fan for 1 min. The test is repeated with the torque
applied in the reverse direction. (EN 60335-2-80)
Report No.: AGC08009200601ES01
Page 28 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
The suspension system including any safety N
suspension system device shall not break and the fan
shall not be damaged to such an extent that
compliance with 8.1, 16.3 and Clause 29 is impaired.
(EN 60335-2-80)

22 CONSTRUCTION P
22.1 Appliance marked with the first numeral of the IP N
system, relevant requirements of IEC 60529 are
fulfilled
The enclosure defined in IEC 60529 does not include N
guards for fan blades. (EN 60335-2-80)
22.2 Stationary appliance: means to ensure all-pole disconnection from the supply being N
provided:
- a supply cord fitted with a plug, or N
- a switch complying with 24.3, or N
- a statement in the instruction sheet that a N
disconnection incorporated in the fixed wiring is to be
provided, or
- an appliance inlet N
Singe-pole switches and single-pole protective N
devices for the disconnection of heating elements in
single-phase, permanently connected class 01 and
class I appliances, connected to the phase conductor
22.3 Appliance provided with pins: no undue strain on N
socket-outlets
Applied torque not exceeding 0.25 Nm N
Pull force of 50N to each pin after the appliance has N
being placed in the heating cabinet; when cooled to
room temperature the pins are not displaced by more
than 1mm
Each pin subjected to a torque of 0.4Nm; the pins are N
not rotating, unless
rotating does not impair compliance with this standard N
22.4 Appliance for heating liquids and appliance causing N
undue vibration not provided with pins for insertion into
socket-outlets
22.5 No risk of electric shock when touching the pins of the N
plug, for appliances having a capacitor with rated
capacitance exceeding 0,1F, the appliance being
disconnected from the supply at the instant of voltage
peak
Report No.: AGC08009200601ES01
Page 29 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
Voltage not exceeding 34 V (V) ................................... : N
22.6 Electrical insulation not affected by condensing water N
or leaking liquid
Electrical insulation of Class II appliances not affected N
if a hose ruptures or seal leaks
In case of doubt, test as described N
Drain holes be at least 5 mm in diameter or 20 mm²in N
area with minimum dimension of at least 3 mm
(IEC60335-2-98)
22.7 Adequate safeguards against the risk of excessive N
pressure in appliances containing liquid or gases or
having steam-producing devices
22.8 Electrical connections not subject to pulling during N
cleaning of compartments to which access can be
gained without the aid of a tool, and that are likely to
be cleaned in normal use
22.9 Insulation, internal wiring, windings, commutators and N
slip rings not exposed to oil, grease or similar
substances, unless
the substance has adequate insulating properties N
22.10 Not possible to reset voltage-maintained non-self- N
resetting thermal cut-outs by the operation of an
automatic switching device incorporated within the
appliance, if:
- a non-self-resetting thermal cut-out is required by the N
standard, and
- a voltage maintained non-self-resetting thermal cut- N
out is used to meet it
Non-self-resetting thermal motor protectors have a N
trip-free action, unless
they are voltage maintained N
Reset buttons of non-self-resetting controls so located N
or protected that accidental resetting is unlikely
22.11 Reliable fixing of non-detachable parts that provide the P
necessary degree of protection against electric shock,
moisture or contact with moving parts
Obvious locked position of snap-in devices used for N
fixing such parts
No deterioration of the fixing properties of snap-in N
devices used in parts that are likely to be removed
during installation or servicing
Tests as described P
Report No.: AGC08009200601ES01
Page 30 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
The 50 N force is not applied to clips used to fasten fan N
guards. (EN 60335-2-80)
Instead, a force of 15 N is applied in any direction to the N
clips in an attempt to release them. (EN 60335-2-80)
22.12 Handles, knobs etc. fixed in a reliable manner N
Fixing in wrong position of handles, knobs etc. N
indicating position of switches or similar components
not possible
Axial force 15 N applied to parts, the shape being so N
that an axial pull is unlikely to be applied
Axial force 30 N applied to parts, the shape being so N
that an axial pull is likely to be applied
22.13 Unlikely that handles, when gripped as in normal use, N
make the operator’s hand touch parts having a
temperature rise exceeding the value specified for
handles which are held for short periods only
22.14 No ragged or sharp edges creating a hazard for the P
user in normal use, or during user maintenance
No exposed pointed ends of self-tapping screws or P
other fasteners, likely to be touched by the user in
normal use or during user maintenance
22.15 Storage hooks and the like for flexible cords smooth N
and well rounded
22.16 Automatic cord reels cause no undue abrasion or N
damage to the sheath of the flexible cord, no breakage
of conductors strands and no undue wear of contacts
Cord reel tested with 6000 operations, as specified N
Electric strength test of 16.3, voltage of 1000 V N
applied
22.17 Spacers not removable from the outside by hand or by N
means of a screwdriver or a spanner
22.18 Current-carrying parts and other metal parts resistant P
to corrosion
22.19 Driving belts not relied upon to provide the required N
level of insulation, unless
constructed to prevent inappropriate replacement N
22.20 Direct contact between live parts and thermal N
insulation effectively prevented, unless
material used is non-corrosive, non-hygroscopic and N
non-combustible
Report No.: AGC08009200601ES01
Page 31 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
22.21 Wood, cotton, silk, ordinary paper and fibrous or P
hygroscopic material not used as insulation, unless
impregnated N
This requirement does not apply to magnesium oxide N
and mineral ceramic fibres used for the electrical
insulation of heating elements
22.22 Appliances not containing asbestos P
22.23 Oils containing polychlorinated biphenyl (PCB) not P
used
22.24 Bare heating elements, except in class III appliances N
or class III constructions that do not contain live parts,
adequately supported
In case of rupture, the heating conductor is unlikely to N
come in contact with accessible metal parts
22.25 Sagging heating conductors, except in class III N
appliances or class III constructions that do not
contain live parts, cannot come into contact with
accessible metal parts
22.26 For class III constructions the insulation between parts P
operating at safety extra-low voltage and other live
parts complies with the requirements for double or
reinforced insulation
22.27 Parts connected by protective impedance separated N
by double or reinforced insulation
22.28 Metal parts of Class II appliances conductively N
connected to gas pipes or in contact with water,
separated from live parts by double or reinforced
insulation
22.29 Class II appliances permanently connected to fixed N
wiring so constructed that the required degree of
access to live parts is maintained after installation
22.30 Parts serving as supplementary or reinforced N
insulation fixed so that they cannot be removed
without being seriously damaged, or
so constructed that they cannot be replaced in an N
incorrect position, and so that if they are omitted, the
appliance is rendered inoperable or manifestly
incomplete
22.31 Neither clearances nor creepage distances over N
supplementary and reinforced insulation reduced
below values specified in clause 29 as a result of wear
Report No.: AGC08009200601ES01
Page 32 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
Neither clearances nor creepage distances between N
live parts and accessible parts reduced below values
for supplementary insulation if wires, screws etc.
become loose
22.32 Supplementary and reinforced insulation constructed N
or protected against pollution so that clearances or
creepage distances are not reduced below the values
in clause 29
Supplementary insulation of natural or synthetic N
rubber resistant to ageing, or arranged and
dimensioned so that creepage distances are not
reduced below values specified in 29.2
Ceramic material not tightly sintered, similar materials N
or beads alone not used as supplementary or
reinforced insulation
Insulating material in which heating conductors are N
embedded is considered to be basic insulation, not
reinforced insulation
Oxygen bomb test at 70 C for 96 h and 16 h at room N
temperature
22.33 Conductive liquids that are or may become accessible N
in normal use and conductive liquids that are in
contact with unearthed accessible metal parts are not
in direct contact with live parts, or
Liquids heated by using electrodes and in direct contact N
with their live parts (EN 60335-2-98)
For class II constructions, conductive liquids that are N
or may become accessible in normal use and
conductive liquids that are in contact with unearthed
accessible metal parts, not in direct contact with basic
or reinforced insulation, unless
the reinforced insulation consists of at least 3 layers N
For class II constructions, conductive liquids which are N
in contact with live parts, not in direct contact with
reinforced insulation, unless
the reinforced insulation consists of at least 3 layers N
An air layer not used as basic or supplementary N
insulation in a double insulation system if likely to be
bridged by leaking liquid
22.34 Shafts of operating knobs, handles, levers etc. not N
live, unless
the shaft is not accessible when the part is removed N
Report No.: AGC08009200601ES01
Page 33 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
22.35 For other than class III constructions, handles, levers N
and knobs, held or actuated in normal use, not
becoming live in the event of a failure of basic
insulation
Such parts being of metal, and their shafts or fixings N
are likely to become live in the event of a failure of
basic insulation, are either adequately covered by
insulation material or their accessible parts are
separated from their shafts or fixings by
supplementary insulation
This requirement does not apply to handles, levers N
and knobs on stationary appliances and cordless
appliances, other than those of electrical components,
provided they are reliably connected to an earthing
terminal or earthing contact, or separated from live
parts by earthed metal
Insulating material covering metal handles, levers and N
knobs withstand the electric strength test of 16.3 for
supplementary insulation
22.36 For appliances other than class III, handles N
continuously held in the hand in normal use so
constructed that when gripped as in normal use, the
operators hand is not likely to touch metal parts,
unless
they are separated from live parts by double or N
reinforced insulation
22.37 Capacitors in Class II appliances not connected to N
accessible metal parts and their casings, if of metal,
separated from accessible metal parts by
supplementary insulation, unless
the capacitors comply with 22.42 N
22.38 Capacitors not connected between the contacts of a N
thermal cut-out
22.39 Lamp holders used only for the connection of lamps N
22.40 Motor-operated appliances and combined appliances N
intended to be moved while in operation, or having
accessible moving parts, fitted with a switch to control
the motor. The actuating member of the switch being
easily visible and accessible
If the appliance cannot operate continuously, N
automatically or remotely without giving rise to a
hazard, appliances for remote operation being fitted
with a switch for stopping the operation. The actuating
member of the switch being easily visible and
accessible
Report No.: AGC08009200601ES01
Page 34 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
22.41 No components, other than lamps, containing mercury No components containing P
mercury
22.42 Protective impedance consisting of at least two N
separate components
Values specified in 8.1.4 not exceeded if any one of N
the components are short-circuited or open-circuited
Resistors checked by the test of 14.1 a) in IEC 60065 N
Capacitors checked by the tests for class Y capacitors N
in IEC 60384-14
22.43 Appliances adjustable for different voltages, accidental N
changing of the setting of the voltage unlikely to occur
22.44 Appliances not having an enclosure that is shaped or P
decorated like a toy
22.45 When air is used as reinforced insulation, clearances N
not reduced below the values specified in 29.1.3 due
to deformation as a result of an external force applied
to the enclosure
22.46 For programmable protective electronic circuits used N
to ensure compliance with the standard, the software
contains measures to control the fault/error conditions
in table R.1
Software that contains measures to control the N
fault/error conditions specified in table R.2 is to be
specified in parts 2 for particular constructions or to
address specific hazards
These requirements are not applicable to software N
used for functional purpose or compliance with clause
11
22.47 Appliances connected to the water mains withstand N
the water pressure expected in normal use
No leakage from any part, including any inlet water N
hose
22.48 Appliances connected to the water mains constructed N
to prevent backsiphonage of non-potable water
22.49 For remote operation, the duration of operation is to N
be set before the appliance can be started, unless
the appliance switches off automatically or can P
operate continuously without hazard
22.50 Controls incorporated in the appliance take priority P
over controls actuated by remote operation
Report No.: AGC08009200601ES01
Page 35 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
22.51 There is a control on the appliance manually adjusted P
to the setting for remote operation before the
appliance can be operated in this mode
There is a visual indication showing that the appliance P
is adjusted for remote operation
These requirements not necessary on appliances that can operate as follows, without P
giving rise to a hazard:
- continuously, or P
- automatically, or N
- remotely N
22.52 Socket-outlets on appliances accessible to the user in N
accordance with the socket-outlet system used in the
country in which the appliance is sold
22.101 Appliances having provision for attaching a luminaire N
shall incorporate appropriate terminals and internal
wiring (EN 60335-2-80)
22.101 Vapour outlet of appliances incorporating means for N
heating water be free from obstructions that could give
rise to a significant pressure within container (EN
60335-2-98)
Container vented to atmosphere, aperture being at N
least 5 mm in diameter or 20 mm²in area with minimum
dimension of at least 3 mm (EN 60335-2-98)
22.102 Appliances for wall mounting have reliable provision for N
fixing to wall, independent of connection to water mains
(EN 60335-2-98)
22.103 Electrode-type appliances so constructed to ensure that N
when filling aperture of container is open, both
electrodes disconnected to provide all-pole
disconnection under overvoltage category III conditions
(EN 60335-2-98)
This requirement not apply to an appliance that requires N
withdrawal of an appliance connector in order to gain
access to filling aperture (EN 60335-2-98/A1)
22.104 Appliances intended to be connected to water mains N
withstand water pressure expected in normal use (EN
60335-2-98)
Compliance is checked by connecting the appliance to N
a water supply having a pressure equal to twice the
maximum inlet water pressure or 1,2 MPa, whichever
is the higher, for a period of 5 min. (EN 60335-2-98)
There shall be no leakage. (EN 60335-2-98) N
Report No.: AGC08009200601ES01
Page 36 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
23 INTERNAL WIRING P
23.1 Wireways smooth and free from sharp edges P
Wires protected against contact with burrs, cooling fins P
etc.
Wire holes in metal well-rounded or provided with N
bushings
Wiring effectively prevented from coming into contact P
with moving parts
23.2 Beads etc. on live wires cannot change their position, N
and are not resting on sharp edges
Beads inside flexible metal conduits contained within N
an insulating sleeve
23.3 Electrical connections and internal conductors P
movable relatively to each other not exposed to undue
stress
Flexible metallic tubes not causing damage to N
insulation of conductors
Open-coil springs not used N
Adequate insulating lining provided inside a coiled N
spring, the turns of which touch one another
No damage after 10 000 flexings for conductors flexed N
during normal use, or
100 flexings for conductors flexed during user N
maintenance
Electric strength test of 16.3, 1000 V between live N
parts and accessible metal parts
Not more than 10% of the strands of any conductor N
broken, and
not more than 30% for wiring supplying circuits that N
consume no more than 15W
Instead of moving the movable part backwards and N
forwards, fans with an oscillatingmechanism are
tested as follows.(EN 60335-2-80)
Fans with an oscillating mechanism influencing wiring, N
the conductors shall show no damage after
100 000 cycles of flexing at rated voltage and operated
under normal operation , the angle being the maximum
allowed by the construction (EN 60335-2-80)
23.4 Bare internal wiring sufficiently rigid and fixed N
Report No.: AGC08009200601ES01
Page 37 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
23.5 The insulation of internal wiring subjected to the P
supply mains voltage withstanding the electrical
stress likely to occur in normal use
Basic insulation electrically equivalent to the basic P
insulation of cords complying with IEC 60227 or IEC
60245, or
no breakdown when a voltage of 2000 V is applied for N
15 min between the conductor and metal foil wrapped
around the insulation
23.6 Sleeving used as supplementary insulation on internal N
wiring retained in position by clamping at both ends, or
be such that it can only be removed by breaking or N
cutting
23.7 The colour combination green/yellow only used for N
earthing conductors
23.8 Aluminium wires not used for internal wiring P
23.9 Stranded conductors not consolidated by soldering N
where they are subjected to contact pressure, unless
the contact pressure is provided by spring terminals N
23.10 The insulation and sheath of internal wiring, N
incorporated in external hoses for the connection of an
appliance to the water mains, at least equivalent to
that of light polyvinyl chloride sheathed flexible cord
(60227 IEC 52)

24 COMPONENTS P
24.1 Components comply with safety requirements in P
relevant standards
List of components ....................................................... : (see appended table) P
Motors not required to comply with IEC 60034-1 P
The requirements of Clause 29 apply between live N
parts of components and accessible parts of the
appliance
The requirements of 30.2 of this standard apply to P
parts of non-metallic material in components including
parts of non-metallic material supporting current-
carrying connections inside components
Components that have not been previously tested to P
comply with the IEC standard for the relevant
component are tested according to the requirements
of 30.2
Report No.: AGC08009200601ES01
Page 38 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
Components that have been previously tested and P
shown to comply with the resistance to fire
requirements in the standard for the relevant
component need not be retested provided that:
- the severity specified in the component standard is P
not less than the severity specified in 30.2, and
- the test report for the component states whether it P
complied with the standard for the relevant component
with or without flame, flames not exceeding 2 s during
the test are ignored
Unless components have been previously tested and N
found to comply with the relevant standard for the
number of cycles specified, they are tested in
accordance with 24.1.1 to 24.1.9
For components mentioned in 24.1.1 to 24.1.9, no N
additional tests specified in the relevant standard for
the component are necessary other than those
specified in 24.1.1 to 24.1.9
Components that have not been separately tested and P
found to comply with the relevant standard, and
are tested in accordance with the conditions occurring P
in the appliance, the number of samples being that
required by the relevant standard
Lampholders and starterholders that have not being N
tested and found to comply with the relevant IEC
standard, tested as a part of the appliance and
additionally according to the gauging and
interchangeability requirements of the relevant IEC
standard
Where the relevant standard specifies these gauging N
and interchangeability requirements at elevated
temperatures, the temperatures measured during the
tests of Clause 11 are used
Plugs and socket-outlets and other connecting devices N
of interconnection cords are not interchangeable with
plugs and socket-outlets listed in IEC/TR 60083 or IEC
60906-1, or
with connectors and appliance inlets complying with N
the standard sheets of IEC 60320-1
if direct supply to these parts from the supply mains N
gives rise to a hazard
24.1.1 Capacitors likely to be permanently subjected to the N
supply voltage and used for radio interference
suppression or for voltage dividing, comply with IEC
60384-14
Report No.: AGC08009200601ES01
Page 39 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
If the capacitors have to be tested, they are tested N
according to Annex F
24.1.2 Safety isolating transformers comply with IEC 61558- N
2-6
If they have to be tested, they are tested according to N
Annex G
24.1.3 Switches comply with IEC 61058-1, the number of N
cycles of operation being at least 10 000
If they have to be tested, they are tested according to N
Annex H
If the switch operates a relay or contactor, the N
complete switching system is subjected to the test
If the switch only operates a motor staring relay N
complying with IEC 60730-2-10 with the number of
cycles of a least 10 000 as specified, the complete
switching system need not be tested
24.1.4 Automatic controls comply with IEC 60730-1 with the relevant part 2. The number of N
cycles of operation being at least:
- thermostats: 10 000 N
- temperature limiters: 1 000 N
- self-resetting thermal cut-outs: 300 N
- voltage maintained non-self-resetting 1 000 N
thermal cut-outs:
- other non-self-resetting thermal cut-outs: 30 N
- timers: 3 000 N
- energy regulators: 10 000 N
The number of cycles for controls operating during N
clause 11 need not be declared, if the appliance
meets the requirements of this standard when they are
short-circuited
Thermal motor protectors are tested in combination N
with their motor under the conditions specified in
Annex D
For water valves containing live parts and that are N
incorporated in external hoses for connection of an
appliance to the water mains, the degree of protection
declared for subclause 6.5.2 of IEC 60730-2-8 is IPX7
24.1.5 Appliance couplers comply with IEC 60320-1 N
However, for class II appliances classified higher than N
IPX0, the appliance couplers comply with IEC 60320-
2-3
Report No.: AGC08009200601ES01
Page 40 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
Interconnection couplers comply with IEC 60320-2-2 N
24.1.6 Small lamp holders similar to E10 lampholders comply N
with IEC 60238, the requirements for E10 lampholders
being applicable
24.1.7 If the remote operation of the appliance is via a N
telecommunication network, the relevant standard for
the telecommunication interface circuitry in the
appliance is EN 41003.
Compliance with Clause 8 of this standard shall not be N
impaired by connecting the appliance to a device
covered by EN 41003
24.1.8 The relevant standard for thermal links is IEC 60691 N
Thermal links not complying with IEC 60691 are N
considered to be an intentionally weak part for the
purposes of Clause 19
24.1.9 Contactors and relays, other than motor starting N
relays, tested as part of the appliance
They are also tested in accordance with Clause 17 of N
IEC 60730-1, the number of cycles of operations in
24.1.4 selected according to the contactor or relay
function in the appliance .............................................. :
24.2 Appliances not fitted with: N
- switches or automatic controls in flexible cords N
- devices causing the protective device in the fixed N
wiring to operate in the event of a fault in the
appliance
- thermal cut-outs that can be reset by soldering, N
unless
the solder has a melding point of at least 230 ˚C N
Appliances having a rated power input not exceeding N
25 W may be fitted with a switch in the supply
cord.(EN 60335-2-80)
24.3 Switches intended for all-pole disconnection of N
stationary appliances are directly connected to the
supply terminals and have a contact separation in all
poles, providing full disconnection under overvoltage
category III conditions
24.4 Plugs and socket-outlets for extra-low voltage circuits N
and heating elements, not interchangeable with plugs
and socket-outlets listed in IEC/TR 60083 or IEC
60906-1 or with connectors and appliance inlets
complying with the standard sheets of IEC 60320-1
Report No.: AGC08009200601ES01
Page 41 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
24.5 Capacitors in auxiliary windings of motors marked with N
their rated voltage and capacitance, and used
accordingly
Voltage across capacitors in series with a motor N
winding does not exceed 1,1 times rated voltage,
when the appliance is supplied at 1,1 times rated
voltage under minimum load
24.6 Working voltage of motors connected to the supply N
mains and having basic insulation that is inadequate
for the rated voltage of the appliance, not exceeding
42 V
In addition, the motors comply with the requirements N
of Annex I
24.7 Detachable hose-sets for connection of appliances to N
the water mains comply with IEC 61770
They are supplied with the appliance N
Appliances intended to be permanently connected to N
the water mains not connected by a detachable hose-
set
24.8 Motor running capacitors in appliances for which N
30.2.3 is applicable and that are permanently
connected in series with a motor winding, not causing
a hazard in event of a failure
One or more of the following conditions are to be met: N
- the capacitors are of class P2 according to IEC N
60252-1
- the capacitors are housed within a metallic or N
ceramic enclosure
- the distance of separation of the outer surface to N
adjacent non-metallic parts exceeds 50 mm
- adjacent non-metallic parts within 50 mm withstand N
the needle-flame test of Annex E
- adjacent non-metallic parts within 50 mm classified N
as at least V-1 according to IEC 60695-11-10
24.Z1 For motor running capacitors (IEC 60252-1 type P2) N
with a metallic enclosure having an overpressure fuse
the flame testing of internal plastic parts supporting
current carrying connections as required in 30.2.2 and
30.2.3.1 is not necessary
24.101 Thermal cut-outs incorporated in duct fans in order to N
comply with cl. 19 are not self-resetting (EN 60335-2-
80)
Report No.: AGC08009200601ES01
Page 42 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
24.101 Thermal cut-outs incorporated in appliances for N
compliance with clause 19 not be self-resetting (EN
60335-2-98)

25 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS N


25.1 Appliance not intended for permanent connection to fixed wiring, means for connection N
to the supply:
- supply cord fitted with a plug Class III product N
- an appliance inlet having at least the same degree of N
protection against moisture as required for the
appliance, or
- pins for insertion into socket-outlets N
25.2 Appliance not provided with more than one means of N
connection to the supply mains
Stationary appliance for multiple supply may be N
provided with more than one means of connection,
provided electric strength test of 1250 V for 1 min
between each means of connection causes no
breakdown
25.3 Appliance intended to be permanently connected to fixed wiring provided with one of the N
following means for connection to the supply mains:
- a set of terminals allowing the connection of a N
flexible cord
- a fitted supply cord N
- a set of supply leads accommodated in a suitable N
compartment
- a set of terminals for the connection of cables of N
fixed wiring, cross-sectional areas specified in 26.6,
and the appliance allows the connection of the supply
conductors after the appliance has been fixed to its
support
- a set of terminals and cable entries, conduit entries, N
knock-outs or glands, allowing connection of
appropriate types of cable or conduit, and the
appliance allows the connection of the supply
conductors after the appliance has been fixed to its
support
For a fixed appliance constructed so that parts can be N
removed to facilitate easy installation, this requirement
is met if it is possible to connect the fixed wiring
without difficulty after a part of the appliance has been
fixed to its support
Report No.: AGC08009200601ES01
Page 43 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
25.4 Cable and conduit entries, rated current of appliance N
not exceeding 16 A, dimension according to table 10
(mm) ............................................................................. :
Introduction of conduit or cable does not reduce N
clearances or creepage distances below values
specified in clause 29
25.5 Method for assembling the supply cord to the appliance: N
- type X attachment N
- type Y attachment N
- type Z attachment, if allowed in relevant part 2 N
- type Z attachment is allowed for portable fans (EN N
60335-2-80)
Type X attachment, other than those with a specially N
prepared cord, not used for flat twin tinsel cords
For multi-phase appliances supplied with a supply N
cord and that are intended to be permanently
connected to fixed wiring, the supply cord is
assembled to the appliance by type Y attachment
25.6 Plugs fitted with only one flexible cord N
Supply cords of single-phase portable appliances N
having a rated current not exceeding 16 A shall be
fitted with a plug complying with the following standard
sheets of IEC/TR 60083
- for class I appliances N
- for class II appliances N
25.7 Supply cords, other than for class III appliances, being one of the following types: N
- rubber sheathed (at least 60245 IEC 53) N
Their properties shall be at least those of ordinary N
tough rubber sheathed cords (code designation
60245 IEC 53). These cords are not suitable for
appliances intended to be used outdoors or when they
are liable to be exposed to significant amounts of
ultraviolet radiation
- polychloroprene sheathed (at least 60245 IEC 57) N
- Cross-linked polyvinyl chloride sheathed (at least N
60245 IEC 88)
- polyvinyl chloride sheathed. Not used if they are likely to touch metal parts having a N
temperature rise exceeding 75 K during the test of clause 11
 light polyvinyl chloride sheathed cord (60227 N
IEC 52), for appliances not exceeding 3 kg
Report No.: AGC08009200601ES01
Page 44 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
 ordinary polyvinyl chloride sheathed cord N
(60227 IEC 53), for other appliances
- heat resistant polyvinyl chloride sheathed. Not used for type X attachment other than N
specially prepared cords
 heat-resistant light polyvinyl chloride sheathed N
cord (60227 IEC 56), for appliances not
exceeding 3 kg
 heat-resistant polyvinyl chloride sheathed cord N
(60227 IEC 57), for other appliances
Supply cords for class III appliances adequately N
insulated
Test with 500 V for 2 min for supply cords of class III N
appliances that contain live parts
- Halogen-free thermoplastic compound sheathed N
shall be at least those of
 •halogen-free thermoplastic compound N
sheathed cords (code designation
H03Z1Z1H2-F, H03Z1Z1-F), for appliances
having a mass not exceeding 3 kg;
 •halogen-free thermoplastic compound N
sheathed cords (code designation
H05Z1Z1H2-F or H05Z1Z1-F), for other
appliances
- Cross-linked halogen-free compound sheathed N
Their properties shall be at least those of cross-linked N
halogen-free compound sheathed cords (code
designation H07ZZ-F).
25.8 Nominal cross-sectional area of supply cords not less N
than table 11; rated current (A); cross-sectional area
(mm²)............................................................................ :
25.9 Supply cords not in contact with sharp points or edges N
25.10 Supply cord of class I appliances have a green/yellow N
core for earthing
25.11 Conductors of supply cords not consolidated by N
soldering where they are subject to contact pressure,
unless
the contact pressure is provided by spring terminals N
25.12 Insulation of the supply cord not damaged when N
moulding the cord to part of the enclosure
25.13 Inlet openings so constructed as to prevent damage to N
the supply cord
Report No.: AGC08009200601ES01
Page 45 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
Unless the enclosure at the inlet opening is insulating N
material, a non-detachable lining or bushing complying
with 29.3 for supplementary insulation provided
If unsheathed supply cord, a similar additional bushing N
or lining is required, unless the appliance is
class 0, or N
a class III appliance not containing live parts N
25.14 Supply cords moved while in operation adequately N
protected against excessive flexing
Flexing test, as described: N
- applied force (N)......................................................... : N
- number of flexings ...................................................... : N
The test does not result in: N
- short-circuit between the conductors, such that the N
current exceeds a value of twice the rated current
- breakage of more than 10% of the strands of any N
conductor
- separation of the conductor from its terminal N
- loosening of any cord guard N
- damage to the cord or the cord guard N
- broken strands piercing the insulation and becoming N
accessible
25.15 For appliances with supply cord and appliances to be N
permanently connected to fixed wiring by a flexible
cord, conductors of the supply cord relieved from
strain, twisting and abrasion by use of cord anchorage
The cord cannot be pushed into the appliance to such N
an extent that the cord or internal parts of the
appliance can be damaged
Pull and torque test of supply cord, values shown in N
table 12: mass (kg); pull (N); torque (not on automatic
cord reel) (Nm) ............................................................. :
Cord not damaged and max. 2 mm displacement of N
the cord
25.16 Cord anchorages for type X attachments constructed and located so that: N
- replacement of the cord is easily possible N
- it is clear how the relief from strain and the N
prevention of twisting are obtained
- they are suitable for different types of supply cord N
Report No.: AGC08009200601ES01
Page 46 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
- cord cannot touch the clamping screws of cord N
anchorage if these screws are accessible, unless
they are separated from accessible metal parts by N
supplementary insulation
- the cord is not clamped by a metal screw which N
bears directly on the cord
- at least one part of the cord anchorage securely fixed N
to the appliance, unless
it is part of a specially prepared cord N
- screws which have to be operated when replacing N
the cord do not fix any other component, unless
the appliance becomes inoperative or incomplete or N
the parts cannot be removed without a tool
- if labyrinths can be bypassed the test of 25.15 is N
nevertheless withstood
- for class 0, 0I and I appliances they are of insulating N
material or are provided with an insulating lining,
unless
failure of the insulation of the cord does not make N
accessible metal parts live
- for class II appliances they are of insulating material, N
or
if of metal, they are insulated from accessible metal N
parts by supplementary insulation
After the test of 25.15, under the conditions specified, N
the conductors have not moved by more than 1 mm in
the terminals
25.17 Adequate cord anchorages for type Y and Z N
attachment, test with the cord supplied with the
appliance
25.18 Cord anchorages only accessible with the aid of a tool, N
or
Constructed so that the cord can only be fitted with the N
aid of a tool
25.19 Type X attachment, glands not used as cord N
anchorage in portable appliances
Tying the cord into a knot or tying the cord with string N
not used
25.20 The insulated conductors of the supply cord for type Y N
and Z attachment insulated from accessible metal
parts
Report No.: AGC08009200601ES01
Page 47 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
25.21 Space for supply cord for type X attachment or for connection of fixed wiring N
constructed:
- to permit checking of conductors with respect to N
correct positioning and connection before fitting any
cover
- so there is no risk of damage to the conductors or N
their insulation when fitting the cover
- for portable appliances, so that the uninsulated end N
of a conductor, if it becomes free from the terminal,
prevented from contact with accessible metal parts
2 N test to the conductor for portable appliances; no N
contact with accessible metal parts
25.22 Appliance inlets: N
- live parts not accessible during insertion or removal N
Requirement not applicable to appliance inlets N
complying with IEC 60320-1
- connector can be inserted without difficulty N
- the appliance is not supported by the connector N
- not for cold conditions if temp. rise of external metal N
parts exceeds 75 K during clause 11, unless
the supply cord is unlikely to touch such metal parts N
25.23 Interconnection cords comply with the requirements N
for the supply cord, except that:
- the cross-sectional area of the conductors is N
determined on the basis of the maximum current
during clause 11
- the thickness of the insulation may be reduced N
If necessary, electric strength test of 16.3 N
25.24 Interconnection cords not detachable without the aid N
of a tool if compliance with this standard is impaired
when they are disconnected
25.25 Dimensions of pins that are inserted into socket- N
outlets compatible with the dimensions of the relevant
socket-outlet.
Dimensions of pins and engagement face in N
accordance with the dimensions of the relevant plug in
IEC/TR 60083

26 TERMINALS FOR EXTERNAL CONDUCTORS P


Report No.: AGC08009200601ES01
Page 48 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
26.1 Appliances provided with terminals or equally effective P
devices for connection of external conductors
Terminals only accessible after removal of a non- N
detachable cover, except
for class III appliances that do not contain live parts P
Earthing terminals may be accessible if a tool is N
required to make the connections and means are
provided to clamp the wire independently from its
connection
26.2 Appliances with type X attachment and appliances for N
the connection of cables to fixed wiring provided with
terminals in which connections are made by means of
screws, nuts or similar devices, unless
the connections are soldered N
Screws and nuts not used to fix any other component, N
except
internal conductors, if so arranged that they are N
unlikely to be displaced when fitting the supply
conductors
If soldered connections used, the conductor so N
positioned or fixed that reliance is not placed on
soldering alone, unless
barriers provided so that neither clearances nor N
creepage distances between live parts and other
metal parts reduced below the values for
supplementary insulation if the conductor becomes
free at the soldered joint
26.3 Terminals for type X attachment and for connection of N
cables of fixed wiring so constructed that the
conductor is clamped between metal surfaces with
sufficient contact pressure but without damaging the
conductor
Terminals fixed so that when the clamping means is tightened or loosened: N
- the terminal does not become loose N
- internal wiring is not subjected to stress N
- neither clearances nor creepage distances are N
reduced below the values in clause 29
Compliance checked by inspection and by the test of N
subclause 9.6 of IEC 60999-1, the torque applied
being equal to two-thirds of the torque specified (Nm) :
No deep or sharp indentations of the conductors N
Report No.: AGC08009200601ES01
Page 49 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
26.4 Terminals for type X attachment, except those having N
a specially prepared cord and those for the connection
of cables of fixed wiring, no special preparation of
conductors such as by soldering, use of cable lugs,
eyelets or similar, and
so constructed or placed that conductors prevented N
from slipping out when clamping screws or nuts are
tightened
26.5 Terminals for type X attachment so located or shielded N
that if a wire of a stranded conductor escapes, no risk
of accidental connection to other parts that result in a
hazard
Stranded conductor test, 8 mm insulation removed N
No contact between live parts and accessible metal N
parts and,
for class II constructions, between live parts and metal N
parts separated from accessible metal parts by
supplementary insulation only
26.6 Terminals for type X attachment and for connection of N
cables of fixed wiring suitable for connection of
conductors with cross-sectional area according to
table 13; rated current (A); nominal cross-sectional
area (mm²).................................................................... :
If a specially prepared cord is used, terminals need N
only be suitable for that cord
26.7 Terminals for type X attachment, except in class III N
appliances not containing live parts, accessible after
removal of a cover or part of the enclosure
26.8 Terminals for the connection of fixed wiring, including N
the earthing terminal, located close to each other
26.9 Terminals of the pillar type constructed and located as N
specified
26.10 Terminals with screw clamping and screwless N
terminals not used for flat twin tinsel cords, unless
conductors ends fitted with means suitable for screw N
terminals
Pull test of 5 N to the connection N
26.11 For type Y and Z attachment, soldered, welded, N
crimped or similar connections may be used

For Class II appliances, the conductor so positioned or N


fixed that reliance is not placed on soldering, welding
or crimping alone
Report No.: AGC08009200601ES01
Page 50 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
Conductors connected by soldering are not N
considered to be positioned or fixed so that reliance is
not placed upon the soldering alone to maintain them
in position unless they are held in place near the
terminals independently of the solder.
If soldering, welding or crimping alone used, barriers N
provided so that clearances and creepage distances
between live parts and other metal parts are not
reduced below the values for supplementary insulation
if the conductor becomes free

27 PROVISION FOR EARTHING N


27.1 Accessible metal parts of Class 0I and I appliances Class III appliances N
permanently and reliably connected to an earthing
terminal or earthing contact of the appliance inlet
Earthing terminals and earthing contacts not N
connected to the neutral terminal
Class 0, II and III appliances have no provision for P
protective earthing
Safety extra-low voltage circuits not earthed, unless N
protective extra-low voltage circuits N
27.2 Clamping means of earthing terminals adequately N
secured against accidental loosening
Terminals for the connection of external equipotential N
bonding conductors allow connection of conductors of
2.5 to 6 mm², and
- do not provide earthing continuity between different N
parts of the appliance, and
- conductors cannot be loosened without the aid of a N
tool
27.3 For a detachable part having an earth connection and N
being plugged into another part of the appliance, the
earth connection is made before and separated after
current-carrying connections when removing the part
For appliances with supply cords, current-carrying N
conductors become taut before earthing conductor, if
the cord slips out of the cord anchorage
27.4 No risk of corrosion resulting from contact between N
parts of the earthing terminal and the copper of the
earthing conductor or other metal
Parts providing earthing continuity, other than parts of N
a metal frame or enclosure, have adequate resistance
to corrosion
Report No.: AGC08009200601ES01
Page 51 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
If of steel, these parts provided with an electroplated N
coating with a thickness at least 5 µm
Adequate protection against rusting of parts of coated N
or uncoated steel, only intended to provide or transmit
contact pressure
In the body of the earthing terminal is a part of a frame N
or enclosure of aluminium or aluminium alloys,
precautions taken to avoid risk of corrosion
27.5 Low resistance of connection between earthing N
terminal and earthed metal parts
This requirement does not apply to connections N
providing earthing continuity in the protective extra-low
voltage circuit, provided the clearances of basic
insulation are based on the rated voltage of the
appliance
Resistance not exceeding 0,1 Ω at the specified low- N
resistance test (Ω ) ....................................................... :
27.6 The printed conductors of printed circuit boards not N
used to provide earthing continuity in hand-held
appliances.
They may be used to provide earthing continuity in N
other appliances if at least two tracks are used with
independent soldering points and the appliance
complies with 27.5 for each circuit

28 SCREWS AND CONNECTIONS P


28.1 Fixings, electrical connections and connections P
providing earthing continuity withstand mechanical
stresses
Screws not of soft metal liable to creep, such as zinc P
or aluminium
Diameter of screws of insulating material min. 3 mm N
Screws of insulating material not used for any N
electrical connections or connections providing
earthing continuity
Screws used for electrical connections or connections P
providing earthing continuity screwed into metal
Screws not of insulating material if their replacement N
by a metal screw can impair supplementary or
reinforced insulation
Report No.: AGC08009200601ES01
Page 52 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
For type X attachment, screws to be removed for N
replacement of supply cord or for user maintenance,
not of insulating material if their replacement by a
metal screw impairs basic insulation
For screws and nuts; torque-test as specified in table (see appended table) P
14.................................................................................. :
28.2 Electrical connections and connections providing N
earthing continuity constructed so that contact
pressure is not transmitted through non-ceramic
insulating material liable to shrink or distort, unless
there is resiliency in the metallic parts to compensate N
for shrinkage or distortion of the insulating material
This requirement does not apply to electrical connections in circuits of appliances for N
which:
 30.2.2 is applicable and that carry a current N
not exceeding 0,5 A
 30.2.3 is applicable and that carry a current N
not exceeding 0,2 A
28.3 Space-threaded (sheet metal) screws only used for N
electrical connections if they clamp the parts together
Thread-cutting (self-tapping) screws and thread rolling N
screws only used for electrical connections if they
generate a full form standard machine screw thread
Thread-cutting (self-tapping) screws not used if they N
are likely to be operated by the user or installer
Thread-cutting, thread rolling and space threaded screws may be used in connections N
providing earthing continuity provided it is not necessary to disturb the connection:
- in normal use, N
- during user maintenance, N
- when replacing a supply cord having a type X N
attachment, or
- during installation N
At least two screws being used for each connection N
providing earthing continuity, unless
the screw forms a thread having a length of at least N
half the diameter of the screw
28.4 Screws and nuts that make mechanical connection N
secured against loosening if they also make electrical
connections or connections providing earthing
continuity
This requirement does not apply to screws in the N
earthing circuit if at least two screws are used, or
Report No.: AGC08009200601ES01
Page 53 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
if an alternative earthing circuit is provided N
Rivets for electrical connections or connections N
providing earthing continuity secured against
loosening if the connections are subjected to torsion

29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION N


Clearances, creepage distances and solid insulation Class III product, no N
withstand electrical stress requirement for clearances,
creepage distances and solid
insulation
For coatings used on printed circuits boards to protect N
the microenvironment (Type 1) or to provide basic
insulation (Type 2), Annex J applies ............................ :
The microenvironment is pollution degree 1 under type N
1 protection
For type 2 protection, the spacing between the N
conductors before the protection is applied is not less
than the values specified in Table 1 of IEC 60664-3
These values apply to functional, basic, N
supplementary and reinforced insulation ..................... :
29.1 Clearances not less than the values specified in table (see appended table) N
16, taking into account the rated impulse voltage for
the overvoltage categories of table 15, unless ............. :
for basic insulation and functional insulation they N
comply with the impulse voltage test of clause 14
However, if the distances are affected by wear, N
distortion, movement of the parts or during assembly,
the clearances for rated impulse voltages of 1500V
and above are increased by 0,5 mm and the impulse
voltage test is not applicable
Impulse voltage test is not applicable: N
- when the microenvironment is pollution degree 3, or N
- for basic insulation of class 0 and class 01 N
appliances, or
Appliances are in overvoltage category II N
A force of 2 N is applied to bare conductors, other N
than heating elements
A force of 30 N is applied to accessible surfaces N
29.1.1 Clearances of basic insulation withstand the (see appended table) N
overvoltages, taking into account the rated impulse
voltage
Report No.: AGC08009200601ES01
Page 54 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
The values of table 16 or the impulse voltage test of N
clause 14 are applicable .............................................. :
Clearance at the terminals of tubular sheathed heating N
elements may be reduced to 1,0 mm if the
microenvironment is pollution degree 1
Lacquered conductors of windings considered to be N
bare conductors
29.1.2 Clearances of supplementary insulation not less than (see appended table) N
those specified for basic insulation in table 16 ............. :
29.1.3 Clearances of reinforced insulation not less than those (see appended table) N
specified for basic insulation in table 16, using the next
higher step for rated impulse voltage ........................... :
For double insulation, with no intermediate conductive N
part between basic and supplementary insulation,
clearances are measured between live parts and the
accessible surface, and the insulation system is
treated as reinforced insulation
29.1.4 Clearances for functional insulation are the largest values determined from: N
- table 16 based on the rated impulse voltage ............. : (see appended table) N
- table F.7a in IEC 60664-1, frequency not exceeding N
30 kHz
- clause 4 of IEC 60664-4, frequency exceeding 30 N
kHz
If values of table 16 are largest, the impulse voltage N
test of clause 14 may be applied instead, unless
the microenvironment is pollution degree 3, or N
the distances can be affected by wear, distortion, N
movement of the parts or during assembly
However, clearances are not specified if the appliance N
complies with clause 19 with the functional insulation
short-circuited
Lacquered conductors of windings considered to be N
bare conductors
However, clearances at crossover points are not N
measured
Clearance between surfaces of PTC heating elements N
may be reduced to 1mm
29.1.5 Appliances having higher working voltages than rated voltage, clearances for basic N
insulation are the largest values determined from:
- table 16 based on the rated impulse voltage ......: N
Report No.: AGC08009200601ES01
Page 55 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
- table F.7a in IEC 60664-1, frequency not exceeding N
30 kHz
- clause 4 of IEC 60664-4, frequency exceeding 30 N
kHz
If clearances for basic insulation are selected from N
Table F.7a of IEC 60664-1 or Clause 4 of IEC 60664-
4, the clearances of supplementary insulation are not
less than those specified for basic insulation
If clearances for basic insulation are selected from N
Table F.7a of IEC 60664-1, the clearances of
reinforced insulation dimensioned as specified in
Table F.7a are to withstand 160% of the withstand
voltage required for basic insulation
If clearances for basic insulation are selected from N
Clause 4 of IEC 60664-4, the clearances of reinforced
insulation are twice the value required for basic
insulation
If the secondary winding of a step-down transformer is N
earthed, or if there is an earthed screen between the
primary and secondary windings, clearances of basic
insulation on the secondary side not less than those
specified in table 16, but using the next lower step for
rated impulse voltage
Circuits supplied with a voltage lower than rated N
voltage, clearances of functional insulation are based
on the working voltage used as the rated voltage in
table 15
29.2 Creepage distances not less than those appropriate (see appended table) N
for the working voltage, taking into account the
material group and the pollution degree ...................... :
Pollution degree 2 applies, unless N
- precautions taken to protect the insulation; pollution N
degree 1
- insulation subjected to conductive pollution; pollution N
degree 3
Electrode-type appliances, the microenvironment of the N
insulation supporting the electrodes is
pollution degree 3 (EN 60335-2-98)
A force of 2 N is applied to bare conductors, other N
than heating elements
A force of 30 N is applied to accessible surfaces N
Report No.: AGC08009200601ES01
Page 56 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
In a double insulation system, the working voltage for N
both the basic and supplementary insulation is taken
as the working voltage across the complete double
insulation system
The microenvironment is pollution degree 3 unless the N
insulation is enclosed or located so that it is unlikely to
be exposed to pollution during normal use of the
appliance.(EN 60335-2-80)
29.2.1 Creepage distances of basic insulation not less than (see appended table) N
specified in table 17...............................................:
However, if the working voltage is periodic and has a N
frequency exceeding 30 kHz, the creepage distances
are also determined from table 2 of IEC 60664-4,
these values being used if exceeding the values in
table 17 ......................................................................... :
Except for pollution degree 1, corresponding creepage N
distance not less than the minimum specified for the
clearance in table 16, if the clearance has been
checked according to the test of clause 14 .................. :
29.2.2 Creepage distances of supplementary insulation at (see appended table) N
least those specified for basic insulation in table 17, or
...................................................................................... :
Table 2 of IEC 60664-4, as applicable ......................... : N
29.2.3 Creepage distances of reinforced insulation at least (see appended table) N
double those specified for basic insulation in table 17,
or .................................................................................. :
Table 2 of IEC 60664-4, as applicable ......................... : N
29.2.4 Creepage distances of functional insulation not less (see appended table) N
than specified in table 18 ............................................. :
However, if the working voltage is periodic and has a N
frequency exceeding 30 kHz, the creepage distances
are also determined from table 2 of IEC 60664-4,
these values being used if exceeding the values in
table 18 ......................................................................... :
Creepage distances may be reduced if the appliance N
complies with clause 19 with the functional insulation
short-circuited
29.3 Supplementary and reinforced insulation have N
adequate thickness, or a sufficient number of layers,
to withstand the electrical stresses
Compliance checked: N
- by measurement, in accordance with 29.3.1, or N
Report No.: AGC08009200601ES01
Page 57 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
- by an electric strength test in accordance with 29.3.2, N
or
- by an assessment of the thermal quality of the N
material combined with an electric strength test, in
accordance with 29.3.3, and
for accessible parts of reinforced insulation consisting N
of a single layer, by measurement in accordance with
29.3.4, or
- as specified in subclause 6.3 of IEC 60664-4 for N
insulation that is subjected to any periodic voltage
having a frequency exceeding 30 kHz
29.3.1 Supplementary insulation have a thickness of at least N
1 mm
Reinforced insulation have a thickness of at least 2 N
mm
29.3.2 Each layer of material withstand the electric strength N
test of 16.3 for supplementary insulation
Supplementary insulation consist of at least 2 layers N
Reinforced insulation consist of at least 3 layers N
29.3.3 The insulation is subjected to the dry heat test Bb of N
IEC 60068-2-2, followed by
the electric strength test of 16.3 N
If the temperature rise during the tests of clause 19 N
does not exceed the value specified in table 3, the test
of IEC 60068-2-2 is not carried out
29.3.4 Thickness of accessible parts of reinforced insulation N
consisting of a single layer not less than specified in
table 19 ......................................................................... :
29.3.Z1 Appliance constructed so that if there is a possibility of N
damaging the insulation during installation, the
insulation withstands the scratch and penetration test
of 21.2

30 RESISTANCE TO HEAT AND FIRE P


30.1 External parts of non-metallic material, P
parts supporting live parts, and N
parts of thermoplastic material providing N
supplementary or reinforced insulation
sufficiently resistant to heat P
Ball-pressure test according to IEC 60695-10-2 P
Report No.: AGC08009200601ES01
Page 58 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
External parts tested at 40 C plus the maximum (see appended table) P
temperature rise determined during the test of clause
11, or at 75 C, whichever is the higher; temperature
(C) ........................................................................:
Parts supporting live parts tested at 40C plus the N
maximum temperature rise determined during the test
of clause 11, or at 125 C, whichever is the higher;
temperature (C)........................................................... :
Parts of thermoplastic material providing N
supplementary or reinforced insulation tested at 25 C
plus the maximum temperature rise determined during
clause 19, if higher; temperature (C) .......................... :
30.2 Parts of non-metallic material resistant to ignition and P
spread of fire
This requirement does not apply to: P
parts having a mass not exceeding 0,5 g, provided the P
cumulative effect is unlikely to propagate flames that
originate inside the appliance by propagating flames
from one part to another, or
decorative trims, knobs and other parts unlikely to be P
ignited or to propagate flames that originate inside the
appliance
Compliance checked by the test of 30.2.1, and in P
addition:
- for attended appliances, 30.2.2 applies N
- for unattended appliances, 30.2.3 applies P
For appliances for remote operation, 30.2.3 applies N
For base material of printed circuit boards, 30.2.4 P
applies
30.2.1 Parts of non-metallic material subjected to the glow- (see appended table) P
wire test of IEC 60695-2-11 at 550C
However, test not carried out if the material is N
classified as having a glow-wire flammability index
according to IEC 60695-2-12 of at least 550 C, or
the material is classified at least HB40 according to N
IEC 60695-11-10
Parts for which the glow-wire test cannot be carried N
out need to meet the requirements in ISO 9772 for
material classified HBF
30.2.2 Not applicable (EN 60335-2-80) N
30.2.2 Not applicable.(EN 60335-2-98) N
Report No.: AGC08009200601ES01
Page 59 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
30.2.3 Appliances operated while unattended, tested as N
specified in 30.2.3.1 and 30.2.3.2
The tests are not applicable to conditions as specified : Low-power appliances P
30.2.3.1 Parts of non-metallic material supporting connections N
carrying a current exceeding 0,2 A during normal
operation, and
parts of non-metallic material, other than small parts, N
within a distance of 3 mm,
subjected to the glow-wire test of IEC 60695-2-11 with (see appended table) N
a test severity of 850 °C
Glow-wire applied to an interposed shielding material, N
if relevant
The glow-wire test is not carried out on parts of N
material classified as having a glow-wire flammability
index according to IEC 60695-2-12 of at least 850 °C
30.2.3.2 Parts of non-metallic material supporting connections, N
and
parts of non-metallic material within a distance of N
3mm,
subjected to the glow-wire test of IEC 60695-2-11 with (see appended table) N
appropriate severity level:
- 750 C, for connections carrying a current exceeding N
0,2 A during normal operation
- 650 C, for other connections N
Glow-wire applied to an interposed shielding material, N
if relevant
However, the glow-wire test of 750 C or 650 C as appropriate, is not carried out on N
parts of material fulfilling both or either of the following classifications:
- a glow-wire ignition temperature according to IEC N
60695-2-13 of at least:
 775 C, for connections carrying a current N
exceeding 0,2 A during normal operation
 675 C, for other connections N
- a glow-wire flammability index according to IEC N
60695-2-12 of at least:
- 750 C, for connections carrying a current exceeding N
0,2 A during normal operation
- 650 C, for other connections N
The glow-wire test is also not carried out on small parts. These parts are to: N
Report No.: AGC08009200601ES01
Page 60 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
- comprise material having a glow-wire ignition N
temperature of at least 775 C or 675 C as
appropriate, or
- comprise material having a glow-wire flammability N
index of at least 750 C or 650 C as appropriate, or
- comply with the needle-flame test of Annex E, or N
- comprise material classified as V-0 or V-1 according N
to IEC 60695-11-10
The consequential needle-flame test of Annex E applied to non-metallic parts that N
encroach within the vertical cylinder placed above the centre of the connection zone and
on top of the non-metallic parts supporting current-carrying connections, and parts of
non-metallic material within a distance of 3 mm of such connections if these parts are
those:
- parts that withstood the glow-wire test of IEC 60695- N
2-11 of 750 C or 650 C as appropriate, but produce
a flame that persist longer than 2 s, or
- parts that comprised material having a glow-wire N
flammability index of at least 750 C or 650 C as
appropriate, or
- small parts, that comprised material having a glow- N
wire flammability index of at least 750 C or 650 C as
appropriate, or
- small parts for which the needle-flame test of Annex N
E was applied, or
- small parts for which a material classification of V-0 N
or V-1 was applied
However, the consequential needle-flame test is not carried out on non-metallic parts, N
including small parts, within the cylinder that are:
- parts having a glow-wire ignition temperature of at N
least 775 C or 675 C as appropriate, or
- parts comprising material classified as V-0 or V-1 N
according to IEC 60695-11-10, or
- parts shielded by a flame barrier that meets the N
needle-flame test of Annex E or that comprises
material classified as V-0 or V-1 according to IEC
60695-11-10
30.2.4 Base material of printed circuit boards subjected to the (see appended table) N
needle-flame test of Annex E
Test not applicable to conditions as specified .............. : Low-power appliances P

31 RESISTANCE TO RUSTING N
Report No.: AGC08009200601ES01
Page 61 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
Relevant ferrous parts adequately protected against N
rusting
Tests specified in part 2 when necessary N

32 RADIATION, TOXICITY AND SIMILAR HAZARDS P


Appliance does not emit harmful radiation or present a P
toxic or similar hazard due to their operation in normal
use
Compliance is checked by the limits or tests specified P
in part 2, if relevant
Compliance regarding electromagnetic fields is P
checked according to EN 62233

A ANNEX A (INFORMATIVE) N
ROUTINE TESTS
Description of routine tests to be carried out by the N
manufacturer

B ANNEX B (NORMATIVE) N
APPLIANCES POWERED BY RECHARGEABLE BATTERIES
The following modifications to this standard are N
applicable for appliances powered by batteries that
are recharged in the appliance
This annex does not apply to battery chargers N
3.1.9 Appliance operated under the following conditions: N
- the appliance, supplied by its fully charged battery, N
operated as specified in relevant part 2
- the battery is charged, the battery being initially N
discharged to such an extent that the appliance
cannot operate
-if possible, the appliance is supplied from the supply N
mains through its battery charger, the battery being
initially discharged to such an extent that the
appliance cannot operate. The appliance is operated
as specified in relevant part 2
- if the appliance incorporates inductive coupling N
between two parts that are detachable from each
other, the appliance is supplied from the supply mains
with the detachable part removed
3.6.2 Part to be removed in order to discard the battery is N
not considered to be detachable
Report No.: AGC08009200601ES01
Page 62 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
5.B.101 Appliances supplied from the supply mains tested as N
specified for motor-operated appliances
7.1 Battery compartment for batteries intended to be N
replaced by the user, marked with battery voltage (V)
and polarity of the terminals ......................................... :
The positive terminal indicated by symbol IEC 60417- N
5005 and the negative terminal by symbol IEC 60417-
5006
7.6 Additional symbols N
7.12 The instructions give information regarding charging N
The instructions for appliances incorporating batteries N
intended to be replaced by the user includes required
information
Details about how to remove batteries containing N
materials hazardous to the environment given
7.15 Markings placed on the part of the appliance N
connected to the supply mains
8.2 Appliances having batteries that according to the N
instruction may be replaced by the user need only
have basic insulation between live parts and the inner
surface of the battery compartment
If the appliance can be operated without batteries, N
double or reinforced insulation required
11.7 The battery is charged for the period stated in the N
instructions or 24 h ....................................................... :
19.1 Appliances subjected to tests of 19.B.101, 19.B.102 N
and 19.B.103
19.10 Not applicable N
19.B.101 Appliances supplied at rated voltage for 168 h, the N
battery being continually charged
19.B.102 For appliances having batteries that can be removed N
without the aid of a tool, short-circuit of the terminals
of the battery, the battery being fully charged,
19.B.103 Appliances having batteries replaceable by the user N
supplied at rated voltage under normal operation with
the battery removed or in any position allowed by the
construction
21.B.101 Appliances having pins for insertion into socket-outlets N
have adequate mechanical strength
Part of the appliance incorporating the pins subjected to the free fall test, procedure 2, of N
IEC 60068-2-31, the number of falls being:
Report No.: AGC08009200601ES01
Page 63 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
- 100, if the mass of the part does not exceed 250 g N
(g) ................................................................................. :
- 50, if the mass of the part exceeds 250 g .................. : N
After the test, the requirements of 8.1, 15.1.1, 16.3 N
and clause 29 are met
22.3 Appliances having pins for insertion into socket-outlets N
tested as fully assembled as possible
25.13 An additional lining or bushing not required for N
interconnection cords in class III appliances or class III
constructions operating at safety extra-low voltage not
containing live parts
30.2 For parts of the appliance connected to the supply N
mains during the charging period, 30.2.3 applies
For other parts, 30.2.2 applies N

C ANNEX C (NORMATIVE) N
AGEING TEST ON MOTORS
Tests, as described, carried out when doubt with N
regard to the temperature classification of the
insulation of a motor winding
Test conditions as specified N

D ANNEX D (NORMATIVE) N
THERMAL MOTOR PROTECTORS
Applicable to appliances having motors that N
incorporate thermal motor protectors necessary for
compliance with the standard
Test conditions as specified N

E ANNEX E (NORMATIVE) N
NEEDLE-FLAME TEST
Needle-flame test carried out in accordance with IEC 60695-11-5, with the following N
modifications:
7 Severities N
The duration of application of the test flame is N
30 s ± 1 s
9 Test procedure N
9.1 The specimen so arranged that the flame can be N
applied to a vertical or horizontal edge as shown in the
examples of Figure 1
Report No.: AGC08009200601ES01
Page 64 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
9.2 The first paragraph does not apply N
If possible, the flame is applied at least 10 mm from a N
corner
9.3 The test is carried out on one specimen N
If the specimen does not withstand the test, the test N
may be repeated on two additional specimens, both
withstanding the test
11 Evaluation of test results N
The duration of burning not exceeding 30 s N
However, for printed circuit boards, the duration of N
burning not exceeding 15 s

F ANNEX F (NORMATIVE) N
CAPACITORS
Capacitors likely to be permanently subjected to the supply voltage, and used for radio N
interference suppression or voltage dividing, comply with the following clauses of IEC
60384-14, with the following modifications:
1.5 Terms and definitions N
1.5.3 Class X capacitors tested according to subclass X2 N
1.5.4 This subclause is applicable N
1.6 Marking N
Items a) and b) are applicable N
3.4 Approval testing N
3.4.3.2 Table 3 is applicable as described N
4.1 Visual examination and check of dimensions N
This subclause is applicable N
4.2 Electrical tests N
4.2.1 This subclause is applicable N
4.2.5 This subclause is applicable N
4.2.5.2 Only table 11 is applicable N
Values for test A apply N
However, for capacitors in heating appliances the N
values for test B or C apply
4.12 Damp heat, steady state N
This subclause is applicable N
Only insulation resistance and voltage proof are N
checked
Report No.: AGC08009200601ES01
Page 65 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
4.13 Impulse voltage N
This subclause is applicable N
4.14 Endurance N
Subclauses 4.14.1, 4.14.3, 4.14.4 and 4.14.7 are N
applicable
4.14.7 Only insulation resistance and voltage proof are N
checked
No visible damage N
4.17 Passive flammability test N
This subclause is applicable N
4.18 Active flammability test N
This subclause is applicable N

G ANNEX G (NORMATIVE) N
SAFETY ISOLATING TRANSFORMERS
The following modifications to this standard are applicable for safety isolating N
transformers:
7 Marking and instructions N
7.1 Transformers for specific use marked with: N
-name, trademark or identification mark of the N
manufacturer or responsible vendor ............................ :
-model or type reference .............................................. : N
17 Overload protection of transformers and associated circuits N
Fail-safe transformers comply with subclause 15.5 of N
IEC 61558-1
22 Construction N
Subclauses 19.1 and 19.1.2 of IEC 61558-2-6 are N
applicable
29 Clearances, creepage distances and solid insulation N
29.1, 29.2, The distances specified in items 2a, 2c and 3 in table N
29.3 13 of IEC 61558-1 apply
For insulated winding wires complying with subclause N
19.12.3 of IEC 61558-1 there are no requirements for
clearances or creepage distances
For windings providing reinforced insulation, the N
distance specified in item 2c of table 13 of IEC 61558-
1 is not assessed
Report No.: AGC08009200601ES01
Page 66 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
For safety isolating transformers subjected to periodic N
voltages with a frequency exceeding 30 kHz, the
clearances, creepage distances and solid insulation
values specified in IEC 60664-4 are applicable, if
greater than the values specified in items 2a, 2c and 3
in table 13 of IEC 61558-1

H ANNEX H (NORMATIVE) N
SWITCHES
Switches comply with the following clauses of IEC 61058-1, as modified below: N
The tests of IEC 61058-1 carried out under the N
conditions occurring in the appliance
Before being tested, switches are operated 20 times N
without load
8 Marking and documentation N
Switches are not required to be marked N
However, a switch that can be tested separately from N
the appliance marked with the manufacturer’s name or
trade mark and the type reference
13 Mechanism N
The tests may be carried out on a separate sample N
15 Insulation resistance and dielectric strength N
15.1 Not applicable N
15.2 Not applicable N
15.3 Applicable for full disconnection and micro- N
disconnection
17 Endurance N
Compliance is checked on three separate appliances N
or switches
For 17.2.4.4, the number of cycles declared according N
to 7.1.4 is 10 000, unless
otherwise specified in 24.1.3 of the relevant part 2 of N
IEC 60335 .................................................................... :
Switches for operation under no load and which can N
be operated only by a tool, and
switches operated by hand that are interlocked so that N
they cannot be operated under load,
are not subjected to the tests N
Report No.: AGC08009200601ES01
Page 67 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
However, switches without this interlock are subjected N
to the test of 17.2.4.4 for 100 cycles of operation
Subclauses 17.2.2 and 17.2.5.2 not applicable N
The ambient temperature during the test is that N
occurring in the appliance during the test of Clause 11
in IEC 60335-1
The temperature rise of the terminals not more than N
30 K above the temperature rise measured in clause
11 of IEC 60335-1 (K) .................................................. :
20 Clearances, creepage distances, solid insulation and coatings of rigid printed board N
assemblies
Clause 20 is applicable to clearances across full N
disconnection and micro-disconnection
It is also applicable to creepage distances for N
functional insulation, across full disconnection and
micro-disconnection, as stated in Table 24

I ANNEX I (NORMATIVE) N
MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE RATED
VOLTAGE OF THE APPLIANCE
The following modifications to this standard are applicable for motors having basic N
insulation that is inadequate for the rated voltage of the appliance:
8 Protection against access to live parts N
8.1 Metal parts of the motor are considered to be bare live N
parts
11 Heating N
11.3 The temperature rise of the body of the motor is N
determined instead of the temperature rise of the
windings
11.8 The temperature rise of the body of the motor, where N
in contact with insulating material, not exceeding
values in table 3 for the relevant insulating material
16 Leakage current and electric strength N
16.3 Insulation between live parts of the motor and its other N
metal parts is not subjected to the test
19 Abnormal operation N
19.1 The tests of 19.7 to 19.9 are not carried out N
19.I.101 The appliance is supplied at rated voltage and operated under normal operation with N
each of the fault conditions specified:
Report No.: AGC08009200601ES01
Page 68 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
- short circuit of the terminals of the motor, including N
any capacitor incorporated in the motor circuit
- short circuit of each diode of the rectifier N
- open circuit of the supply to the motor N
- open circuit of any parallel resistor, the motor being N
in operation
Only one fault simulated at a time, the tests carried out N
consecutively
The duration of the test is as specified in 19.7 N
22 Construction N
22.I.101 For class I appliances incorporating a motor supplied N
by a rectifier circuit, the d.c. circuit being insulated
from accessible parts of the appliance by double or
reinforced insulation
Compliance checked by the tests specified for double N
and reinforced insulation

J ANNEX J (NORMATIVE) N
COATED PRINTED CIRCUIT BOARDS
Testing of protective coatings of printed circuit boards carried out in accordance with N
IEC 60664-3 with the following modifications:
5.7 Conditioning of the test specimens N
When production samples are used, three samples of N
the printed circuit board are tested
5.7.1 Cold N
The test is carried out at -25 C N
5.7.3 Rapid change of temperature N
Severity 1 is specified N
5.9 Additional tests N
This subclause is not applicable N

K ANNEX K (NORMATIVE) N
OVERVOLTAGE CATEGORIES
The information on overvoltage categories is extracted N
from IEC 60664-1
Overvoltage category is a numeral defining a transient N
overvoltage condition
Report No.: AGC08009200601ES01
Page 69 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
Equipment of overvoltage category IV is for use at the N
origin of the installation
Equipment of overvoltage category III is equipment in N
fixed installations and for cases where the reliability
and the availability of the equipment is subject to
special requirements
Equipment of overvoltage category II is energy N
consuming equipment to be supplied from the fixed
installation
If such equipment is subjected to special requirements N
with regard to reliability and availability, overvoltage
category III applies
Equipment of overvoltage category I is equipment for N
connection to circuits in which measures are taken to
limit transient overvoltages to an appropriate low level

L ANNEX L (INFORMATIVE) N
GUIDANCE FOR THE MEASUREMENT OF CLEARANCES AND CREEPAGE
DISTANCES
Information for the determination of clearances and N
creepage distances

M ANNEX M (NORMATIVE) N
POLLUTION DEGREE
The information on pollution degrees is extracted from N
IEC 60664-1
Pollution N
The microenvironment determines the effect of N
pollution on the insulation, taking into account the
macroenvironment
Means may be provided to reduce pollution at the N
insulation by effective enclosures or similar
Minimum clearances specified where pollution may be N
present in the microenvironment
Degrees of pollution in the microenvironment N
For evaluating creepage distances, the following degrees of pollution in the N
microenvironment are established:
- pollution degree 1: no pollution or only dry, non- N
conductive pollution occurs. The pollution has no
influence
Report No.: AGC08009200601ES01
Page 70 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
- pollution degree 2: only non-conductive pollution N
occurs, except that occasionally a temporary
conductivity caused by condensation is to be expected
- pollution degree 3: conductive pollution occurs or dry N
non-conductive pollution occurs that becomes
conductive due to condensation that is to be expected
- pollution degree 4: the pollution generates persistent N
conductivity caused by conductive dust or by rain or
snow

N ANNEX N (NORMATIVE) N
PROOF TRACKING TEST
The proof tracking test is carried out in accordance with IEC 60112 with the following N
modifications:
7 Test apparatus N
7.3 Test solutions N
Test solution A is used N
10 Determination of proof tracking index (PTI) N
10.1 Procedure N
The proof voltage is 100V, 175V, 400V or 600V...: N
The test is carried out on five specimens N
In case of doubt, additional test with proof voltage N
reduced by 25V, the number of drops increased to 100
10.2 Report N
The report states if the PTI value was based on a test N
using 100 drops with a test voltage of (PTI-25) V

O ANNEX O (INFORMATIVE) P
SELECTION AND SEQUENCE OF THE TESTS OF CLAUSE 30
Description of tests for determination of resistance to P
heat and fire

P ANNEX P (INFORMATIVE) N
GUIDANCE FOR THE APPLICATION OF THIS STANDARD TO APPLIANCES USED
IN WARM DAMP EQUABLE CLIMATES
Modifications applicable for class 0 and 01 appliances having a rated voltage exceeding N
150V, intended to be used in countries having a warm damp equable climate and that
are marked WDaE
Report No.: AGC08009200601ES01
Page 71 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
Modifications may also be applied to class 1 appliances having a rated voltage N
exceeding 150V, intended to be used in countries having a warm damp equable climate
and that are marked WdaE, if liable to be connected to a supply mains that excludes the
protective earthing conductor
5.7 The ambient temperature for the tests of clauses 11 N
and 13 is 40 +3/0 C
7.1 The appliance marked with the letters WDaE N
7.12 The instructions state that the appliance is to be N
supplied through a residual current device (RCD)
having a rated residual operating current not
exceeding 30 mA
The instructions state that the appliance is considered N
to be suitable for use in countries having a warm
damp equable climate, but may also be used in other
countries
11.8 The values of Table 3 are reduced by 15 K N
13.2 The leakage current for class I appliances not N
exceeding 0,5 mA
15.3 The value of t is 37 C N
16.2 The leakage current for class I appliances not N
exceeding 0,5 mA (mA):
19.13 The leakage current test of 16.2 is applied in addition N
to the electric strength test of 16.3

Q ANNEX Q (INFORMATIVE) N
SEQUENCE OF TESTS FOR THE EVALUATION OF ELECTRONIC CIRCUITS
Description of tests for appliances incorporating electronic circuits N

R ANNEX R (NORMATIVE) N
SOFTWARE EVALUATION
Programmable electronic circuits requiring software N
incorporating measures to control the fault/error
conditions specified in table R.1 or R.2 validated in
accordance with the requirements of this annex
R.1 Programmable electronic circuits using software N
Programmable electronic circuits requiring software N
incorporating measures to control the fault/error
conditions specified in table R.1 or R.2 constructed so
that the software does not impair compliance with the
requirements of this standard
R.2 Requirements for the architecture N
Report No.: AGC08009200601ES01
Page 72 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
Programmable electronic circuits requiring software N
incorporating measures to control the fault/error
conditions specified in table R.1 or R.2 use measures
to control and avoid software-related faults/errors in
safety-related data and safety-related segments of the
software
R.2.1.1 Programmable electronic circuits requiring software incorporating measures to control N
the fault/error conditions specified in table R.2 have one of the following structures:
- single channel with periodic self-test and monitoring N
- dual channel (homogenous) with comparison N
- dual channel (diverse) with comparison N
Programmable electronic circuits requiring software incorporating measures to control N
the fault/error conditions specified in table R.1 have one of the following structures:
- single channel with functional test N
- single channel with periodic self-test N
- dual channel without comparison N
R.2.2 Measures to control faults/errors N
R.2.2.1 When redundant memory with comparison is provided N
on two areas of the same component, the data in one
area is stored in a different format from that in the
other area
R.2.2.2 Programmable electronic circuits with functions N
requiring software incorporating measures to control
the fault/error conditions specified in table R.2 and that
use dual channel structures with comparison, have
additional fault/error detection means for any
fault/errors not detected by the comparison
R.2.2.3 For programmable electronic circuits with functions N
requiring software incorporating measures to control
the fault/error conditions specified in table R.1 or R.2,
means are provided for the recognition and control of
errors in transmissions to external safety-related data
paths
R.2.2.4 For programmable electronic circuits with functions N
requiring software incorporating measures to control
the fault/error conditions specified in table R.1 or R.2,
the programmable electronic circuits incorporate
measures to address the fault/errors in safety-related
segments and data indicated in table R.1 and R.2 as
appropriate
Report No.: AGC08009200601ES01
Page 73 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
R.2.2.5 For programmable electronic circuits with functions N
requiring software incorporating measures to control
the fault/error conditions specified in table R.1 or R.2,
detection of a fault/error occur before compliance with
clause 19 is impaired
R.2.2.6 The software is referenced to relevant parts of the N
operating sequence and the associated hardware
functions
R.2.2.7 Labels used for memory locations are unique N
R.2.2.8 The software is protected from user alteration of N
safety-related segments and data
R.2.2.9 Software and safety-related hardware under its control N
is initialized and terminates before compliance with
clause 19 is impaired
R.3 Measures to avoid errors N
R.3.1 General N
For programmable electronic circuits with functions requiring software incorporating N
measures to control the fault/error conditions specified in table R.1 or R.2, the following
measures to avoid systematic fault in the software are applied
Software that incorporates measures used to control N
the fault/error conditions specified in table R.2 is
inherently acceptable for software required to control
the fault/error conditions specified in table R.1
R.3.2 Specification N
R.3.2.1 Software safety requirements: Software Id: N
The specification of the software safety requirements N
includes the descriptions listed
R.3.2.2 Software architecture N
R.3.2.2.1 The specification of the software architecture includes Document ref. No: N
the aspects listed
- techniques and measures to control software
faults/errors (refer to R.2.2);
- interactions between hardware and software;
- partitioning into modules and their allocation to the
specified safety functions;
- hierarchy and call structure of the modules (control
flow);
- interrupt handling;
- data flow and restrictions on data access;
- architecture and storage of data;
- time-based dependencies of sequences and data
Report No.: AGC08009200601ES01
Page 74 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
R.3.2.2.2 The architecture specification is validated against the N
specification of the software safety requirements by
static analysis
R.3.2.3 Module design and coding N
R.3.2.3.1 Based on the architecture design, software is suitably N
refined into modules
Software module design and coding is implemented in N
a way that is traceable to the software architecture
and requirements
R.3.2.3.2 Software code is structured N
R.3.2.3.3 Coded software is validated against the module N
specification by static analysis
The module specification is validated against the N
architecture specification by static analysis
R.3.3.3 Software validation N
The software is validated with reference to the N
requirements of the software safety requirements
specification
Compliance is checked by simulation of: N
- input signals present during normal operation N
- anticipated occurrences N
- undesired conditions requiring system action N
e
TABLE R.1 – GENERAL FAULT/ERROR CONDITIONSN
Component a Fault/error Acceptable measures b, c Definitions Document Document Ver-dict
reference reference for
for applied applied test
measure
1 CPU
1.1
Registers Stuck at Functional test, or H.2.16.5
periodic self-test using either: H.2.16.6
- static memory test, or H.2.19.6
- word protection with H.2.19.8.2
single bit redundancy
1.2 VOID
Report No.: AGC08009200601ES01
Page 75 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
1.3 Stuck at Functional test, or H.2.16.5
Programme Periodic self-test, or H.2.16.6
counter
Independent time-slot H.2.18.10.4
monitoring, or
Logical monitoring of the H.2.18.10.2
programme sequence
2 No Functional test, or H.2.16.5
Interrupt interrupt or time-slot monitoring H.2.18.10.4
handling and too
execution frequent
interrupt
3 Wrong Frequency monitoring, or H.2.18.10.1
Clock frequency time slot monitoring H.2.18.10.4
(for quartz
synchroniz
ed clock:
harmonics/
sub-
harmonics
only)
4. Memory
4.1 All single Periodic modified checksum, or H.2.19.3.1
Invariable bit faults multiple checksum, or H.2.19.3.2
memory
word protection with single bit H.2.19.8.2
redundancy
4.2 DC fault Periodic static memory test, or H.2.19.6
Variable word protection with single bit H.2.19.8.2
memory redundancy

4.3 Stuck at Word protection with single bit H.2.19.8.2


Addressing redundancy including the
(relevant to address
variable and
invariable
memory)
5 Stuck at Word protection with single bit H.2.19.8.2
Internal data redundancy
path
5.1 VOID
5.2 Wrong Word protection with single bit H.2.19.8.2
Addressing address redundancy including the
address
Report No.: AGC08009200601ES01
Page 76 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
6 Hamming Word protection with multi-bit H.2.19.8.1
External distance 3 redundancy, or
communicati CRC – single work, or H.2.19.4.1
on
Transfer redundancy, or H.2.18.2.2
Protocol test H.2.18.14
6.1 VOID
6.2 VOID
6.3 Wrong Time-slot monitoring, or H.2.18.10.4
Timing point in scheduled transmission H.2.18.18
time
Time-slot and logical H.2.18.10.3
monitoring, or
comparison of redundant
communication channels by
either:
- reciprocal comparison H.2.18.15
- independent hardware H.2.18.3
comparator
Wrong Logical monitoring, or H.2.18.10.2
sequence time-slot monitoring, or H.2.18.10.4
Scheduled transmission H.2.18.18
7 Fault Plausibility check H.2.18.13
Input/output conditions
periphery specified in
19.11.2
7.1 VOID
7.2
Analog I/O
7.2.1 Fault Plausibility check H.2.18.13
A/D and D/A- conditions
converter specified in
19.11.2
7.2.2 Wrong Plausibility check H.2.18.13
Analog addressing
multiplexer
8 VOID
9 Any output Periodic self-test H.2.16.6
Custom outside the
chips d e.g. static and
ASIC, GAL, dynamic
gate array functional
specificatio
n
Report No.: AGC08009200601ES01
Page 77 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
NOTE A Stuck-at fault model denotes a fault model representing an open circuit or a non-varying signal level. A DC
fault model denotes a stuck-at fault model incorporating short circuit between signal lines.
a)
For fault/error assessment, some components are divided into their sub-functions.
b)
For each sub-function in the table, the Table R.2 measure will cover the software fault/error.
c)
Where more than one measure is given for a sub-function, these are alternatives.
d)
To be divided as necessary by the manufacturer into sub-functions.
e)
Table R.1 is applied according to the requirements of R.1 to R.2.2.9 inclusive.

ZA ANNEX ZA (NORMATIVE) P
SPECIAL NATIONAL CONDITIONS
Norway N
19.5 The test is also applicable to appliances intended to N
be permanently connected to fixed wiring
Norway N
22.2 The second paragraph of this subclause, dealing with N
single-phase, permanently connected class I
appliances having heating elements, is not applicable
due to the supply system
All CENELEC countries P
25.6 and Information concerning National plug and P
25.25 socketoutlets is available from the CENELEC website.
Normative national requirements concerning plug and
socket-outlets are shown in the relevant National
standard
Ireland and United Kingdom N
25.8 In the table, the lines for 10 A and 16 A are replaced N
by:
> 10 and ≤ 13 1,25 N
> 13 and ≤ 16 1,5 N

ZB ANNEX ZB (INFORMATIVE) N
A-DEVIATIONS
Ireland N
25.6 These regulations apply to all plugs for domestic use N
at a voltage of not less than 200 V and in general
allow only plugs complying with I.S. 401:1997, or
equivalent, to be fitted to domestic appliances
United Kingdom N
Report No.: AGC08009200601ES01
Page 78 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict
25.6 These regulations apply to all plugs for domestic use N
at a voltage of not less than 200 V and in general
allow only plugs to BS 1363 to be fitted to domestic
appliances. It also allows plugs to BS 4573 and EN
50075 to be fitted to shavers and toothbrushes

ZC ANNEX ZC (NORMATIVE) P
NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR
CORRESPONDING EUROPEAN PUBLICATIONS
A list of referenced documents in this standard P

ZD ANNEX ZD (INFORMATIVE) P
IEC and CENELEC CODE DESIGNATIONS FOR FLEXIBLE CORDS
A table with IEC and CENELEC code designations for P
flexible cords

ZE ANNEX ZE (INFORMATIVE) N
SPECIFIC ADDITIONAL REQUIREMENTS FOR APPLIANCES AND MACHINES
INTENDED FOR COMMERCIAL USE
Requirements not applicable to the evaluated product N

ZF ANNEX ZF (INFORMATIVE) P
CRITERIA APPLIED FOR THE ALLOCATION OF PRODUCTS COVERED BY
STANDARDS IN THE EN 60335 SERIES UNDER LVD OR MD
List of standards under CENELEC/TC61 with the P
allocation under the LVD (Low Voltage Directive) or
the MD (Machinery Directive) ................................:

ZG ANNEX ZG (NORMATIVE) N
UV APPLIANCES
Requirements not applicable to the evaluated product N

ZZ ANNEX ZZ (INFORMATIVE) P
COVERAGE OF ESSENTIAL REQUIREMENTS OF EC DIRECTIVES
Description of the relation between this European P
standard and the LVD (Low Voltage Directive,
2006/95/EC) and the MD (Machinery Directive,
2006/42/EC)
Report No.: AGC08009200601ES01
Page 79 of 94

EN 60335-2-80, EN 60335-2-98
Clause Requirement - Test Result Verdict

ZZA ANNEX ZZA (INFORMATIVE) P


REALATIONSHIP BETWEEN THIS EUROPEAN STANDARD AND THE SAFETY
OBJECTIVES OF DIRECTIVE 2014/35/EU [2014 OJ L96] AIMED TO BE COVERED
Description relating to harmonized standards in the 2014/35/EU P
field of the Low Voltage Directive, M/511, to provide
one voluntary means of conforming to safety
objectives of Directive 2014/35/EU of the European
Parliament and of the Council of 26 February 2014 on
the harmonization of the laws of the Member States
relating to the making available on the market of
electrical equipment designed for use within certain
voltage limits [2014 OJ L96]
A table with correspondence between this European P
standard and Annex I of Directive 2014/35/EU [2014
OJ L96]

ZZB ANNEX ZZB (INFORMATIVE) N


REALATIONSHIP BETWEEN THIS EUROPEAN STANDARD AND THE ESSENTIAL
REQUIREMENTS OF DIRECTIVE 2006/42/EC AIMED TO BE COVERED
Description relating to Mandate for standardization in N
the field of machinery “M/396” to provide one voluntary
means of conforming to essential requirements of EU
Directive 2006/42/EC
A table with correspondence between this European N
standard and Annex I of Directive 2006/42/E [OJ No L
157]
Report No.: AGC08009200601ES01
Page 80 of 94

EN 62233
Clause Requirement - Test Result Verdict
Requirement & Testing
Measuring method 5.5.2 (Time domain evaluation) P

Measuring method 5.5.3 (Line spectrum evaluation) N

Measuring method 5.5.4 (simplified domain evaluation) N


Measuring distance (cm) (See test report ) --
Sensor location: (See test report ) --
Operation conditions: (See test report ) --
Magnetic flux density (maximum) (uT) : 2.0 --
If the measured value exceeds the reference level, the value is weighted with coupling factor: N
Weighted result, W= N
Coupling factor: N
Limit 100% Measured max <10% --
Test result P

5 Test report P

Type of applicance: MO9406 --

Input voltage: 5VDC(Test with DC Power) --


Measuring Weighted
Sensor locations Operating conditions Coupling Factor(ac)
distance(cm) result(W)

30 Around Normal operation -- <1

Note: The value W shall not exceed 1.


Report No.: AGC08009200601ES01
Page 81 of 94

10.1 TABLE: Power input deviation P


Input deviation of/at: P rated (W) P measured (W) ΔP Required ΔP Remark

-- -- -- -- -- --
Supplementary information:

10.2 TABLE: Current deviation P


Current deviation of/at: I rated (A) I measured (A) ΔI Required ΔI Remark

Normal operation,
5VDC 0.5 0.5 0% +20%
Test with DC Power
Supplementary information:

11.8 TABLE: Temperature rise measurements P


Ambient (C) ................................................. : t1:22.4, t2:22.7 
test voltage (V) .............................................. : 1.06×5VDC=5.3VDC, Test with DC Power 
temperature rise dT of part/at: dT (K) required dT (K)

PCB near U1 29.0 T130-25=105


L1 51.3 80
C2 34.2 T105-25=80
Plastic enclosure inside near L1 35.8 Ref.
Plastic enclosure outside near L1 13.9 60
Internal wire 31.4 T80-25=55
Atomizer 33.9 Ref.
Plastic enclosure inside near atomizer 17.2 Ref.
Plastic enclosure outside near atomizer 10.7 60
Touch switch 6.4 60
Bottom shell 1.8 60
Motor surface 20.1 65
Plastic housing near Motor 9.5 60
Test floor bottom 1.7 65
Winding temperature rise measurements: N
Insulation class ............................................. : -- 
Temperature rise dT of winding R1 (Ω) R2 (Ω) dT (K) Required dT (K) Insulation class
-- -- -- -- -- --
Supplementary information:
Report No.: AGC08009200601ES01
Page 82 of 94

13.2 TABLE: Leakage current measurements at operating temperature N


heating appliances: at 1,15 times maximum rated input -- 
(W) ............................................................................. :
motor-operated and combined appliances: at -- 
1,06 times rated voltage (V) ...................................... :
leakage current I between: I (mA) required I (mA)
-- -- --
Supplementary information:

13.3 TABLE: Electric strength measurements at operating temperature P


test voltage applied between: test voltage (V) breakdown(Yes/No)
Input and plastic enclosure(metal foil) 500 No
Supplementary information:

14 TABLE: Transient overvoltages N

Clearance between: Cl (mm) Required Cl (mm) Rated impulse Impulse test Flashover
voltage (V) voltage (V) (Yes/No)
-- -- -- -- -- --
Supplementary information:

16.2 TABLE: Leakage current measurements N


at 1,06 times rated voltage (V) ........................... : -- 
leakage current I between: I (mA) required I (mA)

-- -- --
Supplementary information:

16.3 TABLE: Electric strength measurements P


test voltage applied between: test voltage (V) breakdown(Yes/No)
Input and plastic enclosure(metal foil) 500 No
Supplementary information:

17.1 TABLE: Overload protection, temperature rise measurements N


at 1,06 or 0,94 times rated voltage (V) : -- --
temperature rise dT of part/at: dT (K) required dT (K)
-- -- --
Report No.: AGC08009200601ES01
Page 83 of 94

Supplementary information:

19.13 TABLE: Abnormal operation, temperature rises P


dT(K)
Thermocouple locations Max.dT (K)
19.7 -- -- --
T150-
Motor surface 42.4 -- -- --
25=125
Ambient 24.1C /23.7C -- -- -- --
Supplementary information: 19.7: Locked the DC fan, no any hazards.

24.1 TABLE: Components P


object/part No. Manufacturer/ trademark Type/model Technical data Standard Mark(s) of
conformity
UL 746 or UL
PCB Various Various V-0,130℃ UL
94
Internal wire Various Various 26AWG 300V 80℃ UL 758 UL
Plastic enclosure CHI MEI CORPORATION PA-765A(+) 94V-0, 80C UL 94 UL E56070
Test with
Motor SANLY SF4010SL DC5V 0.3A EN 60335-1
appliance
Ultrasonic HUNAN JIAYEDA Test with
JYD 1.7MHz EN 60335-1
transducer ELECTRONOC CO.,LTD appliance
Supplementary information:

28.1 TABLE: Threaded part torque test P


Threaded part identification Diameter of thread (mm) Column number Applied torque ( Nm )
(I, II, or III)
Fixed enclosure 2.5 II 0.4
Supplementary information:

29.1 TABLE: Clearances N


Overvoltage category ......................................: 
Type of insulation: 
Rated impulse Verdict /
Min. cl (mm) Basic Functional Supplementary Reinforced
voltage (V): Remark
330 0,5 -- -- -- -- N
500 0,5 -- -- -- -- N
800 0,5 -- -- -- -- N
1 500 0,5 -- -- -- -- N
Report No.: AGC08009200601ES01
Page 84 of 94

2 500 1,5 -- -- -- -- N
4 000 3,0 -- -- -- -- N
6 000 5,5 -- -- -- -- N
8 000 8,0 -- -- -- -- N
10 000 11,0 -- -- -- -- N
Supplementary information:
*) For tracks on printed circuit boards if pollution degree 1 and 2
**) For pollution degree 3
***) If the construction is affected by wear, distortion, movement of the parts or during assembly

29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation N


Working voltage (V) Creepage distance (mm) Pollution degree --
1 2 3 Type of insulation --
Material group Material group -- --
) ) )
I II IIIa/IIIb I II IIIa/IIIb B* S* R* Verdict
50 0,2 0,6 0,9 1,2 1,5 1,7 1,9    N
50 0,2 0,6 0,9 1,2 1,5 1,7 1,9    N
50 0,4 1,2 1,8 2,4 3,0 3,4 3,8    N
50 and 125 0,3 0,8 1,1 1,5 1,9 2,1 2,4    N
50 and 125 0,3 0,8 1,1 1,5 1,9 2,1 2,4    N
50 and 125 0,6 1,6 2,2 3,0 3,8 4,2 4,8    N
125 and 250 0,6 1,3 1,8 2.5 3,2 3,6 4,0    N
125 and 250 0,6 1,3 1,8 2.5 3,2 3,6 4,0    N
125 and 250 1,2 2,6 3,6 5,0 6,4 7,2 8,0    N
250 and 400 1,0 2,0 2,8 4,0 5,0 5,6 6,3    N
250 and 400 1,0 2,0 2,8 4,0 5,0 5,6 6,3    N
250 and 400 2,0 4,0 5,6 8,0 10,0 11,2 12,6    N
400 and 500 1,3 2,5 3,6 5,0 6,3 7,1 8,0    N
400 and 500 1,3 2,5 3,6 5,0 6,3 7,1 8,0    N
400 and 500 2,6 5,0 7,2 10,0 12,6 14,2 16,0    N
500 and 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0    N
500 and 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0    N
500 and 800 3,6 6,4 9,0 12,6 16,0 18,0 20,0    N
800 and 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5    N
800 and 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5    N
800 and 1000 4,8 8,0 11,2 16,0 20,0 22,0 25,0    N
1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0    N
Report No.: AGC08009200601ES01
Page 85 of 94

1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0    N
1000 and 1250 6,4 10,0 14,2 20,0 25,0 28,0 32,0    N
1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0    N
1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0    N
1250 and 1600 8,4 12,6 18,0 25,0 32,0 36,0 40,0    N
1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0    N
1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0    N
1600 and 2000 11,2 16,0 22,0 32,0 40,0 44,0 50,0    N
2000 and 2500 7,5 10,0 14,0 20,0 25, 0 28,0 32,0    N
2000 and 2500 7,5 10,0 14,0 20,0 25, 0 28,0 32,0    N
2000 and 2500 15,0 20,0 28,0 40,0 50,0 56,0 64,0    N
2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0    N
2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0    N
>2500 and 3200 20,0 25,0 36,0 50,0 64,0 72,0 80,0    N
3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0    N
3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0    N
3200 and 4000 25,0 32,0 44,0 64,0 80,0 90,0 100,0    N
4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0    N
4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0    N
4000 and 5000 32,0 40,0 56,0 80,0 100,0 112,0 126,0    N
5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0    N
5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0    N
5000 and 6300 40,0 50,0 72,0 100,0 126,0 142,0 160,0    N
6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0    N
6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0    N
6300 and 8000 50,0 64,0 90,0 126,0 160,0 180,0 200,0    N
8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0    N
8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0    N
8000 and 10000 64,0 80,0 112,0 160,0 200,0 220,0 250,0    N
10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0    N
10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0    N
10000 and 12500 80,0 100,0 142,0 200,0 250,0 280,0 320,0    N
Supplementary information:
*) Material group IIIb is allowed if the working voltage does not exceed 50 V
**) B = Basic insulation, S = Supplementary insulation, R = Reinforced insulation
Report No.: AGC08009200601ES01
Page 86 of 94

29.2 TABLE: Creepage distances, functional insulation N


Working voltage (V) Creepage distance (mm) Pollution degree --
1 2 3 --
Material group Material group --
Verdict /
I II IIIa/IIIb I II IIIa/IIIb
Remark
50 0,2 0,6 0,8 1,1 1,4 1,6 1,8 N

50 and 125 0,3 0,7 1,0 1,4 1,8 2,0 2,2 N

125 and 250 0,4 1,0 1,4 2.0 2,5 2,8 3,2 N
250 and 400 0,8 1,6 2,2 3,2 4,0 4,5 5,0 N

400 and 500 1,0 2,0 2,8 4,0 5,0 5,6 6,3 N

500 and 800 1,8 3,2 4,5 6,3 8,0 9,0 10,0 N

800 and 1000 2,4 4,0 5,6 8,0 10,0 11,0 12,5 N

1000 and 1250 3,2 5,0 7,1 10,0 12,5 14,0 16,0 N

1250 and 1600 4,2 6,3 9,0 12,5 16,0 18,0 20,0 N

1600 and 2000 5,6 8,0 11,0 16,0 20,0 22,0 25,0 N

2000 and 2500 7,5 10,0 14,0 20,0 25,0 28,0 32,0 N

2500 and 3200 10,0 12,5 18,0 25,0 32,0 36,0 40,0 N

3200 and 4000 12,5 16,0 22,0 32,0 40,0 45,0 50,0 N

4000 and 5000 16,0 20,0 28,0 40,0 50,0 56,0 63,0 N

5000 and 6300 20,0 25,0 36,0 50,0 63,0 71,0 80,0 N

6300 and 8000 25,0 32,0 45,0 63,0 80,0 90,0 100,0 N

8000 and 10000 32,0 40,0 56,0 80,0 100,0 110,0 125,0 N

10000 and 12500 40,0 50,0 71,0 100,0 125,0 140,0 160,0 N

Supplementary information:
*) Material group IIIb is allowed if the working voltage does not exceed 50 V

30.1 TABLE: Ball Pressure Test of Thermoplastics P


Allowed impression diameter (mm) ..................................... : 2.0 
Object/ Part No./ Material Test temperature (C) Impression diameter (mm)
Plastics Enclosure 76 0.5
Supplementary information:

30.2 TABLE: RESISTANCE TO HEAT AND FIRE - GLOW WIRE TESTS P


Object/
Part No./ Glow wire test (WT); (°C) Verdict
Material
550 650°C 750°C 850°C
Report No.: AGC08009200601ES01
Page 87 of 94

te ti te ti
Enclosure plastics P N N N N N P

Object/ Glow-wire flammability index GW ignition temp.


Part No./ (GWFI), °C (GWIT), °C Verdict
Material 550 650 750 850 675 775

-- -- -- -- -- -- -- --

The test specimen passed the glow wire test (GWT) with no ignition [(te – ti) ≤ 2s] (Yes/No) : --

If no, then surrounding parts passed the needle-flame test of annex E (Yes/No) : --
The test specimen passed the test by virtue of most of the flaming material being withdrawn with the
--
glow-wire (Yes/No) :
Ignition of the specified layer placed underneath the test specimen (Yes/No) : --
Supplementary information:
- 550 °C GWT not relevant (or applicable) to parts of material classified at least HB40 or if relevant HBF
- The GWIT pre-selection option, the 850 °C GWFI pre-selection option, and the 850 °C GWT are not relevant (or
applicable) for attended appliances
Report No.: AGC08009200601ES01
Page 88 of 94

Attachment A
Photos of product

Fig.1 – Overall view

Fig.2 – Part view


Report No.: AGC08009200601ES01
Page 89 of 94

Fig.3 – Part view

Fig.4 – Part view


Report No.: AGC08009200601ES01
Page 90 of 94

Fig.5 – Part view(Red frame is Label position)

Fig.6 – Part view


Report No.: AGC08009200601ES01
Page 91 of 94

Fig.7 – Part view

Fig.8 – Part view


Report No.: AGC08009200601ES01
Page 92 of 94

Fig.9 – Part view

Fig.10 – Part view


Report No.: AGC08009200601ES01
Page 93 of 94

Fig.11 – Part view

Fig.12 – Part view


Report No.: AGC08009200601ES01
Page 94 of 94

Fig.13 – Part view

Fig.14 – Part view

----- End of Report -----


Page 1 of 82

Safety Test Report

Report No.: AGC08009200601ES02

PRODUCT DESIGNATION : USB humidifer with mood light

BRAND NAME : N/A

MODEL NAME : MO9406

APPLICANT : Mid Ocean Brands B.V.

DATE OF ISSUE : Jul,16, 2020


EN 60598-2-4:2018,
STANDARD(S) :
EN 60598-1:2015+A1:2018,
REPORT VERSION : V1.0

Attestation of Global Compliance (Shenzhen) Co., Ltd.

CAUTION:
This report shall not be reproduced except in full without the written permission of the test
laboratory and shall not be quoted out of context.
Report No.: AGC08009200601ES02
Page 2 of 82

TEST REPORT
EN 60598-2-4
Luminaires
Part 2: Particular requirements
Section 4: Portable general purpose luminaires
Report reference No...................................... .: AGC08009200601ES02

Tested by (+ signature) .................................... : Mody Mo

Reviewed by (+ signature) ............................... : Phil Zhang

Matte He
Approved by (+ signature)................................ :
(Authorized officer )
Date of issue ................................................. : Jul.16, 2020
Contents ....................................................... ..: Total 82 pages
Testing laboratory
Name ............................................................ ..: Attestation of Global Compliance (Shenzhen) Co., Ltd.
Address ....................................................... ..: 1-2/F, Building 19, Junfeng Industrial Park, Chongqing
Road, Heping Community, Fuhai Street, Bao 'an District,
Shenzhen, Guangdong, China
Test location ................................................. ..: Same as above
Applicant
Name ........................................................... ..: Mid Ocean Brands B.V.
Address ....................................................... ..: 7/F.,King Tower,111King Lam Street,Cheung
ShaWan,Kowloon,HongKong.
Manufacturer
Name ........................................................... ..: Mid Ocean Brands B.V.
Address ....................................................... ..: 7/F.,King Tower,111King Lam Street,Cheung
ShaWan,Kowloon,HongKong.
Factory
Name ...................................................... ..: Mid Ocean Brands B.V.
Address ................................................... ..: 7/F.,King Tower,111King Lam Street,Cheung
ShaWan,Kowloon,HongKong.
Test specification
EN 60598-2-4:2018,
Standard ......................................................... :
EN 60598-1:2015+A1:2018,
Test procedure ............................................. ..: Type test
Procedure deviation ..................................... ..: N/A
Non-standard test method............................ ..: N/A
Report No.: AGC08009200601ES02
Page 3 of 82

Test Report Form/blank test report


Test Report Form No ................................... ..: AGC60598-2-4A6
TRF originator ............................................. ..: AGC
Master TTRF .................................................... : Dated 2019-01
Test item
Product designation ....................................... : USB humidifer with mood light
Brand name ................................................... : N/A
Test model .................................................... : MO9406
Series models ................................................ : N/A
Rating(s) ........................................................ : DC5V,0.5A
Test item Particulars
Classification of installation and use ............. : Portable light
Supply connection ......................................... : Appliance inlet
Protection class ............................................. : Class III
Protection against ingress of water ................. : IP20
Test case verdicts
Test case does not apply to the test object ... : N(/A)
Test item does meet the requirement ........... : P(ass)
Test item does not meet the requirement ...... : F(ail)
Testing
Date of receipt of test item .............................. : Jun.22,2020
Date(s) of performance of test ........................ : Jun.22 -Jul.12, 2020
Attachments
Attachment A .................................................. : Test report of EN 61347-2-11:2001
Attachment B .................................................. : Test report of EN 62031:2013+A2:2015
Attachment C ................................................. : Test report of IEC TR 62778:2014
Attachment D ................................................. : Photo of product
General remarks
This test report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item tested.
“(see remark #)” refers to a remark appended to the report.
“(see appended table)” refers to a table appended to the report.
Throughout this report a comma is used as the decimal separator.
Report Revise Record:
Report Version Revise Time Issued Date Valid Version Notes

V1.0 / Jul,16, 2020 Valid Initial release


Report No.: AGC08009200601ES02
Page 4 of 82

General product information


The product is class III equipment, The main body of the appliance is a humidifier, with a USB output port,
which can be connected to a DC fan or LED light. It is for indoor used only.
The appliance can be DC fan, it is test according to EN 60335, Refer to test report No.:
AGC08009200601ES01
Luminaire stability is assessment of installation methods in the installation instructions in this report.

Summary of testing
According clause 4.2.2 of EN 62493:2015, lighting equipment deemed to comply with the requirements of EN
62493:2015 without testing.
The retinal blue light hazard is assessed according to IEC/TR 62778.
Copy of marking plate

USB humidifer with mood light


Model: MO9406
Rating: 5V 0.5A
Mid Ocean Brands B.V.
7/F., King Tower, 111King Lam Street,
Cheung ShaWan, Kowloon, HongKong.
Importer: XXXX Address: XXXX

Made In China

Remark:
1) The CE marking and WEEE symbol (if any) should be at least 5mm and 7mm respectively in height.
2) The markings and instructions are the minimum requirements required by safety standard. For final
production samples, the additional markings which do not give rise to misunderstanding may be added.
3) As declared by the applicant, the importer (and manufacturer, if it is different)’s name, registered trade
name or mark and the postal address will be marked on the products before being place on the market.
4) Marking on the packaging or in a document accompanying the electrical equipment is only acceptable if it
is not possible to place such markings on the product.
Report No.: AGC08009200601ES02
Page 5 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
4.4 (0) GENERAL TEST REQUIREMENTS
4.4 (0.3) More sections applicable ............................................ : Yes No 
Section/s:
4.4 (0.7) Information for luminaire design in light sources standards 
4.4 (0.7.2) Light source safety standard ................................... : EN62031 
IEC TR62778
Luminaire design in the light source safety standard 

4.5 (2) CLASSIFICATION OF LUMINAIRES P


4.5 (2.2) Type of protection ................................................... : Class III 
4.5 (2.3) Degree of protection................................................. : IP20 
4.5 (2.4) Luminaire suitable for direct mounting on normally Yes No 
flammable surfaces .................................................. :
4.5 (2.5) Luminaire for normal use ........................................ : Yes No 
Luminaire for rough service ..................................... : Yes No 
4.5.1 (-) Ordinary luminaire .................................................... : Yes No 
4.5.2 (-) Portable luminaire for outdoor use ........................... : Yes No 
Classified IPX4 or higher 
4.5.3 (2.4) Luminaire suitable for direct mounting on normally Yes No 
flammable surfaces .................................................. :

4.6 (3) MARKING P


4.6 (3.2) Mandatory markings P
Position of the marking P
Format of symbols/text P
4.6 (3.3) Additional information P
Language of instructions English P
4.6 (3.3.1) Combination luminaires N
4.6 (3.3.2) Nominal frequency in Hz 5VDC N
4.6 (3.3.3) Operating temperature N
4.6 (3.3.5) Wiring diagram N
4.6 (3.3.6) Special conditions N
4.6 (3.3.7) Metal halide lamp luminaire – warning N
4.6 (3.3.8) Limitation for semi-luminaires N
Report No.: AGC08009200601ES02
Page 6 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
4.6 (3.3.9) Power factor and supply current N
4.6 (3.3.10) Suitability for use indoors P
4.6 (3.3.11) Luminaires with remote control N
4.6 (3.3.12) Clip-mounted luminaire – warning P
4.6 (3.3.13) Specifications of protective shields N
4.6 (3.3.14) Symbol for nature of supply P
4.6 (3.3.15) Rated current of socket outlet N
4.6 (3.3.16) Rough service luminaire N
4.6 (3.3.17) Mounting instruction for type Y, type Z and some Appliance inlet N
type X attachments
4.6 (3.3.18) Non-ordinary luminaires with PVC cable N
4.6 (3.3.19) Protective conductor current in instructions, if N
applicable
4.6 (3.3.20) Provided with information if not intended to be N
mounted within arm’s reach
4.6 (3.3.21) Non replaceable and non-user replaceable light Non-user replaceable light sources P
sources information provided
4.6 (3.3.22) Controllable luminaires, classification of insulation N
provided
4.6 (3.3.23) Luminaire without controlgear provided with P
necessary information for selection of appropriate
component
4.6 (3.3.24) If not supplied with terminal block, information on the N
packaging
4.6 (3.4) Test with water 15 s P
Test with hexane 15 s P
Legible after test P
Label attached P
4.6.1 (-) Luminaire not suitable for outdoor application P
Required symbol P
Information in the instructions P
4.6.2 (-) Outdoor use, socket outlet incorporated in the N
luminaire
Maximum power rating marked N
Position of the marking N
Report No.: AGC08009200601ES02
Page 7 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
4.7 (4) CONSTRUCTION P
4.7 (4.2) Components replaceable without difficulty P
4.7 (4.3) Wireways smooth and free from sharp edges P
4.7 (4.4) Lampholders N
4.7 (4.4.1) Integral lampholder N
4.7 (4.4.2) Wiring connection N
4.7 (4.4.3) Lampholder for end-to-end mounting N
4.7 (4.4.4) Positioning N
- pressure test (N) ................................................... : 
After test the lampholder comply with relevant N
standard sheets and show no damage
After test on single-capped lampholder the N
lampholder have not moved from its position and
show no permanent deformation
- bending test (N) .................................................... : 
After test the lampholder have not moved from its N
position and show no permanent deformation
4.7 (4.4.5) Peak pulse voltage N
4.7 (4.4.6) Centre contact N
4.7 (4.4.7) Parts in rough service luminaires resistant to tracking N
4.7 (4.4.8) Lamp connectors N
4.7 (4.4.9) Caps and bases correctly used N
4.7 (4.4.10) Light source for lampholder or connection according N
IEC 60061 not connected another way
4.7 (4.5) Starter holders N
Starter holder in luminaires other than class II N
Starter holder class II construction N
4.7 (4.6) Terminal blocks N
Tails N
Unsecured blocks N
4.7 (4.7) Terminals and supply connections P
4.7 (4.7.1) Contact to metal parts N
4.7 (4.7.2) Test 8 mm live conductor N
Test 8 mm earth conductor N
4.7 (4.7.3) Terminals for supply conductors N
Report No.: AGC08009200601ES02
Page 8 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
4.7 (4.7.3.1) Welded method and material P
- stranded or solid conductor P
- spot welding P
- welding between wires N
- Type Z attachment N
- mechanical test according to 15.6.2 N
- electrical test according to 15.6.3 N
- heat test according to 15.6.3.2.3 and 15.6.3.2.4 N
4.7 (4.7.4) Terminals other than supply connection N
4.7 (4.7.5) Heat-resistant wiring/sleeves N
4.7 (4.7.6) Multi-pole plug N
- test at 30 N N
4.7 (4.8) Switches P
- adequate rating P
- adequate fixing P
- polarized supply N
- compliance with IEC 61058-1 for electronic N
switches
4.7 (4.9) Insulating lining and sleeves N
4.7 (4.9.1) Retainment N
Method of fixing ........................................................ : N
4.7 (4.9.2) Insulated linings and sleeves: N
Resistant to a temperature > 20 C to the wire N
temperature or
a) & c) Insulation resistance and electric strength N
b) Ageing test. Temperature (C) ............................. : N
4.7 (4.10) Double or reinforced insulation Class III luminaire N
4.7 (4.10.1) No contact, mounting surface – accessible metal N
parts – wiring of basic insulation
Safe installation fixed luminaires N
Capacitors and switches N
Interference suppression capacitors according to IEC N
60384-14
4.7 (4.10.2) Assembly gaps: N
- not coincidental N
Report No.: AGC08009200601ES02
Page 9 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
- no straight access with test probe N
4.7 (4.10.3) Retainment of insulation: N
- fixed N
- unable to be replaced; luminaire inoperative N
- sleeves retained in position N
- lining in lampholder N
4.7 (4.10.4) Protective impedance device N
Double or reinforced insulation bridged by N
appropriate and at least two resistors or two Y2
capacitors or one Y1 capacitor
Y1 or Y2 capacitors comply with IEC 60384-14 N
Resistors comply with test (a) in 14.1 of IEC 60065 N
4.7 (4.11) Electrical connections and current-carrying parts P
4.7 (4.11.1) Contact pressure P
4.7 (4.11.2) Screws: P
- self-tapping screws P
- thread-cutting screws N
4.7 (4.11.3) Screw locking: N
- spring washer N
- rivets N
4.7 (4.11.4) Material of current-carrying parts Copper alloy P
4.7 (4.11.5) No contact to wood or mounting surface P
4.7 (4.11.6) Electro-mechanical contact systems N
4.7 (4.12) Screws and connections (mechanical) and glands P
4.7 (4.12.1) Screws not made of soft metal P
Screws of insulating material P
Torque test: torque (Nm); part.................................. : Screw for fix enclosure,2.34mm, P
0.4Nm
Torque test: torque (Nm); part.................................. : Screw for fix control P
PCB,1.76mm,0.4Nm
Torque test: torque (Nm); part.................................. : N
4.7 (4.12.2) Screws with diameter < 3 mm screwed into metal N
4.7 (4.12.4) Locked connections: N
- fixed arms; torque (Nm) ......................................... : N
- lampholder; torque (Nm) ........................................ : N
Report No.: AGC08009200601ES02
Page 10 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
- push-button switches; torque 0,8 Nm .................... : N
4.7 (4.12.5) Screwed glands; force (Nm)..................................... : N
4.7 (4.13) Mechanical strength P
4.7 (4.13.1) Impact tests: P
- fragile parts; energy (Nm) ...................................... : N
- other parts; energy (Nm) ........................................ : Plastic enclosure:0.5Nm P
1) live parts P
2) linings P
3) protection P
4) covers N
4.7 (4.13.2) Metal parts have adequate mechanical strength N
4.7 (4.13.3) Straight test finger P
4.7 (4.13.4) Rough service luminaires N
- IP54 or higher N
a) fixed N
b) hand-held N
c) delivered with a stand N
d) for temporary installations and suitable for N
mounting on a stand
4.7 (4.13.6) Tumbling barrel N
4.7 (4.14) Suspensions, fixings and means of adjusting P
4.7 (4.14.1) Mechanical load: N
A) four times the weight N
B) torque 2,5 Nm N
C) bracket arm; bending moment (Nm) ................... : N
D) load track-mounted luminaires N
E) clip-mounted luminaires, glass-shelve. —
Thickness (mm) ....................................................... :
Metal rod. diameter (mm) ........................................ : N
Fixed luminaire or independent control gear without N
fixing devices
4.7 (4.14.2) Load to flexible cables N
Mass (kg) ................................................................. : —
Stress in conductors (N/mm²) ................................. : N
Report No.: AGC08009200601ES02
Page 11 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
Mass (kg) of semi-luminaire .................................... : N
Bending moment (Nm) of semi-luminaire ............... : N
4.7 (4.14.3) Adjusting devices: P
- flexing test; number of cycles................................. : 1500 cycles P
- strands broken ....................................................... : No P
- electric strength test afterwards P
4.7 (4.14.4) Telescopic tubes: cords not fixed to tube; no strain N
on conductors
4.7 (4.14.5) Guide pulleys N
4.7 (4.14.6) Strain on socket-outlets N
4.7 (4.15) Flammable materials P
- glow-wire test 650C .............................................. : See Test Table 3.15 (13.3.2) P
- spacing 30 mm N
- screen withstanding test of 13.3.1 N
- screen dimensions N
- no fiercely burning material P
- thermal protection N
- electronic circuits exempted N
4.7 (4.15.2) Luminaires made of thermoplastic material with lamp control gear N
a) construction N
b) temperature sensing control N
c) surface temperature N
4.7 (4.16) Luminaires for mounting on normally flammable surfaces P
No lamp control gear ................................................ : (compliance with Section 12) N
Provided with adaptor for a track meet the N
requirements for direct mounting on normally
flammable surfaces
4.7 (4.16.1) Lamp control gear spacing: N
- spacing 35 mm N
- spacing 10 mm N
4.7 (4.16.2) Thermal protection: N
- in lamp control gear N
- external N
- fixed position N
Report No.: AGC08009200601ES02
Page 12 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
- temperature marked lamp control gear N
4.7 (4.16.3) Design to satisfy the test of 12.6 ............................. : (see clause 12.6) N
4.7 (4.17) Drain holes N
Clearance at least 5 mm N
4.7 (4.18) Resistance to corrosion N
4.7 (4.18.1) - rust-resistance N
4.7 (4.18.2) - season cracking in copper N
4.7 (4.18.3) - corrosion of aluminium N
4.7 (4.19) Ignitors compatible with ballast N
4.7 (4.20) Rough service vibration N
4.7 (4.21) Protective shield N
4.7 (4.21.1) Shield fitted if tungsten halogen lamps or metal N
halide lamps
Shield of glass if tungsten halogen lamps N
4.7 (4.21.2) Particles from a shattering lamp not impair safety N
4.7 (4.21.3) No direct path N
4.7 (4.21.4) Impact test on shield N
Glow-wire test on lamp compartment ...................... : See Test Table 3.15 (13.3.2) N
4.7 (4.22) Attachments to lamps not cause overheating or N
damage
4.7 (4.23) Semi-luminaires comply Class II N
4.7 (4.24) Photobiological hazards P
4.7 (4.24.1) No excessive UV radiation if tungsten halogen lamps N
and metal halide lamps (Annex P)
4.7 (4.24.2) Retinal blue light hazard P
Class of risk group assessed according to IEC/TR RG0 —
62778 ......................................................................:
Luminaires with Ethr : N
a) Fixed luminaires N
- distance x m, borderline between RG1 and RG2 .. : N
- marking and instruction according 3.2.23 N
b) Portable and handheld luminaires It is classified as RG0, not N
necessary to access the retinal
blue light hazard
- marking according 3.2.23 if RG1 exceeded at 200 N
mm according to IEC/TR 62778
Report No.: AGC08009200601ES02
Page 13 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
Portable luminaires for children IEC 60598-2-10 and
Mains socket outlet nightlights IEC 60598-2-12 not N
exceed RG1 at 200 mm according to IEC/62778
4.7 (4.25) Mechanical hazard P
No sharp point or edges P
4.7 (4.26) Short-circuit protection N
4.7 (4.26.1) Adequate means of uninsulated accessible SELV N
parts
4.7 (4.26.2) Short-circuit test with test chain according 4.26.3 N
Test chain not melt through N
Test sample not exceed values of Table 12.1 and N
12.2
4.7 (4.27) Terminal blocks with integrated screwless earthing contacts N
Test according Annex V N
Pull test of terminal fixing (20 N) N
After test, resistance < 0,05  N
Pull test of mechanical connection (50 N) N
After test, resistance < 0,05  N
Voltage drop test, resistance < 0,05  N
4.7 (4.28) Fixing of thermal sensing control N
Not plug-in or easily replaceable type N
Reliably kept in position N
No adhesive fixing if UV radiations from a lamp can N
degrade the fixing
Not outside the luminaire enclosure N
Test of adhesive fixing: N
Max. temperature on adhesive material (C) .......... : —
100 cycles between t min and t max N
Temperature sensing control still in position N
4.7 (4.29) Luminaires with non-replaceable light source N
Not possible to replace light source N
Live part not accessible after parts have been N
opened by hand or tools
4.7 (4.30) Luminaires with non-user replaceable light source P
If protective cover provide protection against electric shock and marked with “caution, P
electric shock risk” symbol:
Report No.: AGC08009200601ES02
Page 14 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
Minimum two fixing means P
4.7 (4.31) Insulation between circuits Class III luminaire N
Circuits insulated from LV supply fulfil requirements N
according 4.31.1 – 4.31.3
Controllable luminaires requiring same level of N
insulation for all components, the insulation between
control terminals and LV supply fulfil requirements
according 4.31.1 – 4.31.3
4.7 (4.31.1) SELV circuits N
Used SELV source N
Voltage ≤ ELV N
Insulating of SELV circuits from LV supply N
Insulating of SELV circuits from other non SELV N
circuits
Insulating of SELV circuits from FELV N
Insulating of SELV circuits from other SELV circuits N
SELV circuits insulated from accessible parts N
according Table X.1
Plugs not able to enter socket-outlets of other N
voltage systems
Socket outlets does not admit plugs of other voltage N
systems
Plugs and socket-outlets does not have protective N
conductor contact
4.7 (4.31.2) FELV circuits N
Used FELV source N
Voltage ≤ ELV N
Insulating of FELV circuits from LV supply N
FELV circuits insulated from accessible parts N
according Table X.1
Plugs not able to enter socket-outlets of other N
voltage systems
Socket outlets does not admit plugs of other voltage N
systems
Socket-outlets does not have protective conductor N
contact
4.7 (4.31.3) Other circuits N
Report No.: AGC08009200601ES02
Page 15 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
Other circuits insulated from accessible parts N
according Table X.1
Class II construction with equipotential bonding for protection against indirect contacts N
with live parts:
- conductive parts are connected together N
- test according 7.2.3 N
- conductive part not cause an electric shock in case N
of an insulation fault
- equipotential bonding in master/slave applications N
- master luminaire provided with terminal for N
accessible conductive parts of slave luminaires
- slave luminaire constructed as class I N
4.7 (4.32) Overvoltage protective devices N
Comply with IEC 61643-11 N
External to controlgear and connected to earth: N
- only in fixed luminaires N
- only connected to protective earth N
4.7.1 (-) Insulation not damaged when moving, adjusting or P
placing on support
4.7.2 (-) Wiring fixed, to avoid rubbing P
Carrier or clips of insulation material or with P
insulating lining
4.7.3 (-) Luminaire not overturn at angle 6 Assessment of installation methods P
in the installation instructions
Outdoor use luminaire not overturn at an angle 15° N
4.7.4 (-) Candlestick luminaires with E5 or E10 lampholders N
provided with a switch
Switch part of the luminaire or within 300 mm of the N
luminaire if with cord
4.7.5 (-) Voltage not exceeding 25 V for E5 lampholders N
E10 lampholder voltage: N
- not exceeding 60 V for series connection) or N
- not exceeding 250 V for parallel connections N
Maximum rated wattage not exceed 100 W N
4.7.6 (-) Portable luminaires for outdoor use tails not provided N
4.7.7 (-) Portable luminaires for outdoor use, cable entries N
Report No.: AGC08009200601ES02
Page 16 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
4.7.8 (-) Portable luminaires for outdoor use, socket-outlet N
degree of protection at least same as the luminaire
but not less than IPX4.
Degree of protection maintained with or without a N
plug inserted into the socket-outlet.
Class Il luminaires, mains socket-outlets comply with N
the standard and only allow connection to Class Il
luminaires
Class l luminaires, mains socket-outlets comply with N
the standard and only allow connection to Class l or
Class II luminaires
4.7.9 (-) Portable luminaires for outdoor use, lampholders and N
plugs are of material resistant to tracking
Compliance to clause 13.4 N

4.8 (11) CREEPAGE DISTANCES AND CLEARANCES P


Impulse withstand category (Normal category II) Category II Category III 
(Category III Annex U, Table U.1) ........................... :
4.8 (11.2.1) Category III according Annex U P

Protected against pollution, reduced creepage and N


clearance according Annex P of IEC 61347-1
4.7 (11.2.2) Creepage distances for frequency up to 30 kHz ...... : See Test Table 4.7 (11.2) I N

Creepage distances for frequency over 30 kHz: N

- Controlgear marked with ÛOUT and fUOUT according See Test Table 4.7 (11.2) II N
IEC 61347-1, clause 7.1, item w) ............................. :
- Requirements according IEC 60664-4 for See Test Table 4.7 (11.2) II N
controlgear not covered by IEC 61347 .................... :
4.7 (11.2.3) Clearances for frequency up to 30 kHz.................... : See Test Table 4.7 (11.2) I N

Clearances distances for frequency over 30 kHz: N

- Controlgear marked with UP................................... :: See Test Table 4.7 (11.2) II N

- Requirements according IEC 60664-4 for See Test Table 4.7 (11.2) II N
controlgear not covered by IEC 61347 .................... :

4.9 (7) PROVISION FOR EARTHING Class III luminaires N


4.9 (7.2.1 Accessible metal parts N
+ 7.2.3)
Metal parts in contact with supporting surface N
Resistance < 0,5 ................................................... : N
Report No.: AGC08009200601ES02
Page 17 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
Self-tapping screws used N
Thread-forming screws N
Thread-forming screw used in a grove N
Earth makes contact first N
Terminal blocks with integrated screwless earthing N
contacts tested according Annex V
Protective earthing of the luminaire not via built-in N
control gear
4.9 (7.2.2 Earth continuity in joints, etc. N
+ 7.2.3)
4.9 (7.2.4) Locking of clamping means N
Compliance with 4.7.3 N
Terminal blocks with integrated screwless earthing N
contacts tested according Annex V
4.9 (7.2.5) Earth terminal integral part of connector socket N
4.9 (7.2.6) Earth terminal adjacent to mains terminals N
4.9 (7.2.7) Electrolytic corrosion of the earth terminal N
4.9 (7.2.8) Material of earth terminal N
Contact surface bare metal N
4.9 (7.2.10) Class II luminaire for looping-in N
Double or reinforced insulation to functional earth N
4.9 (7.2.11) Earthing core coloured green-yellow N
Length of earth conductor N

4.10 (14) SCREW TERMINALS N


Separately approved; component list....................... : (see Annex 1) N
Part of the luminaire ................................................. : (see Annex 3) N

4.10 (15) SCREWLESS TERMINALS AND ELECTRICAL CONNECTIONS N


Separately approved; component list....................... : (see Annex 1) N
Part of the luminaire ................................................. : (see Annex 4) N

4.11 (5) EXTERNAL AND INTERNAL WIRING P


4.11 (5.2) Supply connection and external wiring N
4.11 (5.2.1) Means of connection ................................................ : Appliance inlet N
Report No.: AGC08009200601ES02
Page 18 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
Outdoor luminaire has not PVC insulated external N
wiring if not class III or SELV ≤ 25 V a.c./60 V d.c. or
protected from outdoor environment
4.11 (5.2.2) Type of cable ............................................................ : N
Nominal cross-sectional area (mm²) ........................ : N
Cables equal to IEC 60227 or IEC 60245 N
4.11 (5.2.3) Type of attachment, X, Y or Z .................................. : Appliance inlet N
4.11 (5.2.5) Type Z not connected to screws N
4.11 (5.2.6) Cable entries: N
- suitable for introduction N
- adequate degree of protection N
4.11 (5.2.7) Cable entries through rigid material have rounded N
edges
4.11 (5.2.8) Insulating bushings: N
- suitably fixed N
- material in bushings N
- material not likely to deteriorate N
- tubes or guards made of insulating material N
4.11 (5.2.9) Locking of screwed bushings N
4.11 Cord anchorage: N
(5.2.10)
- covering protected from abrasion N
- clear how to be effective N
- no mechanical or thermal stress N
- no tying of cables into knots etc. N
- insulating material or lining N
4.11 Cord anchorage for type X attachment: N
(5.2.10.1)
a) at least one part fixed N
b) types of cable N
c) no damaging of the cable N
d) whole cable can be mounted N
e) no touching of clamping screws N
f) metal screw not directly on cable N
g) replacement without special tool N
Report No.: AGC08009200601ES02
Page 19 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
Glands not used as anchorage N
Labyrinth type anchorages N
4.11 Adequate cord anchorage for type Y and type Z N
(5.2.10.2) attachment
4.11 Tests: N
(5.2.10.3)
- impossible to push cable; unsafe N
- pull test: 25 times; pull (N) ..................................... : N
- torque test: torque (Nm) ......................................... : N
- displacement  2 mm N
- no movement of conductors N
- no damage of cable or cord N
- function independent of electrical connection N
4.11 External wiring passing into luminaire N
(5.2.11)
4.11 Looping-in terminals N
(5.2.12)
4.11 Wire ends not tinned N
(5.2.13)
Wire ends tinned: no cold flow N
4.11 Mains plug same protection N
(5.2.14)
Class III luminaire plug N
No unsafe compatibility N
4.11 Appliance inlets (IEC 60320) N
(5.2.16)
Installation couplers (IEC 61535) N
Other appliance inlet or connector according relevant N
IEC standard
4.11 No standardized interconnecting cables properly N
(5.2.17) assembled
4.11 Used plug in accordance with N
(5.2.18)
- IEC 60083 N
- other standard N
4.11 (5.3) Internal wiring P
4.11 (5.3.1) Internal wiring of suitable size and type P
Report No.: AGC08009200601ES02
Page 20 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
Through wiring N
- not delivered/ mounting instruction N
- factory assembled N
- socket outlet loaded (A) ......................................... : N
- temperatures .......................................................... : (see Annex 2) N
Green-yellow for earth only N
4.11 Internal wiring connected directly to fixed wiring P
(5.3.1.1)
Cross-sectional area (mm²)...................................... : >0.4mm² P
Insulation thickness P
Extra insulation added where necessary N
4.11 Internal wiring connected to fixed wiring via internal current-limiting device N
(5.3.1.2)
Cross-sectional area (mm²)................................... : N
4.11 Double or reinforced insulation for class II N
(5.3.1.3)
4.11 Conductors without insulation N
(5.3.1.4)
4.11 SELV current-carrying parts P
(5.3.1.5)
4.11 Insulation thickness other than PVC or rubber N
(5.3.1.6)
4.11 (5.3.2) Sharp edges etc. P
No moving parts of switches etc. P
Joints, raising/lowering devices N
Telescopic tubes etc. N
No twisting over 360 P
4.11 (5.3.3) Insulating bushings: N
- suitable fixed N
- material in bushings N
- material not likely to deteriorate N
- cables with protective sheath N
4.11 (5.3.4) Joints and junctions effectively insulated N
4.11 (5.3.5) Strain on internal wiring N
4.11 (5.3.6) Wire carriers N
Report No.: AGC08009200601ES02
Page 21 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
4.11 (5.3.7) Wire ends not tinned P
Wire ends tinned: no cold flow N
4.11 (5.4) Test to determine suitability of conductors having a reduced cross-sectional area N
Under test the temperature of the luminaire wiring (see Annex 2) N
insulation not exceed the limits stated in Table 12.2
No damage to luminaire wiring after test N
4.11.1 (-) Indoor use luminaire 
The requirement of one part of cord anchorage to be
fixed to the luminaire not applied for table lamps of
glass or ceramic
4.11.2 (-) Class I and class II indoor use N
Luminaire with a mass less than 1 kg the current
≤ 2,5 A and cable ≤ 2 m and conductor ≥ 0,5 mm²
4.11.3 (-) Terminals, a cord anchorage and an inlet opening for N
the proper connection of the flexible cable or cord if
for outdoor use and delivered without a flexible cable
or cord and a plug.
4.11.4 (-) Portable luminaires for outdoor use N
Insulation class I and class II, non-detachable flexible
cables or cords at least type 245 IEC 57.

4.12 (8) PROTECTION AGAINST ELECTRIC SHOCK P


4.12 (8.2.1) Live parts not accessible P
Basic insulated parts not used on the outer surface P
without appropriate protection
Basic insulated parts not accessible with standard P
test finger on portable, settable and adjustable
luminaires
Basic insulated parts not accessible with Ø 50 mm N
probe from outside, other types of luminaires
Lamp and starter holders in portable and adjustable N
luminaires comply with double or reinforced
insulation requirements
Basic insulation only accessible under lamp or starter N
replacement
Protection in any position P
Double-ended tungsten filament lamp N
Insulation lacquer not reliable N
Double-ended high pressure discharge lamp N
Report No.: AGC08009200601ES02
Page 22 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
Relevant warning according to 3.2.18 fitted to the N
luminaire
4.12 (8.2.2) Portable luminaire adjusted in most unfavourable P
position
4.12 Class II luminaire: N
(8.2.3.a)
- basic insulated metal parts not accessible during N
starter or lamp replacement
- basic insulation not accessible other than during N
starter or lamp replacement
- glass protective shields not used as supplementary N
insulation
4.12 BC lampholder of metal in class I luminaires is N
(8.2.3.b) earthed
4.12 SELV circuits with exposed current carrying parts: N
(8.2.3.c)
Ordinary luminaire: N
- voltage under load (V)............................................ : N
- no-load voltage (V)................................................. : N
- touch current if applicable (mA) ............................ : N
One conductive part insulated if required N
Other than ordinary luminaire: N
- nominal voltage (V) ............................................... : N
Class III luminaire only for connection to SELV N
Class III luminaire not provided with means for N
protective earthing
4.12 (8.2.4) Portable luminaire have protection independent of P
supporting surface
4.12 (8.2.5) Compliance with the standard test finger or relevant P
probe
4.12 (8.2.6) Covers reliably secured N
4.12 (8.2.7) Luminaire other than below with capacitor  0,5 F N
not exceed 50 V 1 min after disconnection
Portable luminaire with capacitor  0,1 F (0.25) not N
exceed 34 V 1 s after disconnection
Other luminaires with capacitor  0,1 F (0.25) with N
plug and track adaptors not exceed 60 V 5 s after
disconnection
4.12. (-) Class I luminaire with bayonet lampholder: N
Report No.: AGC08009200601ES02
Page 23 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
1) cap not accessible with test finger N
2) metal lampholder is earthed N

4.13 (12) ENDURANCE TEST AND THERMAL TEST P


4.13 (-) If IP > IP 20 relevant test of (12.4), (12.5), (12.6) and (12.7) after (9.2) before (9.3) 
specified in 4.13
3.12 (12.2) Selection of lamps and ballasts 
Lamp used according Annex B ................................ : See Annex 2 for lamp used 
Controlgear if separate and not supplied ................. : See Annex 2 for controlgear used 
4.13 (12.3) Endurance test: P
a) mounting-position................................................. : As user manual 
b) test temperature (C) ........................................... : 35C 
c) total duration (h) ................................................... : 240h 
d) if not equipped with controlgear, constant 5.5V~ 
voltage/current (V) or (A) ......................................... :
e) luminaire ceases to operate LED module 
4.13 After endurance test: P
(12.3.2)
- no part unserviceable P
- luminaire not unsafe P
- no damage to track system N
- marking legible P
- no cracks, deformation etc. P
4.13 (12.4) Thermal test (normal operation) ........................... : (see Annex 2) P
4.13 (12.5) Thermal test (abnormal operation) ...................... : (see Annex 2) N
4.13 (12.6) Thermal test (failed lamp control gear condition): N
4.13 Through wiring or looping-in wiring loaded by a 
(12.6.1) current of (A) ........................................................... :
- case of abnormal conditions .................................. : 
- electronic lamp control gear N
- measured winding temperature (C): at 1,1 Un .... : 
- measured mounting surface temperature (C) at N
1,1 Un ....................................................................... :
- calculated mounting surface temperature (C) ..... : N
- track-mounted luminaires N
Report No.: AGC08009200601ES02
Page 24 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
4.13 Temperature sensing control N
(12.6.2)
- case of abnormal conditions .................................. : 
- thermal link N
- manual reset cut-out N
- auto reset cut-out N
- measured mounting surface temperature (C) ...... : N
- track-mounted luminaires N
4.13 (12.7) Thermal test (failed lamp control gear in plastic luminaires): N
4.13 Luminaire without temperature sensing control N
(12.7.1)
4.13 Luminaire with fluorescent lamp ≤ 70W N
(12.7.1.1)
Test method 12.7.1.1 or Annex W .......................... : 
Test according to 12.7.1.1: N
- case of abnormal conditions .................................. : 
- Ballast failure at supply voltage (V) ...................... : 
- Components retained in place after the test N
- Test with standard test finger after the test N
Test according to Annex W: N
- case of abnormal conditions .................................. : 
- measured winding temperature (C): at 1,1 Un ..... : 
- measured temperature of fixing point/exposed part 
(C): at 1,1 Un .......................................................... :
- calculated temperature of fixing point/exposed part 
(C) ........................................................................... :
Ball-pressure test .................................................. : See Table 3.15 (13.2.1) N
4.13 Luminaire with discharge lamp, fluorescent lamp > 70W, transformer > 10 VA N
(12.7.1.2)
- case of abnormal conditions .................................. : 
- measured winding temperature (C): at 1,1 Un ..... : 
- measured temperature of fixing point/exposed part 
(C): at 1,1 Un .......................................................... :
- calculated temperature of fixing point/exposed part 
(C) ........................................................................... :
Ball-pressure test ..................................................... : See Table 3.15 (13.2.1) N
Report No.: AGC08009200601ES02
Page 25 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
4.13 Luminaire with short circuit proof transformers N
(12.7.1.3) ≤ 10 VA
- case of abnormal conditions .................................. : 
- Components retained in place after the test N
- Test with standard test finger after the test N
4.13 Luminaire with temperature sensing control N
(12.7.2)
- thermal link ............................................................. : Yes No 
- manual reset cut-out .............................................. : Yes No 
- auto reset cut-out ................................................... : Yes No 
- case of abnormal conditions .................................. : 
- highest measured temperature of fixing point/ 
exposed part (C): .................................................... :
Ball-pressure test: .................................................... : See Table 3.15 (13.2.1) N
4.13 (-) Indoor use luminaire, Test overturned position N
(overturns < 15)

4.14 (9) RESISTANCE TO DUST AND MOISTURE P


4.14 (-) If IP > IP 20 the order of tests as specified in clause 4.12 N
4.14 (9.2) Tests for ingress of dust, solid objects and moisture: P
- classification according to IP.................................. : IP20 
- mounting position during test ................................. : As user manual 
- fixing screws tightened; torque (Nm) ..................... : 0.27 
- tests according to clauses...................................... : 
- electric strength test afterwards P
a) no deposit in dust-proof luminaire N
b) no talcum in dust-tight luminaire N
c) no trace of water on current-carrying parts or on N
insulation where it could become a hazard
c.1) For luminaires without drain holes – no water N
entry
c.2) For luminaires with drain holes – no hazardous N
water entry
d) no water in watertight or pressure watertight N
luminaire
e) no contact with live parts (IP 2X) P
Report No.: AGC08009200601ES02
Page 26 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
e) no entry into enclosure (IP 3X and IP 4X) N
e) no contact with live parts through drain holes and N
ventilation slots (IP3X and IP4X)
f) no trace of water on part of lamp requiring N
protection from splashing water
g) no damage of protective shield or glass envelope N
4.14 (9.3) Humidity test 48 h 25℃ ; 93%R.H. P
4.14 (-) Portable luminaire for outdoor use tested in the most N
unfavourable of the overturned positions likely to
occur

4.15 (10) INSULATION RESISTANCE AND ELECTRIC STRENGTH P


4.15 Insulation resistance test P
(10.2.1)
Cable or cord covered by metal foil or replaced by a 
metal rod of mm Ø .................................................. :
Insulation resistance (M) ....................................... : 
SELV P
- between current-carrying parts of different polarity : >100 M P
- between current-carrying parts and mounting >100 M P
surface...................................................................... :
- between current-carrying parts and metal parts of N
the luminaire ............................................................. :
- between the outer surface of a flexible cord or cable N
where it is clamped in a cord anchorage and
accessible metal parts.............................................. :
- Insulation bushings as described in Section 5 ...... : N
Other than SELV N
- between live parts of different polarity ................... : N
- between live parts and mounting surface .............. : N
- between live parts and metal parts ........................ : N
- between live parts of different polarity through N
action of a switch ...................................................... :
- between the outer surface of a flexible cord or cable N
where it is clamped in a cord anchorage and
accessible metal parts.............................................. :
- Insulation bushings as described in Section 5 ...... : N
Report No.: AGC08009200601ES02
Page 27 of 82

EN 60598-2-4
Clause Requirement  Test Result Verdict
4.15 Electric strength test P
(10.2.2)
Dummy lamp N
Luminaires with ignitors after 24 h test N
Luminaires with manual ignitors N
Test voltage (V) ........................................................ : P
SELV P
- between current-carrying parts of different polarity : 500V P
- between current-carrying parts and mounting 500V P
surface...................................................................... :
- between current-carrying parts and metal parts of N
the luminaire ............................................................. :
- between the outer surface of a flexible cord or cable N
where it is clamped in a cord anchorage and
accessible metal parts.............................................. :
- Insulation bushings as described in Section 5 ...... : N
Other than SELV N
- between live parts of different polarity ................... : N
- between live parts and mounting surface .............. : N
- between live parts and metal parts ........................ : N
- between live parts of different polarity through N
action of a switch ...................................................... :
- between the outer surface of a flexible cord or cable N
where it is clamped in a cord anchorage and
accessible metal parts.............................................. :
- Insulation bushings as described in Section 5 ...... : N
4.15 (10.3) Touch current or protective conductor current (mA).: Class III luminaire N

4.16 (13) RESISTANCE TO HEAT, FIRE AND TRACKING P


4.16 Ball-pressure test ..................................................... : See Test Table 4.15 (13.2.1) P
(13.2.1)
4.16 Needle-flame test (10 s) ........................................... : See Test Table 4.15 (13.3.1) P
(13.3.1)
4.16 Glow-wire test (650C) ............................................. : See Test Table 4.15 (13.3.2) P
(13.3.2)
4.16 (13.4) Proof tracking test (IEC 60112) ................................ : See Test Table 4.15 (13.4) N
Report No.: AGC08009200601ES02
Page 28 of 82

4.7 (11.2) TABLE I: Creepage distances and clearances P


Minimum distances (mm) for a.c. up to 30 kHz sinusoidal voltages P
Applicable part of IEC 60598-1 Table 11.1.A*, 11.1.B* and 11.2* N
Insulation Measured Required Measured Required
type ** clearance creepage
clearance *Table creepage *Table
Distance B >1.5 0.2 11.1B >1.5 1.2 11.1A
1:between
current-
carrying
parts and
mounting
surface
Working voltage (V) ...................................................................... : 5VDC 
PTI ................................................................................................ : < 600 > 600 
Pulse voltage or UP if applicable (kV) .......................................... : 
Supplementary information:
Distance 2:
Working voltage (V) ...................................................................... : 
PTI ................................................................................................ : < 600 > 600 
Pulse voltage or UP if applicable (kV) .......................................... : 
Supplementary information:
Distance 3:
Working voltage (V) ...................................................................... : 
PTI ................................................................................................ : < 600 > 600 
Pulse voltage or UP if applicable (kV) .......................................... : 
Supplementary information:
** Insulation type: B – Basic; S – Supplementary; R – Reinforced. See also IEC 60598-1 Annex

4.7 (11.2) TABLE II: Creepage distances and clearances N


Minimum distances (mm) for a.c. higher than 30 kHz sinusoidal voltages
Applicable part of IEC 61347-1 Table 7 and 8* or IEC 60664-4 Table 1 and 2
Distances Insulation Measured Required Measured Required
type ** clearance creepage
clearance *Table creepage *Table
Distance 1:
Working voltage (V) ...................................................................... : 
Frequency if applicable (kHz) ....................................................... : 
PTI ................................................................................................ : < 600 > 600 
Report No.: AGC08009200601ES02
Page 29 of 82

Peak value of the working voltage Ûout if applicable (kV) ............ : 


Supplementary information:
Distance 2:
Working voltage (V) ...................................................................... : 
Frequency if applicable (kHz) ....................................................... : 
PTI ................................................................................................ : < 600 > 600 
Peak value of the working voltage Ûout if applicable (kV) ............ : 
Supplementary information:
Distance 3:
Working voltage (V) ...................................................................... : 
Frequency if applicable (kHz) ....................................................... : 
PTI ................................................................................................ : < 600 > 600 
Peak value of the working voltage Ûout if applicable (kV) ............ : 
Supplementary information:
** Insulation type: B – Basic; S – Supplementary; R – Reinforced

4.15 P
TABLE: Ball Pressure Test of Thermoplastics
(13.2.1)
Allowed impression diameter (mm) ...................... : 2 
Object/ Part No./ Material Test temperature (C) Impression diameter (mm)
LED control PCB 125 0.8
LED PCB 125 0.8
Plastic enclosure 125 1.6
LED lens 75 1.0
Supplementary information:

4.15 P
TABLE: Needle-flame test (IEC 60695-11-5)
(13.3.1)
Object/ Part No./ Duration of Ignition of specified Duration of burning Verdict
Material application of test layer (tb)
flame (ta); (s) Yes/No (s)
LED control PCB 10 No No burning P
LED PCB 10 No No burning P
Plastic enclosure 10 No No burning P
Supplementary information:
Report No.: AGC08009200601ES02
Page 30 of 82

4.15 P
TABLE: Glow-wire test (IEC 60695-2-11)
(13.3.2)
Glow wire temperature ............................................ : 650°C 
Object/ Part No./ Manufacturer/ Ignition of Duration of
Material trademark specified layer burning (tb) Verdict
Yes/No (s)
Plastic enclosure See ANNEX 1 No 0 P
LED lens See ANNEX 1 No 0 P
Supplementary information:

4.15 (13.4) TABLE: Proof tracking test (IEC 60112) N


Test voltage PTI ...................................................... : 175 V 
Withstand 50 drops without failure on three
Object/ Part No./ Material Verdict
places or on three specimens

Supplementary information:

ANNEX 1 TABLE: Critical components information P


object/part No. Manufacturer/ Type/model Technical data Standard Mark(s) of
trademark conformity

PCB Various Various V-0,130℃ UL 746 or UL 94 UL

26AWG 300V
Internal wire Various Various UL 758 UL
80℃
CHI MEI
Plastic enclosure PA-765A(+) 94V-0, 80C UL 94 UL E56070
CORPORATION
Test with
Motor SANLY SF4010SL DC5V 0.3A EN 60335-1
appliance
HUNAN JIAYEDA
Ultrasonic Test with
ELECTRONOC JYD 1.7MHz EN 60335-1
transducer appliance
CO.,LTD
LED lens Formosa Chemicals & ANC100 1.5 mm thick, UL 94, UL 746 UL
Fibre 60.0°C E162823
Corporation.TAIRILAC® V-0
LED Shenzhen Ruicun RC-0807 Vf:4.5V max IEC TR 62778 Tested with
Technology Co. LTD If:0.2mA max appliance
Report No.: AGC08009200601ES02
Page 31 of 82

ANNEX 2 TABLE: Thermal tests of Section 12 P

Type reference ........................................................ : MO9406 


Lamp used .............................................................. : With integrated LED module 
Lamp control gear used .......................................... : N/A 
Mounting position of luminaire ................................ : As in manual 
Supply wattage (W) ................................................ : 
Supply current (A) ................................................... : 
Temperatures in test 1 - 4 below are corrected for 
ta (C) ..................................................................... :
- abnormal operating mode..................................... : 
- test 1: rated voltage ............................................. : 
- test 2: 1,06 times rated voltage or 1,05 times rated 5.3Vdc 
wattage or 1,1 times constant voltage/current ....... :
- test 3: Load on wiring to socket-outlet, 1,06 times 
voltage or 1,05 times wattage ................................. :
Through wiring or looping-in wiring loaded by a 
current of A during the test .................................... :
- test 4: 1,1 times rated voltage or 1,05 times rated 
wattage or 1,1 times constant voltage/current ........ :

Temperature measurements (C)

Cl. 12.4 – normal Cl. 12.5 – abnormal


Part Ambient
test 1 test 2 test 3 limit test 4 limit
PCB near U1 25 - 54 - 130 - -
L1 25 - 76.3 - 130 - -
C2 25 - 59.2 - 105 - -
Plastic enclosure inside near L1 25 - 60.8 - 80 - -
Plastic enclosure outside near 25 - 38.5 - - -
80
L1
Internal wire 25 - 56.4 - 80 - -
Plastic enclosure inside near 25 - 42.2 - - -
80
atomizer
Plastic enclosure outside near 25 - 35.7 - - -
80
atomizer
Touch switch 25 - 34.4 75 - -
Bottom shell 25 - 26.8 - 75 - -
LED PCB 25 - 58.7 - 130 - -
LED lens 25 31.1 60
Report No.: AGC08009200601ES02
Page 32 of 82

Mountain surface 25 26.7 90


Supplementary information:
Report No.: AGC08009200601ES02
Page 33 of 82

ANNEX 3 Screw terminals (part of the luminaire) N

(14) SCREW TERMINALS N


(14.2) Type of terminal ........................................................: 
Rated current (A) ......................................................: 
(14.3.2.1) One or more conductors N
(14.3.2.2) Special preparation N
(14.3.2.3) Terminal size N
Cross-sectional area (mm²) ......................................: 
(14.3.3) Conductor space (mm) .............................................: N
(14.4) Mechanical tests N
(14.4.1) Minimum distance N
(14.4.2) Cannot slip out N
(14.4.3) Special preparation N
(14.4.4) Nominal diameter of thread (metric ISO thread) ......: N
External wiring N
No soft metal N
(14.4.5) Corrosion N
(14.4.6) Nominal diameter of thread (mm) .............................: N
Torque (Nm) .............................................................: N
(14.4.7) Between metal surfaces N
Lug terminal N
Mantle terminal N
Pull test; pull (N) .......................................................: N
(14.4.8) Without undue damage N

ANNEX 4 Screwless terminals (part of the luminaire) N

(15) SCREWLESS TERMINALS N


(15.2) Type of terminal ........................................................: 
Rated current (A) ......................................................: 
(15.3.1) Material N
(15.3.2) Clamping N
(15.3.3) Stop N
(15.3.4) Unprepared conductors N
Report No.: AGC08009200601ES02
Page 34 of 82

(15.3.5) Pressure on insulating material N


(15.3.6) Clear connection method N
(15.3.7) Clamping independently N
(15.3.8) Fixed in position N
(15.3.10) Conductor size N
Type of conductor N
(15.5) Terminals and connections for internal wiring N
(15.5.1) Mechanical tests N
(15.5.1.1.1) Pull test spring-type terminals (4 N, 4 samples) .......: N
(15.5.1.1.2) Pull test pin or tab terminals (4 N, 4 samples)..........: N
Insertion force not exceeding 50 N N
(15.5.1.2) Permanent connections: pull-off test (20 N) N
(15.5.2) Electrical tests N
Voltage drop (mV) after 1 h (4 samples) ..................: N
Voltage drop of two inseparable joints N
Number of cycles: 
Voltage drop (mV) after 10th alt. 25th cycle N
(4 samples) ...............................................................:
Voltage drop (mV) after 50th alt. 100th cycle N
(4 samples) ...............................................................:
After ageing, voltage drop (mV) after 10th alt. N
25th cycle (4 samples) ..............................................:
After ageing, voltage drop (mV) after 50th alt. N
100th cycle (4 samples)............................................:
(15.6) Terminals and connections for external wiring N
(15.6.1) Conductors N
Terminal size and rating N
15.6.2 Mechanical tests N
(15.6.2.1) Pull test spring-type terminals or welded connections N
(4 samples); pull (N) ................................................:
(15.6.2.2) Pull test pin or tab terminals (4 samples); N
pull (N) .....................................................................:
(15.6.3) Electrical tests N
Tests according 15.6.3.1 + 15.6.3.2 in IEC 60598-1 N

(15.6.3.1) N
TABLE: Contact resistance test / Heating tests
(15.6.3.2)
Voltage drop (mV) after 1 h 
Report No.: AGC08009200601ES02
Page 35 of 82

terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Voltage drop of two inseparable joints
Voltage drop after 10th alt. 25th cycle
Max. allowed voltage drop (mV) ................ : 
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Voltage drop after 50th alt. 100th cycle
Max. allowed voltage drop (mV) ................ : 
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Continued ageing: voltage drop after 10th alt. 25th cycle
Max. allowed voltage drop (mV) ................ : 
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Continued ageing: voltage drop after 50th alt. 100th cycle
Max. allowed voltage drop (mV) ................ : 
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)

Supplementary information:
Report No.: AGC08009200601ES02
Page 36 of 82

ATTACHMENT TO TEST REPORT IEC 60598-2-4


EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Luminaires
Part 2: Particular requirements
Section 4: Portable general purpose luminaires
Differences according to ............... : EN 60598-2-4:2018 used in conjunction with
EN 60598-1:2015+A1:2018
Annex Form No............................... : EU_GD_IEC60598_2_4G
Annex Form Originator .................. : IMQ S.p.A
Master Annex Form ........................ : 2018-07-10
Copyright © 2015 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE),
Geneva, Switzerland. All rights reserved.

CENELEC COMMON MODIFICATIONS (EN) P

4.5 (3) MARKING N


For luminaires not supplied with terminal block:
4.5 (3.3.101) N
Adequate warning on the package

4.6 (4) CONSTRUCTION N


4.6 (4.11.6) Electro-mechanical contact systems N

4.10 (5) EXTERNAL AND INTERNAL WIRING N


4.10 (5.2.1) Connecting leads N
- without a means for connection to the supply N
- terminal block specified N
- relevant information provided N
- compliance with 4.6, 4.7.1, 4.7.2, 4.10.1, 11.2, 12
N
and 13.2 of Part 1
4.10 (5.2.2) Cables equal to EN 50525 N
Replace table 5.1 – Supply cord N

4.12 (12) ENDURANCE TESTS AND THERMAL TESTS P


4.12 (12.4.2c) Thermal test (normal operation)
see footnote c to table 12.2 relating to unsleeved P
fixed wiring
Report No.: AGC08009200601ES02
Page 37 of 82

ZB ANNEX ZB, SPECIAL NATIONAL CONDITIONS (EN) N


DK: power supply cords of class I luminaires
(3.3) N
with label
(4.5.1) DK: socket-outlets N
(5.2.1) CY, DK, FI, GB: type of plug N

ZC ANNEX ZC, NATIONAL DEVIATIONS (EN) N


(4 & 5) FR: Shuttered socket-outlets 10/16A N
FR: Safety requirements for high buildings N

(Arrêté du 30 décembre 2011 portant règlement de sécurité pour la construction des


immeubles de grande hauteur et leur protection contre les risques d’incendie et de
panique; Section VIII; Article GH 48, Eclairage)

Glow-wire test for outer parts of luminaires:


- 850C for luminaires in stairways and horizontal N
travel paths
- 650C for indoor luminaires N
GB: Requirements according to United Kingdom N
(13.3)
Building Regulation
Report No.: AGC08009200601ES02
Page 38 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
4 (4) GENERAL REQUIREMENTS P
- (4) Insulation materials according requirements in (see Annex N) N
Annex N of EN 61347-1
- (4) Compliance of independent controlgear enclosure N
with IEC 60598-1
- (4) Built-in electronic controlgear with double or (see Annex O) N
reinforced insulation comply with Annex O of
EN 61347-1
- (4) SELV controlgear comply with Annex L of EN 61347- (see Annex L) P
1

6 (6 ) CLASSIFICATION P
Independent controlgear.......................................... : No 
Built-in controlgear ................................................... : No 
Integral controlgear .................................................. : Yes 

7 (7) MARKING N
7.1 (7.1) Mandatory markings (other than integral miscellaneous electronic circuits): N
a) mark of origin N
b) model number, type reference ............................ : N
d) correlation between interchangeable parts and N
controlgear marked
e) rated supply voltage (V) ...................................... : N
supply frequency (Hz) N
supply current (A) N
f) earthing symbol N
Information if permitted to use without connection to N
earth
k) wiring diagram N
l) value of tc alternative ta N
7.1 (-) control terminals identified, if applicable N
classification of insulation between live parts and N
control circuits
7.1 (7.2) Marking durable and legible N
Report No.: AGC08009200601ES02
Page 39 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
Rubbing 15s water, 15s petroleum; marking legible N
7.2 (7.1) information to be provided, if applicable N
h) declaration on protection against accidental N
contact
i) cross-section of conductors(mm2) N
j) number, type and wattage of lamp(s) N
- (7.2) Marking durable and legible N
Rubbing 15s water, 15s petroleum; marking legible N

8 (10) PROTECTION AGAINST ACCIDENTAL CONTACT WITH LIVE PARTS N


- (10.1) Controlgear protected against accidental contact N
with live parts
- (A2) Voltage measured with 50 k N
- (A3) Voltage > 35 V peak or > 60 V d.c. or protective N
impendance device
- (10.1) Lacquer or enamel not used for protection or N
insulation
Adequate mechanical strength on parts providing N
protection
- (10.2) Capacitors > 0,5 F: voltage after 1 min (V): < 50 V N
- (10.3) Controlgear providing SELV N
Accessible conductive parts are insulated from live N
parts by double or reinforced insulation in SELV
controlgear
No connection between output circuit and the body N
or protective earthing circuit
No possibility of connection between output circuit N
and the body or protective earthing circuit through
other conductive parts
SELV outputs separated by at least basic insulation N
ELV conductive parts insulated as live parts N
Tests according Annex L of IEC 61347-1 N
10.4 Accessible conductive parts in SELV circuits N
Output voltage under load  25 V r.m.s. or  60 V N
d.c.
Report No.: AGC08009200601ES02
Page 40 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
If output voltage > 25 V r.m.s. or > 60 V d.c.; N
No load output  35 V peak or  60 V d.c and to uch
current does not exceed 0,7 Ma (peak) or 2 Ma d.c.:
One conductive part is insulated if output voltage or N
current exceeding the values above and withstand
test voltage 500 V
Double or reinforced insulation bridged by N
appropriate and at least two resistors or two Y2
capacitors or one Y1 capacitor
Y1 or Y2 capacitors comply with IEC 60384-14 N
Resistors comply with test (a) in 14.1 of N
IEC 60065

9 (8) TERMINALS N
Screw terminals according section 14 of IEC 60598- N
1
Separately approved; component list (see Annex 1) N
Part of the controlgear (see Annex 2) N
Screwless terminals according section 15 of IEC 60598-1: N
Separately approved; component list (see Annex 1) N
Part of the controlgear (see Annex 3) N

10 (9) PROVISION FOR EARTHING N


- (9.1) Provisions for protective earthing N
Terminal complying with clause 8 N
Locked against loosening and not possible to loosen N
by hand
Not possible to loosen clamping means N
unintentionally on screwless terminals
All parts of material minimizing the danger of N
electrolytic corrosion
Made of brass or equivalent material N
Contact surface bare metal N
measured resistance () at  10 A according 7.2.3 N
of IEC 60598-1: < 0,5  .......................................... :
Report No.: AGC08009200601ES02
Page 41 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
- (9.2) Provision for functional earthing N
Comply with clause 8 and 9.1 N
Functional earth insulated from live parts by double N
or reinforced insulation
- (9.3) Lamp controlgear with conductors for protective earthing by tracks on printed circuit N
board
Test with a current of 25 A between earthing terminal N
and each of the accessible metal parts;
measured resistance () at  10 A according 7.2.3
of IEC 60598-1: < 0,5  .......................................... :
- (9.4) Earthing of built-in lamp controlgear N
Earth by means of fixing to earthed metal of N
luminaire in compliance of 7.2 of IEC 60598-1
Earthing terminal only for earthing the built-in N
controlgear
- (9.5) Earthing via independent controlgear N
- (9.5.1) Earth connection to other equipment N
Looping or through connection, conductor min. 1,5 N
mm²and of copper or equivalent
Protective earthing wires in line with 5.3.1.1 and N
clause 7
- (9.5.2) Earthing of the lamp compartments powered via the N
independent lamp controlgear
Test with a current of 25 A between input and output N
earth terminals; measured resistance () between
earthing terminal and each of the accessible metal
parts at  10 A according 7.2.3 of IEC 60598-1:
< 0,5  .................................................................... :
Output earthing terminal marked as in 7.1 t) of IEC N
61347-1

11 (11) MOISTURE RESISTANCE AND INSULATION P


After storage 48h at 91-95% relative humidity and 20-30 °C measuring of insulation P
resistance with d.c. 500V (MΩ):
≥2MΩ for basic insulation ........................................ : >100MΩ P
For double or reinforced insulation  4 M ............. : N
Report No.: AGC08009200601ES02
Page 42 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
Between primary and secondary circuits in N
controlgear providing SELV, values in Annex L in
IEC 61347-1

12 (12) ELECTRIC STRENGTH P


Immediately after clause 11 electric strength test for 1min P
Basic insulation for voltages of SELV, test voltage 500V P
500 V
Working voltage  50 V, test voltage 500 V P
Working voltage > 50 V  1000 V, test voltage (V): N
Basic insulation, 2U + 1000 V N
Supplementary insulation, 2U + 1000 V N
Double or reinforced insulation, 4U + 2000 V N
No flashover or breakdown P
Solid or thin sheet insulation for double or reinforced N
insulation fulfil the requirements in Annex N in IEC
61347-1

14 (14) FAULT CONDITIONS P


- (14.1) When operated under fault conditions the controlgear: P
- does not emit flames or molten material P
- does not produce flammable gases P
- protection against accidental contact not impaired N
Thermally protected controlgears does not exceed N
the marked temperature value
Fault conditions: capacitors, resistors or inductors P
without proof of compliance with relevant
specifications have been short-circuited or
disconnected
- (14.2) Short-circuit of creepage distances and clearances if (see appended table) P
less than specified in clause 16 in Part 1 (after any
reduction in 14.2 - 14.5)
- (14.3) Short-circuit or interruption of semiconductor devices P
- (14.4) Short-circuit across insulation consisting of lacquer, N
enamel or textile
- (14.5) Short-circuit across electrolytic capacitors P
Report No.: AGC08009200601ES02
Page 43 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
- (14.6) After the tests has been carried out on three >100MΩ P
samples:
The insulation resistance  1 M ........................... : P
No flammable gases P
No accessible parts have become live P
During the tests, a five-layer tissue paper, where the P
test specimen is wrapped, does not ignite
- (14.7) Relevant fault condition tests with high-power supply P

15 (15) CONSTRUCTION P
- (15.1) Wood, cotton, silk, paper and similar fibrous material P
Wood, cotton, silk, paper and similar fibrous material P
not used as insulation
- (15.2) Printed circuits P
Printed circuits used as internal connections P
complies with clause 14
- (15.3) Plugs and socket-outlets used in SELV or ELV N
circuits
No dangerous compatibility between output socket- N
outlet and a plug for socket-outlets for input circuit in
relation to installation rules, voltages and
frequencies
Plugs and socket-outlets for SELV comply with IEC N
60906-3 and IEC 60884-2-4
Plugs and socket-outlets for SELV  3 A,  25 V N
r.m.s. or  60 V d.c. and  72 W comply with IEC
60906-3 and IEC 60884-2-4 or:
- plugs not able to enter socket-outlets of other N
standardized system
- socket-outlets not admit plugs of other N
standardized system
- (15.4) Insulation between circuits and accessible parts P
- (15.4.2) SELV circuits P
Source used to supply SELV circuits: P
- safety isolating transformer in accordance with N
relevant part 2 of IEC 61558
Report No.: AGC08009200601ES02
Page 44 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
- controlgear providing SELV in accordance with P
relevant part 2 of IEC 61347
- another source N
Voltage in the circuit not higher than ELV P
SELV circuits insulated from LV by double or N
reinforced insulation
SELV circuits insulated from non SELV circuits by N
double or reinforced insulation
SELV circuits insulated from FELV circuits by N
supplementary insulation
SELV circuits insulated from other SELV circuits by N
basic insulation
SELV circuits insulated from accessible conductive N
parts according Table 6 in 15.4.5
- (15.4.3) FELV circuits N
Source used to supply FELV circuits: N
- separating transformer in accordance with relevant N
part 2 of IEC 61558
- separating controlgear providing basic insulation N
between input and output circuits in accordance with
relevant part 2 of IEC 61347
- another source N
- source in circuits separated by the LV supply by N
basic insulation
Voltage in the circuit not higher than ELV N
FELV circuits insulated from LV supply by at least N
basic insulation
FELV circuits insulated from other FELV circuits if N
functional purpose
FELV circuits insulated from accessible conductive N
parts according Table 6 in 15.4.5
Plugs and socket-outlets for FELV system comply with: N
- plugs not able to enter socket-outlets of other N
voltage systems
- socket-outlets not admit plugs of other voltage N
systems
- socket-outlets have a protective conductor contact N
Report No.: AGC08009200601ES02
Page 45 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
- (15.4.4) Other circuits N
Insulation between circuits other than SELV or FELV N
and accessible conductive parts in according Table 6
in 15.4.5.
- (15.4.5) Insulation between circuits and accessible conductive parts N
Accessible conductive parts insulated from active N
parts of electric circuits by insulating according Table
6
Requirements for Class II construction with equipotential bonding for protection against N
indirect contact with live parts:
- all conductive parts are connected together N
- conductive parts are reliably connected together N
according test of IEC 60598-1 cl. 7.2.3
- conductive parts comply with requirements of N
Annex A in case of insulation fault

16 (16) CREEPAGE DISTANCES AND CLEARANCES P


- (16) Creepage distances and clearances according P
to 16.2 and 16.3
Controlgears providing SELV comply with additional N
requirements in Annex L
Insulating lining of metallic enclosures N
Controlgear protected against pollution comply with Annex P N
- (16.2) Creepage distances N
- (16.2.2) Minimum creepage distances for working voltages N
Creepage distances according to Table 7 (see appended table) N
- (16.2.3) Creepage distances for working voltages with N
frequencies above 30 kHz
Creepage distances according to Table 8 (see appended table) N
- (16.3) Clearances N
- (16.3.2) Clearances for working voltages N
Clearances distances according to Table 9 (see appended table) N
- (16.3.3) Clearances for ignition voltages and working N
voltages with higher frequencies
Clearances distances for basic or supplementary (see appended table) N
insulation according to Table 10
Report No.: AGC08009200601ES02
Page 46 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
Clearances distances for reinforced insulation (see appended table) N
according to Table 11

17 (17 ) SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS P


Screws, current-carrying parts and connections in compliance with EN 60598-1 (clause P
numbers between parentheses refer to EN 60598-1)
(4.11) Electrical connections P
(4.11.1) Contact pressure P
(4.11.2) Screws: P
- self-tapping screws P
- thread-cutting screws N
- at least two self-tapping screws N
(4.11.3) Screw locking: N
- spring washer N
- rivets N
(4.11.4) Material of current-carrying parts Copper alloy P
(4.11.5) No contact to wood No wood used. P
(4.12) Mechanical connections and glands P
(4.12.1) Mechanical stress N
Screws not made of soft metal N
Screws of insulating material No such screws N
Torque test: part; torque (Nm) ................................. : N
Torque test: part; torque (Nm) ................................. : N
(4.12.2) Screw diameter < 3mm screwed into metal No such screws N
(4.12.3) Void N
(4.12.4) Locked connections N
(4.12.5) Screwed glands: force (N) ....................................... : N

18 (18) RESISTANCE TO HEAT, FIRE AND TRACKING P


- (18.1) Parts of insulating material retaining live parts in position, ball-pressure test: P
See clause 4.15 in EN 60598-2-
- part; test temperature (°C) .................................... : P
4
Report No.: AGC08009200601ES02
Page 47 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
- part; test temperature (°C) .................................... : N
- (18.2) Test of printed boards: P
- part tested .............................................................. : See clause 4.15 in EN 60598-2-
P
4
- part tested .............................................................. : N
- (18.3) Glow-wire test (650C): P
- part tested...............................................................: See clause 4.15 in EN 60598-2-4 P
- part tested...............................................................: N
- (18.4) Needle flame test (10 s): P
- part tested .............................................................. : See clause 4.15 in EN 60598-2-
P
4
- part tested .............................................................. : N
- (18.5) Tracking test: N
- part tested .............................................................. : N
- part tested .............................................................. : N

19 (19) RESISTANCE TO CORROSION N


Rust protection: N
- test according 4.18.1 of IEC 60598-1 N
- adequate varnish on the outer surface N

20(-) ANNEXES P
Comply with appropriate annexes of IEC 61347-1 P
Report No.: AGC08009200601ES02
Page 48 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
(A) ANNEX A - TEST TO ESTABLISH WHETHER A CONDUCTIVE PART IS A LIVE P
PART WHICH MAY CAUSE AN ELECTRIC SHOCK
(A.1) Comply with A.2 or A.3 P
(A.2) Voltage  35 V peak or  60 V d.c .......................... : P
(A.3) If voltage > 35 V peak or > 60 V d.c. or protective N
impendance device; touch current does not exceed
0,7 Ma (peak) or 2 Ma d.c. ...................................... :
Comply with Annex G of IEC 60598-1 N

(C) ANNEX C – PARTICULAR REQUIREMENTS FOR ELECTRONIC LAMP N


CONTROLGEAR WITH MEANS OF PROTECTION AGAINST OVERHEATING
(C3) GENERAL REQUIREMENTS N
(C3.1) Thermal protection means integral with the N
convertor, protected against mechanical damage
Renewable only by means of a tool N
If function depending on polarity, for cord-connected N
equipment protection means in both leads
Thermal links comply with IEC 60691 N
Electrical controls comply with IEC 60730-2-3 N
(C3.2) No risk of fire by breaking (clause C7) N
(C5) CLASSIFICATION N
a) automatic resetting type 
b) manual resetting type 

c) non-renewable, non-resetting type 

d) renewable, non-resetting type 

e) other type of thermal protection; description ..... : N

(C6) MARKING N
(C6.1) Symbol for temperature declared thermally protected N
controlgears
(C6.2) Declaration of the type of protection provided N
(C7) LIMITATION OF HEATING N
(C7.1) Preselection test: N
Test sample placed for at least 12 h in an oven N
having temperature (tc – 5) K
Report No.: AGC08009200601ES02
Page 49 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
No operation of the protection device N
(C7.2) Functioning of protection means: N
Normal operation of the sample in a test enclosure N
according to Annex D at an ambient temperature
such that (tc +0; -5) C is obtained
No operation of the protection device N
Introducing of the most onerous test condition N
determined during test of clause 14
Output of windings connected to the mains supply N
short-circuited, and other part of the convertor
operated under normal conditions
Increasing of the current through the windings N
continuously until operation of the protection means
Continuous measuring of the highest surface N
temperature
Controlgears according to C5 a) or C5 e) operated N
until stable conditions are achieved
Automatic-resetting thermal protectors working N
3 times
Controlgears according to C5 b) working 6 times N
Controlgears according to C5 c) and C5) d) working N
once
Highest temperature does not exceed the marked N
value
Any overshoot of 10% over the marked value within N
15 min

(D) ANNEX D – REQUIREMENTS FOR CARRY OUT THE HEATING TESTS OF N


THERMALLY PROTECTED LAMP CONTROLGEAR
Tests in C7 performed in accordance with Annex D, N
if applicable

(F) ANNEX F – DRAUGHT-PROOF ENCLOSURE N


Draught-proof enclosure in accordance with the N
description
Dimensions of the enclosure N
Report No.: AGC08009200601ES02
Page 50 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
(H) ANNEX H - TESTS P
All tests performed in accordance with the advice P
given in Annex H, if applicable

(L) ANNEX I: PARTICULAR ADDITIONAL REQUIREMENTS FOR SELV D.C. OR A.C. N


SUPPLIED ELECTRONIC CONTROLGEAR FOR LED MODULES

(L.3) Classification N
Class I Yes No 

Class II Yes No 

Class III Yes No 

non-inherently short circuit proof controlgear Yes No 

inherently short circuit proof controlgear Yes No 

fail safe controlgear Yes No 

non-short-circuit proof controlgear Yes No 

(L.4) Marking N
Adequate symbols are used N
(L.5) Protection against electric shock N
Comply with 9.2 of IEC 61558-1 N
(L.6) Heating N
No excessive temperatures in normal use N
Value if capacitor tc marked .................................. : 

Winding insulation classified as Class ................... : 

Comply with tests of clause 14 of IEC 61558-1 with N


adjustments
(L.7) Short-circuit and overload protection N
Comply with tests of clause 15 of IEC 61558-1 with N
adjustments
(L.8) Insulation resistance and electric strength N
(L.8.1) Conditioned 48 h between 91 % and 95 % N
(L.8.2) Insulation resistance N
Between input- and output circuits not less than 5 N
M
Report No.: AGC08009200601ES02
Page 51 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
Between metal parts of class II convertors which are N
separated from live parts by basic insulation only
and the body not less than 5 M ........................... :
Between metal foil in contact with the inner and outer N
surfaces of enclosures of insulating material not less
than 2 M .............................................................. :
(L.8.3) Electric strength N
1) Between live parts of input circuits and live parts N
of output circuits ..................................................... :
2) Over basic or supplementary insulation between: N
a) live parts having different polarity ...................... : N
b) live parts and body if intended to be connected to N
protective earth ...................................................... :
c) accessible metal parts and a metal rod of the N
same diameter as the flexible cable or cord .......... :
d) live parts and an intermediate metal part .......... : N
e) intermediate metal parts and the body .............. : N
f) each input circuit and all other input circuits ....... : N
3) Over reinforced insulation between the body and N
live parts ................................................................. :
(L.9) Construction N
(L.9.1) Transformer comply with 19.12 of IEC 61558-1 and N
19 of IEC 61558-2-6
HF transformer comply with 19 of IEC 61558-2-16 N
(L.10) Components N
Protective devices comply with 20.6 – 20.11 of IEC N
61558-1
(L.11) Creepage distances and clearances N
Creepage distances and clearances not less than in Clause 16 N
Distance through insulation according Table L.5 in N
IEC 61347-1
1) Basic distance through insulation N
Required distance (mm) ........................................ : N
Measured (mm) ...................................................... : N
Required distance (mm) ........................................ : N
Measured (mm) ...................................................... : N
Report No.: AGC08009200601ES02
Page 52 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
Supplementary information N
2) Supplementary distance through insulation N
Required distance (mm) ........................................ : N
Measured (mm) ...................................................... : N
Supplementary information N
3) Reinforced distance through insulation N
Required distance (mm) ........................................ : N
Measured (mm) ...................................................... : N

(N) ANNEX N: REQUIREMENTS FOR INSULATION MATERIALS USED FOR DOUBLE N


OR REINFORCED INSULATION
(N.4) General requirements N
(N.4.1) Material comply with IEC 60085 and IEC 60216 N
series
(N.4.2) Solid insulation N
Electric strength test at least 5 Kv or 1,35 x test N
voltage in Table N.1
If not classified according IEC 60085 and IEC 60216 N
series: Electric strength test increased 10 % of 5,5
Kv or 1,5 x test voltage in Table N.1
(N.4.3) Thin sheet insulation N
(N.4.3.1) Thickness and composition of thin sheet insulation N
- Inside the controlgear and not subjected to N
handling or abrasion during the production and
during maintenance
- Non-separated layers: Min. 3 layers and fulfil N
mandrel test of 150N
- Separated layers: Min. 2 layers and each layer fulfil N
mandrel test of 50N
- Separated layers (alternative): Min. 3 layers and N
2/3 of the layers fulfil mandrel test of 100N
(N.4.3.2) Mandrel test (electric strength test during mechanical N
stress)
Electric strength test after mandrel test: N
- Non-separated layers: min. 5 Kv or 1,35 x test N
voltage in Table N.1
Report No.: AGC08009200601ES02
Page 53 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
- 2/3 of min. 3 separated layers: min. 5 Kv or 1,25 x N
test voltage in Table N.1
- one of 2 separated layers: min. 5 Kv or 1,25 x test N
voltage in Table N.1
No flashover or breakdown occurred N

(O) ANNEX O: ADDITIONAL REQUIREMENTS FOR BUILT-IN ELECTRONIC N


CONTROLGEAR WITH DOUBLE OR REINFORCED INSULATION
(O.6) Marking N
Marking according clause 7 (7) See clause 7 N
Special symbol N
Meaning of the special symbol explained in N
catalogue
(O.7) Protection against accidental contact with live parts N
Requirements of clause 8 (10) See clause 8 N
Test finger not possible to make contact with basic N
insulated metal parts
(O.8) Terminals N
Clause 9 (8) See clause 9 N
(O.9) Provision for earthing N
Functional earthing terminals comply with clause 9 of N
part 1
No protective earthing terminal N
(O.10) Moisture resistance and insulation N
Clause 11 (11) See clause 11 N
(O.11) Electric strength N
Clause 12 (12) See clause 12 N
(O.13) Fault conditions N
Clause 14 (14) See clause 14 N
End of test, between live part and accessible metal N
parts or external parts of insulating material in
contact with the supporting surface comply with
dielectric strength test reduced to 35 % of values
according Table 1 in part 1
Report No.: AGC08009200601ES02
Page 54 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
Insulation resistance according to O.10 between live N
part and accessible metal parts or external parts of
insulating material in contact with the supporting
surface not less than 4 M
(O.14) Construction N
Clause 17 (15) See clause 17 N
Accessible metal parts insulated from live parts by N
double or reinforced insulation
Live part insulated from supporting surface in contact N
with external faces by double or reinforced insulation
(O.15) Creepage distances and clearances N
Clause 18 (16) See clause 18 N
Comply with corresponding values for luminaries in N
IEC 60598-1
(O.16) Screws, current-carrying parts and connections N
Clause 19 (17) See clause 19 N
(O.17) Resistance to heat and fire N
Clause 20 (18) See clause 20 N
(O.18) Resistance to corrosion N
Clause 21 (19) See clause 21 N

(P) Creepage distances and clearances and distance through isolation (DTI) for lamp N
controlgear which are protected against pollution by the use of coating or potting
(P.1) General
P.2 applies if creepage distances less than the N
minimum in Table 7 and 8
P.3 applies if clearance less than the minimum in N
Table 9, 10 and 11
(P.2) Creepage distances N

(P.2.2) Minimum creepage distances for working voltages and rated voltages with frequencies N
up to 30 kHz (Table P.1)
Basic or supplementary insulation: N

Required creepage ................................................. : 

Measured ................................................................ : N

Supplementary information 

Reinforced insulation: N
Report No.: AGC08009200601ES02
Page 55 of 82

Attachment A
Test report of EN 61347-2-11
EN 61347-2-11
Clause Requirement – Test Result – Remark Verdict
Required creepage ................................................. : 

Measured ................................................................ : N

Supplementary information 

(P.2.3) Creepage distances for working voltages with frequencies above 30 kHz (Table P.2) N

Voltage Ûout kV ..................................................... : 

Frequency ............................................................... : 

Required distance ................................................... : 

Measured ................................................................ : N

Supplementary information 

(P.2.4) Compliance with the required creepage distances N

(P.2.4.1) Compliance in accordance with 16.3.3 and test N


according P.2.4.2
(P.2.4.3) Electrical tests after conditioning N

(P.2.4.3.1) Insulation resistance and electric strength N


according Clause 11 and 12
(P.3) Distance through isolation N

(P.3.4) Electrical tests after conditioning N

(P.3.4.1) Insulation resistance and electric strength N


according Clause 11 and 12
(P.3.4.2) Impulse voltage dielectrical test N

Basic or supplementary insulation: N

Working/rated voltage ............................................ : 

Impulse voltage....................................................... : N

Supplementary information 

Reinforced insulation: N

Working/rated voltage ............................................ : 

Impulse voltage....................................................... : N

Supplementary information 
Report No.: AGC08009200601ES02
Page 56 of 82

Attachment A
Test report of EN 61347-2-11
14 TABLE: Test of fault conditions P
Component/Part Simulated fault Result Hazard
C2 S-C Product shut down, recoverable,no hazard No
C4 S-C Product shut down, recoverable,no hazard No
U1(Pin 1-Pin5) S-C Normal operation unrecoverable, no hazard No
C3 S-C Normal operation unrecoverable, no hazard No
D1 S-C Normal operation unrecoverable, no hazard No
Q1 S-C Product shut down, recoverable,no hazard No

16 (16) TABLES: Creepage distances and clearances N


Table 7 Minimum creepage distances (mm) for working voltage N
RMS working voltage (V) not exceeding
Distances
50 150 250 500 750 1000
Required basic insulation, PTI 600 0.6 0.8 1.5 3 4 5.5
Measured -- -- -- -- -- --
Required basic insulation, PTI < 600 1,.2 1.6 2.5 5 8 10
Measured L to N -- -- -- -- -- --
Measured between live parts and accessible
-- -- -- -- -- --
metal enclosure
Required supplementary insulation, PTI  600 0.6 0.8 1.5 3 4 5.5
Measured -- -- -- -- -- --
Required supplementary insulation, PTI < 600 0.6 0.8 1.5 3 4 5.5
Measured -- -- -- -- -- --
Required reinforced insulation, PTI  600 -- 1.6 2.6 5.0 7.6 10
Measured -- -- -- -- -- --
Required reinforced insulation, PTI < 600 -- 3.2 5.0 10 16 20
Measured -- -- -- -- -- --
Minimum value of creepage distances for sinusoidal or non-sinusoidal working
Table 8 N
voltages at different frequency ranges; basic or supplementary insulation
Peak value of the working voltage Ûout kV .........: -- 

Frequency ............................................................: -- 

Required distance .................................................: -- 

Measured .............................................................: --
Supplementary information -- 
Report No.: AGC08009200601ES02
Page 57 of 82

Attachment A
Test report of EN 61347-2-11
Table 9 Minimum clearances for working voltages P
RMS working voltage (V) not exceeding 50 150 250 500 750 1000
Clearances with mains supply transients according impulse withstand category II
- Required basic or supplementary insulation 0.2 0.5 1.5 3 5.5 5.5
- Measured L to N -- -- -- -- -- --
- Measured between live parts and
-- -- -- -- -- --
accessible metal enclosure
- Required reinforced insulation 0.4 1.6 3 5.5 8 8
- Measured -- -- -- -- -- --
Clearances without mains supply transients
- Required basic or supplementary insulation 0.2 0.2 0.2 0.2 0.3 0.7
- Measured -- -- -- -- -- --
Required reinforced insulation 0.2 0.2 0.2 0.4 1.0 1.6
- Measured -- -- -- -- -- --
Minimum distances of clearances for sinusoidal or non-sinusoidal voltages;
Table 10 N
inhomogeneous field conditions; basic or supplementary insulation
Voltage Ûout kV ...................................................: -- 

Frequency .............................................................: -- 

Transients or ignition pulse voltage N

Required distance .................................................: -- 

Measured ..............................................................: -- N

Supplementary information -- 

Ignition voltage or working voltage N

Required distance .................................................: -- 

Measured ..............................................................: -- N

Table 11 Minimum distances of clearances for sinusoidal or non-sinusoidal voltages; N


inhomogeneous field conditions; reinforced insulation
Voltage Ûout kV ...................................................: -- 

Frequency .............................................................: -- 

Transients or ignition pulse voltage N

Required clearance ...............................................: -- 

Measured ..............................................................: -- N

Ignition voltage or working voltage N

Required clearance ...............................................: -- 

Measured ..............................................................: -- N
Report No.: AGC08009200601ES02
Page 58 of 82

Attachment A
Test report of EN 61347-2-11

ANNEX 1 Component list P

mark(s) of
object/part No. manufacturer/ trademark type/model technical data Standard(s)
conformity

See annex 1 of EN60598-2-4

Temperature measurements P
Type reference ........................................ : MO9406 
Lamp used............................................... : -- 
Lamp control gear used .......................... : -- 
Mounting position of luminaire ................ : Normal mounting 
Supply wattage (W) ................................. : 
Supply current (A) ................................... : 
Calculated power factor .......................... : --- 
Table: measured temperatures corrected for Ta = 25C: 
- abnormal operating mode: 
- test 1: rated voltage .............................. : -- 
- test 2: 1,06 times rated voltage or 5.3Vdc 
1,05 times rated wattage ......................... :
- test 3: Load on wiring to socket-outlet, -- 
1,06 times voltage or 1,05 times wattage :
- test 4: 1,1 times rated voltage or -- 
1,05 times rated wattage ......................... :
Temperature (C) of part Clause 12.4 – normal Clause 12.5 – abnormal
Test 1 Test 2 Test 3 Limits Test 4 Limit

Supplementary information: See annex 2 of EN60598-2-4

ANNEX 2 Screw terminals (part of the luminaire) N


(14) SCREW TERMINALS N
(14.2) Type of terminal .................................................... : --
Report No.: AGC08009200601ES02
Page 59 of 82

Attachment A
Test report of EN 61347-2-11
Rated current (A) .................................................. : --
(14.3.2.1) One or more conductors N
(14.3.2.2) Special preparation N
(14.3.2.3) Terminal size --
Cross-sectional area (mm²) .................................. : N
(14.3.3) Conductor space (mm²) ........................................ : N
(14.4) Mechanical tests --
(14.4.1) Minimum distance N
(14.4.2) Cannot slip out N
(14.4.3) Special preparation N
(14.4.4) Nominal diameter of thread (metric ISO thread) N
External wiring N
No soft metal N
(14.4.5) Corrosion N
(14.4.6) Nominal diameter of thread (mm) ......................... : N
Torque (Nm).......................................................... : N
(14.4.7) Between metal surfaces N
Lug terminal N
Mantle terminal N
Pull test; pull (N).................................................... : N
(14.4.8) Without undue damage N

ANNEX 3 Screwless terminals (part of the luminaire) N


(15) SCREWLESS TERMINALS N
(15.2) Type of terminal .................................................... : 
Rated current (A) .................................................. : 
(15.3.1) Material N

(15.3.2) Clamping N

(15.3.3) Stop N

(15.3.4) Unprepared conductors N

(15.3.5) Pressure on insulating material N

(15.3.6) Clear connection method N

(15.3.7) Clamping independently N


Report No.: AGC08009200601ES02
Page 60 of 82

Attachment A
Test report of EN 61347-2-11
(15.3.8) Fixed in position N

(15.3.10) Conductor size N

Type of conductor N

(15.5.1) Terminals internal wiring N

(15.5.1.1) Pull test spring-type terminals (4 N, 4 samples) N

(15.5.1.2) Pull test pin or tab terminals (4 N, 4 samples) N

Insertion force not exceeding 50 N N

(15.5.2) Permanent connections: pull-off test (20 N) N

(15.6) Electrical tests N


Voltage drop (mV) after 1 h (4 samples) .............. : N

Voltage drop of two inseparable joints N

Number of cycles .................................................. : 


Voltage drop (mV) after 10th alt. 25th cycle N
(4 samples) ........................................................... :
Voltage drop (mV) after 50th alt. 100th cycle N
(4 samples) ........................................................... :
After ageing, voltage drop (mV) after 10th alt. N
25th cycle (4 samples) .......................................... :
After ageing, voltage drop (mV) after 50th alt. N
100th cycle (4 samples) ........................................ :
(15.7) Terminals external wiring N

Terminal size and rating N

(15.8.1) Pull test spring-type terminals (4 samples); pull N


(N)
Pull test pin or tab terminals (4 samples); pull (N) N

(15.9) Contact resistance test N


Voltage drop (mV) after 1 h N
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Voltage drop of two inseparable joints N
Voltage drop after 10th alt. 25th cycle N
Max. allowed voltage drop (mV) ................. : 
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Voltage drop after 50th alt. 100th cycle N
Report No.: AGC08009200601ES02
Page 61 of 82

Attachment A
Test report of EN 61347-2-11
Max. allowed voltage drop (mV) ................. : 
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Continued ageing: voltage drop after 10th alt. 25th cycle N
Max. allowed voltage drop (mV) ................. : 
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)
Continued ageing: voltage drop after 50th alt. 100th cycle N
Max. allowed voltage drop (mV) ................. : 
terminal 1 2 3 4 5 6 7 8 9 10
voltage drop (mV)

(15.6.3.1) N
TABLE: Contact resistance test / Heating tests
(15.6.3.2)
Voltage drop (mV) after 1 h 
terminal 1 2 3 4 5 6 7 8 9 10

voltage drop (mV)


Voltage drop of two inseparable joints
Voltage drop after 10th alt. 25th cycle
Max. allowed voltage drop (mV) ................ : 
terminal 1 2 3 4 5 6 7 8 9 10

voltage drop (mV)


Voltage drop after 50th alt. 100th cycle
Max. allowed voltage drop (mV) ................ : 
terminal 1 2 3 4 5 6 7 8 9 10

voltage drop (mV)


Continued ageing: voltage drop after 10th alt. 25th cycle
Max. allowed voltage drop (mV) ................ : 

terminal 1 2 3 4 5 6 7 8 9 10

voltage drop (mV)


Continued ageing: voltage drop after 50th alt. 100th cycle
Max. allowed voltage drop (mV) ................ : 
terminal 1 2 3 4 5 6 7 8 9 10

voltage drop (mV)


Report No.: AGC08009200601ES02
Page 62 of 82

Attachment B
Test report of EN 62031
EN 62031
Clause Requirement − Test Result - Remark Verdict
4 GENERAL REQUIREMENTS P
4.4 Integral modules tested assembled in the luminaire P
4.5 Independent modules complies with requirements in N
IEC 60598-1

5 GENERAL TEST REQUIREMENTS P


5.5 SELV-operated LED modules comply with Annex I of (see Annex 1) N
IEC 61347-2-13
General conditions for tests in Annex A (see Annex A) N

6 CLASSIFICATION P
Built-in module ........................................................: Yes No 
Independent module ...............................................: Yes No 
Integral module .......................................................: Yes No 
For Integral module; Note to 1.2.1 in IEC 60598-1 
applies.

7 MARKING N
7.1 Mandatory markings N
a) mark of origin N
b) model number, type reference N
c)- rated supply voltage (V) : N
- rated supply current (A) : N
- rated input power (W) : N
d) nominal power N
e) indication of connections, wiring diagram N
f) value of tc and place on the module N
g) eye protection N
h) symbol for built-in modules N
i) heat transfer temperature td N
j) power for heat-conduction Pd N
k) working voltage for insulation N
Report No.: AGC08009200601ES02
Page 63 of 82

Attachment B
Test report of EN 62031
EN 62031
Clause Requirement − Test Result - Remark Verdict
7.2 Location of marking N
7.3 Durable and legibility of marking N
- marking of a), b), c) and f) legible after test with N
water
- marking of d) to j) inspection of compliance N

8 TERMINALS N
Screw terminals according section 14 of IEC 60598- N
1:
Separately approved; component list (see Annex 2) N
Part of the luminaire (see Annex 3) N
Screwless terminals according section 15 of IEC N
60598-1:
Separately approved; component list (see Annex 2) N
Part of the luminaire (see Annex 4) N
Connectors according IEC 60838-2-2: N
Separately approved; component list (see Annex 2) N

9 (9) PROVISION FOR PROTECTIVE EARTHING N


External metal parts connected to the earth terminal: N
- compliance with 7.2.1 in AS/NZS 60598-1 N

Test with a current of 10 A between earthing terminal N


and each of the accessible metal parts; measured
resistance (): < 0,5  ........................................:
Protective earth, symbol N

Terminal complying with clause 8 in Part 1 N

Locked against loosening and not possible to loosen N


by hand
Not possible to loosen clamping means N
unintentionally on screwless terminals
Earthing via means of fixing N

Earthing terminal only used for the earthing of the N


control gear
All parts of material minimizing the danger of N
electrolytic corrosion
Report No.: AGC08009200601ES02
Page 64 of 82

Attachment B
Test report of EN 62031
EN 62031
Clause Requirement − Test Result - Remark Verdict
Made of brass or equivalent material N

Contact surface bare metal N

Conductors by tracks on printed circuit boards: N

- a.c. current of 25 A for 1 min between earthing N


terminal and accessible metal parts
- compliance with clause 7.2.1 in AS/NZS 60598-1 N

10 (10) PROTECTION AGAINST ACCIDENTAL CONTACT WITH LIVE PARTS N


- (10.1) Controlgear protected against accidental contact with live parts N
- (A2) The current flowing between the part concerned and N
earth is measured and does not exceed
0,7 mA (peak) or 2 mA d.c. :
- (A2) For frequencies above 1 kHz, the current does not N
exceed 0,7 mA (peak) multiplied by the value of the
frequency in kilohertz or 70 mA (peak) :
- (A3) The voltage between the part concerned and any N
accessible part is measured and does not exceed 34
V (peak) :
- (10.1) Lacquer or enamel not used for protection or N
insulation
Adequate mechanical strength on parts providing N
protection
- (10.2) Capacitors > 0,5 F: voltage after 1 min (V): < 50 V N
:
- (10.3) Controlgear providing SELV N
Accessible conductive parts are insulated from live N
parts by double or reinforced insulation in SELV
controlgear
No connection between output circuit and the body N
or protective earthing circuit
No possibility of connection between output circuit N
and the body or protective earthing circuit through
other conductive parts
SELV outputs separated by at least basic insulation N
ELV conductive parts insulated as live parts N
Tests according Annex L of IEC 61347-1 N
- (10.4) Accessible conductive parts in SELV circuits N
Report No.: AGC08009200601ES02
Page 65 of 82

Attachment B
Test report of EN 62031
EN 62031
Clause Requirement − Test Result - Remark Verdict
Output voltage under load  25 V r.m.s. or  60 V N
d.c.
If output voltage > 25 V r.m.s. or > 60 V d.c.; N
No load output  35 V peak or  60 V d.c and touch
current does not exceed 0,7 mA (peak)
or 2 mA d.c. :
One conductive part is insulated if output voltage or N
current exceeding the values above and withstand
test voltage 500 V
Double or reinforced insulation bridged by N
appropriate and at least two resistors or two Y2
capacitors or one Y1 capacitor
Y1 or Y2 capacitors comply with IEC 60384-14 N
Resistors comply with test (a) in 14.1 of N
IEC 60065

11 (11) MOISTURE RESISTANCE AND INSULATION P


After storage 48 h at 91-95% relative humidity and 20-30 C measuring of P
insulation resistance with d.c. 500 V (M):
For basic insulation  2 M : P

For double or reinforced insulation 4 M N


Between primary and secondary circuits in N
controlgear providing SELV, values in Annex L in
IEC 61347-1

12 (12) ELECTRIC STRENGTH P


Electric strength in compliance with Clause 12 of AS/NZS 61347-1 P
Immediately after clause 11 electric strength test for 1 min P
Working voltage  50 V, test voltage 500 V 500V P
Working voltage > 50V, test voltage (V): 2U + 1000 N
V ..........................................................................:
Basic insulation, 2U + 1000 V N
Supplementary insulation, 2U + 1000 V N
Double or reinforced insulation, 4U + 2000 V N
No flashover or breakdown P
Report No.: AGC08009200601ES02
Page 66 of 82

Attachment B
Test report of EN 62031
EN 62031
Clause Requirement − Test Result - Remark Verdict
Solid or thin sheet insulation for double or reinforced N
insulation fulfil the requirements in Annex N in IEC
61347-1

13 (14) FAULT CONDITIONS P


- (14) When operated under fault conditions the P
controlgear:
- does not emit flames or molten material P
- does not produce flammable gases P
- protection against accidental contact not impaired P
Thermally protected controlgear does not exceed the N
marked temperature value
Fault conditions: capacitors, resistors or inductors N
without proof of compliance with relevant
specifications have been short-circuited or
disconnected
- (14.1) Short-circuit of creepage distances and clearances if N
less than specified in clause 16 in Part 1 (except
between live parts and accessible metal parts)
Creepage distances on printed boards less than N
specified in clause 16 in Part 1 provided with coating
according to IEC 60664-3
- (14.2) Short-circuit or interruption of semiconductor devices N
- (14.3) Short-circuit across insulation consisting of lacquer, N
enamel or textile
- (14.4) Short-circuit across electrolytic capacitors N
- (14.5) After the tests has been carried out on three N
samples:
The insulation resistance  1 M ...........................: N
No flammable gases N
No accessible parts have become live N
During the tests, a five-layer tissue paper, where the N
test specimen is wrapped, does not ignite
- (14.6) Relevant fault condition tests with high-power supply N
13.2 Overpower condition P
Module withstands overpower condition >15 min. P
Report No.: AGC08009200601ES02
Page 67 of 82

Attachment B
Test report of EN 62031
EN 62031
Clause Requirement − Test Result - Remark Verdict
Module with automatic protective device or power N
limiter, test performed 15 min. at limit.
No fire, smoke or flammable gas is produced P
Molten material does not ignite tissue paper, spread N
below the module

15 CONSTRUCTION P
Wood, cotton, silk, paper and similar fibrous material P
not used as insulation

16 (16) CREEPAGE DISTANCES AND CLEARANCES P


Creepage and distances and clearances in compliance with EN 60598-1 P
Class of protection ....................................... : —
Working voltage (V) ..................................... : —
Voltage form ................................................. : Sinusoidal —
Non-sinusoidal
PTI ................................................................ : < 600 > 600 —
Rated pulse voltage (kV) ............................. : - —
(1) Live parts of different polarity: cr (mm); cl (mm) N
....................................................................... :
(2) Live parts and accessible parts: cr (mm); cl (mm) N
....................................................................... :
(3) Parts becoming live: cr (mm); cl (mm) ... : N
(4) Outer surface of cable: cr (mm); cl (mm) : N
(5) Live parts of switches: cr (mm); cl (mm) : N
(6) Live parts and supporting surface: cr (mm); cl N
(mm) ............................................................. :

17 (17) SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS P


Screws, current-carrying parts and connections in compliance with EN 60598-1 P
(clause numbers between parentheses refer to EN 60598-1)
(4.11) Electrical connections: P
(4.11.1) Contact pressure P
(4.11.2) Screws: P

- self-tapping screws P
Report No.: AGC08009200601ES02
Page 68 of 82

Attachment B
Test report of EN 62031
EN 62031
Clause Requirement − Test Result - Remark Verdict
- thread-cutting screws N

- at least two self-tapping screws N


(4.11.3) Screw locking: N

- spring washer N

- rivets N
(4.11.4) Material of current-carrying parts P
(4.11.5) No contact to wood P
(4.12) Mechanical connections and glands: P
(4.12.1) Mechanical stress P

Screws not made of soft metal P

Screws of insulating material N

Torque test: part; torque (Nm) .............................: N

Torque test: part; torque (Nm) .............................: N

Torque test: part; torque (Nm) .............................: N

(4.12.2) Screw diameter < 3 mm screwed into metal N

(4.12.3) Void 

(4.12.4) Locked connections N

(4.12.5) Screwed glands: force (N) ...................................: N

18 (18) RESISTANCE TO HEAT, FIRE AND TRACKING N


Resistance to Heat, Fire and Tracking in compliance with EN 61347-1 (clause N
numbers between parentheses refer to EN 61347-1)
(18.1) Parts of insulating material retaining live parts in position, ball-pressure test: N
- part; test temperature (C) .............................. : N
- part; test temperature (C) .................................. : N
(18.2) Printed boards in accordance with IEC 60249-1, 4.3 N
(18.2.1) Parts of insulating material retaining current-carrying N
parts in position conduct glow-wire test 750 C
(18.2.2) Parts provide protection against electric shock, and N
parts of insulating material retaining SELV parts
in position conduct glow-wire test 650 C
(18.2.3) needle-flame test : N

- flame extinguished within 30 s N


Report No.: AGC08009200601ES02
Page 69 of 82

Attachment B
Test report of EN 62031
EN 62031
Clause Requirement − Test Result - Remark Verdict
- no flaming drops igniting tissue paper N
(18.3) Tracking test N

19 (19) RESISTANCE TO CORROSION N


Resistance to corrosion in compliance with IEC 61347-1 N
Rust protection: N
- test according 4.18.1 of AS/NZS 60598-1 N
- adequate varnish on the outer surface N

20 INFORMATION FOR LUMINAIRE DESIGN N


Information in Annex D (informative) 

21 HEAT MANAGEMENT N
21.1 General N
Exchangeability is safeguarded by cap or base N
21.2 Heat-conducting foil and paste N
Heat-conducting foil delivered with the module if N
necessary

22 PHOTOBIOLOGICAL SAFETY P
22.1 UV radiation N
Luminous radiation not exceed 2mW/klm N
22.2 Blue light hazard RG0 P
Assessed according to IEC TR 62778 P
22.3 Infrared radiation N

13.2 TABLE: Module withstands overpower condition--1.5 times rated Pout P


Test sample Uout Iout Pout Tc(enclosu
re)
MO9406 5.34 233mA 1.244W Lamp
closure:
57.6℃, No
hazards
Report No.: AGC08009200601ES02
Page 70 of 82

Attachment B
Test report of EN 62031
EN 62031
Clause Requirement − Test Result - Remark Verdict
14 TABLE: tests of fault conditions P
Part Simulated fault Hazard
LED S-C, No Hazard; NO
O-C, No Hazard

A ANNEX A - TESTS P
All tests performed in accordance with the P
advisement given in Annex H of IEC 61347-1, if
applicable

B ANNEX 1: SELV-operated LED modules P


ANNEX I of EN 61347-2-13: Approved independent SELV control gear P
I.3 Classification N
I.3.1 Class I Yes No 
Class II Yes No 
I.3.2 a) non-inherently short circuit proof controlgear Yes No 
b) non-inherently open circuit proof controlgear Yes No 
c) inherently short circuit proof controlgear Yes No 
d) inherently open circuit proof controlgear Yes No 
e) fail safe controlgear Yes No 
f) non-short-circuit proof controlgear Yes No 
g) non-open-circuit proof controlgear Yes No 
I.4 Marking N
Adequate symbols are used N
I.5 Protection against electric shock N
I.5.1 No connection between output winding and body N
No connection between output winding and N
protective earthing circuit
I.5.2 Input and output circuits electrically separated from N
each other
I.5.2.1 Insulation between input and output winding of the N
HF-transformer consists of double or reinforced
insulation
Class II: insulation between input/output and body N
consists of double or reinforced insulation
Class I: insulation between input and body consists N
of basic and between output and body
supplementary insulation
Report No.: AGC08009200601ES02
Page 71 of 82

Attachment B
Test report of EN 62031
EN 62031
Clause Requirement − Test Result - Remark Verdict
I.5.2.2 Insulation between input and output winding via the N
core consists of double or reinforced insulation
Insulation between cord and windings of the HD- N
transformer consists of basic insulation
I.5.2.3 Serrated tape, additional layer N
I.5.2.4 Class I controlgear for fixed connection provided with N
basic insulation plus protective screening comply
with the following conditions:
a) Insulation between the input winding and the N
protective screen complies with the requirements for
basic insulation
b) Insulation between the protective screen and the N
output winding complies with the requirements for
basic insulation
c) Metal screen consists of a metal foil or of a N
wire wound screen
d) Metal screen so arranged that both edges cannot N
simultaneously touch a magnetic core
e) Metal screen and its lead-out wire have a cross- N
section sufficient to ensure that an overload device
will open the circuit before the screen is destroyed
f) Lead-out wire sufficiently fixed to the metal screen N
I.5.2.5 Last turn of each winding of the transformer retained N
by positive means
Impregnated winding N
Winding held together by means of insulating N
material
I.5.3 Components bridging between input and output N
circuit
I.5.3.1 Used capacitors and resistors comply with 8.2 N
I.5.3.2 Used opto-couplers N
I.6 Heating N
I.6.1 No excessive temperatures in normal use N
Used material classified as Class : 
Stated value of ta : 
I.6.2 Temperature rises (Upri: 1.06 time supply rated voltage) N
Report No.: AGC08009200601ES02
Page 72 of 82

Attachment B
Test report of EN 62031
EN 62031
Clause Requirement − Test Result - Remark Verdict
Determined temperature rises in windings: N
- Primary (K) :
- Limit max (K) :
- Secondary (K) :
- Limit max (K) :
After the test: N
- no connections have worked loose N
- no reduction of creepage distances and clearances N
- no flow of sealing compound N
- no operation of protecting devices N
- electric strength test between input and output N
windings
I.6.3 Cycling test (10 cycles): N
I.6.3.1 - heat run at (K) : N
I.6.3.2 - moisture treatment 48 h N
I.6.3.3 - vibration test 1 h; 1,5 g N
I.6.3.4 After the tests: N
- insulation resistance  2, 4 or 5 M N
- dielectric strength test for 2 min. at 35 % of N
specified value in table I.6
- Current or the ohmic component does not deviates N
by more than 30 %
I.7 Short-circuit and overload protection N
I.7.1 Upri: 1.06 times rated voltage or 0.94 and 1.06 times N
rated supply voltage (V) :
I.7.2 Determined temperature rise in windings and on other parts: N
I.7.3
I.7.4
- test according to Clause : N
- Primary winding (K) : N
- Limit max (K) : N
- Secondary winding (K) : N
- Limit max (K) : N
- External enclosure < 80 (K) : N
- Rubber insulation of wiring < 60 (K) : N
- PVC insulation of wiring < 60 (K) : N
- Supports < 80 (K) : N
I.7.5 Fail-safe convertors N
Report No.: AGC08009200601ES02
Page 73 of 82

Attachment B
Test report of EN 62031
EN 62031
Clause Requirement − Test Result - Remark Verdict
I.7.5.1 - Upri: 1.06 times rated supply voltage V: 
- Isec: 1.5 times rated output current A: 
- time until steady-state conditions t1 (h) : 
- time until failure t2 (h): < t1; < 5 h : N
I.7.5.2 During the test: N
- no flames, molten material, etc. N
- temperature rise of enclosure < 150 K N
- temperature rise of plywood support < 100 K N
After the test: N
- electric strength (test voltage; 35 % of specified N
value); no flashover or breakdown for primary-to-
secondary and for primary-to-body
- live parts not accessible by test finger through N
holes of enclosure
I.8 Insulation resistance and electric strength N
I.8.1 Conditioned 48 h between 91 % and 95 % N
I.8.2 Adequate insulation (500 V d.c. for 1 min) between: N
Live parts and the body -for basic insulation not less N
than 2 M :
Live parts and the body -for reinforced insulation not N
less than 4 M :
Input- and output circuits not less than 5 M : N
Metal parts of class II convertors which are N
separated from live parts by basic insulation only
and the body not less than 5 M :
Metal foil in contact with the inner and outer surfaces N
of enclosures of insulating material not less than 2
M :
I.8.3 Electric strength test: N
1) Between live parts of input circuits and live parts N
of output circuits :
2) Over basic or supplementary insulation between: N
a) live parts which are or may become of different N
polarity :
b) live parts and body if intended to be connected to N
protective earth :
c) accessible metal parts and a metal rod of the N
same diameter as the flexible cable or cord :
d) live parts and an intermediate metal part : N
Report No.: AGC08009200601ES02
Page 74 of 82

Attachment B
Test report of EN 62031
EN 62031
Clause Requirement − Test Result - Remark Verdict
e) intermediate metal parts and the body : N
3) Over reinforced insulation between the body and N
live parts :
No flashover or breakdown occurred N
I.9 Construction N
I.9.1 Comply with all requirements N
I.9.2 The distance between input and output terminals N
shall not be less than 25 mm :
I.10 Components N
I.10.1 Socket-outlets in the output circuit does not accept N
plugs complying with IEC 60083 and IEC 60906-1
I.10.2 Self-resetting protective devices shall not be used N
unless it is certain that there will be no hazards
Compliance is checked by connecting the convertor N
for 48 h at 1.06 times the rated voltage with the
output short-circuited
I.11 Creepage distances and clearances N
1. Insulation between input and output circuits: N
a) measured values > specified values (mm) : N
b) measured values > specified values (mm) : N
c) measured values > specified values (mm) : N
2. Insulation between adjacent input circuits: N
measured values > specified values (mm) :
2. Insulation between adjacent output circuits: N
measured values > specified values (mm) :
3. Insulation between terminals for external connection: N
a) measured values > specified values (mm) : N
b) measured values > specified values (mm) : N
c) measured values > specified values (mm) : N
4. Basic or supplementary insulation: N
a) measured values > specified values (mm) : N
b) measured values > specified values (mm) : N
c) measured values > specified values (mm) : N
5. Reinforced insulation: measured values > N
specified values (mm) :
6. Distance through insulation: N
a) measured values > specified values (mm) : N
b) measured values > specified values (mm) : N
Report No.: AGC08009200601ES02
Page 75 of 82

Attachment B
Test report of EN 62031
EN 62031
Clause Requirement − Test Result - Remark Verdict
c) measured values > specified values (mm) : N
d) measured values > specified values (mm) : N
Report No.: AGC08009200601ES02
Page 76 of 82

Attachment C
Test report of IEC TR 62778
IEC TR 62778
Clause Requirement  Test Result Verdict
7 MEASUREMENT INFORMATION FLOW P
7.1 Basic flow P
‘Law of conservation of luminance’ applied N
Use of only true luminance/radiance values P
In case of luminaire:
The light source is operated in the luminaire
N
under similar conditions as when tested as a
component
In case Ethr value for RG2 was established the
peak value was derived from angular light N
distribution
7.2 Conditions for the radiance measurement P

Standard condition applied P


(200mm distance, 0,011rad field of view)
Non-standard condition applied N
7.3 Special cases (I): Replacement by a lamp or LED module of another type N
Light source is a white light source N
Evaluation done based on highest luminance N
Evaluation done based on CCT value N
7.4 Special cases (II): Arrays and clusters of primary light sources N
LED package is evaluated as ................................... : RG0 unlimited N
RG1 unlimited
Ethr of LED package applies to array N
8 RISK GROUP CLASSIFICATION N
Risk group achieved: P
- .. Risk Group 0 unlimited P
- .. Risk Group 1 unlimited N
- Ethr ......................................................... N
(lx) :
Distance to reach RG1 ........................
(m) :
Report No.: AGC08009200601ES02
Page 77 of 82

Attachment C
Test report of IEC TR 62778
IEC TR 62778
TABLE: Spectroradiometric measurement P
Measurement performed on: LED package
LED module
Lamp
Luminaire
Model number .................................................. : MO9406
Test voltage (V) ................................................ : 5Vdc 
Test current (mA) ............................................. : - 
Test frequency (Hz) ......................................... : - 
Ambient, t (C) .................................................. : 25.8℃ 
Measurement distance.................................... : 20 cm 
... cm
Source size ...................................................... : Non-small 
Small : .... mm
Field of view .................................................... : 100 mrad 
11 mrad
1,7 mrad (for small sources)
Item Symbol Units Result Remark

Blue light hazard radiance LB W/(m2•sr1) 7.519E-01 RG0


Supplementary information:
Report No.: AGC08009200601ES02
Page 78 of 82

Attachment D
Photos of product

Fig.1- Overall view of product

Fig.2- Luminaire view


Report No.: AGC08009200601ES02
Page 79 of 82

Fig.3- Luminaire view

Fig.4- Luminaire view


Report No.: AGC08009200601ES02
Page 80 of 82

Fig.5 – Uncover view

Fig.6 –Uncover view


Report No.: AGC08009200601ES02
Page 81 of 82

Fig.7 – Control PCB view

Fig.8 –Control PCB view


Report No.: AGC08009200601ES02
Page 82 of 82

Fig.9 –LED view

Fig.10 –LED PCB view