Professional Documents
Culture Documents
Applicant Name & Address: HENAN HENGMING NEW ENERGY CO., LTD.
Chemical And Physical Power Supply Industrial Park, Muye District, Xinxiang
City, Henan, China
Product Description: Rechargeable Ni-Cd Industrial Battery
Ratings & Principle 1.2V, 10~1200Ah
Characteristics:
Signature:
Name: Max Jin
Position:General Manager
Date: 2023-06-14
This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and
conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this
Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,
product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This
Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
The product is 1.2V Ni-Cd batteries for industry use purpose. GN300 is one model of GN series. All models
of this series are with similar ratio and component of anode, cathode and electrolyte.
Model list:
6 Dimensions
7 Electrical tests
7.1 General P
Charge and discharge currents for the tests in
accordance with 7.1 to 7.9 inclusive shall be
based on the value of the rated capacity (C5 Ah).
These currents are expressed as multiples of It
A, where It A = C5 Ah/1 h.
7.2 Charging procedure for test purposes P
7.2.1 General P
Prior to charging, the cells shall have been
discharged at 20 °C ± 5 °C, at a constant current
of 0,2 ItA, down to a final voltage of 1,0 V.
Two charging methods are possible, to be
selected by the cell manufacturers, in order to
define their cells characteristics:
– charge based on constant current;
– charge based on constant voltage, with a value
of possible charging current (CCCV).
7.3.1 General P
The following discharge tests shall be carried
out in the sequence given.
All cells shall be tested at 20 °C as well as at
+5 °C and/or –18 °C.
7.3.2 Discharge performance at 20 °C Refer to table 7.3.2 P
7.3.3 Discharge performance at +5 °C Refer to table 7.3.3 P
7.3.4 Discharge performance at –18 °C Refer to table 7.3.4 P
7.3.6 Discharge performance at high temperature Refer to table 7.3.6 P
7.3.5 Discharge performance at low temperature N/A
(optional)
7.3.7 High rate current test Refer to table 7.3.7 P
7.4 Charge retention Refer to table 7.4 P
7.5 Endurance Refer to table 7.5 P
7.6 Charge acceptance at constant voltage Refer to table 7.6 P
7.8 Electrolyte retention test Refer to table 7.8 P
7.9 Storage Refer to table 7.9 P
8 Mechanical tests
Mechanical tests should be designed in relation N/A
to the intended application. This document does
not therefore specify mechanical tests, which
should be the subject of agreement between the
customer and the manufacturer.
9 Physical appearance
Visual inspection shall be performed on cells. P
No cracking, damage or corrosion shall be
apparent. Any deformation shall be within the
tolerances of the dimensions specified in the
manufacturer’s drawings.
Test result:
Model name: Dischar Discharge Discharge Discharge No. Result Requirement:
ge time Current with Current Current with Sample
1,00V EOD with 1,10V 1,14V EOD
EOD
GN300 1hr 195.0A 138.0A 114.0A 10 cells P Discharge
3hr 93.0A 81.0A 75.0A 10 cells P with
constant
5hr 60.0 57.0A 54.0A 10 cells P current in
8hr 37.8A 37.5A 35.4A 10 cells P 20oC
Test result:
Model name: Sample No: Discharge duration Requirement:
GN300 11# 4.67 h Discharge current: 0.2It
12# 4.92 h (60A);
Discharge duration ≥ 4h
13# 4.93 h 15min (255 min)
14# 4.92 h
15# 4.79 h
Test result:
Model name: Sample No: Discharge duration Requirement:
GN300 11# 3.95 h Discharge current: 0.2It
12# 3.75 h (60A);
Discharge duration ≥ 2h
13# 3.47 h 30min (150 min)
14# 3.65 h
15# 4.04 h
Note: One battery doesn’t meet requirement is permitted by standard. Total 2 failed samples were allowed
for all tests.
Test result:
Model name: Sample No: Discharge duration Requirement:
GN300 11# 5.26 h Discharge current: 0.2It
(30℃) 12# 5.48 h (60A);
Discharge duration ≥ 5h
13# 5.41 h (300 min)
14# 5.50 h
15# 5.47 h
GN300 11# 5.07 h Discharge current: 0.2It
(35℃) 12# 5.30 h (60A);
Discharge duration ≥ 5h
13# 5.23 h (300 min)
14# 5.31 h
15# 5.27 h
GN300 11# 5.09 h Discharge current: 0.2It
(40℃) 12# 5.34 h (60A);
Discharge duration ≥ 5h
13# 5.26 h (300 min)
14# 5.36 h
15# 5.30 h
Note: One battery doesn’t meet requirement is permitted by standard. Total 2 failed samples were allowed
for all tests.
Test result:
Model name: Sample No: Discharge condition Result Requirement:
GN300 11# 600A, 5s Meet requirement No fusing, no
deformation of cell case,
12# 600A, 5s Meet requirement no deformation of
internal cell components
13# 600A, 5s Meet requirement shall be observed. In
14# 600A, 5s Meet requirement addition, the cell voltage
during the discharge
15# 600A, 5s Meet requirement should show no
discontinuity.
Test result:
Model name: Sample No: Discharge duration Requirement:
GN300 1# 4.80 h Discharge current: 0.2It
(60A);
2# 4.71 h Discharge duration ≥ 4h
3# 4.78 h (240 min)
4# 4.90 h
5# 4.77 h
Cycles 1 to 50 shall be repeated until the discharge duration on any 50th cycle becomes less than 3 h 30
min. At this stage, a further cycle shall be carried out in accordance with 7.3.2 at a rate of 0,2 It A.
The endurance test is considered complete when two such successive cycles give a Discharge duration less
than 3 h 30 min.
Test result:
Model name: Sample No: Discharge duration after 500 cycles Requirement:
GN300 6# 4.25 h The number of cycles
obtained when the test
7# 4.18 h is completed shall be
8# 4.08 h not less than 800.
Discharge duration after
9# 4.31 h 800 cycles ≥ 210 min.
10# 3.93 h
Note: 0.25ItA=75A/ 80A, 0.2ItA=60A/ 65A
The charging current shall be limited to R It A and the ambient temperature shall be 20 °C ± 5 °C. The
duration of the charge shall be as described in Table 13.
After charging, the cell shall be stored, in an ambient temperature of 20 °C ± 5 °C, for not less than 1 h and
not more than 4 h. It shall then be discharged under the conditions specified in 7.3.2 at a rate of 0,2 It A.
The duration of discharge shall be not less than 4 h.
Test result:
Model name: Sample No: Discharge duration Requirement:
GN300 1# 4.08 h Discharge current: 0.2It
(60A);
2# 4.05 h Discharge duration ≥ 4h
3# 4.05 h (240 min)
4# 4.08 h
5# 4.05 h
Note: One battery doesn’t meet requirement is permitted by standard. Total 2 failed samples were allowed
for all tests.
Test result:
Model name: Sample No: Discharge duration Requirement:
GN300 16# 5.69 h Discharge current: 0.2It
(60A);
17# 5.53 h Discharge duration ≥ 5h
18# 5.77 h (300 min)
19# 5.57 h
20# 5.69 h
Photos: