Technical specifications V304

X-rail
Power per servo drive 2,6 kW
2
Acceleration 1.000 mm/s

Plasma cutting unit Hifocus360i


Min. thickness 3 mm
Max. thickness 80 mm
Max. pierce capacity 50 mm
Dross-free cutting max. 40 mm
Automatic height setting Yes
Marking lines Yes, with same consumables
2
Plasma gas mild steel Cutting O (99,9% pure clean, dry, oil-free)
Marking Argon gas
2
Shield gas mild steel O / air ( 99,9% pure clean, dry, oil-free )
Automatic gas console Yes
Cutting speed mild steel 6 mm Approx. 4.100 mm / min 130A
12 mm Approx. 3.200 mm / min 200A
25 mm Approx. 2.000 mm / min 360A
40 mm Approx. 1.000 mm / min 360A
50 mm Approx. 700 mm / min 360A
60 mm Approx. 450 mm / min 360A
80 mm Approx. 120 mm / min 360A
* Grounding max. 6 m of machine: AC power, PE and service
grounds must be connected to all equipment according to local
and national codes.
Plasma 3D bevel unit
2
Max. acceleration Z-axis 2.000 mm/sec
Max. speed Z-axis 200 mm/sec
Bevel angle + / - 45°
Positioning accuracy + / - 0,5°
Material thickness 6 - 50 mm

Oxy-fuel triple bevel cutting unit


Type Nozzle mix
Automatic height setting Yes, IHT M4000 CAP
Gas supply Magnetic valve with back-fire protection
Ignition Automatically, external
Bevel angle + / - 45°
Max. thickness 1 pcs 200 mm
bevel cutting 70 mm
Gas Acetylene
Optional gas Propane
2
Cutting gas O
Torch height control
2
Max. acceleration Z-axis 350 mm/sec
Max. speed Z-axis 80 mm/sec

Note
Floor surface must be level and sufficient strong!
Technical details and descriptions are not binding
All mentioned capacities are based on a material strength of 58.000 PSI
Barring changes
Oxy-fuel triple straight cutting unit
Type Nozzle mix
Automatic height setting Yes, IHT M4000 CAP
Gas supply Magnetic valve with back-fire protection
Ignition Automatically, external
Min. / max. strip width 50 – 280 mm
Gas Acetylene
Optional gas Propane
2
Cutting gas O
Torch height control
2
Max. acceleration Z-axis 350 mm/sec
Max. speed Z-axis 80 mm/sec

Oxy-fuel cutting unit


Type Nozzle mix
Automatic height setting Yes, IHT M4000 CAP
Gas supply Magnetic valve with back-fire protection
Ignition Automatically, external
Max. thickness 1 pcs 200 mm
2 pcs 200 mm
3 pcs 125 mm
4 pcs 100 mm
5 pcs 75 mm
6 pcs 60 mm
Gas Acetylene
Optional gas Propane
2
Cutting gas O
Torch height control
2
Max. acceleration Z-axis 350 mm/sec
Max. speed Z-axis 80 mm/sec

General information
Voltage stabilizer Not included
Ambient temperature 0 – 35°C max. 95% relative humidity
Working height 700 mm (+/- 20 mm)

Colour
Plates RAL 3003 Red
Frames RAL 7011 Grey

Note
Floor surface must be level and sufficient strong!
Technical details and descriptions are not binding
All mentioned capacities are based on a material strength of 58.000 PSI