Professional Documents
Culture Documents
General Information
Model Name: A4217-01 /
UBA-10/11-SS SW.Req. No. C20-558-02
EO#4217
SW. Name: UBA-10 (ARG)-SS ID-003 Date: (mm,dd,yyyy) 10.15.2008 Rev: C1
SW. Version: V1.80-19 Note: -
Country (Code): Argentina(ARG) Guide: None
Currency: Peso Check Sum: 1009
Direction: 4-Way Kobetron ID: C3FA
CRC (Seed= 0000): 1455
Denomination: Denomi. Printed Issued MRI#
Years & 2 - '97 ARS2.2A
MRI Ident # 2 - '03 ARS2.2B
5 - '98 ARS5.2A
5 - '03 ARS5.2B
10 - '98 ARS10.2A
10 - - ARS10.2B
20 - '00 ARS20.2A
20 - - ARS20.2B
50 - '99 ARS50.2A
100 - '99 ARS100.2A
100 - - ARS100.2B
Accload Program: V1.19 or newer.
USB Tool Suite: UBA USB Tool Suite Version 1.06 or newer.
Barcode Ticket: Accepts JCM specified barcode tickets.
ICB: ICB feature is enabled or disabled with an ICB Enable / Disable barcode ticket or with the ICB
Enable / Disable Command.
EPROM: 8 Mbit, 100 nano-second data access, or faster. ST Part M27C801-100F1 or equivalent
(UBA-11)
Modifications:
(Version 1.53-16 → 1.80-19) – 01/2009
• Banknote Recognition: Added counterfeit measures for half-fake 50 and 100 Pesos notes.
• Machine Operation: Added anti pullback countermeasures.
• Machine Operation: Supports the UBA USB Tool Suite program. (Able to download and
get performance data using the front USB port).
• Interface: Modified previous countermeasure.
a. Some customers were found to send a Stack command, during a ticket transaction
power recovery sequence, countermeasure was adjusted to allow this extra Stack
command. UBA response is Invalid command immediately upon recovery rather than
communication stop.
• Interface: If a Stack command is sent outside of the normal transaction window, bill
acceptor transmit line will be pulled down to low. Communication from the bill acceptor
will discontinue until power is reset or a reset command is sent.
• Interface: Customer identified a problem when tickets were not accepted even though Host
was sending the correct setup commands. Following a reset command, problem found when
UBA was writing to the ICB, the barcode set function was not being stored into memory.