You are on page 1of 2

Compact Series Oil Temperature

Messko
Order Specification

Compact Series Typ MT-ST160SK(TT) Oil Temperature

Please complete the part number Part. No.: Use for special types only
by selecting the appropriate
parameters: 635 – (– )

e.g.: MT-ST160SK/4U/6m Use for Par. 1 Par. 2 Par. 3 Par. 4 Par. 5 Par. 6
Part. No.: 63510-406 special types
only

Parameter 3
Parameter 1 Parameter 5 XX
Length of capillary tube
Parameter 3
635XX-XXX(-XXXXXX) Y 02 2 m Capillary tube

Parameter 2
Y 04 4 m Capillary tube
Parameter 6
Parameter 4 Y 06 6 m Capillary tube
Y 08 8 m Capillary tube
Y 10 10 m Capillary tube
XX Y 12 12 m Capillary tube
Type
Parameter 1 Y XX Others upon request
Measuring range
Y 01 –20°…+140°C,
PVC protection
Measuring range
–20°…+140°C,
Y 02 PVC protection,
4–20 mA
Analogue output (TT)
Measuring range
Y 10 –20°…+140°C,
Stainless steel protection
Measuring range
–20°…+140°C, Screw joint
G1B
Y 18 Stainless steel protection,
4–20 mA Special types
Analogue output (TT)
XX
Special measuring range
Parameter 4
Measuring range
X Y 05
Microswitches 0°…+160°C
Parameter 2
Thermometer Y XX Others upon request
2 Microswitches pocket
Y 2
(change-over contact)
4 Microswitches XX
4 Special screw joint
(change-over contact) Parameter 5
Y
5 Microswitches Y 07 G3/4˝B
Y 5
(normally open contact) Y 11 M27x2
6 Microswitches Para- 1 2 3 4 Y XX Others upon request
Y 6
(normally open contact) meter red blue green yellow
Y X Others upon request 2 1 and 2
narrow XX
Special switching range
<1K min. 6% min. 6%
m nm nm n standard Parameter 6
6 3 and 4 Y 04 3 and 4 narrow
narrow Y 05 1 and 2/3 and 4 narrow
min. 6% min. 6% <1K
m nm nm n
Y XX Others upon request
6 1 and 2/
3 and 4
<1K min.12 % <1K
m nm nm n narrow TD 20790001
© Messko GmbH 2003 Phone +49 (0)61 71 63 98-0
Gablonzer Straße 25–27 Fax +49 (0)61 71 63 98-98
61440 Oberursel, Germany E-Mail: info@messko.de
Internet: www.messko.de

MT-ST160SK(TT) Technical Data


Housing (standard) Galvanised sheet steel
Mounting ring and housing Acrylic resin coated, bayonet fixing ring with silicone seal
Viewing glass Laminated safety glass with UV filter
Temperature sensor Brass, angled off
Mounting plate Stainless steel
Capillary tube Copper capillary tube with a PVC or stainless steel protection
Cable gland 4 used M25 x 1,5 made of brass and nickel-plated
Sensor screw joint Thread G1B equivalent to BSP1”, brass metallic bright
Characteristics
Measuring range –20...140° C
Tolerance Category 1 according to DIN EN 13190
Site of installation Indoors and outdoors, tropicalised
Ambient temperature –50...80° C
Degree of protection IP55 according to DIN VDE 0470-1
Ventilation The ventilation system provided keeps the glass free of condensation up to a a level of 80 % rel. air humidity
Maximum pointer All thermometers are equipped with a resettable red coloured maximum pointer
Weight Approx. 2,5 kg for a 6 m capillary tube
Analouge output (optional) 4...20 mA (a supply voltage is required)
Microswitches
Quantity 1…6 adjustable microswitches (1…4 change-over microswitches)
Contact load AC: 250 V, / 5 A / cos f = 1
DC: 250 V / 0,4 A (non-inductive)
110 V/0,6 A, 60 V/1 A, 24 V/4 A (non-inductive)
Minimum switching displacement 6 % of the measuring range
Contact material Silver cadmium oxide (AgCdO10)
Rated insulation voltage AC: 2.500 V / 1min.
Switching hysteresis approx. 5°C
Terminals min. 0,25 mm2 / max. 2,5 mm2

TD 20790001 Art.-Nr. 990974