ELFOSPACE OUT-V e OUT-H 3÷31

Water terminal unit


Cased vertical and horizontal indoor installation
Capacity from 1,5 to 9 kW ELFOSPACE

ELFOSpace OUT is the cased water terminal for use in the commercial
OUT-H sector.
HYDRONIC

Muted lines that blend in with any decor.


The available controls are simple and user-friendly, satisfying the most varied of
requirements, with top-of-the-range electronic control designed for connection
to the ELFOControl or general supervisors.
Low noise operation and easy to clean.
These are the concepts behind the development of ELFOSpace, the last
generation room terminal unit that is ideal for any installation.
OUT-V Ten sizes available with an almost countless number of
accessories for resolving any service application requirement.
The ELFOSpace OUT-V series has been designed specifically for cased
vertical installation and the ELFOSpace OUT-H range for cased horizontal
installation.

functions and features

H 2O

Heating-Cooling Indoor inst. Cased vertical inst. Cased horizontal inst. Refrig. Water ELFOControl
(OUT-V) (OUT-H)

available configurations
Necessary configuration strings for supplying the unit with the indicated References for position of fittings:
elements/accessories already mounted on the appliance. - vertical fan coils: right and left defined by standing in front of the appliance;
Certain accessories may also be supplied separately, as indicated in the - horizontal fan coils: right and left defined by standing in the airflow (with the air
“accessories supplied separately” list. blowing on your face).
(1) (2) (3) (4) (5) (6) (7)

ELFOSPACE OUT-H 3 R3 TR - SX - - -
(1) AIR RETURN: 4- Not required (Standard)
4R3 Return from below (Standard) 4KBI2 2-pipe system water balancing kit
4RP Rear return 42V2 2-way on/off valve 2-pipe system
(2) CONTROLS: 43V2 3-way on/off valve 2-pipe system
4TR Fan terminal block (Standard) 410V2 3-way 0-10V valve 2-pipe system
4TRM Terminal block with minimum safety thermostat 4KBI4 4-pipe system water balancing kit (sizes 3,7,11,17,25)
4CTS Clivet.Talk.Terminal Space electronics 42V4 2-way on/off valve 4-pipe system (sizes 3,7,11,17,25)
4CTR Clivet.Talk.Terminal Room electronics 43V4 3-way on/off valve 4-pipe system (sizes 3,7,11,17,25)
(3) WATER COIL / ELECTRIC HEATER: 410V4 3-way 0-10V valve 4-pipe system (sizes 3,7,11,17,25)
4- Not required (Standard) (6) ADDITIONAL TRAY:
4B14T 1-row additional coil for 4-pipe syst. (sizes 3,7,11,17,25) 4- Not required (Standard)
4RE With electric heater 4BRODX With additional tray r.h. water fittings
(4) WATER FITTINGS: 4BROSX With additional tray l.h. water fittings
4SX Left-hand fittings (Standard) (7) SERIAL PORT:
4DX Right-hand fittings 4- Not required (Standard)
(5) VALVES: 4SP1 RS485 remote communication serial port

(1) (2) (3) (4) (5) (6) (7)

ELFOSPACE OUT-V 3 R3 TR - SX - - -
(1) AIR RETURN: (4) WATER FITTINGS:
4R3 Return from below (Standard) 4SX Left-hand fittings (Standard)
4RF Front return 4DX Right-hand fittings
(2) CONTROLS: (5) VALVES:
4TR Fan terminal block (Standard) 4- Not required (Standard)
4TRM Terminal block with minimum safety thermostat 4KBI2 2-pipe system water balancing kit
4HID-F1 3-speed selector + on/off 42V2 2-way on/off valve 2-pipe system
4HID-F2 Bulb thermostat 43V2 3-way on/off valve 2-pipe system
4HID-F3 Bulb thermostat with remote S/W 410V2 3-way 0-10V valve 2-pipe system
4HID-F4 Bulb thermostat with minimum safety thermostat 4KBI4 4-pipe system water balancing kit (sizes 3,7,11,17,25)
4HID-F5 Bulb thermostat with electric heater control 42V4 2-way on/off valve 4-pipe system (sizes 3,7,11,17,25)
4HID-F6 Electronic multifunction room thermostat 43V4 3-way on/off valve 4-pipe system (sizes 3,7,11,17,25)
4CTS Clivet.Talk.Terminal Space electronics 410V4 3-way 0-10V valve 4-pipe system (sizes 3,7,11,17,25)
4CTRD Clivet.Talk.Terminal Room electronics with unit on-board (6) ADDITIONAL TRAY:
display 4- Not required (Standard)
(3) WATER COIL / ELECTRIC HEATER: 4BRV With additional tray
4- Not required (Standard) (7) SERIAL PORT:
4B14T 1-row additional coil for 4-pipe syst. (sizes 3,7,11,17,25) 4- Not required (Standard)
4RE With electric heater 4SP1 RS485 remote communication serial port
accessories

■ 4 HID-E1 3-speed selector + on/off for wall mounting ELFOSpace OUT-V only:
■ 4 HID-E2 Simplified room control E/I+3V+on/off for wall mounting ■ 4 HID-F1 Control mounted on unit: 3 speed selector + off
■ 4 HID-E3 Multi-function room control for wall mounting ■ 4 HID-F2 Control mounted on unit: BULB thermostat (3 speed.+off+E/
■ 4 HID-E4 Multi-function room control for 0-10V valves l+Temp.selection)
■ 4 Minimum hot water temperature thermostat ■ 4 HID-F4 Control mounted on unit: BULB thermostat + minimum
■ 4 Remote air sensor for HID-E2, HID-E3 and HID-E4 thermostat
■ 4 Control device for several units with single room control ■ 4 Additional condensate collecting tray for vertical installation
■ 4 HID-T2 electronic room control ■ 4 Supporting feet with cladding for cased vertical units h=90mm
■ 4 HID-TI2 flush-mounted electronic ambient control ■ 4 Supporting feet with cladding for cased vertical units h=155mm
■ 4 HID-T3 electronic room control with humidity sensor ■ 4 Supporting feet with cladding h=155mm and intake grille for cased
■ 4 RS485 remote communication serial port vertical units

REF-DG11C001GB-00
■ 4 2-pipe water balancing kit = ball valve+balancing valve ■ 4 Rear decor panel for cased vertical units without supporting feet
■ 4 4-pipe water balancing kit = 2 ball valves + 2 balancing valves ■ 4 Rear decor panel for cased vertical units with supporting feet
(sizes 3-7-11-17-25) h=90mm
■ 4 2-way ON/OFF valve kit for 2-pipe systems ■ 4 Rear decor panel for cased vertical units with supporting feet
■ 4 3-way ON/OFF valve kit for 2-pipe systems h=155mm
■ 4 3-way 0-10V valve kit for 2-pipe systems ELFOSpace OUT-H only:
■ 4 Manual fresh air dampe ■ 4 Additional condensate collecting tray for horizontal installation
■ 4 On/off motorized fresh air outlet damper (fittings to right)
■ 4 Additional condensate collecting tray for horizontal installation
(fittings to left)
Key to symbols:

■ Accessories supplied separately.

technical data

Sizes 3 5 7 9 11 15 17 21 25 31
4 Cooling capacity (1) kW 1,51 1,96 2,54 3,03 3,73 4,21 5,49 6,37 7,44 9,03
Sensible cooling capacity (1) kW 1,18 1,43 1,89 2,14 2,71 3,02 4,00 4,49 5,13 6,16
Total input kW 0,05 0,05 0,07 0,07 0,09 0,09 0,12 0,12 0,14 0,14
4 Heating capacity (2) kW 3,65 4,24 5,51 6,08 7,74 8,69 11,5 12,7 14,3 17,1
Air flow rate (max. speed) l/s 97,2 100 120 124 180 185 271 279 398 409
Fan type (3) - CFG
Sound pressure level (min-med-max) (4) dB(A) 34 - 40 - 44 35 - 41 - 46 35 - 42 - 47 38 - 44 - 49 42 - 49 - 54
Power supply V/Ph/Hz 230/1/50
Data referred to the following conditions:

(1) Ambient air temperature: 27°C; 50% R.H. - Temp. water at inlet 7°C, temp. water at outlet 12°C - Max. (3) CFG = centrifugal fan
speed (nominal). (4) Sound pressure in free field at a distance of 1 m. Values calculated from sound power measured in echo
(2) Ambient air temperature: 20°C - Inlet water temperature 70°C, outlet water temperature 60°C - Max. speed chamber to ISO 3741 - ISO 3742
(nominal).

dimensions and clearances

ELFOSpace OUT-H
Sizes 3 5 7 9 11 15 17 21 25 31
Length (A) mm 670 670 870 870 1070 1070 1270 1270 1470 1470
Width (B) mm 220 220 220 220 220 220 220 220 220 220
B leave free Height (C) mm 470 470 470 470 470 470 470 470 470 470
4(A1) mm 20 20 20 20 20 20 20 20 20 20
A2 (A2) mm 20 20 20 20 20 20 20 20 20 20
C1 C (B1) mm 250 250 250 250 250 250 250 250 250 250
A (C1) mm 90 90 90 90 90 90 90 90 90 90
C
A1
Weight in oper. kg 14 14 16 17 23 24 26 28 30 32
C1 The above data refer to standard units.
leave free

A2
A
B
B1 A1
ELFOSpace OUT-V

CAUTION! For trouble-free operation of the unit it is essential to maintain the clearances
in green.

Data contained in this document are not binding and may be changed by the Manufacturer without notice. No part of this publication may be reproduced
www.clivet.com
ELFOSPACE IN-V e IN-H 3÷31

Water terminal unit


Uncased vertical and horizontal indoor installation
Capacity from 1,5 to 9 kW ELFOSPACE
ELFOSpace IN is the uncased water terminal for use in the commercial
sector.
The available controls are designed to satisfy the most varied of requirements,
with top-of-the-range electronic control designed for connection to the
IN-H ELFOControl or general supervisors.
HYDRONIC

Low noise operation and easy to maintain.


These are the concepts behind the development of ELFOSpace, the last
generation room terminal unit that is ideal for any installation.
Ten sizes available with an almost countless number of
accessories for resolving any service application requirement.
The ELFOSpace IN-V series has been designed specifically for uncased
vertical installation and the ELFOSpace IN-H series for uncased horizontal
IN-V installation.

functions and features

H 2O

Heating-Cooling Indoor inst. Uncased vertical Uncased horizontal Refrig. Water ELFOControl
inst. (IN-V) inst. (IN-H)

available configurations
Necessary configuration strings for supplying the unit with the indicated References for position of fittings:
elements/accessories already mounted on the appliance. - vertical fan coils: right and left defined by standing in front of the appliance;
Certain accessories may also be supplied separately, as indicated in the - horizontal fan coils: right and left defined by standing in the airflow (with the air
“accessories supplied separately” list. blowing on your face).
(1) (2) (3) (4) (5) (6) (7)

ELFOSPACE IN-H 3 R3 TR - SX - - -
(1) AIR RETURN: 4KBI2 2-pipe system water balancing kit
4R3 Return from below (Standard) 42V2 2-way on/off valve 2-pipe system
4RP Rear return 43V2 3-way on/off valve 2-pipe system
(2) CONTROLS: 410V2 3-way 0-10V valve 2-pipe system
4TR Fan terminal block (Standard) 4KBI4 4-pipe system water balancing kit (sizes 3,7,11,17,25)
4TRM Terminal block with minimum safety thermostat 42V4 2-way on/off valve 4-pipe system (sizes 3,7,11,17,25)
4CTS Clivet.Talk.Terminal Space electronics 43V4 3-way on/off valve 4-pipe system (sizes 3,7,11,17,25)
4CTR Clivet.Talk.Terminal Room 410V4 3-way 0-10V valve 4-pipe system (sizes 3,7,11,17,25)
(3) WATER COIL / ELECTRIC HEATER: (6) ADDITIONAL TRAY:
4- Not required (Standard) 4- Not required (Standard)
4B14T 1-row additional coil for 4-pipe syst. (sizes 3,7,11,17,25) 4BRODX With additional tray r.h. water fittings
4RE With electric heater 4BROSX With additional tray l.h. water fittings
(4) WATER FITTINGS: (7) SERIAL PORT:
4SX Left-hand fittings (Standard) 4- Not required (Standard)
4DX Right-hand fittings 4SP1 RS485 remote communication serial port
(5) VALVES:
4- Not required (Standard)
(1) (2) (3) (4) (5) (6) (7) (8)

ELFOSPACE IN-V 3 MS R3 TR - SX - - -
(1) AIR SUPPLY: 4RE With electric heater
4MS Standard supply (5) WATER FITTINGS:
4MR 90° supply 4SX Left-hand fittings (Standard)
(2) AIR RETURN: 4DX Right-hand fittings
4R3 Return from below (Standard) (6) VALVES:
4RF Front return 4- Not required (Standard)
(3) CONTROLS: 4KBI2 2-pipe system water balancing kit
4TR Fan terminal block (Standard) 42V2 2-way on/off valve 2-pipe system
4TRM Terminal block with minimum safety thermostat 43V2 3-way on/off valve 2-pipe system
4HID-F1 3-speed selector + on/off 410V2 3-way 0-10V valve 2-pipe system
4HID-F2 Bulb thermostat 4KBI4 4-pipe system water balancing kit (sizes 3,7,11,17,25)
4HID-F3 Bulb thermostat with remote S/W 42V4 2-way on/off valve 4-pipe system (sizes 3,7,11,17,25)
4HID-F4 Bulb thermostat with minimum safety thermostat 43V4 3-way on/off valve 4-pipe system (sizes 3,7,11,17,25)
4HID-F5 Bulb thermostat with electric heater control 410V4 3-way 0-10V valve 4-pipe system (sizes 3,7,11,17,25)
4HID-F6 Electronic multifunction room thermostat (7) ADDITIONAL TRAY:
4CTS Clivet.Talk.Terminal Space electronics 4- Not required (Standard)
4CTR Clivet.Talk.Terminal Room 4BRV With additional tray
(4) WATER COIL / ELECTRIC HEATER: (8) SERIAL PORT:
4- Not required (Standard) 4- Not required (Standard)
4B14T 1-row additional coil for 4-pipe syst. (sizes 3,7,11,17,25) 4SP1 RS485 remote communication serial port
accessories

■ 4 HID-E1 3-speed selector + on/off for wall mounting ■ 4 Air distribution duct with flexible joint
■ 4 HID-E2 Simplified room control E/I+3V+on/off for wall mounting ■ 4 Air return duct with flexible joint
■ 4 HID-E3 Multi-function room control for wall mounting ■ 4 Air supply plenum with round fittings + thermal and acoustic
■ 4 HID-E4 Multi-function room control for 0-10V valves insulating lining
■ 4 Minimum hot water temperature thermostat ■ 4 Air intake plenum with round fittings and air filter
■ 4 Remote air sensor for HID-E2, HID-E3 and HID-E4 ■ 4 Terminal plenum with circular connections
■ 4 Control device for several units with single room control ■ 4 Air supply grille without air filter (suitable for connection to any
■ 4 HID-T2 electronic room control plenum)
■ 4 HID-TI2 flush-mounted electronic ambient control ■ 4 Aluminium air supply grille without air filter
■ 4 HID-T3 electronic room control with humidity sensor ■ 4 Air intake grille with air filter (suitable for connection to any plenum)
■ 4 RS485 remote communication serial port ■ 4 Aluminium air intake grille with air filter

REF-DG11C001GB-00
■ 4 2-pipe water balancing kit = ball valve+balancing valve ELFOSpace IN-V only:
■ 4 2-way ON/OFF valve kit for 2-pipe systems ■ 4 HID-F1 Control mounted on unit: 3 speed selector + off
■ 4 3-way ON/OFF valve kit for 2-pipe systems ■ 4 HID-F2 Control mounted on unit: BULB thermostat (3 speed.+off+E/
■ 4 3-way 0-10V valve kit for 2-pipe systems l+Temp.selection)
■ 4 4-pipe water balancing kit = 2 ball valves + 2 balancing valves ■ 4 HID-F4 Control mounted on unit: BULB thermostat + minimum
(sizes 3-7-11-17-25) thermostat
■ 4 Sub-frame in galvanised sheet metal ■ 4 Additional condensate collecting tray for vertical installation
■ 4 Pre-painted panel with supply and return grilles ■ 4 Supporting feet for uncased vertical units h=90mm
■ 4 Manual fresh air damper for vert. and horiz. installation ■ 4 Supporting feet for uncased vertical units h=155mm
■ 4 Motorized ON/OFF fresh air outlet damper ELFOSpace IN-H only:
■ 4 Straight air supply plenum ■ 4 Additional condensate collecting tray for horizontal installation
■ 4 Straight air intake plenum (fittings to right)
■ 4 90° air supply plenum ■ 4 Additional condensate collecting tray for horizontal installation
■ 4 90° air intake plenum (fittings to left)
■ 4 Telescopic extension 0-100 mm (suitable for connection to any
plenum)

Key to symbols:

■ Accessories supplied separately.

technical data

Sizes 3 5 7 9 11 15 17 21 25 31
4 Cooling capacity (1) kW 1,51 1,96 2,54 3,03 3,73 4,21 5,49 6,37 7,44 9,03
Sensible cooling capacity (1) kW 1,18 1,43 1,89 2,14 2,71 3,02 4,00 4,49 5,13 6,16
Total input kW 0,045 0,045 0,065 0,065 0,085 0,085 0,12 0,12 0,14 0,140
4 Heating capacity (2) kW 1,78 2,09 2,72 3,01 3,83 4,29 5,67 6,29 7,08 8,47
Air flow rate (max. speed) (3) l/s 97,2 100 120 124 180 185 271 279 398 409
Max. working static pressure (4) Pa 40 40 40 40 60 60 60 60 60 60
Fan type (5) - CFG
Sound pressure level (min-med-max) (6) dB(A) 34 - 40 - 44 35 - 41 - 46 35 - 42 - 47 38 - 44 - 49 42 - 49 - 54
Power supply V/Ph/Hz 230/1/50
Data referred to the following conditions:

(1) Ambient air temperature: 27°C; 50% R.H. - Temp. water at inlet 7°C, temp. water at outlet 12°C - Max. (4) Working static pressure at fan maximum speed
speed (nominal). (5) CFG = centrifugal fan
(2) Ambient air temperature: 20°C - Inlet water temperature 45°C, outlet water temperature 40°C - Max. speed (6) Sound pressure in free field at a distance of 1 m. Values calculated from sound power measured in echo
(nominal). chamber to ISO 3741 - ISO 3742
(3) Air flow rate at maximum speed with available head of 0 Pa

dimensions and clearances

ELFOSpace IN-H
Sizes 3 5 7 9 11 15 17 21 25 31
IN-V Length (A) mm 450 450 650 650 850 850 1050 1050 1250 1250
IN-H Length (A) mm 545 545 745 745 945 945 1145 1145 1345 1345
B Width (B) mm 215 215 215 215 215 215 215 215 215 215
Height (C) mm 450 450 450 450 450 450 450 450 450 450
A2 C
4(A1) (*)
(A2) (**)
mm
mm
200
100
200
100
200
100
200
100
200
100
200
100
200
100
200
100
200
100
200
100
C1
D (B1) mm 250 250 250 250 250 250 250 250 250 250
C
C1
(C1) mm 90 90 90 90 90 90 90 90 90 90
A1 Weight in oper. kg 14 14 16 17 23 24 26 28 30 32
The above data refer to standard units.

A2
(*) water fittings side
(**) elect. supply side
A
B
B1 A1
ELFOSpace IN-V

CAUTION! For trouble-free operation of the unit it is essential to maintain the clearances
in green.

Data contained in this document are not binding and may be changed by the Manufacturer without notice. No part of this publication may be reproduced
www.clivet.com