PACKAGE AIR CONDITIONER SCHEDULE LEGEND

A A' B C C' D DATA / DESIGNATION


SERVICE
PAHU-1 / ACCU-1 PAHU-2 / ACCU-2
AS SHOWN LAYOUT PLAN
PAHU-3 / ACCU-3

GENERAL NOTES LOCATION AS SHOWN LAYOUT PLAN


MARK DESCRIPTION
1. AIR CONDITIONED AREA SHALL BE MAINTAINED AT 24°C ± 2°C QUANTITY 1 - UNIT 1 - UNIT 1 - UNIT
AND 55% RH ± 5% RH . SPLIT TYPE FREE BLOW SPLIT TYPE FREE BLOW SPLIT TYPE FREE BLOW
A/C AIR CONDITIONER
2. ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE TYPE
CASSETTE TYPE A/C UNIT CASSETTE TYPE A/C UNIT CASSETTE TYPE A/C UNIT
NOTED.
N
3. ALL EQUIPMENT SHALL BE PROVIDED WITH VIBRATION TOTAL KCALH / TR 15,000 (5TR) 15,000 (5TR) 15,000 (5TR) ACCU AIR COOLED CONDENSING UNIT

NORTH ISOLATORS. SENSIBLE KCALH 10,500 10,500 10,500


4. ALL TOILET DOORS SHALL BE PROVIDED WITH LOUVERS. INDOOR UNIT PAHU-1 PAHU-1 PAHU-1 PAHU PACKAGE AIR HANDLING UNIT
5. PIPE ALL EQUIPMENT DRAIN TO THE NEAREST FLOOR DRAIN
5 PROVIDED BY PLUMBING CONTRACTOR.
SUPPLY AIR L/S 944 944 944

6. WORKMANSHIP : THE WORK THROUGHOUT SHALL BE EXECUTED FACE VEL M/S 2.54 2.54 2.54 F FAN
AIR WELL IN THE BEST & MOST THOROUGH MANNER KNOWN TO TRADE &
FIRE EXIT FILTER 50MM THK. WASHABLE 50MM THK. WASHABLE 50MM THK. WASHABLE
TO THE SATISFACTION OF THE ARCHITECT AND THE ENGINEER.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL
FAN TYPE CENTRIFUGAL CENTRIFUGAL CENTRIFUGAL T THERMOSTAT
DRIVE V-BELT V-BELT V-BELT
GOVERNMENT / LOCAL CONSTRUCTION AND OPERATION
PERMITS AND PAY ALL THE THE REQUIRED FEES, AND REQUIRED ESP MM H20 6 6 6
CIRCUIT BREAKER
TO PROVIDE THE AS-BUILT PLANS. MOTOR TYPE ODP ODP ODP
STORAGE
2000 li 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL THE KW 0.75 0.75 0.75
@1.3m dia.
FOUNDATIONS / SUPPORTS OF ALL MECHANICAL EQUIPMENT. MOTOR STARTER
RPM 1750 1750 1750
OUTDOOR UNIT ACCU - 1 ACCU - 1 ACCU - 1
4 FAN TYPE PROPELLER PROPELLER PROPELLER
ELECTRICAL PANEL (BY OTHERS)
DRIVE DIRECT DIRECT DIRECT
SUPPLY OR FRESH AIR FLOW
ESP MM H2O 6 6 6
DIRECTION
MOTOR TYPE TEFC TEFC TEFC
WI PLA ER W UN

10

EXHAUST OR RETURN AIR FLOW


4" ANF G MO
TH ST
TR ILIN

0m

KW 0.75 0.75 0.75


CE

DIRECTION
4" IC B TH 3 D

RPM 1750 1750 1750


PV LA D

AIR CONDITION UNIT- CASSETTE


PV
C

COMPRESSOR TYPE HERMETIC HERMETIC HERMETIC AC ABOVE


DU DE

5HP

TYPE INVERTER
I

PIP

STEEL TRUSS KW 6.00 6.00 6.00


C TIN

(VERIFY STRUCT'L)
TE

RPM 1750 1750 1750


R
G

FLOOR SLAB REFRIGERANT PIPE


V1

ELECTRICAL DATA
0Z
11

V / Ø / HZ 230 / 1P / 60 230 / 1P / 60 230 / 1P / 60 DRAIN LINE - SEE PLUMBING


3 EXISTING CHB WALL EXISTING CHB WALL

PROPOSED ACCU LOCATION


EGGS HOT
WATER
HOTDOG
STEAMER
SIOPAO
STEAMER
MISTER
DONUT
CITY
BLENDS
REFRIGERANT PIPE REF. PIPE SIZE SIZE SUBJECT TO MANUFACTURER'S STANDARD LAYOUT

ACCU
WIC
REFRIGERANT PIPE
NUT GRAVITY SHUTTER SUCTION MM Ø 29 29 29
INV
AC ABOVE
5HP
EYEBOLTS
GAGE #8 WIRES
LIQUID MM Ø 16 16 16 E ELECTRICAL WIRING
AC
6 DOOR WALK-IN CHILLER

GEN SET
ACCU
ACCU
EXISTING FIREWALL

REFRIGERANT PIPE
(4 PCS.)
REFRIGERANT PIPE
(4 REQUIRED) PIPE DOWN
100mm Ø PVC
COVELIGHT

FS

EXISTING BUILDING APRON


PIPE

T T T
EXISTING
REFRIGERANT PIPE

PIPE UP
SHOWCASE SHOWCASE

STAIRS
EQUIPMENT BASE BOLT & NUT
OPEN

2 BACKWALL
NEOPRENE
PI Ø

VIBRATION L DOOR LOUVER


PE

COVELIGHT
C m

OPEN

ANGULAR PLATFORM
PV 00m

ISOLATOR
OTHER PROPERTY

REFRIGERANT

WIC CEILING LINE


1

EA
IN METAL
PIPE

EXHAUST GRILLE SA SUPPLY AIR

EQUIPMENT BASE BOLT & NUT


E
INV
P
INV
EA EXHAUST AIR
EXISTING FIREWALL

AC ABOVE
PI
AC ABOVE NEOPRENE
5HP
AC VC
5HP
AC CEILING MOUNTED CONCRETE VIBRATION
P

0m
m
Ø 01 EXHAUST FAN DET. SECTION ISOLATOR
CONC. PEDESTAL EAG EXHAUST AIR GRILLE
10 FLOOR MATTING
1520 x 910
M-2 M-2 SCALE NTS
6mm Dep.

1 FIRE EXIT FLOOR MATTING


EAG FAN SWITCH CONTROLLER
OUNTED 1520 x 910

AUST FAN VENT 6mm Dep.


NOTE: VERIFY ACTUAL SITE
ANCHOR BOLT
IN CONCRETE CONDITIONS, ADJUST DETAILS
EXISTING BUILDING APRON
ACCORDINGLY
04 VIBRATION INSULATOR DET.
S I D E W A L K N
M-1 M-1 SCALE AS SHOWN THIS SITE
FAN SCHEDULE
DATA / DESIGNATION F-1 F-2 F-3
01 MECHANICAL LAYOUT PLAN
M-1 M-1 SCALE 1:100 MTS SERVICE TOILET EXHAUST FAN TRANSFER FAN EXHAUST FAN

Dipolog-O
NORTH
LOCATION AS SHOWN ON PLAN AS SHOWN ON PLAN AS SHOWN ON PLAN
City Hall of Dipolog
QUANTITY 1-UNIT 1-UNIT 1-UNIT

roquieta N
City Government of Dipolog
River
CEILING MOUNTED CEILING MOUNTED PROPELLER WALL FAN Dipolog
TYPE
FAN CASSETTE TYPE FAN CASSETTE TYPE INDUSTRIAL TYPE

ational Rd
STEEL TRUSS
(VERIFY STRUCT'L) CAPACITY L / S 47 142 236 Dipolo
g-Oro
FLOOR SLAB q uieta Philippine
Nationa
TSP MM H O 12 12 6 l Rd. Statistics Office
2

.
OUT. VELOCITY M / S - - -
GRAVITY
NUT Dipolo
SHUTTER g-Oro
DRIVE DIRECT DIRECT DIRECT quieta
EYEBOLTS EXHAUST PIPE Nation
al Rd.
GAGE #8 WIRES MOTOR TYPE SEALED SEALED SEALED
(4 PCS.) City Administrator's Office
(4 REQUIRED) WATTS 60 110 90 Dipolog
Rotonda
RPM 1150 1150 1150

V / Ø / Hz 230 / 1 / 60 230 / 1 / 60 230 / 1 / 60 Zamboanga del Norte


EA National Food
CEILING LINE National High School
EXHAUST GRILLE COMPLETE WITH BACKDRAFT COMPLETE WITH BGRAVITY Authority (NFA)
DAMPER & EXHAUST GRILLE. SHUTTER & EXHAUST GRILLE
BREAKER / STARTER REMARKS
PROVIDE INDIVIDUAL SWITCH PROVIDE INDIVIDUAL SWITCH
(ORDINARY LIGHT SWITCH). (ORDINARY LIGHT SWITCH).
CEILING MOUNTED EXHAUST
02 FAN DETAIL SECTION
M-2 M-2 SCALE NTS
03 VICINITY MAP
M-1 M-1 SCALE NTS

PROJECT TITLE : OWNER : SHEET CONTENTS : REPUBLIC ACT 9266, ARTICLE IV, SECTION 33 REVISIONS & NOTES : SHEET NO.
ARCH. PETER PAUL R. DIGAL, PIA
GENERAL NOTES
MECHANICAL E N G I N E E R ARCHITECT PROPOSED INTERIOR RENOVATION
ULYSSES V. BORRAL MECHANICAL LAYOUT PLAN
01
PRC REG. NO.: PRC REG. NO.: 0034159
7-ELEVEN FOOD STORE
PTR NO. : PTR NO. : 7936424 C DATE : 01-06-2023
DIPOLOG CITY HALL
BDD HEAD FAN SCHEDULE M
PHILIPPINE SEVEN CORPORATION
R

DATE :
PLACE :
STORE NO. : 4786
Rizal Avenue corner Gonzales street, Dipolog City, 7th FLOOR THE COLUMBIA TOWER, ORTIGAS AVENUE.,
PACKAGE AIR CONDITIONER SCHEDULE
EXHAUST FAN DETAIL
02
T.I.N. :
DIPOLOG CITY HALL LOCATION : Zamboanga Del Norte ADDRESS : MANDALUYONG CITY
DRAWN BY:
RASMIA CASAN
PROJECT NO.: 012 DATE: 05/26/2023