inductar® ONH cube

The new ONH analyzer is made for fast and precise


analysis of oxygen, nitrogen and hydrogen
in metals and inorganic materials. Extremely
high temperatures of up to 3,000 °C are reached
within the samples by Elementar’s unique solid-
state induction furnace. Together with its high-
performance detectors highly accurate results are
obtained. In addition, maintenance works are
minimized and user convenience maximized for
the new inductar ONH cube.

Simultaneous ONH analysis


Analyzer
Concentration analysis of Oxygen, Nitrogen, Hydrogen 1)
Operating modes ONH, ON, OH (TCD), H (EC) 1)
Design Compact benchtop with single power supply (230 V)
Sample introduction Manual 2 position sample feeder or automated 23 position sample feeder
Furnace design Solid-state induction furnace
Detector type Wide-range NDIR detector for O (CO2),
thermal conductivity detector for N (N2),
electronic hydrogen sensor or thermal conductivity cell for H (H2)
Control Fully digital via external PC
Features Programmable power output (temperature) of induction furnace
Programmable gas split
Gas reduction via sleep mode
Gas injection port
Tool-free maintenance

Sample Introduction
Construction Integrated, auto-aligned sample feeder on top of the analyzer
System Data Sheet

Access Reloadable during operation


Movement control Fully electrical
Automated sample feeder Numbered, non-stacked 23 positions
Customized sample sequence
Different measurement methods for different samples assignable
Sample container Graphite crucibles and nickel capsules/nickel baskets, tin capsules
Syringe injection Manual gas injection via syringe

Furnace
Fusion furnace Programmable, high-performance solid-state induction furnace
Oxidation furnace Vertical, tilting, temperature controlled resistance heater
High temperature reactor Quartz glass tube, internal water cooling
Carrier gas Helium or argon or nitrogen (for H analysis via TCD) 1)
Carrier gas flow 0.5 - 0.75 l/min (depending on measurement mode) 1)
Carrier gas pre-pressure 3.0 bar
Connections Bayonet connector and quick swap clamp connections

1)
depending on chosen instrument configuration
inductar® ONH cube
Detectors / Electronics
Types Wide-range NDIR detector (IR), thermal conductivity detector (TCD),
electronic hydrogen sensor (EHS)
Calibration Single-point or multi-point calibration, calibrations and templates storable
Electronics Fully digital, fully integrated in unit
Security norms CE-mark, EN 61010-1

Software
Operating systems Windows® 10, Windows® 8, Windows® 7, other systems upon request
Features Automatic leak finding software
Intelligent error indicator
Auto sleep and wake-up
Statistical calculations
Automatic monitoring and indication of service cycle
LIMS integration
21 CFR part 11 compliant 2)
Data storage Non manipulated storage of experimental raw data and peak graphics
Balance Automatic data transfer from balance to computer 2)

2)
optional

Technical Specifications
depending on sample type, sample matrix, sample homogeneity and sample mass

Operation modes ONH, ON, OH (TCD), H (EC) 1)


Sample mass Up to 1 g
Required gases Helium or argon (nitrogen for H analysis via TCD): 99.995 % or better
Gas consumption approx. 20 l/analysis
Analysis time 60 – 120 sec.
Cycle time 300 sec.
Autosampler 23 positions
Detection range O: 0 - 20 mg absolute or 0 - 100 %
N: 0 - 30 mg absolute or 0 - 100 %
H: 0 - 40 µg absolute (EHS), 0 - 2 mg absolute (TCD) or 0 - 100 %
Standard deviation O: 0.016 ppm absolute or 1 % RSD whichever is greater
N: 0.15 ppm absolute or 1 % RSD whichever is greater
H: 0.025 ppm absolute or 1 % RSD whichever is greater
Detection limit O: 0.05 ppm
N: 0.2 ppm
H: 0.5 ppm
Weight 95 kg
Dimensions (W x D x H) Manual sampler: 607 mm x 628 mm x 860 mm / Autosampler: 607 mm x 628 mm x
1045 mm
Electrical connections 230 V, 50/60 Hz, 1.1 kWh, 3.3 kW

Elementar Analysensysteme GmbH


06 / 2021 A

Elementar-Straße 1 · 63505 Langenselbold (Germany)


Phone: +49 (0) 6184 9393-0 | info@elementar.com | www.elementar.com