COMPRESSOR TECHNICAL DATA

EMR70HLR

ENGINEERING CODE REFRIGERANT


513400004 R-134a

POWER SUPPLY APPLICATION


115-127 V 60 Hz L/MBP

MOTOR TYPE STANDARD


CSIR ASHRAE

COOLING CAPACITY EFFICIENCY


415 W 2.05 W/W

DATA

GENERAL DATA

Model EMR70HLR

Type Hermetic Reciprocating

Technology ON/OFF

Compressor Application L/MBP

Expansion Device Capillary Tube

Compressor Cooling Fan/127

HP 1/5

Starting Torque LST

Plant BRAZIL

ELECTRICAL DATA

Start Winding Resistance 8.12 Ω at 25°C

Run Winding Resistance 3.61 Ω at 25°C

Locked Rotor Amperage (LRA) 60Hz 24.4 A

Rated Load Amperage (LMBP) at 60 Hz 2.2 A

Rated Load Amperage (HBP) at 60 Hz 2.9 A


MECHANICAL DATA

Displacement 5.75 cm³

Oil Charge 180 ml

Oil Type ESTER

Oil Viscosity ISO10

Weight 7.5 Kg

ELECTRICAL COMPONENTS

Start Capacitor 233-280 μf/111 V

CSR CSIR BOX No

Starting Device Type RELAY

Overload Protection 4TM762NFBZZ-53

EXTERNAL CHARACTERISTICS

Base Plate UNI AMEM

Connector Internal Diameter Shape Material

Suction 6.5 mm STRAIGHT COPPER

Discharge 6.5 mm STRAIGHT COPPER

Process 6.5 mm STRAIGHT COPPER

PERFORMANCE

TESTED CONDITIONS

Tested Refrigerant R-134a

Tested Application MBP

Tested Standard ASHRAE

Tested Cooling Fan

Tested Voltage 127 V

Tested Frequency 60 Hz

Max Refrigerant Charge 250 g

Refrigerant Temperature Dew


RATED POINTS

Condensing Evaporating Power


Cooling Efficiency Gas Flow
Temperature Temperature Consumption Current A
Capacity W W/W Rate kg/h
°C °C W

54.4 -6.7 415 2.05 202 - 9.03

Test Condition: Subcooling 8.3 K, Return Gas 35 ºC. Data are an indication of performance based simulation.

PERFORMANCE CURVE Condensing Temperature 35ºC

Evaporating Power
Cooling Efficiency Gas Flow
Temperature Consumption Current A
Capacity W W/W Rate kg/h
°C W

-35 119 1.35 88 - 2.16

-30 159 1.61 99 - 2.93

-25 213 1.89 113 - 3.92

-20 280 2.19 128 - 5.15

-15 362 2.53 143 - 6.67

-10 460 2.93 157 - 8.50

-5 575 3.39 170 - 10.68

0 709 3.94 180 - 13.24

Test Condition: Subcooling 8.3 K, Return Gas 35 ºC. Data are an indication of performance based simulation.

PERFORMANCE CURVE Condensing Temperature 45ºC

Evaporating Power
Cooling Efficiency Gas Flow
Temperature Consumption Current A
Capacity W W/W Rate kg/h
°C W

-35 100 1.09 92 - 1.98

-30 137 1.32 104 - 2.72

-25 185 1.55 120 - 3.68

-20 245 1.78 138 - 4.88

-15 319 2.04 157 - 6.36

-10 407 2.31 176 - 8.14

-5 511 2.62 195 - 10.26

0 632 2.99 212 - 12.75

Test Condition: Subcooling 8.3 K, Return Gas 35 ºC. Data are an indication of performance based simulation.
PERFORMANCE CURVE Condensing Temperature 55ºC

Evaporating Power
Cooling Efficiency Gas Flow
Temperature Consumption Current A
Capacity W W/W Rate kg/h
°C W

-30 112 1.09 103 - 2.42

-25 155 1.29 120 - 3.35

-20 208 1.48 140 - 4.51

-15 274 1.68 163 - 5.95

-10 352 1.88 187 - 7.68

-5 444 2.11 211 - 9.74

0 552 2.36 234 - 12.16

Test Condition: Subcooling 8.3 K, Return Gas 35 ºC. Data are an indication of performance based simulation.

ENVELOPE

EXTERNAL DIMENSIONS

embraco.com Wed, Nov 22, 23, 05:15:48 +0000 GMT