Model M4-15
Nominal size 15
Component series 2X
Nominal pressure 350 bar (pump side)
Nominal pressure 420 bar (actuator side)
Maximum flow
– Pump side: 300 l/min for central inlet element
200 l/min for lateral inlet element
– Actuator side: 200 l/min with load-holding function
200 l/min with pressure compensator
160 l/min with pressure compensator and load-holding function
Table of contents
Features
System: Pressure relief function
– Load pressure-independent flow control – Load pressure-compensated
• Open center for fixed displacement pump – High repeatability
• Closed center for variable displacement pump – Low hysteresis
– Adjustable via stroke limiter
Type:
– Sandwich plate design Pressure relief function
• Inlet element – Inlet element
• Up to 9 directional valve elements • Pilot operated pressure valves with large nominal width
• Up top 18 directional valve elements with central inlet – Directional valve element / actuator ports
element, thereof max. 6 with servo operation • Compact pressure valves with feed function
• End element – LS pressure limitation
Types of operation • Adjustable as per actuator port
• External pressure setting as per actuator port possible
– Mechanical (hand lever following)
• Electro-proportional as per section
– Hydraulic
– Servohydraulic Areas of application
– Electrohydraulic (on/off, proportional) – Cranes – Drilling equipment
– Electrohydraulic with on-board electronics (EPM2) – Large-scale and telescopic – Truck applications
Flow forklifts – Municipal vehicles
– Rock crushers – Stationary applications
– Load pressure compensated
– Forestry machinery
– High repeatability
– Low hysteresis
– Adjustable via stroke limitation (not available with
mechanical operated sections)
Function
Control block M4-15 Load pressure compensation
The directional valves are proportional valves according to the Pressure changes at the actuators or at the pump are compen-
load-sensing principle. sated by the pressure compensator (3). The flow to the actua-
tor remains constant even if the load varies.
Actuator control
The flow direction and level of flow reaching the actuator ports Flow limitation
(A or B) is determined by the main spool (2). The maximum flow can be set mechanically and individually via
stroke limiter (6).
Pressure reducing valves (9) control the position of the main
spool (2). The level of electric current at the pressure reduc- Pressure relief function
ing valve determines the level of pilot pressure in the spring The LS pressure as per actuator port can be adjusted internally
chambers (8) and therefore also the stroke of the main spool via the LS pressure relief valves (4) or externally via the LS
(P → A; P → B). ports MA, MB.
The pressure difference at the main spool (2), and conse- Pressure relief/anti-cavitation valves (5) protect the actuator
quently the flow to the actuator, is maintained constant via the ports A and B from pressure peaks and against external forces.
pressure compensator (3).
The highest load pressure is signaled to the pump via the LS
line and the integrated shuttle valves (7).
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 3/46
Cross-section
1 Housing 6.1 A side stroke limiter 9.2 Pressure reducing valve
2 Main spool 6.2 B side stroke limiter (pilot control valve “b”)
3 Pressure compensator 7 LS shuttle valve 10 Compression spring
4 LS pressure relief valves 8 Spring chamber 11 Hand lever
5.1 Secondary valve 9.1 Pressure reducing valve 12 A side cover
5.2 Plug screw (pilot control valve “a”) 13 B side cover
A B
"b"
11
T T
6.1
6.2
"a"
X
6.1
Y
P
LSP
MA/B
9.1 12 4 1 3 2 10 8 13
Symbol
Connections: 4 2 6 5.2 5.1
P Pump P X Y LS T
A, B Actuator B
T Tank
X Pilot oil supply
Y Tank, depressurized MA
LS Load-sensing (LS) MB
MA, MB External LS ports A
"b" A B
9
"a" P T
7
3
4/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
Technical data (Please inquire in case the intended use of unit is outside the given values!)
General
Installation position Any
Type of connection SAE connections per SAE J1626
Mass Inlet element: Closed center J kg (lbs.) 6.6 (14.6)
Open center P kg (lbs.) 10.0 (22.0)
Central inlet element: Closed center JZ kg (lbs.) 8.5 (18.7)
Directional valve element Operation
Hydraulic Electrohydraulic with EPM2
kg (lbs.) 7.1 (15.6) 7.5 (16.5) 7.8 (17.2)
Excess weight of handle-operated lever kg (lbs.) 0.6 (1.3)
End element kg (lbs.) 5.8 (12.8)
Hydraulic fluid and ambient temperature range ϑ °C (°F) –20 to +80 (–4 to +176)
Painting Consult factory
Hydraulic
Max. volume flow at port P qV max l/min (GPM) 300 (79.3) with central inlet element
l/min (GPM) 200 (52.8) with lateral inlet element
A, B qV max l/min (GPM) 160 (42.3) with pressure compensator and load-holding function
(model “S“)
l/min (GPM) 200 (52.8) with pressure compensator, without load-holding function
(model “T“)
l/min (GPM) 200 (52.8) without pressure compensator (model “C”)
Nominal pressure pnom bar (PSI) 350 (5100)
Max. operating pressure P pmax bar (PSI) 350 (5100)
at port A, B pmax bar (PSI) 420 (6100)
LS pmax bar (PSI) 330 (4800)
T pmax bar (PSI) 30 (435)
Y pmax bar (PSI) At zero pressure to the tank
Max. pilot pressure at port X pctrl bar (PSI) 35 (500)
a, b pctrl bar (PSI) 35 (500)
Pilot pressure range Hydraulic pctrl bar (PSI) 8.5 to 22.5 (123 to 325)
Electrohydraulic pctrl bar (PSI) 6.5 to 17.2 (94 to 250)
Required control Δp at the Modelss S; C p bar (PSI) 18 (260)
control block Model T p bar (PSI) 25 (360)
Recommended hydraulic pilot control units TH 6 characteristic curve 97, see RE 64552
LS pressure relief function (adjustment ranges) bar (PSI) 50 to 149 (725 to 2160); 150 to 330 (2175 to 4800)
(selected in the factory)
Hydraulic fluid Mineral oil (HL, HLP) according to DIN 51524, other hydraulic fluids,
such as HEES (synthetic esters) according to VDMA 24568 as well
as hydraulic fluids as specified under RE 90221, at request
Viscosity range Hydraulic ν mm2/s (SUS) 10 to 380 (46 to 1760)
Servohydraulc ν mm2/s (SUS) 16 to 200 (74 to 925) 1)
Maximum permitted degree of contamination of the hydraulic Class 20/18/15, for this we recommend a filter with a minimum
fluid cleanliness class according to ISO 4406 (c) retention rate of β10 ≥ 75
Electrical
Electrical pilot control valves FTWE 2 K...; see RE 58007 2)
FTDRE 2 K...; see RE 58032 2)
Recommended amplifiers RA 1-0/10; 1 axis, see RE 95230
(further control options on inquiry) RA 2-1/10; 4 to 6 axes, see RE 95230
Control units RC see RE 95200
On-board electronics (EPM2) Data from page 49; see also RE 64815-B
1) Between 200 and 380 mm /s reduced maximum quantity.
2
2) Plug-in connectors are not included in the scope of suppy and need to be ordered separately, see page 30.
Note! Note!
The technical data were determined with a viscosity of You can find more information on using the hydraulic products
= 32 mm2/s (HLP46: 50 °C). of Bosch Rexroth in our publication “Hydraulic valves for mobile
applications – General information,” RE 64020-B1.
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 5/46
2.4
2.2
B
2.
B
A
2.2
3.
C 2.1 B
B
A
A
1.
2.3
2.5
6/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
2. B
D
2.2
C 2.
B
3.
1.
D C
2.1 A
C
B
A
2.3 3.
2.5
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 7/46
Order details
Inlet End Additional
Short code element Directional valve element element details
1. Spool axis
M4–15 – 2X / V 19 *
2. Spool axis
Number of directional
valves – 1 to 18 1) 3. Spool axis etc.
Closed Open
center center
Lateral =J =P
Central = JZ
Central for M4-12/15 = JK 2)
FKM seals =V
Connections per SAE J1626 or ISO 11926-1 = 19
Note!
Plug-in connectors are not included in the scope of supply and
need to be ordered separately; see page 30.
8/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
Pressure compensator
with pressure compensator, with load-holding function =S
with pressure compensator, without load-holding function =T
without pressure compensator, with load-holding function =C
LS valve
with LS pressure relief valve 1)
= … …
(pressure information in bar, 3-digit) (no Z possible)
Spool symbol
=E =J =Q
=R
= W 3) = Y 3)
Flow in l/min, 3-digit, e.g. 070-070; actuator ports “A” and “B” =…–…
Spool with pressure function T, only in connection with E, J or Q spools 3) =…T…
Secondary valves
H…= Pressure relief/anti-cavitation valve, adjustable
E= Anti-cavitation function
Q= Plug screw (secondary valves can be retrofitted)
Example
M4 – 1234 – 00 / 3M4-12 – 7871
M a1 b1 A1 B1 a2 b2 A2 B2 a3 b3 A3 B3
P P
LS
X X Y
Y
LS
P A P A P A
T B T B T B
M MB MA MB MA T1 LSZ
12/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
P A P A P A
T B T B T B
T
MB MA T MB MA MB MA
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 13/46
Inlet elements
Characteristic curves (measured at ν = 41 mm2/s and ϑ = 50°C)
Open center
Circulation pressure P → T
25
Circulation pressure ppin bar →
20
15
10
M4 15 2X J Q
Short description
For variable displacement pumps up to 200 l/min
M4 15 2X J …
Short description
For variable displacement pumps up to 200 l/min
Pressure informationin bar after J… reqired (3-digit)
Technical data on primary valve according to RE 64642,
characteristic curve D5
M4 15 2X P …
Short description
For fixed displacement pumps up to 200 l/min
Pressure information in bar after P… reqired (3-digit)
Technical data on primary valve according to RE 64642,
characteristic curve D5
14/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
Short description
For variable displacement pumps up to 300 l/min
Flow in l/min →
X
Y
P
LSP
4 2 5 3 1
Main spool actuated
Pressure differential in bar →
1)
The load-holding function is not leak-free.
16/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
Flow in % →
Settings (example)
LS-pressure in bar →
Note!
Please consult Technical Sales.
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 17/46
S ZZ Z J …–… W2 1 – H… H…
Short description
– LS pressure relief valve cannot be retrofitted
– Housing without measuring connections
18/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
Short description
Differentiation between:
1. Type KBPS – electrohydraulically proportional
2. Type MH2DAD and type KBPS
2. Type KKDE – electrohydraulically switchable
3. Porting pattern KBPS and cover plate
4. Housing KBPS and plug
S … L … J …–… H – H… H… KBPSL8BA
S … J … J …–… H – H… H… KBPSL8AA
S … R … J …–… H – H… H… KBPSR8BA
KBPS…BA: KBPS…AA:
S … N … J …–… H – H… H… KBPSR8AA Decreasing characteristic curve Rising characteristic curve
S … K … J …–… H – H… H… MH2DAD+KBPSH8BA
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 19/46
Addition
Falling Rising SO no.
characteristic characteristic
curve curve (Option:
24 V; 0.8 A)
50 bar KBPSC8BA KBPSC8AA
100 bar KBPSF8BA KBPSF8AA
150 bar KBPSH8BA KBPSH8AA
210 bar KBPSL8BA (2) KBPSL8AA (4)
–033
250 bar KBPSN8BA KBPSN8AA
315 bar KBPSP8BA KBPSP8AA
350 bar KBPSR8BA (1) KBPSR8AA (3)
420 bar KBPST8BA KBPST8AA
= Standard product range
Command value in % →
Electrical Standard
Supply voltage V 12 DC 24 DC
Maximum control current mA max. nominal current 1,760 mA max. nominal current 1,200 mA
Coil resistance – Cold value with 20°C Ω 2.3 4.8
– max. hot value Ω 3.65 7.2
Duty cycle % 100 1)
S … K … J …–… H – H… H… KKDER8PA
Electrical Standard
Type of voltage Direct voltage
Supply voltage V 12 DC 24 DC
Voltage tolerance and ambient temperature See characteristic curve RE 18136-08 page 5
Power consumption Ω 22
Duty cycle % See characteristic curve RE 18136-08 page 5
Maximum coil temperature 2)
°C 150
Switching time according to – ON ms ≤ 80
ISO 6403 (solenoid horizontal)
– OFF ms ≤ 150
Maximum switching frequency cy/h 15,000
Protection type acc. to VDE – Version “K4” IP 65 with plug-in connector mounted and locked
0470-1 (DIN EN 60529),
– Version “C4” IP 66 with plug-in connector mounted and locked
DIN 40050-9
IP 69K with Rexroth plug-in connector (material no. R901022127)
– Version “K40” IP 69K with plug-in connector mounted and locked
1)
If use > 2000 m via NN, we recommend consulting the At the electrical connection “K4”, the protective earth
manufacturer. conductor (PE ) must be connected correctly.
2)
Due to the surface temperatures of the solenoid coils, the Euro-
pean standards EN 563 and EN 982 must be adhered to!
Note!
Consumer pressure does not become depressurized!
S … K … J …–… H – H… H… A
Cover plate
S … K … J …–… H – H… H… Q
Plug
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 21/46
Ordering code
Main application Symbol
Flow information in l/min
Application with defined residual opening
Q…–… (A/B → T)
Actuator port unloaded in neutral position
Regeneration function
R…–…
(P, B → A)
140
120
100
80
60
40
20
hydraulic
operation
8 10 12 14 16 18 20 22.5
8.5
digital on-board
electronics (EPM2)
50 100 150 200 250
0 254
Command value in digits (steps) →
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 23/46
Asymmetric spools
Spool Pressure
Flow in l/min
type compensator
150-120 120-080 080-050 050-032 023–014
S 130-100 100-070 070-045 045-028 020–012
E, J, Q 110-085 085-060 060-040 040-025 017–010
C 175-145 145-110 110-080 080-045
T 190-160 160-100 100-065 065-040 028–017
Spool Pressure
Flow in l/min (more on request)
type compensator
W S 065–065
Y S 045-045
R S 130–100
… (10) Notes on spool characteristic curve, page 22.
(1)
Note!
Please consult Technical Sales.
Example: Solution:
• Spool type J → 130 liter spool + 2 washers = 100 l/min
• Pressure compensator S → Set 140 liters via stroke limitation.
• Command value: QActuator = 140 l/min
Pressure
Spool type Flow in l/min
compensator
150–150
E, J, Q S 130–130
110–110
Note!
Position directional valve elements with maximum flow as close
as possible to the inlet element.
24/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 25/46
S …M… J …–… W4 1 – H… H…
Short description
– On/off valves, type FTWE 2 K according to
RE 58007
S …M… J …–… W5 3 – H… H…
Short description
– On/off valves, type FTWE 2 K according to
RE 58007
S …M… J …–… W6 3 – H… H…
Short description
– On/off valves, type FTWE 2 K according to
RE 58007
26/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
S …M… J …–… W7 1 – H… H…
Short description
– On/off valves, type FTWE 2 K according to
RE 58007
S …M… J …–… G4 3 – H… H…
Short description
– On/off valves, type FTWE 2 K according to
RE 58007
Electrical
Type of voltage Direct voltage
Nominal voltage V 12 24
Power consumption at 20 °C W 14.4 14.4
Coil resistance R20 Ω 10 40
Duty cycle % 100
Switching time ton ms ≤ 20
toff ms ≤ 30
Protection class according to – Solenoid IP 69K
DIN 40050-9
– Electric connection C4 IP 69K 1)
K40 IP 69K 1)
Switching frequency Hz 5
1)
Recommended plug-in connector see page 30.
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 27/46
S … M … J …–… W2 1 K H… H…
Short description
– Proportional pressure reducing valve
type FTDRE 2 K according to RE 58032
S …M… J …–… W8 9 – H… H…
Short description
– Proportional pressure reducing valve
type FTDRE 2 K according to RE 58032
S …M… J …–… G2 1 – H… H…
Short description
– Proportional pressure reducing valve
Type FTDRE 2 K according to RE 58032
28/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
Note!
At request only. Rating by Technical Sales.
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 29/46
End
Inlet element
element
30/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
Note!
Plug-in connectors are not included in the scope of supply and
must be ordered separately.
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 31/46
30° = B1, G1 1
0° = L, O 0° = F, H
2
–30° = D1, J1 3
–60° = D, J
–60° = M, P
350 8
300
6
250
200
4
150
100 2
50
0 0
0 40 80 120 160 200 0 40 80 120 160 200
Flow in l/min → Flow in l/min →
Feed valves
Ordering code:
S … M … J …–… W2 1 – E E
Short description
See RE 64642.
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 33/46
End elements
End element with LS unloading
Ordering code:
LA
LAY
Short description
Takes oil from P line, pressure reduced to 35 bar (defi-
nitely adjusted), pressure relief valve set to 45 bar
LZ
Short description
Supply of parallel switched LS signals
34/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
End elements
End element without LS unloading, with pilot oil
supply
Ordering code:
LZY
Short description
Supply of parallel switched LS signals
Takes oil from P line, pressure reduced to 35 bar
(definitely adjusted), pressure relief valve set to
45 bar
LU
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 35/46
22 36
10
70
35
12.5
113 10
88
133 65 133 83
LSS
M
LS
130
130
S
102
90
LS
80
27
58 15
92 97
32
35
32
40
T P
T P
38
93 36
97
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 37/46
125
M10
12
M10
60
22 36
75
63
10 113
10
78 35
12
15 153 90
LS
130
130
85
LS
47
40
X
25
Y
133 80 14
64
70
P P
32
40
60
T
46
T
30.5
40
90.5
ca. 34 105
93.5
48,5
25.5
22
51
A B
133
12
33
18
27
38/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
… M – …
… H – …
86.5
63
39
64 56.5
Electrohydraulic operation
Ordering code: Cover A Cover B
… W. …
"b"
86.5
"a"
63
39
108
60
°
135 86
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 39/46
LA LAX
LZ LZX
65 20 65 20
50
50
133 133
T T
X
1 1
130
130
LSZ LSZ
82.5
82.5
Y Y
30.5
30.5
40
40
15 54 15 54
28 28
Ordering code:
LAY
LZY
65 20
50
133
T X
130
LSZ
112
82.5
40
30
18 22
28 54
40/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
LU
20 65
50
35
133 22
130
100
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 41/46
90
LS
27
58
92
130
133 92.5
93.5 82.5
48.5 45
20 65 9 30.5
4
10
Y T
50
1
25
7
22
51
25.5
25.5
A3 B3
3 x 51 = 153
8
284
51
5 A2 B2
8
51
A1 B1 7
P
32
35
65
3
T
2 12.5 130
38 131
88
93
1 Nameplate
133 2 Inlet element J...
261 “Closed center”
45 54 3 Directional valve elements
4 End element LA
5 Control cover H (side A) for
40
hydraulic operation
69
69
7 Stroke limiter
8 Secondary valves
32
9 Tie rod
31 10 Mounting thread
4 x M10; 15 deep
42/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
236
157.5
135 133
440
98
46
25 78 8 114
9
4.1 15
46 30
3.2
23
6.2
A3 B3
7
46
1 A2 B2
12
44
T
30
118
40
45
76
344
90
63
MP
75
20
40
P X
S
22
51
A1 B
25.5
3.1 5 6.1
50
1
35
4.2
18 20 25
106 48.5 40
85 47
93.5 130
28
48 1 Nameplate
113 2 Central inlet element JK…
“Closed center”
141
3.1 Directional valve element M4-15
125 64
3.2 Directional valve element M4-12
4.1 End element LA
63
Note!
Connecting cables and plugs are not included in the scope of
supply and must be ordered separately (see also page 63).
Attention!
Please observe the safety notes of the operating instructions
Coding 2 RE 64815-B at all times.
(gray plug-in connector) – Bosch Rexroth warrants the correct functioning of the unit as
described in the operating instructions RE 64815-B. With
this unit, Bosch Rexroth declines any warranty for the safe
operation of the machine or plant of which this unit is a part.
Coding 1
(black plug-in connector)
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp. 45/46
Special cable
Connecting cable
Plug-in
R917005459 connector Coding 1 (black), dummy plug
R917002627 Plug-in Coding 2 (gray), dummy plug
connector
Plug-in
R917005458 connector Coding 1 (black), dummy plug with integrated final resistance
R917004605 Plug-in Coding 2 (gray), dummy plug with integrated final resistance
connector
Plug-in
R900785606 connector Bosch Kompakt coding 1 (black)
kit
Plug-in
R900785607 connector Bosch Kompakt coding 2 (gray)
kit
46/46 Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
Notes
Bosch Rexroth Corp. © This document, as well as the data, specifications and other
Hydraulics information set forth in it, are the exclusive property of Bosch Rexroth
Corporation. Without their consent it may not be reproduced or given to
2315 City Line Road
third parties.
Bethlehem, PA 18017-2131
USA The data specified above only serve to describe the product. No
Telephone (610) 694-8300 statements concerning a certain condition or suitability for a certain
Facsimile (610) 694-8467 application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
www.boschrexroth-us.com
verification. It must be remembered that our products are subject to a
natural process of wear and aging.
RA 64283/11.10 | M4-15 Hydraulics | Bosch Rexroth Corp.
Notes
Bosch Rexroth Corp. © This document, as well as the data, specifications and other
Hydraulics information set forth in it, are the exclusive property of Bosch Rexroth
Corporation. Without their consent it may not be reproduced or given to
2315 City Line Road
third parties.
Bethlehem, PA 18017-2131
USA The data specified above only serve to describe the product. No
Telephone (610) 694-8300 statements concerning a certain condition or suitability for a certain
Facsimile (610) 694-8467 application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
www.boschrexroth-us.com
verification. It must be remembered that our products are subject to a
natural process of wear and aging.
Bosch Rexroth Corp. | Hydraulics M4-15 | RA 64283/11.10
Notes
Bosch Rexroth Corp. © This document, as well as the data, specifications and other
Hydraulics information set forth in it, are the exclusive property of Bosch Rexroth
Corporation. Without their consent it may not be reproduced or given to
2315 City Line Road
third parties.
Bethlehem, PA 18017-2131
USA The data specified above only serve to describe the product. No
Telephone (610) 694-8300 statements concerning a certain condition or suitability for a certain
Facsimile (610) 694-8467 application can be derived from our information. The information given
does not release the user from the obligation of own judgment and
www.boschrexroth-us.com
verification. It must be remembered that our products are subject to a
natural process of wear and aging.