You are on page 1of 4

Service Data

Vickers®
Vane Motors

Vane Motors
35M & 36M Series
-20 Design

Revised 09/01/85 M-2742-S


j Note
Saturate the felt wiper with oil before
assembly. Also, apply a small amount
of grease to inner circumference of
seal before installation of shaft. As-
semble seal with lip toward bearing.

312054
Cover
Oil At Ass’y

11173 Screw
(4 req’d) Drain
Torque to Connection
190-210 lb. ft.
Oil At Ass’y

Pressure
Vane Kit
Screw Plate
10
Model Cartridge Back-up (2req’d) S/A Pin Pressure
”O” Ring Rotor Vanes Ring
Designation Kit Ring Torque to (Including (2 req’d) Plate
30
8-12 lb. ft. Bushing
Springs
and Pins)
3*M80*-**20 923165 310870
3*M95*-**20 923166 Y 271735 Y199814 255837 310877 310874 923164 216603 310868 309430
3*M115*-**20 923167 310871
These parts are services in Cartridge Kit

 Eaton Hydraulics, Incorporated 2000


All Rights Reserved
Model Designation Bearing
35M**-**20 14654
36M**-**20 16058

119982
Retaining Ring
237832 Lock Ring
Y Back-up Ring (See table)

Y ”O” Ring (See table)

312056
Hub Adapter
Y ”O” Ring (See table)

Y ”O” Ring
(See table)
FB-C-10
Y ”O” Ring (Includes Screws)
(See table)

Y Back-up Ring
(See table)

jY 200465 Wiper

jY 394973 Shaft Seal

274382 Retainer

312055 Body

Model Designation Shaft Key


3*M**-1*20 310872 217596
3*M**-11*20 310873

Model Cartridge Back–up Back-up


Designation ”O” Ring ”O” Ring ”O” Ring ”O” Ring
Kit Ring Ring
3*M80*-**20 923165
3*M95*-**20 923166 Y199814 Y271735 Y154083 Y271794 Y312092 Y276617
3*M115*-**20 923167
These parts are services in Cartridge Kit

YIncluded in 923163 Seal Kit


Model Code

1 2 3 4 5 6 7 8 9

1 Model Series 5 Bracket Mounting 7 Port Locations


(Viewed from shaft end) (Viewed from cover end)
35 - Standard bearing
36 - Heavy duty bearing 2- Body port @ 12 o’clock A - Cover port opposite body port
3- Body port @ 3 o’clock B - Cover port 90° CCW from body port
6- Body port @ 6 o’clock C - Cover port in line with body port
2 Vane Motor 9- Body port @ 9 o’clock D - Cover port 90° CW from body port
M
6 Shaft Type 8 Design Number
3 Ring Capacity Torque 1 - Straight keyed 20
Rating (lb. in. per 100 PSI) 11 - Splined
80 - 80 lb. in.
9 Special Feature
95 - 95 lb. in.
115 - 115 lb. in.

4 Port Connections
A - 4 bolt flange

For satisfactory service life of these components in industrial applications, use full flow filtration to provide fluid which meets
ISO cleanliness code 20/18/15 or cleaner. Selections from Eaton OFP, OFR, and OFRS series are recommended.
Printed in U.S.A.