You are on page 1of 4
« - : Nee t Zamil? 42-7) Glee pl ie 3 owvovconsnicr TAMIL OFFSHORE SERVICES COMPANY OFFSHORE HOOK UP, UPGRADE MODIFICATION, SCADA INSTALLATION AND COMISSIONING SUPPORT ; (CONTRACT : 6600044802) TOOL BOX TALK Location:KUDETA BARGE Date:15-Jan-2021 Start Tiine:5.45AM. TBT Log No: COAT-00 ’ 4 | | Meeting Duration:30 Minutes Number of Attendees:3 Coating Application (SAES-H-004). 9.1 General Application Requirements PARTICIPANTS SL | Zamil Emp. | Arameo ID / | NameofAtvendee Position No. |i TOAMA 1 8980569 | RAJU BLASTER/ [== =o. BISHWAKARM PAINTER | z 2256298403 | MANO) KUMAR | BLASTER/ tHe : YADAV _ PAINTER aod Hea QC Inspector QC Supervisor Name : ABDUL NAZAR Name R.G. FAJARDO . Discipline : COATING INSPECTOR Discipline MECH: of Signature: Ay Signature: /] “Ur ic : / [4 BT Log, No: COAT-002.. Pare? APPENDIX-1 9 Coating Application 9.1 General Application Requirements 9.1.1 In case of multi-coat application; the primer, intermediate coat, and topcoats shall be of contrasting colors. 9.1.2 All paint materials for each coating system shall be supplied by same manufacturer. Only proprietary thinner from same manufacturer shall be used. 9.1.3 When using inorganic zinc primer, the contractor and désignated coating inspector shalll check for surface zinc oxide formation immediately prior to applying an epoxy topcoat. ‘This shall be determined by examining the surface for the presence of visible insoluble white deposits, overall white appearance and/or white staining.” Any oxide formation shall be removed by high pressure cleaning using sweet water (with maximum chloride contents of 50 PPM and maximum TDS of 500 PPM), or by sweet water hosing followed by scrubbing with stifT brushes to remove zinc salts. The surface shall be allowed to dry thoroughly prior to applying the topcoat. To avoid pinholes and bubbles occurring in the intermediate coat of epoxy, a mist-coat thinned 10 to 20% should first be applied to the inorganic zine primer. Commentary Note: Heavy dry spray during application of inorganic zine primer is prohibited. 9.1.4 Recoating intervals shall be followed as given in the Saudi Aramco Data Sheet (SAES-H-002V/SAES-H-101V). 9.1.5 The finished coating film shall have the following minimum mandatory characteristics: a) The dry film thickness (DFT) shall be within the minimum and maximum limits per the applicable APCS. The dry film thickness shall be checked in accordance with SSPC-PA2, Document Responsibility: Paints and Coatings Standards Committee SAES-H-004 Issue Date: 23 December 2018 Protective Coating Selection and Application Next Planned Update: 23 December 2021 Requirements for Offshore Structures and Facilities Saudi Aramco: Company General Use Page 24 of 81 b) The dry film shall be free of any application related defects such as but not limited to runs, sags, drips, dry spray or foreign matter. ©) The dry film shall have a uniform appearance. 4) Adhesion strength of all coating systems shall not be less than that required in the appropriate Saudi Aramco Materials System Specification. €) Holiday test is required for the coatings of splash zone and submerged areas, 100 volts per mil 1) Areas with blisters, cracks, porous or below minimum dry film thickness shall be repaired. ‘TRT Lom No: COAT-002. Pao Coating Application 9.1 General Application Requirements 9.1.1 In case of multi-coat application; the primer, intermediate coat, and topcoats shall be of contrasting colors. 9.1.2 All paint materials for each coating system shall be supplied by same manufacturer. Only proprietary thinner from same manufacturer shall be used. 9.1.3 When using inorganic zine primer, the contractor and designated coating inspector shall check for surface zinc oxide formation immediately prior to applying an epoxy topcoat. This shall be determined by examining the surface for the presence of visible insoluble white deposits, overall white appearance and/or white staining.” Any oxide formation shall be removed by high pressure cleaning using sweet water (with maximum chloride contents of $0 PPM and maximum TDS of 500 PPM), or by sweet water hosing followed by scrubbing with stiff brushes to remove zine salts. The surface shall be allowed to dry thoroughly prior to applying the topcoat. To avoid pinholes and bubbles occurring in the intermediate coat of epoxy, a mist-coat thinned 10 to 20% should first be applied to the inorganic zinc primer. Commentary Note: Heavy dry spray during application of inorganic zine primer is prohibited. 9.1.4 Recoating intervals shall be followed as given in the Saudi Aramco Data Sheet (SAES-H-002V/SAES-H-101V). 9.1.5 The finished coating film shall have the following minimum mandatory characteristics: a) The dry film thickness (DFT) shall be within the minimum and maximum limits per the applicable APCS. The dry film thickness shall be checked in accordance with SSPC-PA2. Document Responsibility: Paints and Coatings Standards Committee SAES-H-004 Issue Date: 23 December 2018 Protective Coating Selection and Application Next Planned Update: 23 December 2021 Requirements for Offshore Structures and F: S Saudi Aramco: Company General Use Page 24 of 81 b) The dry film shall be free of any application related defects such as but not limited to runs, sags, drips, dry spray or foreign matter. ¢) The dry film shall have a uniform appearance. 4) Adhesion strength of all coating systems shall not be less than that required in the appropriate Saudi Aramco Materials System Specification. ©) Holiday test is required for the coatings of splash zone and submerged areas, 100 volts per mil. £) Areas with blisters, cracks, porous or below minimum dry film thickness shall be repaired 9.1.6 In case of brush application, the maximum brush size used shall be 125 mm. ‘TBT Log No: COAT-003. Pane? 9.1.7 Paints to be spray applied shall be filtered through a 30 to 60-mesh screen prior to use and shall be continuously agitated with a low-speed stirrer during application. 9.1.8 Coating systems having glass flake, ceramic beads, and any other reinforcement additives shall not be filtered as required in 9.1.7. 9.1.9 Splash zone coating,maintenance shall be done on reachable areas that can be accessed for coating application

You might also like