You are on page 1of 3

Zam.i lf' 4~ 1 wWJ ::. 1 ' j_4 !

_;J J; --,P
o/~:;ttofct Go!Jsrwcr.Qn ZAMIL OFFSHORE SERVIC.E S COMPANY
OFFSHORE HOOK UP, UPGRADE MODIFICATION, SCADA INSTALLATION
AND COMISSIONING SUPPORT
(CONTRACT: 6600044802)

TOOL BOX TALK


Location: Zamil-406 Date: 7-1-2021

Start Time: 08.30 AM TBT Log No : TBQM-ZAMIL-406-


COAT-010

Meeting Duration: 30 Minutes Number of Attendees: 02

Topics Discussed:

SAUDI ARAMCO REFERENCE STANDRAD: SAES-H-004


Coating Preparation and Airless Spray Coating Application

PARTICIPANTS

51. Zamil Emp. Aramco ID I Name of Attendee Position Signatme


No. # IQAMA

1 -c;r;~
63185 2161136284 Jainul Rain Blaster /Painter

~~
2 Gen . Supervisor
61922 8904114 Ronnie Centeno
3 7
4

QC Inspector : QC Supervisor
Name: ABDUR RAHMAN Name :
Discipline : QC COATING INSPECTOR Discipline :

Signature: Signature:

TBT Log No: TBOM-ZAMIL-406-COAT-010 Page 1


APPENDIX-I

Coating Preparation and Airless Spray Coating Application


1. Coating preparation and equipment cleaning shall be performed under the supervision ofthe
coating crew supervisor. Coatings shall be mixed in an open area or in an adequately ventilated
area. Use eye protection (goggles), respirators/ protective gloves and other safety equipment.
2. Electrically driven power mixers shall be grounded.
3. Avoid splash or spillage during mixing. Clean spilled paints immediately using proper cleaning
solvent.
4. Airless spray guns shall never be pointed at anyone or at any part of the body.
5. The tip guard shall always be in place on the airless gun while spraying.
Leather gloves shall be worn by the operator whenever the airless spray gun is in use.
6. The trigger safety catch shall be engaged whenever the airless gun is left unattended.
7. Hoses/ pumps 1 and accessories shall never be operated at pressures exceeding their rated
pressure. In no case shall the working pressure in the coating line exceed 34.5 MPa (5000 psi). If
pressure is expected to exceed 34.5 M Pa (5000 psi), a safety pressure relief valve shall be used
on the discharge side of the pressure pump(s).
8. The pump shall be shut down and the fluid pressure in the system relieved before servicing or
cleaning any components 1 including clogged spray tips.
9. Hoses shall be grounded and anti-static type.
10. Airless spray equipment shall not be operated unless all grounds (earths) are in place/
connected/ and in good condition. Grounding wire shall be AWG-4 or larger.
11. Airless spray equipment shall not be operated if any ofthe pressure system components is
not in good condition .
12. Solvents shall not be flushed into containers that are hotter than 50°C.
Emergency medical care shall be obtained immediately if any high pressure fluid from the airless
equipment penetrates the skin. (High pressure fluid injection injuries can be extremely serious/
including the need for amputation).
13. Benzene 1 gasoline/ carbon tetrachloride/ and chlorinated hydrocarbons shall not be used.

TBT Log No: TBOM-ZAMIL-406-COAT-010 Page 2


(V)
Cl)
or
ro
0...
0
,.....
0
I
~
0
u I
CD
0
'<f<
-
I
....:l
:E
~ I
:E
0
~

You might also like