L[R.

A]06

L[R.A]06
(To be read in conjunction with standard specifications)
L[R.A]09 L[R.A]09 (All dimensions are in millimetres)
AB C D E F G H I J K LM AB C D E F G H I J K LM RESIDENTIAL & COMMERCIAL BUILDINGS
16,500 16,500
1.1. All dimensions to be checked on site, written dimensions to be followed in preference to scaled dimensions.
400 1,200 2,000 1,900 2,000 1,150 1,150 2,000 1,900 2,000 1,200 400 400 1,200 2,000 1,900 2,000 1,150 1,150 2,000 1,900 2,000 1,200 400 2. Depth of foundations to be determined on site but not to be less than 1200 deep.
100 300 100 100 300 100 3. Wall foundations to consist of [Link] concrete mix, reinforced with 3 Nos. 16mm diameter M.S. bars with 8 mm diameter M.S. bar
200 200 3,000 200 1,700 200 2,350 150 150 2,350 200 1,700 200 3,000 200 200 200 200 3,000 200 1,700 200 2,350 150 150 2,350 200 1,700 200 3,000 200 200 links at 300 c/c.
375 350 375 350 Cover to reinforcement to be 75 minimum. (R.C. foundations of columns to Structural Engineer's detail).
300 1,200 2,700 600 800 800 1,100 750 1,100 800 825 600 2,700 1,200 300 300 1,200 2,700 600 800 800 1,100 750 1,100 800 825 600 2,700 1,200 300 4. D.P.C. to be three-ply approved quality bituminous felt.
5. Foundations should not encroach into adjoining plots.
6. 500 g polythene sheeting and anti-termite treatment to be provided under ground floor concrete slab.
W3 W3 W3 W3 7. The ground floor level to be minimum 600 above the existing natural ground level or as agreed on site.

200

200

200

200
W4 BALCONY W4 W4 BALCONY W4
8 BALCONY 8 8 BALCONY 8 8. Garage and carport floor slab to be reinforced with B.R.C. mesh 64.
[Link] f.f [Link] f.f

1,600

1,600

1,600

1,600
STORE [Link] f.f STORE STORE [Link] f.f STORE 9. All walls less than 200 thick to be reinforced with hoop iron at every alternate course.

200

200

200

200

200

200

200

200

200

200
1,200

1,200

1,200

1,200
1,200

1,200

1,200

1,200
1,000

1,000
1,000

1,000
[Link] f.f D5 300 D5 [Link] f.f [Link] f.f D5 300 D5 [Link] f.f 10. P.V. denotes permanent vent and F.L. denotes fan-light.

W4

W4

W4

W4
3,000 200 1,700 200 2,350 W2 150 150 W2 2,350 200 1,700 200 3,000 200 3,000 200 1,700 200 2,350 W2 150 150 W2 2,350 200 1,700 200 3,000 200
BEDROOM 01 BEDROOM 01
11. All reinforced concrete work is to be in accordance with Structural Engineer's details.
7 BEDROOM 01 7 7 BEDROOM 01 7

200

200
D5 D5 12. All sanitary work to be in accordance with M.O.H. rules and regulations.
MOTHERWELL JUNIOR SCHOOL [Link] f.f D5
[Link] f.f [Link] f.f D5
[Link] f.f

200

200

200

200

200

200
13. Urinals to consist of glazed clay.

3,300

3,300

3,300

3,300
3,300

3,300
3,300

3,300

3,300

3,300
14. Where drain passes under building or drive-way area, pipe to be of cast iron or encased in 150 concrete.

DINNING2,100

DINNING2,100
2,300

2,300

2,300

2,300
200 1,800 150 1,050 200 2,700 150 1,600 200 1,575 150 2,725 200 1,050 150 1,800 200 200 1,800 150 1,050 200 2,700 150 1,600 200 1,575 150 2,725 200 1,050 150 1,800 200 15. All wate pipes and soil pipes are to be in ducts and the bends to have all cleaning eyes accessible from outside.

2,700

2,700

2,700

2,700
DW

DW

DW

DW
16. All windows to have P.C. cill, built-in P.V., pelmet box and timberwindow board to detail. Sitting & Dining rooms to

[Link] f.f

[Link] f.f
[Link] f.f

[Link] f.f
DINNING

DINNING
[Link] f.f

[Link] f.f
KITCHEN

KITCHEN
[Link] f.f

[Link] f.f
KITCHEN

KITCHEN
have bigger pelmet boxes to detail.

3,500

3,500

3,500

3,500
200

200

200

200
WARDROBE WARDROBE WARDROBE WARDROBE 17. All windows and external glazed doors to have burglar proofing to detail.

3,500

3,500
6 D3 D3 6 6 D3 D3 6 18. Provide standard type timber cornice and skirting where required.

SHWR

SHWR
19. All door frames to be rebated & moulded & be full width of wall with moulded architraves to detail. Provide rubber

1,200 200

200

200

1,200 200

1,200 200

200

200

1,200 200
SHWR

SHWR
D4 D4 D4 D4

W3

W3

W3

W3
WC WC WC WC

1,400

1,400

1,400

1,400

1,400

1,400
600

600

600

600
1,200

1,200

1,200

1,200
200 2,100 150 1,050 200 4,450 200 4,450 200 1,050 150 2,100 200 200 2,100 150 1,050 200 4,450 200 4,450 200 1,050 150 2,100 200 door stops to all doors.
20. Stair case doors to be self closing and 1/2 hour fire resistance.
F F F F

200

200
1,849

1,849

1,849

1,849
21. All internal plaster to be lime, two coats steel float finished.

1,050

1,050

1,050

1,050
5 5 5 5 22. No roof timber to be placed within 300 of chimney flue.

11,550

11,550
1,450 150

1,450 150

1,450 150

1,450 150

1,450 150

1,450 150

1,450 150

1,450 150
200

200

200

200
1,000

1,000
D3 D3 D3 D5 D5 D3 23. All sanitary fittings to be ''shanks'' or ''armitage'' or other approved type.
100 100

11,550

11,550
1,600

1,600

1,600

1,600
200 2,100 150 1,050 200 3,300 200 1,000 1,000 200 3,300 200 1,050 150 2,100 200 2,100 150 1,050 200 3,300 200 1,000 1,000 200 3,300 200 1,050 150 2,100 24. Provide 1500 high white glazed wall tiles on all exposed walls in kitchen, baths, toilets, showers and cloak rooms.

600

600

600

600
CHRIST GOSPEL

W3

W3

W3

W3
SHWR

SHWR
SHWR

SHWR
150

150

150

150
03 23 03 23
CHURCH - MUTUNGO WC D4 04 02 22 D4 WC WC D4 04 02 22 D4 WC 25. Provide medicine cabinet with mirror and glass shelf over all W.H.B. (except in domestic staff house) size
05 01 21 05 01 21 600 x 400 x 150 deep.
4 4 4 4
PLOT 06 06

[Link] f.f

[Link] f.f
20 20 26. Provide approved type C.P. shower fittings with tap, C.P. towel rails, hooks, bolts etc. in bath and showers. All

LOUNGE

LOUNGE
4,450
200

200

200

200

200

200

200

200
[Link] f.f

[Link] f.f
LOUNGE

LOUNGE
WARDROBE 07 19 WARDROBE WARDROBE 07 19 WARDROBE

4,450

4,450

4,450
tubs to have telephone shower fittings. (W.H.B. to have mixer fittings)

L[R.A]08

L[R.A]08
2,250

4,250

2,250
08 18 08 18

4,250

4,250

4,250
L[R.A]10

L[R.A]10
09 17 09 17 27. All manholes within building area, drive-way and parking area to have heavy duty air tight covers and double

MASTER BEDROOM

MASTER BEDROOM
als

10 16 10 16 sealed.

MASTER BEDROOM

MASTER BEDROOM
2,850

2,850

2,850

2,850
11 15 11 15
Existing Rent

28. Provide G.I. 125 X 100 rainwater down pipes and 125 x 100 G.I. box gutter with brackets etc. where shown.

4,700

4,700

4,700

4,700
4,250

4,450

4,250

4,450
12 12

[Link] f.f

[Link] f.f
14 14

[Link] f.f

[Link] f.f
29. Provide 150 wide open rainwater concrete channels 1800 long to all downpipes.

3,700

3,700

3,700

3,700
3,700

3,700
13 13

3,700

3,700
30. Painting to be 4 coats (last coat at retention time).

1,000

1,000
31. Lay 1 layer of paving slabs 600 x 600 on sand along the perimeter of buildings & S.Q.

200

200

200
OAD D2
KAZINDA G-R 3 3 3 3 32. Provide D.P.C. to all boundary walls.

200
RIN
ROAD NGO D1 D1 33. Each house, flat or floor to have separate water & electrical meter. Owner to pay meter charges.
MUTU W5 D1 W5 W5 D1 W5

200

1,400 200

200

200
1,050

1,050

1,050

1,050
200 3,300 200 500 2,300 500 200 2,100 200 500 2,300 500 200 3,300 200 200 3,300 200 500 2,300 500 200 2,100 200 500 2,300 500 200 3,300 200 34. All ironmongery to be imported type. Samples to be produced.

200 1,400
1,600

1,600
200

200

200

200
200

200
950
BALCONY Step 01 BALCONY BALCONY BALCONY 35. Samples of fittings, materials etc. to be produced & approved before commencing work.
2 2 2 2

2,100

2,100
[Link] f.f [Link] f.f [Link] f.f [Link] f.f
350

750

750
350

350

750

750
350
200

200

200

200

200

200
W1 W1 W1 W1

300

300
550

550
l 1 03 03 1 1 1
ote 350
550

550

550

550
Steps

Steps
eH
02 02 WAREHOUSES, FACTORIES, WORKSHOPS ETC.
200

200

200

200

200
u 400 2,600 500 700 700 400 2,600 500 350 150 2,700 150 350 350 150 2,700 150

300
q

650
01 01
uti

300
Bo 2.1. The following clauses mentioned above to apply 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 18, 19, 20, 21, 23, 27, 28, 30
e

150

150
D er 32, 34.
OA mi 1,050 1,500 1,500 500 350 2,000 450 1,800 850 2,000 350 500 1,100 1,500 1,050 1,050 1,500 1,500 500 350 2,000 3,100 2,000 350 500 1,100 1,500 1,050
G
-R Pre 2. All office windows to have P.C. cills, built in P.V., Pelmet boxes & timber window Cills & Skirtings.
RIN 200 3,300 200 3,300 200 2,100 200 3,300 200 3,300 200 200 3,300 200 3,300 200 2,100 200 3,300 200 3,300 200 3. Steel trusses/portal frames & purlins to be painted with 2 coats of oil paint.
O
U NG 4. Windows to be burglar proofed with 16 mm twisted M.S. bars at 125 mm c/c, lugs, stiffners etc. to be provided.
M UT 300 1,200 2,000 1,900 1,600 1,150 1,150 1,600 1,900 2,000 1,200 300 300 1,200 2,000 1,900 1,600 1,150 1,150 1,600 1,900 2,000 1,200 300 5. All steel doors to have wickets to detail.
6. All steel doors to be made of 75 x 75 x 6 M.S. angle frames with 14 g thick M.S. plate panels & provided with heavy duty
16,500 16,500 hinges/sliding gears & 3 Nos. cleats on both sides for locks, handles etc. If sliding gear is outside provide G.C.I.
AB C D E F G H I J K LM AB C D E F G H I J K LM cover. Each panel should not be bigger than 600 x 600.
7. Toilets - provide white glazed tiles to 1200 height everywhere. Provide mirrors 600 x 450 over all W.H.B.s, paper

L[R.A]06

L[R.A]06
L[R.A]07 L[R.A]07 holders, 2 Nos. coat hooks behind each door.
GROUND FLOOR PLAN L[R.A]03 TYPICAL 1ST, 2ND & 3RD FLOOR PLAN L[R.A]03
N
8. Fire Fighting Equipment to be provided as shown on plan.
9. Each Godown to have separate water & electrical meter. Owner to pay for meter charges.
LOCATION PLAN L[R.A]01 PROPOSED RESIDENTIAL APARTMENTS SCAL[Link] PROPOSED RESIDENTIAL APARTMENTS SCAL[Link]

3
PROPOSED RESIDENTIAL APARTMENTS NOT TO SCALE ROOF NOTES:
250 pitch angle
Gauge 28 versetile roofing sheets
TARMAC DRIVES
Proposed CEILING NOTES: U-Channel Concrete Gutter
100x50mm purlins on 3.1 50 mm Premix laid in two layers on 150 quarry chips on 300 hardcore filling well consolidated & rolled with 14 tons
Waste screeded with Galvanised
Bin Boundary wall 100x50mm rafters on
15mm plaster ceiling on, roller. Provide P.C. Curbs to all sides. Drives to be well sloped for draining the rainwater.
G at g

metal lathe fixed on, Steeel gutter Topping


tin

Waste 100x50mm struts on


Bin 50x50mm timber brandering &
4,7

150x75mm tie beam 0n


e

100x50mm timber joists


4,2 ROOFING FELT ON R.C. SLAB
00

Exis

100x75mm wall plate on


M.H at 600mm centers.
35 25x230mm fasciaboard 4.1. Four layers of Bituminous roofing felt on 50 pumice screed on 50 hollow pots on R.C. flat roof to structural
1 2 3 4 5 6 7 8 Engineer's detail, screed laid to fall min. 75 in 3000 (provide aluminium trim on all edges).
75

550 1,050 2,850 1,600 1,400 2,300 1,200 First layer asbestos based felting 16 kg/10 sq.m.
1,5

Second layer asbestos fellting 23 kg/10 sq.m.


Existing Septic Tank Third layer asbestos based felting 50 kg/10 sq.m.
Top layer 12 stone chippings bedded in bituflex. (If 3rd layer is mineral finish, chippings may not be laid).
to be demolished 2. Guarantee of 2 years to be provided.
3. Lay Funtkote to ''colas A4 specification''.
M.H Existing
Property Boundaries
26, Boundary wall 5.1. All Existing work shown uncoloured.
ers Y

700
500
f. f

Wall plate Level


. P WA

All new work shown shaded or in Red.


M.H

600
Work to be demolished dotted or in yellow.
Co ALK
av

+12000mm
This drawing is to be read in conjunction with drawing Nos.

200
2,9
nc

250

250
W

10

250
Existing Building to

3,000
TRUE NORTH KITCHEN

1,900
be demolished P.C. SUMS OR PROVISIONAL SUMS

2,550
2,800
2,550
6.1. Contractor is to include the following P.C. Sums or Provisional Sums in his Contract and must allow for attendance
STAIRWAY
00

to all Sub-Contractors and his profit in his Tender.


M.H Property Boundaries Third Floor Level

550
200
19,7

a) Contingencies: Shs. .........................................................................................................

200
+9000mm

150
150 1,500
M.H Proposed Stormwater b) Electrical work: Shs. .........................................................................................................
L

250

250
2,4 Channel
T A

50 c) Gates, pillars and Electrical lamp wiring etc.: Shs. .........................................................................................................

3,000
EN TI

KITCHEN

2,000
2,550
2,850
Proposed d) Drive-way and parking areas: Shs. .........................................................................................................

150
03
PM EN

2,4 Boundary wall


Existing Boundary wall 50 STAIRWAY
e) Fittings: Shs. .........................................................................................................
1,9
00

550
Second Floor Level

el

200
30
LO SID

f) Plumbing: Shs. .........................................................................................................


5,0

2,700
nn
+6000mm
04 2,4

150
ha
50 g) Lithography charges payable

250
M.H (M/S DESIGNPLAN BURAEU) Shs. .........................................................................................................
VE RE

eC

150
M.H

3,000
05
2,0

3,200
KITCHEN h) Complete roof work, fabrication &

2,550
2,850
50
ag
SOAK
ers Y

installation etc. by Contractor Shs. .........................................................................................................


DE ED
f.f
. P WA

150
PIT
ain
i) Shs. .........................................................................................................
Co ALK
av

06 First Floor Level STAIRWAY

200
OS

Dr
nc

Existing Building to
W

2,700
+3000mm j) Shs. .........................................................................................................
be demolished

150
er

SE
OP

250

250
TA TIC
0.043ha E
at

NK
V

150
1,5 R
W

3,000
PR

00 E FLOOR AND FLOOR AND

2,000
KITCHEN
ES
LOCATIONS DADO WALLS FITTINGS

2,850
SKIRTING SKIRTING

2,550
rm

AY f.f R

150
15

M.H W ers D
7,4

A
to

E
75
v
IV . Pa O

1,650

550
Ground Floor Level
2,3 R
85

gS

DR onc STAIRWAY
2,0

+000mm

600
C
FA

in

e
LL

450
at
ist

G
Ex

FOUNDATION NOTES:
ng
AD
75

Non slip ceramics tiles


M.H 550 i
0
1,7

d
FA

Existing Toilets to be demolished 200mm oversite concrete [Link] mix on


il d 0
LL

1000 Gauge poluthene sheet (DPM)


0
RO

600 S , SECTION L[R.A]06 250mm hardcore fillings on

20
Existing Boundary wall 02 well compacted ground with
2,5 PROPOSED RESIDENTIAL APARTMENTS SCAL[Link] 50mm sand blinding.
00
SS

WINDOW SCHEDULE - C[--]02;


00

01
CE

2,5 MARK W1 PV W2 W3 W4 W5
5,0

Property Boundaries
18, 00
100
00

1,500 1,100 1,200 500


AC

600
1,5

Proposed ELEVATION
Boundary wall

1,300
Existing Building to be demolished
NG

1,800

1,800

1,800

2,300
2,400

2,400
2,400

2,400

2,400
l
ne

Existing Boundary wall


TI

1,100
E

an
RV

600

600

600
Ch

c
SE

tri
IS

100
c ARB. No. 075 Proposed Residential Apartments to be
RE

SIZE(WXH) 1,500 X1,800 mm 1,100 X 1,800 mm 600 X 1,300 mm 1,200 X 1,800 mm 500 X 2,300 mm
e
E l ole LEGEND
ge

TOTAL No. 08 08 24 16 08
EX
AD

p
01
DESCRIPTION Aluminium window.100x75mm Aluminium window.100x75mm Aluminium window.100x75mm Aluminium window.100x75mm Aluminium window.100x75mm

built in Mutungo Zone 2, Mutungo Parish,


na

anodised aluminium section with anodised aluminium section with anodised aluminium section with anodised aluminium section with anodised aluminium section with
RO

single 5mm thick clear glazing to single 5mm thick clear glazing to single 5mm thick clear glazing to single 5mm thick clear glazing to single 5mm thick clear glazing to
ai

Detail Detail Detail Detail Detail


KIBANJA BOUNDARY
Nakawa Division, Kampala District.
Dr

Existing Boundary wall DOOR SCHEDULE - C[--]01;


PC No. 3570
er

EXISTING BUILDING MARK D1 PV D2 PV D3 PV [Link] [Link]


at

SITE PLAN L[R.A]02


W

DRAINAGE CHANNEL 2,000 1,800 900 800 800 architectural firm : DESIGNPLAN BUREAU, ARCHITECTS & INTERIOR DESIGNERS, KAMWOKYA, P.O. BOX 8033, KAMPALA
m

PROPOSED RESIDENTIAL APARTMENTS SCAL[Link]


or

ELEVATION
PROPOSED STRUCTURE
St

architect : ALFRED JOEL MULWANA, APARTMENT B1, KCCA FLATS, PLOT 13 STURROCK ROAD, KAMWOKYA, KLA, TEL : 0772-457771
2,400

2,400

2,400

2,400

2,400
g
in

ELECTRIC POLE
ist
Ex

finished floor level finished floor level finished floor level finished floor level finished floor level
owner : MR. KAYONGO PAUL, P. O. BOX , KAMPALA; TEL :
SIZE(WXH) 2,000x2,400mm 1,800x2,400mm 900x2,400mm 800x2,400mm 800x2,400mm
TOTAL No. 08 01 16 16 24

22
DESCRIPTION Solid core mahogany veneered Solid core mahogany veneered Solid core mahogany veneered
Composite Aluminium slidding door Composite Aluminium hinged door
fixed on aluminium frame to detail fixed on aluminium frame to detail
Timber panelled door 50mm thick,
side hung swinging thru.900
Timber panelled door 50mm thick,
side hung swinging thru.900
Timber panelled door 50mm thick,
side hung swinging thru.900
date : Feb, 2022 drawn by : A.K 0773522370 owner`s signature :
,include all accessories ,include all accessories well vanished fixed on an well vanished fixed on an well vanished fixed on an
include all accessories include all accessories include all accessories
(To be read in conjunction with standard specifications)

L[R.A]06
(All dimensions are in millimetres)

4
RESIDENTIAL & COMMERCIAL BUILDINGS
L[R.A]09 1.1. All dimensions to be checked on site, written dimensions to be followed in preference to scaled dimensions.
AB C D E F 18,400G H I J K LM 1 2 3 4 5 6 7 8 2. Depth of foundations to be determined on site but not to be less than 1200 deep.
8 7 6 5 4 3 2 1 3. Wall foundations to consist of [Link] concrete mix, reinforced with 3 Nos. 16mm diameter M.S. bars with 8 mm diameter M.S. bar
550 1,050 2,850 1,600 1,400 2,300 1,200 links at 300 c/c.
300 1,200 2,000 1,900 1,600 1,150 1,150 1,600 1,900 2,000 1,200 300 1,200 2,300 1,400 1,600 2,850 1,050 550 Cover to reinforcement to be 75 minimum. (R.C. foundations of columns to Structural Engineer's detail).
50 250 250 4. D.P.C. to be three-ply approved quality bituminous felt.
250 150 4,250 250 150 7,600 150 250 4,250 150 400
5. Foundations should not encroach into adjoining plots.
250

250
250 50 150

250 50 150
6. 500 g polythene sheeting and anti-termite treatment to be provided under ground floor concrete slab.
UPVC Down Pipe 7. The ground floor level to be minimum 600 above the existing natural ground level or as agreed on site.
8. Garage and carport floor slab to be reinforced with B.R.C. mesh 64.
Line of Building Below

700
Wall plate Level 9. All walls less than 200 thick to be reinforced with hoop iron at every alternate course.
150

150

700
Line of Building Below Line of Building Below Wall plate Level 10. P.V. denotes permanent vent and F.L. denotes fan-light.
8 8 +12000mm 11. All reinforced concrete work is to be in accordance with Structural Engineer's details.
+12000mm
12. All sanitary work to be in accordance with M.O.H. rules and regulations.

1,200
Concrete Gutter
FALL 13. Urinals to consist of glazed clay.
3,100

3,100
Line of Building Below

FALL FALL FALL 14. Where drain passes under building or drive-way area, pipe to be of cast iron or encased in 150 concrete.

3,000
7 7

Line of Building Below


15. All wate pipes and soil pipes are to be in ducts and the bends to have all cleaning eyes accessible from outside.

3,000
Concrete Mould 16. All windows to have P.C. cill, built-in P.V., pelmet box and timberwindow board to detail. Sitting & Dining rooms to
have bigger pelmet boxes to detail.

2,300
250

250
17. All windows and external glazed doors to have burglar proofing to detail.
Third Floor Level
18. Provide standard type timber cornice and skirting where required.
FALL

Third Floor Level


+9000mm 19. All door frames to be rebated & moulded & be full width of wall with moulded architraves to detail. Provide rubber
150

150
FALL +9000mm door stops to all doors.
6 6 20. Stair case doors to be self closing and 1/2 hour fire resistance.
21. All internal plaster to be lime, two coats steel float finished.

1,400
FALL

3,000
22. No roof timber to be placed within 300 of chimney flue.

3,000
Concrete Gutter 23. All sanitary fittings to be ''shanks'' or ''armitage'' or other approved type.
5 5 24. Provide 1500 high white glazed wall tiles on all exposed walls in kitchen, baths, toilets, showers and cloak rooms.
13,400

13,400
25. Provide medicine cabinet with mirror and glass shelf over all W.H.B. (except in domestic staff house) size

FALL
FALL
600 x 400 x 150 deep.

1,600
Second Floor Level
13,400

Line of Building Below

Second Floor Level 26. Provide approved type C.P. shower fittings with tap, C.P. towel rails, hooks, bolts etc. in bath and showers. All
FALL

FALL
Concrete Mould +6000mm
+6000mm tubs to have telephone shower fittings. (W.H.B. to have mixer fittings)

Tank
27. All manholes within building area, drive-way and parking area to have heavy duty air tight covers and double

Slope
Slab
4 4
sealed.

Line of Building Below


8,100

8,100
28. Provide G.I. 125 X 100 rainwater down pipes and 125 x 100 G.I. box gutter with brackets etc. where shown.

3,000
L[R.A]10

3,000
29. Provide 150 wide open rainwater concrete channels 1800 long to all downpipes.

L[R.A]08
30. Painting to be 4 coats (last coat at retention time).

2,850
Slope
Tank

FALL
Slab

31. Lay 1 layer of paving slabs 600 x 600 on sand along the perimeter of buildings & S.Q.
FALL

FALL
FALL

First Floor Level 32. Provide D.P.C. to all boundary walls.


FALL 33. Each house, flat or floor to have separate water & electrical meter. Owner to pay meter charges.
First Floor Level
+3000mm 34. All ironmongery to be imported type. Samples to be produced.
3 FALL 3 +3000mm 35. Samples of fittings, materials etc. to be produced & approved before commencing work.

1,050

3,000
FALL FALL
2 2 WAREHOUSES, FACTORIES, WORKSHOPS ETC.

3,000
Line of Building Below Line of Building Below
150

150
2.1. The following clauses mentioned above to apply 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 18, 19, 20, 21, 23, 27, 28, 30

150 150 250


1 1
300 250

UPVC Down Pipe 32, 34.

550
Line of Building Below Line of Building Below
Ground Floor Level 2. All office windows to have P.C. cills, built in P.V., Pelmet boxes & timber window Cills & Skirtings.
Ground Floor Level 3. Steel trusses/portal frames & purlins to be painted with 2 coats of oil paint.
Concrete Gutter UPVC Down Pipe Concrete Gutter +000mm

600
4. Windows to be burglar proofed with 16 mm twisted M.S. bars at 125 mm c/c, lugs, stiffners etc. to be provided.
250

250
250 300 250 +000mm
150 100 3,100 250 150 5,100 150 150 5,100 150 250 3,200 150 5. All steel doors to have wickets to detail.

300
6. All steel doors to be made of 75 x 75 x 6 M.S. angle frames with 14 g thick M.S. plate panels & provided with heavy duty
300 1,200 2,000 1,900 1,600 1,150 1,150 1,600 1,900 2,000 1,200 300 hinges/sliding gears & 3 Nos. cleats on both sides for locks, handles etc. If sliding gear is outside provide G.C.I.

18,400 ELEVATION L[R.A]08 ELEVATION L[R.A]10


cover. Each panel should not be bigger than 600 x 600.
7. Toilets - provide white glazed tiles to 1200 height everywhere. Provide mirrors 600 x 450 over all W.H.B.s, paper
PROPOSED RESIDENTIAL APARTMENTS SCAL[Link] PROPOSED RESIDENTIAL APARTMENTS SCAL[Link]
holders, 2 Nos. coat hooks behind each door.
AB C D E F G H I J K LM 8. Fire Fighting Equipment to be provided as shown on plan.
9. Each Godown to have separate water & electrical meter. Owner to pay for meter charges.
L[R.A]06

L[R.A]07
ROOF PLAN L[R.A]05 Concrete Mould Concrete Mould
4

PROPOSED RESIDENTIAL APARTMENTS SCAL[Link]


TARMAC DRIVES
3.1 50 mm Premix laid in two layers on 150 quarry chips on 300 hardcore filling well consolidated & rolled with 14 tons
M L K J I H G F E D C B A roller. Provide P.C. Curbs to all sides. Drives to be well sloped for draining the rainwater.
A B C D E F G H I J K L M 300 1,200 2,000 1,900 1,600 1,150 1,150 1,600 1,900 2,000 1,200 300
300 1,200 2,000 1,900 1,600 1,150 1,150 1,600 1,900 2,000 1,200 300
ROOFING FELT ON R.C. SLAB
4.1. Four layers of Bituminous roofing felt on 50 pumice screed on 50 hollow pots on R.C. flat roof to structural
Engineer's detail, screed laid to fall min. 75 in 3000 (provide aluminium trim on all edges).
First layer asbestos based felting 16 kg/10 sq.m.
Second layer asbestos fellting 23 kg/10 sq.m.
Third layer asbestos based felting 50 kg/10 sq.m.

700
700

Wall plate Level Wall plate Level Top layer 12 stone chippings bedded in bituflex. (If 3rd layer is mineral finish, chippings may not be laid).
+12000mm
2. Guarantee of 2 years to be provided.
+12000mm
3. Lay Funtkote to ''colas A4 specification''.

5.1. All Existing work shown uncoloured.

3,000
All new work shown shaded or in Red.
3,000

Work to be demolished dotted or in yellow.


This drawing is to be read in conjunction with drawing Nos.

Third Floor Level Third Floor Level

+9000mm
+9000mm P.C. SUMS OR PROVISIONAL SUMS
6.1. Contractor is to include the following P.C. Sums or Provisional Sums in his Contract and must allow for attendance
to all Sub-Contractors and his profit in his Tender.

3,000
3,000

a) Contingencies: Shs. .........................................................................................................

b) Electrical work: Shs. .........................................................................................................


Second Floor Level Second Floor Level
c) Gates, pillars and Electrical lamp wiring etc.: Shs. .........................................................................................................
+6000mm +6000mm
d) Drive-way and parking areas: Shs. .........................................................................................................

e) Fittings: Shs. .........................................................................................................

3,000
3,000

f) Plumbing: Shs. .........................................................................................................

g) Lithography charges payable


First Floor Level
(M/S DESIGNPLAN BURAEU) Shs. .........................................................................................................
First Floor Level
+3000mm +3000mm h) Complete roof work, fabrication &
installation etc. by Contractor Shs. .........................................................................................................

i) Shs. .........................................................................................................
3,000
3,000

j) Shs. .........................................................................................................

Ground Floor Level Ground Floor Level


+000mm +000mm LOCATIONS FLOOR AND DADO WALLS FLOOR AND FITTINGS
SKIRTING SKIRTING
300
600

ELEVATION L[R.A]09
ELEVATION L[R.A]07 PROPOSED RESIDENTIAL APARTMENTS SCAL[Link]
PROPOSED RESIDENTIAL APARTMENTS SCAL[Link]
No. OF CAPACITY IN PERCOLATION
USERS L B D LITRES TRENCHES
6 1800 675 900 1112.5 7.5m
10 2250 675 900 1417.5 12.2m 140 875 215 4,200 215 875 140
15 2500 675 900 1561.5 14.4m
20 2800 675 900 1800.0 18.3m A
25 3300 675 900 2083.5 30.5m 100mm dia cast iron
Half round C
inlet / outlet pipes

140 750 140


30 2500 900 1050 2358.0 36.6m channel
35 2550 900 1050 2502.0 42.6m
450 40 3000 900 1050 2847.5 48.7m L OUT L
4,400 3,100 3,100 3,100 3300 900 1050 54.8m IN
45 3240.0
75mm thick concrete coping 50 3600 900 900 3685.5 60.0m 100mm dia. B TO SOAK PIT $
Slidding gate L
60 3150 1200 1200 4419.0 66.0m PERCOLATION
inlet / outlet
70 3750 1200 1200 5265.0 73.0m
80 4250 1200 1200 6895.0 79.2m
cast iron pipe C TRENCHES

90 4720 1200 1200 6525.0 85.2m


140 875 215 A 4,200 215 875 140
600

600

600

30x30x1.5mm thick hollow m.s section.


100 5300 1200 1200 7416.0 91.0m
to be painted with
approved gloss paint
125 4200 1350 1500 8842.5 97.0m PLAN (Scale 1:50) 850 x 750 mm
cast iron cover
1 ,400

3,100 3,100 750 x 875mm cast 100mm th. reinforced concrete


cover slab (mix. [Link]) 750 x 875 mm cast
iron cover 750 x 875
mm cast GROUND iron cover
730
730

40x40x1.5mm thick hollow m.s section. iron cover 100mm


LEVEL Benching
frame to be painted with dia. half
100 round rendered 12mm
1 ,400

approved gloss paint channel. thick, finished


100mm dia half round 125 th. conc.
2,600

PART ELEVATION -A1 OF BOUNDARY WALL Benching smooth with steel float
2,600

Texture paint on plastered Texture paint on plastered channel foundation (mix [Link]).
Scale 1:75 WORKING
wall surface wall surface IN OUT 100mm dia.
to Architect's approval to Architect's approval
75mm thick concrete coping LEVEL inlet / outlet SECTION C - C
1 ,200

1 ,200

ARB. No. 075 Proposed Residential Apartments to be


Texture paint on plastered gl. support bracket built into D cast iron pipe
125mm thick concrete base
wall surface 450x450mm blockwork/R.C. B
to Architect's approval column plastered and painted,colour to
(mix. [Link]). Depth to invert
D L
230mm thick block wall
Concrete to foundation (Scale 1:25)
02
level not more than 1500mm 25mm th. cement screed
built in Mutungo Zone 2, Mutungo Parish,
architect's approval. (mix [Link]) to be at
1 ,200

PART ELEVATION -A2 OF BOUNDARY WALL finished smooth with steel float. thickness specified
4,400 3,100 3,100 3,100 230mm thick block wall
Scale 1:75 30x30x1.5mm thick hollow m.s section. 450 plastered and finished in approved Concrete to foundation (mix [Link]) to
SECTION L - L (Scale 1:50) SECTION A - A
450
coping to columns
D
Slidding Gate D To detail X paint be at thickness specified

(Scale 1:50) PC No. 3570 Nakawa Division, Kampala District.


450

Damp proof course Ground level Selected filling well


ENTRANCE
450

compacted and
75 mm thick saddle copping consolidated.
D 850 x 750 mm 750 x 875 cast iron covers
75 mm thick saddle copping Strip foundation mix [Link] architectural firm : DESIGNPLAN BUREAU, ARCHITECTS & INTERIOR DESIGNERS, KAMWOKYA, P.O. BOX 8033, KAMPALA
D 30x30x1.5mm thick
230mm thick concrete 19mm aggregate to S.E's detail cast iron cover with complete frames.
3,100 3,100 hollow m.s section.
block wall
coping to columns
Plastered and painted
450x450mm concrete block column
3,000

to Architect's approval.
450x450mm concrete block column (Reinforced in areas with BOUNDARY WALL SECTION D -D
(Reinforced in areas with retaining wall to S.E's detail. retaining wall to S.E's detail. Scale 1:75 Inlet architect : ALFRED JOEL MULWANA, APARTMENT B1, KCCA FLATS, PLOT 13 STURROCK ROAD, KAMWOKYA, KLA, TEL : 0772-457771
pipe Selected
PART PLAN OF SIDE BOUNDARY WALL stone
PART PLAN OF SIDE BOUNDARY WALL
Scale 1:75 Scale 1:75 profile. 150mm thick R.C cover slab.
owner : MR. KAYONGO PAUL, P. O. BOX , KAMPALA; TEL :
PLAN AT TOP (Scale 1:50)
SECTION THRU SOAK PIT
SCALE 1:50 date : Feb, 2022 drawn by : A.K 0773522370 owner`s signature : 22