You are on page 1of 3

Column below plinth level, Height = 1.

35 m

Column type size No.s bar1 bar2 Remarks


C1 350x350 70 4-20φ 8-12φ Reinforcement in
C2 250φ 8 6-16φ column below plinth
C3 300x300 28 4-16φ 4-12φ level is less than that
above.
6 nos. It needs to be
Column above plinth level, Ground floor. Height =3.0 m confirmed.
C1 350x350 76 4-20φ 8-12φ
C2 300x300 22 4-16φ 4-12φ
C3 250φ 8 6-16φ

Column above plinth level, First floor. Height =3.0 m


C2 300x300 22 4-16φ 4-12φ
C3 250φ 8 6-16φ 2 col. in front of hall reduced
C4 350x350 76 4-16φ 8-12φ

Column above plinth level, Second floor. Height =3.0 m *ht needs to be conformed, stairca
C4 350x350 16 4-16φ 8-12φ For roof cover

Footing and Plinth tie beam. Length=564.108 m.


300x250 2 4-16φ 2-12φ same for footing and plinth tie beam

Footing net size no.s length tot. length


1.5x1.5 76x2 13 1.55 3062.8
1.2x1.2 30x2 10 1.25 750

Estimated Re-bar for work initiation.


20φ bar: (758+912) m 1670*2.47 kg/m 4124.9 kg *(below plinth + ground fl
*790+912 m 1702*2.47 kg/m 4203.94 kg because of 6 confused col

16φ bar: (642+1080) m for 1722.4*1.58 kg/m 9851.3 kg


column + 4513 m for
tie beams

(1702.2+1824) m for
12φ bar: column + 2257 m for 8965*0.89 kg/m 7979 kg
tie beams +3182 m
for footing net

(7205 m + 3952 m +
687 m + 109 m) for
8φ bar: stirrups below plinth 11953*0.4 kg/m 4781.2 kg
level
30.940 tonnes
L bend part of column in footing 12φ
no fo fdn length bar 1 tot length bar 2 tot length
ement in 20φ 76 1.25 4 380 8 760
below plinth 16φ 8 1.15 6 55.2
ess than that
16φ 22 1.15 4 101.2 4 101.2
needs to be
ed.

s to be conformed, staircase cover

nth tie beam

*(below plinth + ground floor)


because of 6 confused column

You might also like