SAUDIARAMCO.

NOTES:
1. FOR STANDARD SYMBOLS / LEGEND AND TYPICAL DETAILS SEE
DRAWINGS B55-A-BA-755674 TO 755677.
SET @ 1050.0 PSIG 2. ALL INSTRUMENT TAG NUMBERS ON THIS P&ID SHALL BE
B90-E-0112A /B /C NOTE-10 3"J4"
1" V
PREFIXED BY 31 UNLESS OTHERWISE STATED.
PZV
REGENERATION GAS HEATERS Down
8"-
HPF-
9927- 3. DCS DEHYDRATION LOGIC CLOSES TV-1091 IF NO
SLOPE 1 mm /480 mm 1CA9P1
+
NO POCKET
1178 SLOPE B90-A-BA-755750-066 REGENERATION GAS REQUIRED. A MINIMUM STOP TO THE
DESIGN DUTY : 58.428 MMBTU/hr
8"x4" CSC TEMPERATURE CONTROL VALVE TO ENSURE MINIMUM FLOW
SURFACE AREA : 9456.0 ft^2 TO HP FLARE
FB AND KEEP B90-E-0112 HOT WHEN NOT IN USE.
OP : 880.0 PSIG

SLOPE 1mm /480mm


6"x3"
4. ALL FIELD INSTRUMENTS ON THIS P&ID ARE PART OF RISK

1CA9P1

OF
OT (IN/OUT) : 85.40 °F / 536.00 °F
DP : 1050 PSIG 1" AREA 4 UNLESS OTHERWISE NOTED.

SLOPE 1mm /480mm


DT : 600.00 °F / 19.00 °F 5. SEQUENCING VALVE SEE DETAIL IN DWG
SET @ 1050.0 PSIG

CONSENT
9928-
TRIM : 6CA9P8 D NO. B55-A-BA-755677-003.
3"J4"
TI OP : 130.0 PSIG 6. VALVE CLOSED DURING HEATING CYCLE AND OPEN DURING
CSC

HPF-
1000 OT(IN/OUT) : 572.00 °F / 350.00 °F PZV COOLING CYCLE.
ZC 1087 FB
DP : 1050 PSIG + 1" V
1031 1179
7. VALVE CLOSED DURING COOLING CYCLE AND OPEN DURING

8"-
DT : 622.00 °F / 15.00 °F 8"

N
1040 HEATING CYCLE.

NO POCKET
FREE DRAI
TRIM : 6CS9U1
8. LEVEL ALARM INDICATES ACCUMULATION OF GAS DUE TO TUBE
FI
CSC

TTEN
FF 8"x4" LEAK ON B90-E-0112.
1030 FB
TIT 6"x3" 9. TO ENSURE VENT DETAIL IS SAFE FOR OPERATOR AND
1"
1087 SPECIFICALLY AVOIDS SPUTTERING OF HOT OIL ONTO
NOTE-17

WRI
OPERATOR.
D H SET @ 78.00 MMSCFD
B/L DETAIL 7 10-12862-0001 FIC FIC FY PIC TI 10.STEAM OUT CONDITION TO BE CONSIDERED :
FF CSC
B53 B90 6"
FIT FB
1029 CL1 1029 1029 1036 1005 15PSI@300°F (TUBE SIDE)
B90 693
6"-
P-9905-
6CA9P8

THE
11. HOT OIL SHALL NOT BE DRAINED UNTIL IT IS COOLED TO 200°F
PI TI TE 1030
ZV 0.00-1400.00 GPM NOTE-3 TO AVOID DAMAGE TO RTR PIPING.
+

1206 1204 1455 1087 H SET @ 554.00 °F 12. ZV AND SAFE LOCATION BUTTONS TO BE LOCATED AT LEAST
1" V H SET @ 940.0 PSIG
0.00-650.00 ° F NOTE-15 FF
7.5M BEYOND THE EDGE OF ANY FIRE HAZARDOUS ZONE.

THOUT
10" 10" 2" 2" 2"-
HPF-
9929-
1CA9P1
PI TIC TIT FI
13 PROVIDE MEANS FOR ACCESS TO THE VENT VALVE.
B53-A-BA-747571-001
1177 1091 1091 1029 14. CYCLIC SERVICE.
PI
10"

6CA9P8
HOT OIL SUPPLY CSO NOTE-18 2"-
P-9929-
6CA9P8 6CA9P8 1CA9P1
AO/AFC -50.00 - 600.00 ° F 10-12862-0001 15. TRIPLE OFFSET BUTTERFLY VALVE.
D NOTE-15 1" D 1" D 1190 L SET @ 829.0 PSIG

WI
1"

6CS1U01
6CS9U1
TSO N 16. PI-1190 &TI-1101 ARE RE-USED. 1A2
B90 652
NOTE-12,15 FE 17. TIE -IN LOCATION IS IDENTICAL TO TRAIN 2. TIE -IN NUMBER

9904-
EC FF FF FF FF
FOR TRAIN 2 IS B90-706 TO 711 SERIES.

NG
3CS9U1 6CS9U1 1030 DETAIL 27
2" TI PI TI PIT TE FIT PIT TIT 12"-
P-8704-
6CA9P8
0.00-1100.00 MMSCFD 18. TO ADD THIS NEW VALVE FOR DBB, ENTIRE SPOOL WILL

DRAWI
P-
1101 1196 1118 1177 1091 1029 1036 1005
10"-
HO -
9914- 10"-
HO -
9915-
6CS9U1 BE MODIFIED.

6"-
3CS9U1 KV
10-12862-0001 MIN. + -50.00-600.00 ° F
1" 0-1300 PSIG FF 0-1300 PSIG LEGEND
1149 1" IAS 1"
B90 695 2M 1"
NOTE-17 4 " V V 4 " PIPING MATERIAL INSTRUMENT DEFINITION & SYMBOLS SAES-J-004
D NOTE-16 14" 12" 12"
14"-
P-8704-
6CA9P8 SPECIFICATION SAES-L-005
10-12862-0001 EC EC B90-A-BA-755686-001 AC/AFO -AIR TO CLOSE/ VE -VIBRATION ELEMENT

S
THI
AIR FAILURE OPEN VS -VIBRATION SWITCH
1A2 14"x12" 12" 10" NOTE-14

2"
B90 673 12"x10" 12"x10" HOT REGEN GAS OR PROCESS LINE AC/AFS -AIR TO CLOSE/AIR VT -VIBRATION TRANSMITTER
NOTE-5,7 AO/AFC

3 1/
FAILURE STEADY XL -PILOT LIGHT

6SD0P02
COOLING REGEN GAS

6CA9P8
AO/AFC FE AO/AFC -AIR TO OPEN/ (NOT FOR MOTOR)

EC
10" INSTRUMENT
TO GAS DEHYDRATORS AIR FAILURE CLOSE -LIMIT SWITCH
PI TI TSO AIR LINE XS

FROM
1029
B90-D-0110A-D AO/AFS -AIR TO OPEN/AIR ZV -SAFETY SHUTDOWN VALVE
1067 1567 FAILURE STEADY
INSTRUMENT
DATA LOGGER POINT

NPUTS
ELECTRICAL LINE AOV -AIR OPERATED VALVE
1 1/2 " F-FLOW P-PRESS.
14"-
P-9908-
6CA9P8 AT -ANALYZER TRANSMITTER
L-LEVEL T-TEMP.
4 "

I
EC B90-A-BA-755694-001 DT -DENSITY TRANSMITTER

NED
X-MISC. A-ALARM
10-12862-0001 ESD -EMER. SHUTDOWN SYSTEM
AT GRADE EC HOT REGEN GAS LOCAL PANEL
FC -FLOW CONTROLLER
B90 694 MOUNTED INSTR.

OBTAI
TO CONDENSATE FV -FLOW CONTROL VALVE
10"-
HO -
0154-
6CS1U01
TA-718864 SHT.001 2" V DEHYDRATORS FCV -FLOW CONTROL VALVE
BOARD MOUNTED
(SELF-ACTUATED) INSTRUMENT
4" 4" 4" 4" B90-D-0111A/B
HOT OIL SUPPLY FE -FLOW ELEMENT
2" V EC EC R/G
1A2 EC EC FG -FLOW SIGHT GLASS
TO B90-E-0119 A/B/C XL STATUS LIGHTS
FHV -FLOW MANUAL CONT. VALVE R=RED, G=GREEN

BE
FHTd -FLOW MANUAL TRANSDUCER PILOT LIGHT (DO NOT
12"-
P-0037-
6SD0P02 FIC -FLOW INDICATOR CONTROLLER USE FOR MOTOR STATUS)
REDUCER
TA-718863 SHT.001 FM -FLOW METER
MOTOR STATUS

PART,SHALL
FO -RESTRICTION ORIFICE ML
SPECTACLE PILOT LIGHT
HOT REGEN GAS FQI -FLOW TOTALIZER INDICATOR
B90-E-0112B 1A2 PLATE-OPEN
B90-E-0119 A/B/C FR -FLOW RECORDER
LOCAL MOUNTED
B90-E-0112A SPECTACLE
FT -FLOW TRANSMITTER INSTRUMENT
FY -FLOW RELAY
PLATE-CLOSED
HIC -HAND INDICATOR CONTROLLER
MOUNTED BEHIND
GATE VALVE HS -HAND SWITCH LOCAL PANEL
LA -LEVEL ALARM
GLOBE VALVE
LV -LEVEL CONTROL VALVE

6CA9P8
RACK MOUNTED
CHECK VALVE LCV -LEVEL CONTROL VALVE (OR BACK OF PANEL)
1" 2" D
2" D (SELF-ACTUATED)
PI PI PLUG VALVE

N
LG -LEVEL GAUGE GLASS ELECTRICAL

I
9912-
D LIC -LEVEL INDICATOR CONTROLLER SUPPLY REQUIRED
1586 1870 BALL VALVE
LI -LEVEL INDICATOR

FULL,OR
DOUBLE DISC LR -LEVEL RECORDER INSTRUMENT

P-
TI TI AIR SUPPLY REQUIRED
GATE VALVE LS -LEVEL SWITCH

14"-
2" V LT
1568 1569 -LEVEL TRANSMITTER
PI TI ANGLE VALVE H
4" 4" LTd -LEVEL TRANSDUCER HIGH LOW
1588 1566 EC EC ML -MOTOR STATUS LIGHT L
PRESS RELIEF
MOV -MOTOR OPERATED VALVE
VALVE NA -ANNUNCIATOR TWO PEN RECORDER
3 1/2 " PB -PUSHBUTTON
VACUUM RELIEF

N
NOTE-11 10"-
HO -
9911-
6CS9U1

I
PC -PRESSURE CONTROLLER FF
EC VALVE FOUNDATION
PV -PRESS. CONTROL VALVE
FIELDBUS INSTRUMENT

ON
M PCV -PRESS. CONTROL VALVE
6CS9U1 1LE9U1 MOTOR OPERATED
(SELF ACTUATED)
B90-E-0112C VALVE

REPRODUCTI
PdC -PRESS. DIFF. CONTROLLER DISTRIBUTED CONTROL/SHARED
2" 2" 2" P
CDS PISTON OPERATED PdI -PRESS. DIFF. INDICATOR DISPLAY SYMBOLS
VALVE PdIC -PRESSURE DIFFERENTIAL
2427 (DCS) DISTRIBUTED CONTROL
INDICATOR CONTROLLER SYSTEM, OPERATOR ACCESSIBLE
CONTROL VALVE
1" D PdIS -PRESSURE DIFFERENTIAL IN CONTROL ROOM
EC N
INDICATOR SWITCH
1A2 P
BALL TYPE (DCS) DISTRIBUTED CONTROL
PdT -PRESS. DIFF. TRANSMITTER
CONTROL VALVE SYSTEM, OPERATOR INACCESSIBLE
2"-
CDS-
9913-
1LE9U1 2" D PdTd -PRESS. DIFF. TRANSDUCER IN CONTROL ROOM
EC C WITH POSITIONER
PG -PRESSURE GAGE
S (DCS) DISTRIBUTED CONTROL
SCOPE UNDER BI-10-128622. SOLENOID VALVE PI -PRESSURE INDICATOR
SYSTEM, OPERATOR INACCESSIBLE
PIC -PRESS. INDICATOR CONTROLLER IN FIELD

SAUDIARAMCO.NO
PR -PRESSURE RECORDER
SET @ 1050.0 PSIG VALVE NORMALLY PS -PRESSURE SWITCH
DISTRIBUTED CONTROL
1-1/2"F2" CLOSED PT -PRESSURE TRANSMITTER
V PZV PX -PRESSURE POINT INTERCONNECTING LOGIC
1" +
6"-
HPF-
9932- 6" PY -PRESS. COMPUTATION MOD. CONTROLLER WITH BINARY
1CA9P1 SLOPE 1 mm /480 mm 1180
B90-A-BA-755750-066 PZV -PRESSURE RELIEF VALVE OR SEQUENTIAL FUNCTIONS
AT GRADE
NO POCKET CSO
RTD -RESIST. TEMP. DETECTOR
(PLC) PROGRAMMABLE LOGIC
TO HP FLARE 6"x2" SI -SPEED INDICATOR
FB CONTROLLER, NORMALLY
SS -SPEED SWITCH INACCESSIBLE OR BEHIND THE
3"x1-1/2" TC -TEMP. CONTROLLER PANEL DEVICE OR FUNCTIONS
SLOPE 1mm /480mm

TV -TEMP. CONTROL VALVE (PLC) PROGRAMMABLE LOGIC


IBT -INVERTED BUCKET TCV -TEMP. CONTROL VALVE CONTROLLER FUNCTION,
1"
Down

(SELF-ACTUATED) CAN BE NORMALLY


STEAM TRAP
PI TE -TEMP. ELEMENT
DISPLAYED ON CRT
PI -TIGHT SHUT OFF
SET @ 1050.0 PSIG D TSO TG -THERMOMETER LOCAL DCS OR AUXILIARY
1191
SLOPE

OF
1-1/2"F2" 1176 S.C. -SAMPLE CONN. THS -TEMP. HAND SWITCH DCS LOCATION NORMALLY
TI -TEMP. INDICATOR ACCESSIBLE TO OPERATOR
S -DRAIN TO
PZV L SET @ 0 ' 10.0 " 43% PRESSURE SEWER
TR -TEMP. RECORDER

PROPERTY
(PLC) PROGRAMMABLE LOGIC
1" V + CSO TS -TEMP. SWITCH
1181 TI FF CONTROLLER I/O POINT
6" TI NOTE-9 & 13 OWS -OILY WATER SEWER
SLOPE 1 mm /480 mm FB TT -TEMP. TRANSMITTER NORMALLY INACCESSIBLE
LI LIT
1100 D -DRAIN TTd -TEMP. TRANSDUCER BY OPERATOR
1089 1137 1137
CSO 2"-
HO -
9921-
6CS9U1 V -VENT TW -THERMOWELL
6"x2" GWR
N

NO POCKET

FB
FREE DRAI

NOTE-8
3"x1-1/2" 2" REFERENCE DRAWINGS
D
1" CSO LETTER IDENTIFICATION OF LINES AD-036204
6"-
HPF-
9930-
1CA9P1

SOLE
PIPING SYMBOLS AB-036227
AT GRADE
6CS9U1

D 4"x2" EQUIPMENT SYMBOLS AB-036305


1000
ZC CSO 1" INSTRUMENT SYMBOLS AC-036950
1031 3" 2"
9916-

FB PIPING LAYOUT INDEX


1040

THE
3"-
HO -
9919-
6CS9U1 PLOT PLAN
D

500M M
CSO

N.
HO -

PROCESS FLOW DIAGRAM


1CA9P1 6CS9U1

MI
ZC 1000
1" HYDROSTATIC TEST DIAGRAM
10"-

ARE
DETAIL 7 2" 2" 1031
14"-
P-8809-
6CA9P8 2"-
HPF-
9931-
1CA9P1 1A2 DRAWING CONTROL FOR J.O.B1-10-12862 TD-718027
1040

6CS9U1
TI INSTRUMENT INSTALLATION SCHEDULES
ZV 10"x4"
2"-
HO -
9920- 1088

N
+ 6CS9U1

HEREI
1451

9910-
1 " 1 " DETAIL 7
B/L
B90-A-BA-755688-001 NOTE-12 PI TI
C C
B90 B53

HO -
ZV 1207 1203
14" FF +
REGEN GAS PI H SET @ 252.0 PSIG TIT 1126
AO/AFC HH SET @ 287.00 PSIG

4"-
THIS DRAWING IS REPRODUCED FROM

NED
FROM MOL SIEVE DUST TSO NOTE-15 1A2
14"x12" 1587 1088 10" DWG.NO. BA-755699 SHT.001 REV.01
FILTER B90-D-0135A/B PI ZC PAHH PI
2" B53-A-BA-747571-001
0.00 - 650.00 ° F

CONTAI
1172 1031 1031 1173
2" 2" 10"
STEAM 2" CSO HOT OIL RETURN
AO/AFC 1" D 1" D

6CS1U01 6CS9U1
CSO
OUT REVISION VALIDATION
TSO
N EC FF NOTE-17
1" D 1" D 6CS9U1 3CS9U1 THIS REVISION NO. 1A2 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
PIT PIT TE 10-12862-0001
MIN. 2M 10"-
HO -
9917-
3CS9U1 REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
3"-
HO -
9918-
6CS9U1 1172 1173 1088 FF

ON
4"x2" B90 674 10-12862-0001-000
0-1200 PSIG 0-1200 PSIG

NFORMATI
KV IAS
+ 10" 2 "
NOTE-11 10" 10"x6" 10"x6" 10" NOTE-11 DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
1158 (DESIGN AGENCY) x REQUIRED (SAUDI ARAMCO)
EC
C
L27

ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE


C NOTE-15 NOTE-15 1" D
6"
NOTE-15
DETAI

EAN CIB IHT AHG


12" EC 2" D 2" D AO/AFC TV 1" D 2" 2"
EC C 2" +
09/01/19 09/01/19 09/01/19 09/01/19
AO/AFC NOTE-3 1091 EC D D
REV.NO. DATE REVISION DESCRIPTION
TSO N N 1" 10"-
HO -
0157-
6CS1U01

I
SP TA-718864 SHT.001 1A2 09/01/19 ISSUED FOR 60% FEL-3 REVIEW
NOTE-5 & 6 N
2"

THE
2" D 6" HOT OIL RETURN FROM
442 JOB ORDER/EWO NO.
1A2 THIS REVISION IS NOT TO BE USED FOR
1" 1" B90-E0119 A/B/C 10-12862-0001 CONSTRUCTION UNTIL CERTIFIED AND DATED

2"-
HO -
9909-
6CS9U1 2"
D D FG
SAUDI ARABIAN OIL COMPANY

AND
2" D 2" D 1025 1"
DRAWING TYPE

6CS9U1
2"-
CDS-
9942-
1LE9U1 D
PIPING & INSTRUMENT DIAGRAM PID
2"-
CDS-
9943-

NG
1LE9U1
2" REGENERATION GAS HEADER-TRAIN 1

DRAWI
1375
CDS

1572
CDS

2"-
CDS-
9944-
1LE9U1

1LE9U1
NGL RECOVERY AREA
OWS
SHAYBAH SAUDI ARABIA
4 "

S
NOTE 14 12"-
P-9907-

1574
6CA9P8 PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

CDS

THI
EC

B90 A TA-755699 001 1A2