Professional Documents
Culture Documents
MARL (NOTE-11)
NOTES: (SEE BELOW)
CLASS
CLASS 1
LOCATION
LEGEND:
DESIGN
0.72
FACTOR PIPELINE CENTERLINE
OF
T
T
P
EXISTING PIPELINE - ABOVE GROUND
CONSENT
8
8 T T
P POWERLINE AND POLES
PC-3 -
PC-2 PI-2 STA 0+943.70 T
m
L
P
C C UNDERGROUND CABLE
P
K
STA 0+532.74 N 2708235.890 N 2707952.537 /
8 T K C
N 2708244.197 E 307779.117 E 308049.994 L
/ T T TELEPHONE LINE
E 307761.583 R=105.00m P
TTEN
PI-3
G
T
D=20°56'16.86" /
P
8
N 2707910.304 PAVED ROAD
P
PI-1 T A
L=38.37m
0
E 308090.368
0
0
0
0
N 2708440.467
WRI
+6
0
T=19.40m
+
+
+
DIRT ROAD
+
6
+
R=105.00m
8
8
.2
9
9
E 307411.629
9
4
3
2
5
2
T
2
NOTE-2 D=58°11'13.90"
0
T
4
5
6
R=105.00m
5
0
9
P
TRAIL
.9
9
.6
.1
.1
K
.4
P
.1
T
.3
+
0
K
L=106.63m
THE
4
D=37°09'14.6"
5
4
ROW 0
6
+
136°17'22"
8
0
4
9
4
T=58.43m
+
0
5
L=68.08m RAILROAD TRACK
0+600
0+700
0+800
0+900
7
372.60m
4
+
.4
C
8
6
4
P
T=35.56m 8
PT-3
.7
0
2
0
4
PC-1
T
+
0
.3
THOUT
P
8
A
T
6
STA 1+050.34 GUARD RAIL
0
/
0+
.1
/G
200
4
STA 0+253.13
0
0
G
0
1+
0
N 2707853.732
50
PC-0 PT -2 m -
U
0
+
N 2708365.397
C
.4
E RETAINING WALL
P
/
+
3
E 308075.763
A
0
8
'
STA 0+097.09 STA 0+571.11
7
+
/L
3
5
E 307509.734
B
P
3
0
3
WI
5
L
K
0
T
0
T
N 2708440.467
°2
N 2708221.865
G
4
P
U
5
8
.7
DIKE, SAND WALL
U
0
'
K
0+
2
/
/
P
.8
C
6
U
/
E 307376.065
U
E 307792.524 2
P
74
L
G
.9
(T
/L
G
/
9
/
0
40
/
8
STA 0+154.28
°3
NG
6
0
)
-
L
-
FENCE LINE
C
0
P
THRUST ANCHOR
P
A
0
7
/
/
8
75
P
8
P
/
DRAWI
/
P
L
L
T
O
STA 0+081.98
L
/
G
2
/
L
/
8
T
/
/
/ TREE LINE
L
8" HRDH-611 F/L
L
C
H
0
0+
C
G
N
P
10
C
P
A
/
TRANSITION POINT -
C
1+
C
/
/
L
/
P
L
30
P
/
/
L
/
L
G
O
8
STA 0+069.97 BUSH, HEDGE, BRUSH AS NOTED
U
PLAN
L
P
/
-
L
K
W
T
L
P
8
C
P
R
G
T
R
/
IG
/
PT-1
/
START
S
R
100
C
A
L
SABKHAH
THI
K
L
L
P
O
/
P
IN
STA 0+269.28
/
STA8 0+064.99
W
L
PT-0 SUMP
C
E
O
T N 2708357.002
/
N 2708440.467
A
STREAMS
80
STA 0+165.17
L
D
P
/
E 307343.945 E 307523.494 - 8
FROM
N 2708418.855
L
8 0+085.76 POND
60
8
T E 307439.873 -
8
0+076.55
2000
8 0
2
0 WADI
40
P
{
o $ 1+
1:
o o
NED
8 8 { $
T
o
o
oo
$ PI-1 K
2 WELL OIL WELL OR WELL SITE
N 2708360.472 .4
SCALE
20
OBTAI
$ o
19 8.4
o 2
o
E 307516.171 8
4
o
|
2 TOWER
4
+
4
o T
P
o
F 1 E
°2
R=105.00m
0
E 8 C
N 8 3
m
3
8
C D=12°04'17.1" T 0 TRANSMISSION TOWER
0
ORT LED
'3
H
CAL
8
14"
E
1'
T
N
8
0
17°
ORT E
H
TRU
m
.
N
$
L=16.15m
6
0 3
BE
"
$
T=8.10m 0 0 BUILDING
3 0 0 6
P
K 0 m
3
T
$
SUMP 3
0
0
1+ 0 3
0 4
3 + -8 SIGNPOST
PART,SHALL
1+ 1 A
A T
1
$ 8
T
T
1 S G SURVEY MONUMENT/STATION
6
W
P
-
T E D
N
H
8
I E FULL THRUST ANCHOR
D
L E
R
H S
H
P
E T
K
M T
3 A
0
7 N
I
4
N
I
T
0
T
8 N
0
8
8
0
0F1 m
0 C
FULL,OR
7
P
3 3 3
7
0 0 0
R
0
2
7 7 7 WARNING SIGN
O W
7
F
N
2 4 6
2
2
0 0 0
0 0 0
N
N
EXISTING UNDERGROUND PIPELINE
K
P
EXISTING UNDERGROUND TELECOM CABLE
START AT A/G FLANGE
N
I
00
ANCHOR
DATA
1+300.
ON
71
67
00
16
0+079.
REPRODUCTI
0+062.
1+000.
CAMEL CROSSING (PROFILE)
STA.0+071.
AL
:NONE
MATERI
THRUST
BERM AT PLAN
STA
FENCE
STA
STA
STA
SCALE
NE
REVISION CLOUD
LI
&
SAUDIARAMCO.NO
MATCH
REVISION MARKER
PI
XXX
NOTE-2 PIPING PIPELINE
8.625" ODx0.344" WTH AP1 5L GR X65 SMLS
PIPE, EXT FBE COATED
REFERENCE DRAWINGS
NT
T)
FENCE
PAD
C/L
C/L
C/L
C/L
C/L
PC-2
PT-2
P/L
P/L
C/L
P/L
C/L
C/L
PC-3
P/L
PT-3
P/L
NE
ANCHOR
ROAD
ROAD
START
PC-0
PT-0
PC-1
PT-1
POI
(
ELEV ELEV
POWERLI
CABLE
m m
WELL
P/L
P/L
P/L
P/L
P/L
A/G
A/G
P/L
A/G
P/L
P/L
A/G
A/G
100
ON
G
RI
RI
TI
ZONTAL
THRUST
U/G
TRANSI
U/G
U/G
U/G
U/G
U/G
U/G
U/G
U/G
80
O/H
OF
HORI
PROPERTY
20m
40m
20m
70m
70m
2000
77m
77m
77m
04m
04m
17m
21m
45
42
75m
65m
78m
02m
67
71
03
28
89
76
47
34
76
34
74
99
48
70
26
74m
96
76m
37m
27m
39m
45m
81m
10
13
10
16
72m
41m
34
16
11
11
11m
92m
61
STA.0+085.
15
65m
18m
14
STA.0+495.
STA.0+062.
STA.0+067.
STA.0+079.
STA.0+098.
STA.0+253.
STA.0+269.
STA.0+355.
STA.0+359.
STA.0+404.
STA.0+445.
STA.0+460.
STA.0+478.
STA.0+529.
STA.0+532.
STA.0+672.
STA.0+925.
STA.0+936.
STA.0+943.
STA.0+955.
STA.0+342.
90m
STA.0+071.
STA.0+166.
STA.0+571.
40
STA.1+050.
42
ELEV. 310.
ELEV. 304.
ELEV. 310.
ELEV. 310.
ELEV. 310.
ELEV. 312.
ELEV. 310.
ELEV. 311.
ELEV. 311.
ELEV. 311.
ELEV. 311.
ELEV. 311.
ELEV.309.
ELEV.307.
ELEV.307.
ELEV.307.
ELEV.308.
ELEV.314.
ELEV.312.
ELEV.313.
ELEV.313.
ELEV.314.
ELEV.314.
ELEV.314.
ELEV.312.
STA.0+890.
STA.0+844.
STA.0+870.
1:
ELEV.312.
EXISTING
STA.1+226.
ELEV.306.
ELEV.307.
ELEV.301.
ELEV.303.
TOP OF BERM GROUND PROFILE
SCALE
20
900mm FROM
CUT EXISTING TOP OF
0F1 TOP OF PIPE
GROUND (TYP.) PIPE PROFILE
0
SOLE
315 315
LE
PROFI
THE
310 310
10
ARE
CAL
N
HEREI
6
305 305
200
4
1:
SCALE
0.6m (TYP.)
2
NED
SCALE: AS SHOWN
CONTAI
300 300
0
0+000
0+100
0+200
0+300
0+400
0+500
0+600
0+700
0+800
0+900
1+000
1+100
1+200
1+300
REVISION VALIDATION
THIS REVISION NO. 0F1 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
ON
10-02029-0003-000
NFORMATI
MATERIAL DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
SURVEY NOTES: (DESIGN AGENCY) x REQUIRED (SAUDI ARAMCO)
GENERAL NOTES:
ITEM QUANTITY0F1 DESCRIPTION 1. COORDINATES ARE UTM (ZONE 39) INTERNATIONAL (1924) 8. PROFILE WAS EXTRACTED FROM PHOTOGRAMMETRIC MAPPING
ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
MMB VKP
1 1237.33m 8.625" OD x 0.344" WTH API-5L GR X65 SMLS PIPE, EXT FBE COATED ELLIPSOID, AIN AL ABD 1970 DATUM IN METERS WITH A PROBABLE VERTICAL ACCURACY OF +/- 1M. 1. SEE NOTES IN DWG NO TA-843603.001 11/11/18 11/11/18
2 2 KILOMETER MARKER W/O TEST STATION PER STD DWG AD-036973 AND AB-036907 (1994 HORIZONTAL ADJUSTMENT). REV.NO. DATE REVISION DESCRIPTION
9. THE EXACT LOCATION OF ALL UNDERGROUND FEATURE ARE APPROXIMATE
I
2. CONSTRUCTION CONTRACTOR SHALL VERIFY THE ELEVATION AND EXISTING 0F1 11/11/18 RE-ISSUED FOR CONSTRUCTION
3 1 WARNING SIGN PER STD DWG AB-036891 2. ELEVATION DATUM IS SAUDI ARAMCO VERTICAL DATUM AS PER GSD. IT IS STRONGLY RECOMMENDED THAT THE EXACT LOCATION 0F1
FACILITIES OF STATION APPROACH PRIOR TO CONSTRUCTION, AS GSD DATA
THE
& ELEVATION OF THESE FEATURES BE VERIFIED PRIOR TO ANY JOB ORDER/EWO NO.
OF 1978 (SAVD78) 1994 ADJUSTMENT. FOR APPROACH LOCATION IS NOT AVAILABLE. THIS REVISION IS NOT TO BE USED FOR
CONSTRUCTION IN THE RELATIVE AREAS. 10-02029-0003 CONSTRUCTION UNTIL CERTIFIED AND DATED
3. DATE OF SURVEY: 0000 AERIAL PHOTOGRAPHY
3. THE KM MARKER WITH TEST POST ARE INDICATIVE ONLY, THE ACTUAL
10. ALL BURIED PIPELINES NOT FIELD LOCATED. LOCATION
SAUDI ARABIAN OIL COMPANY
AND
4. STATIONING IS GROUND DISTANCE IN METERS, CP DETAILS SHALL BE CAPTURED FROM CP DOCUMENTS / DRAWINGS.
SHOWN IS BASED ON CENTERLINE OF BERM. DRAWING TYPE
DIRECTIONS AND DISTANCES ARE GRID.
11. SOIL TYPES SHOWN ON THIS DRAWING ARE A GENERAL(1924)
PIPELINE ALIGNMENT PRF
4. CONSTRUCTION CONTRACTOR NEED TO FOLLOW THE COORDINATES
NG
5. GROUND DISTANCE X COMBINED FACTOR = UTM GRID DISTANCE.
DESCRIPTION OF SURFACE MATERIALS ONLY, PRF
PROVIDED IN THIS ALIGNMENT SHEET. COORDINATES OF FLOWLINE A/G 8" HRDH-611 F/L
DRAWI
6. COMBINED FACTOR = 1.000005936 0F1
DETERMINED BY VISUAL INSPECTION FLANGE IN THIS DRAWING ARE BASED ON SAUDI ARAMCO PROVIDED
7. ALL PLANIMETRIC FEATURES SHOWN IN LOW TONE WERE WELL HEAD CENTER COORDINATES.THIS COORDINATE SHALL BE FOLLOWED
GAS GATHERING MANFS. F/LINES
EXTRACTED FROM PHOTOGRAMMETRIC MAPPING WITH FOR CIVIL WORK, INCLUDING THRUST ANCHOR BLOCK AND PIPING DRAWINGS.
HARADH SAUDI ARABIA
A PROBABLE HORIZONTAL ACCURACY OF +/- 5M.
S
PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.
THI
DATE OF PHOTOGRAPHY: 0000
H91 A AA-843603 002 0F1
Saudi Aramco 2615 ENG. (05/05)