Sizing of relief valves (critical and two-phase flow) with isentro

From Properties editor define the composition, then enter the (initial) discharging temperature, pressure and flow with prop
the procedure calculates the isentropic chocked nozzle flux and the required area
Pin 68.9400 bar.a
Tin 313.0000 K
Pout 2.0000 bar.a
Flow 13000.0000 kg/h Result No errors
Stream 1
Ps Ts Hs Vs Mass Flow
bar.a K KJ/Kg m3/kg Kg/(m2*s)
54.064 302.751 5109.609 0.006 21559.713
52.412 301.396 5108.633 0.006 21906.671
50.759 300.003 5107.613 0.006 22147.797
49.106 298.569 5106.544 0.006 22294.147
47.453 297.093 5105.425 0.007 22355.002
45.800 295.572 5104.251 0.007 22338.156
44.147 294.003 5103.019 0.008 22250.182
42.495 292.384 5101.724 0.008 22096.657
40.842 290.711 5100.362 0.008 21882.326

Estimated tout (steady st.) 201.46919906 K


(Max, choked) Mass Flow 22355.00238 Kg/(m2*s)
Calculated area 1.61535 cm2
Corrections Ka*Kb*K… 0.87700
Required Area 1.84190 cm2

cp/cv calc. real @ tin,pin ideal @ tin,patm real @ tin,pin


cp/cv #MACRO? #MACRO? #MACRO?
Zv #MACRO? #MACRO? 1
C #MACRO? #MACRO? #MACRO?
Area #MACRO? #MACRO? #MACRO?
Error % #MACRO? #MACRO? #MACRO?