A1 Notes
A1 Notes
7.6 k
permission of McLeod | Bovell Design Inc. Contractors
17 ea
15 sill
porch
6'
7'
el. of p
8.2
shall verify and be responsible for all dimensions on the
el. oor
deck
ro
d
job and this office shall be informed of any
7'-11"
discrepancies and variations shown on the drawing.
bldg overhang
36'-3"
4 22-03-31 issued for client review
15
1 .20
driveway
15 15 15
4.2 4.0 2.8 OS01 adjacent adjacent
1 9 15 15
3
2.8 4
2 .6
15 3.0 el. 154.17' gutter 0.3' gutter 0.1'
9
15
3.1 0
9 15 15 onto Lot 18 onto Lot 18
15 2.4 1.4 15
9
2.4 1.2
2.0
0 6
7 8 9'-1 1/2"
15
15 15
3
hydro pole
4
27
2.7
15 1.1
15
4.0 15
2.1
15 5'-0" 101'-6"site length
2.4 52.
4.1 15
1.7
2.7
15
1 2.3 w/ overhead distr. 1
15
2.9
1
4
9
9
2
5
15
5
15
lam 15
9
3.3
1
1.2
0.2
0.1
3
1.4
2.3
1.8
EAST PROPERTY LINE 101.49'
p p 3.71
15
15
15
15
15
2
15
15
8
15
os
3.0 2.3 15 15
t
2.7 15
0
2 15
2.7
2.7
"
2 2.8
6
1 10D10
15
90°
4
45'
5
PL to concr. wall
el. 151.78'
PL to CLD
12'
89°
proposed gravel driveway (to be removed)
crossing to remain
45"
8
concrete sidwalk
2.6
stump to be removed
ex. driveway
PL to bsmt fdn
22'-9" 40'-1" proposed main/upper flr depth 38'-1 1/2" rear yard setback
15
9'-2 1/4"
proposed buried
gutter
cld to cld t.o. wall 151.0' t.o. wall 151.0'
12'-9"
8'-8 1/2"
9'-10"
hydro service
b.o. wall 150.78' b.o. wall 150.92'
el. 149.73'
ex. 150.78' ex. 150.92'
30'-4" PL to garage
15 concrete garden wall (non-retaining)
2.1 15
8 2.8 40'-11 3/4"
9
2'-10"
ext. deck
0
151.0' F el. 168'-9"
2.7
150.92' E b.o. wall 150.5'
15
151.20' E
cov 156'-2
27'-1 3/4"
el.
extent of bsmt 38'-9" rear yard limiting dist.
ere
6
9.1
PL to bsmt fdn RT02
d p 1/2"
8
el. 153.57'
25'-3"
14
PL to CLD / concr. wall
4
2.5
9.1
el. 151.64'
orc
CITY02
15
gutter
14
2
condenser
9.1
h
unit
neighbour's
14
14'-4" main house to garage 21'-6" acc. bldg depth 2'-10"
hedge on
t.o. wall 151.0' 4'-6
property
15 15 15 15 "
3.7 b.o. wall 151.0' 33'-4" bsmt fnd to fdn cld to cld / fdn to fdn
el. 1 amp
3.8 2.5 2.0 AUTOCOURT
"
51'-6
8 6 0 4 ex. 151.43'
r
b.o.
15 24'-2 1/2" 33'-2" proposed basement depth 3'-6" 34'-8 1/4"
6
2.7
5
2.3
9
)
PL to concr. wall cld to cld PL to concr. wall
extent of bsmt
15
e
15
slop
stump gas connection
8
%
3558 WEST 39TH AVENUE
9.2
el. 154.26' 0.8m below
(10
14
9013 (to be removed)
el. 149.54'
LOT 18, BLOCK 14,
mp
8
RT03 151.08' F
9.2
e ra
14
el. 151.64' 149.28' E
9'-2 5/8"
cret
8
6"
con
9.2
29'-
3558 West 39th Avenue
14
46'-2"
65.96'
150.4' F 150.31' F
fdn to fdn
Vancouver
cld to cld
water connection 3'-0" 6694 sq.ft lot area 150.84' E 150.31' E
pressure: 77 psi 40mm ø water pipe Zoning : RS-5
2"
t.o. parapet el. 180'-9"
d +4
sanitary & storm 100mm ø sanitary pipe ACCESSORY BUILDING
2"
upper floor el. 168'-9" REAR DECK
rd +4
2 CAR GARAGE
guar
min./max. depth (invert el.) = 44.98 m / 147.57’ main floor el. 156'-9" el. 156'-9"
14
bsmt floor el. 145'-9" stump
a
45'-10" proposed main flr width
8.9
sanitary to be east of storm pipe; 151.0' F
l
meta
r. gu
gravel flat roof
9
2"
el. 149.86'
31'-6" [9.6m]
d +4
t.o. parapet el. 161'-7"
conc
Basement Area 1,067 sf
5
to be removed
2.3
+42
uar
15
Main Floor Area 1,333 sf
ard
15
46'-2"
15
3
2.2 1.8
2.2
u
15 Garage Floor Area 452 sf
con
al g
5 6
15
3.3
extent of basement
9 Total Floor Area 4,085 sf
met
2.3
4'
15
1.9
t.o. concr. landing
15
t.o. landing
el. 153.26'
15
2.5
2R@6"
3.4
15
ramp
15 7
8
3
151.0' F
LOT 27
2.1
4
2.2
UP
2.2
7
15
15
151.20' E 150.4' F
el. 152.23'
5
9.1
operable operable 150.59' E
14
RT01 skylight skylight
el. 151.94' RT05 No. Date Appr Revision Notes
el. 1 amp
el. 150.59'
"
1 22-06-10 BP AMENDMENT
56'-9
22'-7" FY limiting dist. (PL to CLD) t.o. wall 151.0' 149.55' F
t.o. r
(front yard setback) RT04
b.o. wall 150.9'
3'-0"
el. 150.59' 149.55' E 2 22-06-24 BP AMENDMENT 2
1
8.3
concrete garden wall (non-retaining) ex. 151.02'
14
3 22-08-19 BP AMENDMENT 3
el. 153.18'
t.o. wall 151.0' 151.0' F metal guard +42"
CITY01
b.o. wall 151.0' 151.31' E 149.73' F
14
ex. 151.5' 22.57' 40'-7" (40%) 38'-3 3/4" 14
el. 148.76'
6
8
PL to bsmt fdn
FYA
PL to concr. wall
PL to CLD
90° 25'-11" max depth of acc. bldg
12'-10 5/8"
10D12
14' 9011
9'-10 3/4"
7"
22" 9010
gas main
4
el. 149.70'
7'
15 el. 150.67'
°4
1.6 15 (to be removed) to be removed stump
89
8 2.2 15 hedge to be retained
0
15 15 15 trunk 0.1 clear of Lot 19 el. 149.82'
8.6
3.3 2.0 4 2.0
3.4 8 where it affects neighbour
14
2 2 to be ground
1 LP
WEST PROPERTY LINE 14 14
IP hedge to be retained 9.3
2
15 9.6
8
8
9.8
5
9 .4
9.3
1 .3
7
2.2
2.2
101.45' 8 5
1.9
CITY03 where it affects neighbour
14
14
14
15
5
15
23'-10 1/4" 15'-10 3/4" 5'-0" 76'-11"
15
el. 153.52' 15
1.5 PL to garage OS02
6
9
5
2.0
9.0
149.29'
15
14
15 15 14 14
2
15 14 9.2
1.3
1.9 2.0 9.6
2
2.2 9.3
1.7
0
5
15
6
2.0
5 2
2.1
15
4
0
5
15
3.3
2.2
3.2
15
1
15
0.1
15
15
stairs
7
2.2
2.4
6
1.9
15
1.6
15
15
15
14
15
15 14
2.0 9.7 9.2
20'-3 1/4" 0 2 5
driveway
36C22
el. 147.74' 293 Columbia St
14
8.0 Vancouver BC V6A 2R5
3566 WEST 39TH AVENUE 8 3565 WEST 40TH AVE.
driveway driveway deck
15 LOT 19 LOT 26
2.1
2
15
1.9
N
3
1.6
15 1
15
1.9
5
15 15
2.6
ro 179
2.0 20'-1 7/8"
of .9
el.
9 0
pe 0'
ak
Project Title
3558 WEST 39TH AVENUE
do 57.7
el.
28'-10 1/4"
or 9'
1
sil
VANCOUVER, BC
l
Public Sewer and Water Connection Information V6N 3A5
(Provided by CoV Engineering)
deck scale drawn by
Sanitary/Storm Min. Depth Invert Elevation = 44.98m (147.57') as indicated TY
Sanitary/Storm Max. Depth Invert Elevation = 44.98m (147.57') date reviewed by
Fixture Restrictions: 22-08-19
All sanitary fixtures (including floor drains) with rim elevations project code status
below 46.436m (geodetic) or 152.349' (geodetic) must be 39TH CD
protected. (see "Fixture Restriction Guidelines Update")
Site Plan
A0.02