Identifier 1: Ar301 - Tviii Architecture and City 3/16" 1'-0" First Floor
Identifier 1: Ar301 - Tviii Architecture and City 3/16" 1'-0" First Floor
IDENTIFIER 2 52
53
EVACUATION SYSTEM AND FIRE SAFETY
Indicator: SC.6 System Integration
H
54
Applicable Standard: IBC 2021, Chapter 10,
08 09 10 11 12 13
Section 1006.2 (Evacuation Route and Maximum 01 02 03 04 05 06 07 14 15
16 17 18 19
55
Distance Requirements).
56
Plan Reference:
The design includes multiple evacuation routes
57
connected to main exits, complying with the F
maximum distance of 20 feet from any point
within the larger spaces. Emergency doors open 58
104
35.00
102 General
02
Warehouse 60
Justification: Reception 105
188.30 ft²
2444.20 ft² Descharge
These measures ensure occupant safety during 01
103
571.10 ft²
G
61
an emergency, complying with evacuation
RA
16'-6" Electrical 06
N
Room
D
regulations. Furthermore, the architectural 10'-3"
ST
286.10 ft²
62
A
106
N
planning considers ergonomic and functional 05
Service 08
D
aspects, integrating accessible and safe routes.
E 30
32 34
Hall
240.10 ft² G
118 04
63
Public
Computer
Room
22.15
6
Store 101
5
Room
120
4
442.90 ft² Hall 258.60 ft²
BA
Cafeteria
2
2127.80 ft²
1
569.25 ft²
SK
10
28
28 31 HVAC HVAC
'
33
ET
RAINWATER HARVESTING SYSTEM D
28
11
A
12
28
Atrium Multipurpose 112 Multipurpose Women's
.0
21 18
HVAC
Room 1 Foyer
0
25 153.00 ft² Room 2 13 Bathroom
The plans show strategically located drains on the
h
nc
be
l
1661.20 ft²
na
793.40 ft²
tio
op
na
tio
op
27
"
tu
1'-6
5)
(.45
a
eler
Nonbinary pap
28
Men's Bathroom
.0
430.60 ft²
0
This system promotes sustainability by reducing B
the reliance on potable water for non-essential 80
1'-6 5)
(.45
"
F
pap
resilience to local climatic conditions and 113
eler
D
a
A
12
B
C
MultipurposeYard
27.00
22 17 ir e
resources.
28
Deposit
.0
F
1'-6 5)
(.45
D
"
pap
Art Galery Multipurpose
ele
0
ra
351.85 ft²
A
C
Dep. Dep.
434.75 ft² 434.75 ft²
15
IDENTIFIER 4 A ir e
in ha c
m elc spa
60 he g
W rnin
13
tu
NP
T
.+
0.8
HVAC and Ventilation on the First Floor
0
NP
T.+
A
0.4
0
Indicator: SC.6 System Integration.
Reference on the Plan:
1 2
3
2
1
The HVAC systems are strategically located in
central positions, minimizing duct runs and
Tennis
NP
T
.+
0.4
0
ensuring uniform air distribution in the main areas.
NP
T.+
0.4
0
NP
Architectural Justification:
T.+
0.8
0
The HVAC system planning ensures energy
1
2
efficiency and thermal comfort for users. The
3
central location allows for optimal air conditioning
NP
T.+
0.8
NP
0
T.+
NP
0.4
T.+
distribution without interfering with the interior
0
0.4
0
layout. By integrating vertical ducts into structural
3
2
1
architectural design are avoided, maintaining a
clean and functional aesthetic. This technical AR301 - TVIII ARCHITECTURE AND CITY N JONES-VARGAS 3/16" = 1'-0" 03-12-2024
solution not only maximizes energy performance
but also enhances occupant comfort, efficiently
meeting climate control needs in a discreet COMMUNITY SPORT CENTER SAN ANTONIO, TEXAS YURI MORIN- SAMANTA MARTINEZ
AR8
FIRST FLOOR
A-02
manner.