The document outlines the different application types available in FactoryTalk View SE, including Network Distributed, Network Station, and Local Station applications. Each type has specific features, licensing requirements, and architecture configurations, such as client/server setups and redundancy options. It also includes a disclaimer regarding the information provided and its intended use.

Uploaded by

chinitomelian
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
236 views5 pages

FactoryTalk View SE - Application Types

The document outlines the different application types available in FactoryTalk View SE, including Network Distributed, Network Station, and Local Station applications. Each type has specific features, licensing requirements, and architecture configurations, such as client/server setups and redundancy options. It also includes a disclaimer regarding the information provided and its intended use.

Uploaded by

chinitomelian
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

ID: IN7197 | Access Levels: Everyone

FactoryTalk View SE: Application Types

Document ID IN7197

Published Date 05/26/2022

Summary
FactoryTalk View SE: Application Types

Content
Features of and differences between FactoryTalk View SE application
types.
Available FactoryTalk View SE application types are:
• Network Distributed
• Network Station
• Local Station.

The last option is for Machine Edition (ME) applications. When opening FactoryTalk View
Studio you will see the following window:

For further details,


Cookie see the
blocking FactoryTalk
is currently View Site Edition installation Guide, Publication
enabled

Number To receive the best experience please enable functional cookies in the OneTrust cookie
VIEWSE-IN003
settings.
Network Distributed applications

• Client / Server architecture (multiple Client and Server computers)


• More than one HMI Server
• Multiple Clients
• Redundant HMI servers
• Redundant Data servers

This type of application allows running Client / Server architecture (with multiple Client
and Server computers), which can be both local and remote. Allows for HMI Server and
data server redundancy. Data server can also be local or remote.

In short, the software programs behind a network distributed application - the FactoryTalk
Network Directory, HMI Servers, HMI Clients, and data servers - can be located on different
computers on the network; however, all the computers participating in a network
distributed application must point at the same Network Directory.
This application can be edited from the HMI server, or another remote computer that is
connected to the same Network Directory with FactoryTalk View Studio installed.

Licensing required:
• Each HMI Server requires FactoryTalk View SE Server license
• Each Client computer requires FactoryTalk View SE Client license
• Each programming workstation requires FactoryTalk View Studio Enterprise
Cookie blocking is currently enabled
To receive the best experience please enable functional cookies in the OneTrust cookie
settings.
Network Station applications

• One HMI server and one client on the same computer.


• FactoryTalk Directory Server, FactoryTalk Linx Data Server and the OPC Data Servers
can be located on remote computers.
• Redundant Datas servers supported

This type of application allows for Client/Server architecture as well; however, you can
have only one HMI server, but multiple local Clients. This is by all means a local
application, but it can connect to a network directory - meaning it is a local application
that can access data from remote computers, including FactoryTalk Historian and
FactoryTalk Transaction Manager.

In short, the HMI server and the HMI client are the software programs behind a network
station application that must be located on the same computer. The FactoryTalk Directory
Server, the FactoryTalk Linx data server, and the OPC data servers can be located on
remote computers. HMI redundancy is not supported in this application type, however,
data server redundancy is supported.

In FactoryTalk View SE v7.00, the application can be edited from the HMI server only with
FactoryTalk View Studio installed.
From FactoryTalk View SE 8.00, the application can be edited from any remote PC that is a
part of the same FactoryTalk Directory with FactoryTalk View Studio installed.

Licensing required:
• FactoryTalk View SE Station license for the machine containing HMI Server and Client
• Each programming workstation requires FactoryTalk View Studio Enterprise
Cookie blocking is currently enabled
To receive the best experience please enable functional cookies in the OneTrust cookie
Local Station
settings. applications
• One HMI server and one client on the same computer.
• Factory Talk Directory Server, FactoryTalk Linx Data Server on the same computer as
the HMI Server.
• OPC Data Servers can be located on remote computers.

This is a purely local application. All servers and client run on one computer. There is no
remote connectivity. This is all contained on only one PC.

In short, the software programs behind a local station application—the FactoryTalk Local
Directory, the HMI server, the HMI client and the FactoryTalk Linx data server—must be
located on the same computer. Only OPC data servers can reside on remote computers.

This application can be edited from the HMI server, or moved to a remote PC with
FactoryTalk View Studio. Once modifications are made, it must be moved back to the HMI
server.

Licensing required:
• FactoryTalk View SE Station license for the machine containing HMI server and Client
• Each programming workstation requires FactoryTalk View Studio Enterprise

Recently Viewed

What is FactoryTalk Unable to specify Licensing Limit for


View SE Network FactoryTalk Network FactoryTalk Network
Station Directory Location Manager
Cookie blocking is currently enabled
To receive the best experience please enable functional cookies in the OneTrust cookie
settings.
DISCLAIMER
This knowledge base web site is intended to provide general technical information on a particular subject
or subjects and is not an exhaustive treatment of such subjects. Accordingly, the information in this web
site is not intended to constitute application, design, software or other professional engineering advice or
services. Before making any decision or taking any action, which might affect your equipment, you should
consult a qualified professional advisor.

ROCKWELL AUTOMATION DOES NOT WARRANT THE COMPLETENESS, TIMELINESS OR


ACCURACY OF ANY OF THE DATA CONTAINED IN THIS WEB SITE AND MAY MAKE CHANGES
THERETO AT ANY TIME IN ITS SOLE DISCRETION WITHOUT NOTICE. FURTHER, ALL
INFORMATION CONVEYED HEREBY IS PROVIDED TO USERS "AS IS." IN NO EVENT SHALL
ROCKWELL BE LIABLE FOR ANY DAMAGES OF ANY KIND INCLUDING DIRECT, INDIRECT,
INCIDENTAL, CONSEQUENTIAL, LOSS PROFIT OR DAMAGE, EVEN IF ROCKWELL AUTOMATION
HAVE BEEN ADVISED ON THE POSSIBILITY OF SUCH DAMAGES.

ROCKWELL AUTOMATION DISCLAIMS ALL WARRANTIES WHETHER EXPRESSED OR IMPLIED IN


RESPECT OF THE INFORMATION (INCLUDING SOFTWARE) PROVIDED HEREBY, INCLUDING THE
IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, AND
NON-INFRINGEMENT. Note that certain jurisdictions do not countenance the exclusion of implied
warranties; thus, this disclaimer may not apply to you.