You are on page 1of 107

IRRIGATION OUTLETS

An outlet may be defined as a hydraulic


structure at the head of water course
which connects it with a supply canal. The
supply canal is usually under the control
of an irrigation authority. The authority
may be a Government department, a
public, or semi-public organization. Thus
the farm outlet is the connecting link
between the canal operator representing
the authority and the farmer or user.
Non- modular outlet
It is the outlet in which the
discharge depends on the
difference of water levels in the
supply canal and watercourse.
Semi-Modular outlet
It is the outlet in which the
discharge is independent of water
level in the water course but
dependent on the water levels in
the disrtibutary
Modules
It is also called Modular outlet or
Rigid Module. It is an outlet in
which discharge is independent of
the water levels in the distributary
and the water course
Outlets of Punjab

•Total number of outlets in the Punjab are


50,000.
•Out of these, more than 75% are A.O.S.M,
20% are Open Flume and 5% are Pipe or
Scratchley type Outlet.
•A.O.S.M is commonly used, Open Flume
Outlet are used in the tail reaches While
Pipe or Scratchley are used when other
types can not be used.
Crump‘s Open Flume Outlet
Adjustable orifice Semi-Module
Pipe Outlet

Figure No. 2.19


Submerged pipe outlet
Scratchley Outlet

Figure No. 2.20


Scratchley outlet
Characteristics of Outlets
 Flexibility :The capacity of an outlet to vary
its discharge with a change in the discharge of
the distributary is called flexibitity. It may also
be defined as the ratio of the rate of change of
outlet discharge to the rate of change of
discharge in the parent channel
 F = [dq/q] / [dQ/Q]
Sensitivity

 This is defined as the fractional increase or


decrease of module supply per rise or fall in
channel surface. It may also be defined as the
ratio of the rate of change of discharge of an
outlet to rate of change in the level of
distributary water surface
 S = (dq/q)/ (dG/D)
Efficiency

This is defined as the ratio of head recovered to


head put in.
In case of weir type outlet efficiency is same as
the drowning ratio.
Drowning ratio = (Height of water above the
crest d/s) / (Height of water above the crest
u/s).
Minimum Modular Head

 The necessary minimum difference of


water level or pressure between
supply and delivery sides to enable a
Module or Semi-Module to work as
designed.
Coefficient of Discharge

 In order to use the outlet as measuring


device the C. d should remain constant in
full Modular Range. For a weir type Semi-
Modular outlet the one with along throat is
better than with a short throat, since the C.
d may increase with the head in the latter
and is uncertain in value.
Silt drawing capacity

 It is vital that the outlets draw their fair


share of silt. This avoids silting or scouring
and consequently remodeling of the
distributaty. In a distribution system the
absorption losses are generally taken as
10% and therefore the silt conducting power
of outlets should be around 110% as
compared to 100% of the distributary to
enable them to draw their proportional
share.
Ajustability

 The adjustment of Modules may range from


complete reconstruction to the provision of
some mechanical arrangements by which
readjustment can be made at little cost i.e in
the case of Crump's A.P.M it can be adjusted
by lowering or raising a roof block at little
cost.
Setting of an Outlet

 (H/D) is known as the setting of an


outlet and for an open flume outlet to
behave proportional the head over the
weir H must be 0.9 D.
 Similarly for an orifice type outlet, H
would be 0.3D for the module to be
proportional.
Open Flume Outlet

 There are various types of outlets,


varying in certain details but the basic
principle remains that of producing a
super critical flow and allowing for the
formation of hydraulic jump to make
the discharge independent of the level
in the watercourse.
Flexibility
 It will thus be seen that proportionality in
discharge can be secured by fixing the crest of
the outlet at 0.9 of the depth of the supply
canal. If the crest be higher than this, the
outlet become more flexible
 To decrease the defect of high flexibility, a roof
block is fitted in the filled of an open flume, at
the vena contracta, clear of the water surface
in the gullet when the outlet is drawing its full
supply discharge
Flexibility (continued
 This clearance is set at 1.5 cm in the head
reach and 3cm in the tail reach of the
distributing canals. The roof block should be
fixed at a distance equal to H(Crest) below the
upstream end of he throat and the bottom the
roof block should be at a height of 0.75
H(Crest) above the crest plus the clearance of
1.5 cm to 3 cm. The roof block should have a
square edge at the bottom and it may be of
brick masonry or reinforced concrete, the
height up to the top of the side walls and
length along the flow varying from 12 cm to 23
cm.
Silt drawing capacity
Higher the crest with respect to the channel bed
the lower is the silt drawing capacity. Therefore,
it is desirable to have a lower crest, which also
suits flexibility requirements, but hydraulically
this may not be possible and the crest has to be
kept much higher to meet the discharge
requirement. For example for a 3 ft deep cannel,
a 0.2 ft wide outlet if placed at the bed would
pass a minimum discharge of 3.01 ft3/sec. This
means that if it is desired to reduce the discharge
further to the normal 2 ft3/sec or less, then H
has to be reduced or the crest has to be raised.
 The working head (i.e. M.M.H) required is small
which is 10%-20% of the depth of water above
the crest. If the outlet has a higher setting,
these outlets can work with a small fraction of
H.
 This is a good proportional distributor of water
and hence most suitable for tail clusters.
 Silt drawn can be controlled by modifying the
intake of the outlet.
 If the setting is kept below 0.9D then it tends
to be sub-proportional (which is desirable) and
draws its fair share of silt.
Design formula

 The design formula used for an open flume


outlet is
 q = K × B(t) × H(Crest)
 B(t) = width of the throat in cm or ft (throat
width less than 6 cm or0.22 ft must not be
adopted
 K = 2/3 cd.√2g= coefficient.
 C.d. = coefficient of discharge
 K has the following values for different widths
of throat ( in metric and British units)
 B(t) cm K
 6 to 9.0 16
 9.1 to 12.0 16.24
 over 12.0 16.53
 0.2 to 0.29 2.9
 0.3 to 0.39 2.95
 0.40 and over 3.00
Designing procedure

 The minimum modular head adopted is


0.2H(crest) when designing, it is
necessary to assume a particular value of
B(t)or H(crest), then calculate the other,
and work out the minimum modular head,
and then see if the latter is less than the
available Working head. To find B(t)or
H(crest) for a given discharge and a
working head, figure (2.11) may be used.
Example 1: Design an open flume outlet
with a discharge of 50 liters per second, for
a canal with a full supply depth of 100 cm.
The working head available for the outlet is
15 cm.
 Solution
q = 50 litres/sec D = 100 cm H(wk) = 15 cm
( as H(wk)min = 0.2H = 0.2×100= 20 cm)
 H(Crest) = 100 - 20 = 80 cm

 With H(Crest) = 80 cm and q = 50 l/sec

 The width B(t) will be 4.8 cm, i. e less than 6 cm.

 So, Adopt minimum value of B(t) = 6 cm

 H(Crest )= 64.73 cm (from figure 2.11)


Fig-2.11
 for which
 H(wk) min = 0.2 H(crest) = 0.2×
64.73 =12.946 cm
 Against 15 cm available.
 The design is suitable but setting of
the outlet is 64.7/100 = 0.647
 This is not too high but the outlet will
not take its fair share of silt.
 Should it be necessary to conduct silt
effectively it is possible, though costly,
to build a combined and open flume
outlet.
Example 2: Assume the outlet in example
1 is located just above or within a short
distance of a fall or drop in the canal which
has a depth over crest under full supply
condition of 50 cm. Let the available working
head of the outlet be 70 cm. Design a suitabl
outlet.
Longitudinal Cross Section

Figure 2.5 Jamrao Type Orifice Semi-Module


Figure No. 2.7 Gibb’s module
Figure 2.6 Jamrao Type Orifice Semi-Module
 Solution: Since the outlet is above or close
to a control point in the canal, H (crest) of
the open flume outlet should be the same as
that of the fall, viz: 50 cm. This will ensure
proportional distribution.
 Thus q= 50 l/sec H(crest) = 50 cm.
 B(t) = 8.84 cm ( from fig No5-18)
 H(wk) = 70 cm
 H(wk)min =0.2 H(crest ) = 0.2×50 =10 cm
 Which is much less than the available
working head.
Example 3
 Design a three-way tail cluster open flume
outlet in accordance with the following
data .
 Tail right outlet: q = 50 l/sec
and H (wk) = 12 cm
 Tail Centre outlet: q = 80 l/sec
and H(wk) = 30 cm
 Tail left outlet: q = 30 l/sec
and H(wk) = 15 cm
 The full supply depth of the distributing
canal at the tail is 40 cm, and full supply
depth is 100 cm
SOLUTION
 An examination of the available working heads of
the three outlets shows that if H(Crest) be 30 cm,
all the outlets will work modularly .
 H(wk)min = 0.2 H(Crest) =0.2× 30=6 cm
 Tail right outlet q = 50 l/sec
 H(Crest )= 30cm
 B(t) = 18.3cm ( from figure 2.11)
 Adopt crest level= 99.64 m (axis assumed parallel
to flow in supply canal
 Tail centre outlet) q = 80 l/sec H(Crest )=
30cm B(t) = 29.3 cm
Figure-2.11
 ( from figure 2.11)
 Adopt crest level = 99.70 m
 Tail left outlet
 q = 30 l/sec H(cres)=30 cm
 B(t) = 11.2cm ( from figure 2.11)
 Adopt the crest level = 99.64 m
 The crest of the central outlet with its
axis parallel to the flow in the supply
canal will be 0.06 m higher than the
other two or three side outlets.
Example 4: Design an Open Flume Outlet
for proportional distribution in a supply
canal, the normal supply of which is 55%
of the full supply.
 D = 120 cm, q = 45 l/sec, H(wk) = 55 cm
 As H(wk) is more than 0.42D i.e. 50.4 cm, the
open flume will draw proportional discharge
from 55% to 100% of the supply in the main
canal.
 H (crest) = 0.9D = 0.9× 120 =108 cm.
 B(t) = 2.51 cm (from figure 2.11)
 Since B (t) = 6 cm,
 The value of H(crest) = 60.3 cm (from
figure 2.11)
Adjustable Orifice Semi-Module
(AOSM)
 Structurally, the AOSM may be regarded as a long
throated flume with a roof block capable of vertical
adjustment in the upstream end of the parallel throat
as shown in figure (2.12) &(2.13). The upstream face
wall or upstream wing wall on the supply canal is
curved and flared, the curvature ending 7.5 cm
upstream of the start of the crest. The downstream
face wall or downstream wing wall on the supply canal
is set forward inside the canal by a distance, which is
generally equal to q/Q (B+ D/2).
 Setting forward should only be done when the
bed width of the canal is reduced below the
outlet, keeping the down stream wing wall at
the down stream end and the upstream wing
wall upstream toe slope. The length of the
parallel throat is 60 cm (2 ft) for all cases.
There is no horizontal crest portion of the
throat and a glacis sloping at 1 in 15 starts
right from the upstream end of the parallel
sides of the throat.
Roof Block

 The roof block may be of cast iron but is


generally of reinforced cement. The face of
the roof block is set 5 cm from the starting
point of the parallel throat. It has a lamniscate
curve at the bottom with a tilt of 1 in 7.5 in
order to converge the water instead of a
horizontal base which would diverge it. The
cast iron roof block is 30 cm thick. The parallel
throat has a cast iron bed and check plates.
Side walls

 The side walls down stream of the


throat are given a splay of 1 in 10, i.e
up to 150 cm (5ft) after which they
are straight up to a length depending
on the bank width.
Flexibility
 This type of outlet is instantaneously
proportional when the bottom of the roof
block is at 0.3 of the full supply depth of the
supply canal. With a rise in the full supply
level the flexibility which is equal to
3/10×D/H(crest) , is reduced and the outlet
becomes sub-proportional. Similarly with a
fall in the full supply level the flexibility is
increased and the outlet becomes hyper
proportional.
Flexibility
 When the outlet is set near the bed level, with
any rise in the full supply level, the value of D /
H(crest) ,falls and the outlet tends to move
further from proportionally in the direction or
rigidity. A fall in the full supply level similarly
increase the flexibility and the outlet moves
towards proportionality. With the outlet set at
bed level the flexibility remains constant at 0.3.
Silt drawing capacity
With the improvement in the approach
conditions of the upstream wall the silt
drawing capacity is increased by 7-8% over
the crump’s APM. The silt drawing capacity
also increase with a deeper setting and the
following results have been observed.
6/10 setting 99.5%
8/10 setting 109.7%
10/10 setting 113.7% to 121.9%
So, this outlet draws at bed level about 14 %
and below bed level at 12/10th setting about
29% more silt than it would draw at 6/10th
setting when it is proportional.
Range of operation
It can work semi-modularly for all
discharges from 28 l/sec to 150 l/sec i.e.
the discharge range generally required for
outlets.
 Minimum Modular Head

 Gulhati has derived an empirical formula


for the minimum modular head
 Hm = 0.83 Hs - 0.5 Bt
 Efficiency
 As per efficiency is = J / Hs
 Where J and Hs are shown in fig .
 J = Height of hydraulic jump.
 Y = Conjugate on upstream side of hydraulic
jump.
 J+Y = conjugate depth d/s side of the jump.
 Conjugate depth d/s of jump = - Y/2 +√y2/4
+ 2v2/g × Y
 J+y = - Y/2 +√y2/4 + 2v2 Y/g
 J = - 3Y/2 +√y2 /4 + 2v2Y/g
 J= - 3Y/2 +√y2 /4 + 4 HsY (2.11)
 Khosla has derived the above formula
 E = j/ Hs in the following form ignoring
friction.
 Dividing (2.11)by Hs and putting Hs /Y = R
 = Depression ratio.
 J/ Hs = E = - 3y/2 Hs + (√y2 /4 + 4 Hs Y )
×1/Hs
 J/ Hs = E = - 3/2R+ (√y2 /4 Hs2+ 4 Y /Hs)
 J/ Hs = E = - 3/2R + (√1/4R2 +4/R)
 J/ Hs = E = - 3/2R + (√1+16R /4R2)
 J/ Hs = E = - 3/2R + (√1+16 R) /2R
 E = [(√1 +16R)-3)] / 2R
 If R = ½ =Hs/Y
 Then
 E = 3-3 =0 or j = 0
 Therefore there will be no jump formation
and the outlet will cease to perform as
semi-module.
 Adjustment
 The outlet is easily adjustable at a small cast,
either by raising or lowering the roof block or
by dismantling one side wall.
 Tampering
 The roof block is raised bodily and refixed but
the tampering is easily detected.
 Design formula
 (According to crump)
 q = K× B(t) ×√ H (sof)
 Where
 K = constant
 K = c.d √2g
 c.d= 0.62
 H(sof) = H (crest) - H (ori) = height of the
full supply level in the supply canal above the
bottom of the roof block .
 Also, M.M.H = 0.82 H (orf) - 0.5 B (t)
 It should be noted that recent research carried
out on the A.O.S.M in Pakistan has shown that
c. d varies with the throat with of the structure
i.e with the ratio D/ H(rest) and D/ B(t).
 Consequently the structural shape of the outlet
differs slightly from the design presented here.
EXAMPLE:

 Design an orifice semi - module having


a discharge of 60 l/sec on a canal with
full supply depth of 90 cm available
working head is 54 cm.
 Solution
 q = 60 l/sec
 D = 90 cm
 H(wk) = 54 cm.
EXAMPLE (CONT…)

 If it is desired that the orifice semi-module


should be proportional then
 H(crest) = 0.6 D = 0.6 × 0.9 = 54 cm
 An examination of the curves of (fig 2.14)
shows that for B(t) = 6 cm and q = 60
l/sec
 H (crest) must be more than 54 cm.
 For B(t)= 12 cm (Fig 2.17 ) the intersection
of H(crest) = 54cm and Q = 60 l/sec gives
H(crest) = 54 cm and q=60 l/s gives
EXAMPLE (CONT…)

FIG. 2.17
EXAMPLE (CONT…)
 H(orf)=21 cm
 H(sof) = 54-21=33 cm
 H(wk)min = 0.82 H(sof) - 0.5 B(t)
 = 0.82×33 - 0.5×12 = 21 cm
 The setting being 0.6 D, the outlet is likely its
draw its fair share of silt. For canals carrying
clear water the setting at 0.6 D is ideal for
proportionality.
 For rigidity and better silt drawing capacity,
the outlet should be set at bed level, viz
H(crest) = 90 cm
 From ( figure 2.17 ), with B(t) =12 cm and q=
60 l/sec
 H(orf) should be 14.2 cm
EXAMPLE (CONT…)

 H(sof) = 90 - 14.2 = 75.8


 H(wk)min = 0.82 H(sof) - 0.5 B(t)
 = 0.82×75.8 – 0.5× 12
 =56.1 cm > H(wk) = 54cm
 It is,therefore, necessary to reduce H(sof)
 An inspection of (fig no 2.14) shows that
with B(t)=7.5 cm and H(crest)=90 cm
 For a discharge of 60 l/s
 H(orf) should be 24.5 cm
 And H(wk)min=50 cm < H(wk) = 54 cm
EXAMPLE (CONT…)

 Another suitable size is


 H(orf) = 33 cm and B(t) = 6 cm
(figure 2.14 )
 With H(wk)min = 45 cm
 Should the working head be very low
and no suitable size of orifice semi-
module with a reasonably deep setting
can be designed, it would be
necessary to resort to another type of
outlet such as a combined pipe and
semi- module.
EXAMPLE (CONT…)

FIG. 2.14
Example

 An orifice semi-modularly is found to


be working working non-modularly
during an inspection of an outlet. The
actual working head on measurement
is found to be 30 cm. How can the
outlet be adjusted to give its design
discharge?
EXAMPLE (CONT…)
 Solution
 q = 60 l/sec
 H(crest) = 90 cm
 H(Orf) = 29.5 cm
 B(t) = 6 cm
 (fig 2.15 ) shows that for the given data,
 H(wk)min should be 47 cm against only 30
cm actually available.
 The first immediate remedy is to clear silt
from the water course if possible, and to
increase the available head to 47cm. If this
is not possible, then the roof block may be
raised so that the orifice working under
submerged conditions gives the requisite
discharge, which can be calculated roughly
by adopting K = 0.0354 in the formula
EXAMPLE (CONT…)

q = K× B(t) H(orf) √H(wk)

FIG. 2.15
EXAMPLE (CONT…)

 If neither of the two alternatives are


possible, it is essential to provide a
temporary outlet to supplement the
discharge of the existing outlet.
 The final remedy lies in redesigning the
outlet with H(crest) = 75 cm and H(orft)
= 36.5 which gives
 h(wk)min = 29 cm
 This would involve raising the crest of
the outlet by dismantling one side wall.
PIPE OUTLET
 General
 The pipe outlet is the simplest and oldest
known type of outlet. Originally the pipes
were of earthen ware but were gradually
replaced in most places by rectangular
wooden and masonry barrels. Cast iron,
steel and concrete pipes were progressively
introduced at later stages.
 This outlet can be built as free fall type if
sufficient head is available. It is generally
used where the silt charge is low and the
canal is running in high filling. When the
head available is very small, the submerged
pipe outlet is the obvious choice.
PIPE OUTLET (CONT…)

 Structural and design characteristics


 The pipe outlet consists of an up stream head wall;
a pipe and a down stream head wall. In a
submerged pipe outlet figure (2.19), the upstream
end is a little above or sometimes below the bed
level depending upon the designed silt drawn. The
other end of the pipe opens into the farm water
course below the water surface levels. The pipe can
be placed horizontally or sloping slightly up at 1 in
12 down streams. Both ends of the pipe are built
into masonry to present tampering and to guard
against any leakage along the outer side of the pipe.
PIPE OUTLET (CONT…)
 The free fall outlet may have a horizontal pipe
with its downstream end about the water
surface level in the water course but in that
case it can not, usually draw its fair share of
silt. In an attempt to fix the pipe at the bed
level of the supply canal and yet obtain free fall
conditions (where levels permit), some pipe
have been laid with their upstream ends at bed
level of supply canals and sloping upward
through the banks so that the downstream lips
reach a height 15 cm above the highest water
level in the water course. There are practical
limits to the amount of slope that can be given
and it should not generally be more than 1 in
12 (based on experience on the western
yamuna canal)
PIPE OUTLET (CONT…)

Hydraulic characteristic
 Silt drawing capacity
No results of comprehensive experiments
on the silt drawing capacity of pipe outlets
appear to have been reported, but such
experiments would be useful. On the
other hand, according to experience so far
canals fitted with pipe outlets at bed level
seldom give any silt trouble.
 Efficiency
These can pass the required discharge
with a very small working head (2.5cm)
PIPE OUTLET (CONT…)
Hydraulic characteristic

 Design formula
 Submerged pipe outlet
 q = c.d ×A ×√2g h(wk)
 Where
 h(wk) = difference in water surface levels in
the supply cannel and water course
 The value of c.d for ordinary cast iron pipe of
15 cm internal diameter has been
found to be nearly 0.00074.
 A simpler formula for this outlet is.
 q = c. d ×A ×√h (wk)
PIPE OUTLET (CONT…)
Hydraulic characteristic

Where, c. d = 0.028 and 0.033 respectively for long


(more than 600 cm ) and short (less than 600 cm )
pipes.
Free fall pipe outlet
q = c. d ×A×√H(cnt)
c. d = Coefficient of discharge = 0.0276
H (cnt) = head of upstream water surface over the
centre of the pipe.
 The discharge is sensibly correct so long as H (cnt)
is greater than 2D(p)(inside diameter of the pipe
and is approximately correct for H(cnt) = D(p) but
is approximately correct for H(cnt) = D(p) but is
appreciably different from that given by the
formula for H (cnt) less than D(p).
PIPE OUTLET (CONT…)
Hydraulic characteristic

 Adjustability
 While appreciable adjustment of the
design discharge would require
dismantling and reconstruction of the
structure or part of it, small changes in
discharge can be affected by lowering, or
raising the bed level at the pipe outlet,
and this would change the working head.
PIPE OUTLET (CONT…)
EXAMPLE

 Numerical example
Design an outlet for a discharge of 34 l/sec on
a distributing canal having a full supply depth
of 90 cm and with an available working head
of 6 cm.
 Solution
q = 34 l/sec
D = 90 cm
H(wk) = 6 cm
The available working head of 6 cm is low and
the outlet must be submerged.
q = c. d× A× √2g h(wk)
34 = 0.00074× [A(p) × √2g.6]
PIPE OUTLET (CONT…)
EXAMPLE

 A (p) = 34/(0.00074× √2g.6)


 A (p) = 423 Cm2
 And D(p)=23.3
 This may be rounded to the nearest
standard size of pipe available
Example
 If in example 1 the available working head
is75 cm , a wide choice would be possible
for the type of the outlet to use, if ,
however a pipe outlet is considered
desirable either from the point of view of
cost or if the outlet is required only
temporarily, it would be desirable to install
a free fall outlet so that it might work as a
semi-module. Assuming water level to be
200 m in the distributing canal, the water
level in the watercourse would be 200-
0.75 = 199.25m.
Example (Cont…)

 As a trial assume a pipe of 15 cm


diameter, then
 q = c.d × A ×√ H(cnt)
 By putting all values in the above
formula
 H(cnt) = 48.6 cm
 The centre of 15 cm pipe should be thus
at a level of 200 – 0.486
 = 199.515 m and the outlet would be
semi-modular.
Problems in Outlets of Punjab

 Discharge Measurement Problem.


 Theft Problem.
 Silting Problem.
 Proportional Distribution of water with
varying discharges.
All these problems are due to
improper designed which is the main
cause of problem.
Discharge measurement
problem
 There is a lot of difference between
authorized discharge and calibrated
discharge.
 Calibration of outlets (by Tin Flume) is a
good measure to check the accuracy of
outlets.
So, Defective outlets should be adjusted as
per their designed parameters.
Some of possibilities for
discharge measurement

Figure NO. 4.2


Some of the Possibilities for Volumetric Discharge
Measurement
Tin Flume for discharge
measurement

Figure No. 4.1 Tin Flume


Calibration of Outlet at 4-R
Hakara Canal (Haroonabad)
WC TYPE B Y Hu Q.th Q.ac Comm. c.d
59100/R PIPE 0.565 1.04 2.84 1.73 0.94
59130 A.O.S.M 0.3 1.368 2.06 5.4 3.46 0.64
60490 A.O.S.M 0.3 0.58 1.87 1.91 1.59 0.83
62500 PIPE Closed
63910 A.O.S.M 0.32 0.66 2.24 2.52 1.89 0.75
63910 OF 0.28 Closed
62080 A.O.S.M 0.32 0.50 2.54 2.08 1.71 0.82

65080 A.O.S.M 0.32 0.51 2.54 2.08 1.65 0.79


66050 OF 0.25 2.43 3.8 2.2 0.57
67500 PIPE 0.47 Closed
69100 PIPE 0.661 Closed
69490 PIPE 0.23 1.27 0.118 0.144 1.22
70640 OF 0.24 2.17 3.185 1.8 0.56
71100 PIPE Closed
71270 A.O.S.M 0.250 0.568 2.57 1.818 1.6 0.88
71735 A.O.S.M 0.457 0.310 2.13 1.09 1.09 1.00
71750 A.O.S.M 0.45 0.37 1.74 1.764 1.8 1.02
73600 PIPE Closed
73600 PIPE Closed
75366 A.O.S.M 0.32 1.132 2.44 4.561 1.87 0.41
78400 A.O.S.M 0.26 1.24 2.72 4.27 2.22 0.52
79224 A.O.S.M 0.3 0.99 2.4 3.64 2.33 0.64
79230 A.O.S.M Closed
81350 A.O.S.M 0.24 1.25 2.43 3.74 1.72 0.46
86376 A.O.S.M 0.31 1.365 2.39 5.26 3.05 0.58
87640 A.O.S.M 0.24 1.265 1.64 3.1 1.52 0.49
88920 A.O.S.M 0.25 0.61 3.025 2.14 1.71 0.8

89179 A.O.S.M 0.38 0.55 3.2 2.98 2.6 0.8


91706 PIPE 0.250 2.13 0.468 0.75 1.6
92631 A.O.S.M 0.260 1.222 2.66 3.85 2.86 0.69
93870 A.O.S.M 0.27 1.14 1.19 3.5 1.02 0.55
94300 A.O.S.M 0.31 1.250 2.33 2.7 2.33 0.86
91102 OF 0.22 1.77 2.36 1.4 0.59
95920 PIPE 0.765 2.2 2.75 2.62 0.95
96362 A.O.S.M 0.42 1.23 2.691 6.75 4.051 0.6
98729 A.O.S.M 0.32 1.23 2.2 4.68 2.81 0.6
101069 A.O.S.M 0.38 1.05 1.79 4.3 2.31 0.54
102214 OF 0.45 2.25 2.31 1.4 0.6
102234 A.O.S.M 0.49 0.82 1.526 3.98 2.15 0.54
104520 A.O.S.M 0.44 0.97 2.244 5.09 3.156 0.82
105634 OF 0.3 1.89 2.59 1.5 0.57
107020 A.O.S.M 0.46 0.72 1.737 3.52 2.15 0.61
107022 A.O.S.M 0.55 0.7 1.23 3.41 2.32 0.68
107055 A.O.S.M 0.488 0.675 1.135 2.81 1.25 0.48
109980 A.O.S.M 0.46 0.69 1.25 2.85 1.88 0.66
112000 OF 0.43 1.21 1.33 0.7 0.52
112050 OF 0.76 1.21 2.3 1.3 0.56
Analysis of data

 Total number of outlets calibrated = 47


 No. of A.O.S.M calibrated = 29
c.d of maximum ranges (0.41- 0.86)
which is less than 0.9
 No. of Open Flume calibrated =6
All has less c.d less than 0.62
 No. of Pipe Outlets calibrated = 4
Which has c.d approximately 0.9
Conclusion

 Many A.O.S.M & Open Flume Outlet has less


c.d because of the following reasons
a-Radius of upstream transition is not proper
b-Upstream face walls are not smooth.
c-Roof's block lower edge is not proper.
d-Turbulance is found out in control section.
e-Setting back is not proper
Setting Back is not proper
Face Walls are rough
Distorted Out d/s of Outlet
Discussion on discharge
formula for A.O.S.M
 Formula used is small orifice formula
Q=c.d×A×√2gHs
But, when Hs < 2Y
It is in valid
 Large orifice formula is

Ql =2/3 √2g (H23/2 – Hs3/2) b


Example

 Let we observe the


effect of both
formulas on an
outlet working
under varying head
of water, over the
orifice.
B = 0.22 ft, y = 0.37 ft, A = 0.22 x 0.37 = 0.0814 ft2
Graph between Hs @ % Error
2
35 E = 0.1176Hs - 1.6109Hs + 6.178
30 R2 = 0.8012
25
20
E

15
10
5
0
5

5
4.

3.

2.

1.

0.
Hs
Conclusion

 As we can see that by decreasing the


Hs, % error goes on increase. So, Hs
should be at least 3 times of orifice
opening in order to keep the error in
permissible limit.
Theft of canal Water

 It is noticed that average 20% of canal


water in Rabi season and 40% in
Kharif season is snatched.
Means of theft water

 By siphon pipes.
 Fixing pipes in the bank.
 Tampering of outlets
 Cutting canal banks.
 Putting hurdles down stream outlets.
 Installing wrong types of outlets
 Legalized Tampering
Remedial Measures

 Outlets should be tamper-proof and


any tampering should be easily
detectable
 Preparation and processing of Tawan
cases should be according to revenue
manual of Irrigation and Power
Department.
Silting problem in canals

The silting in the parent channel is due


to:
 Faulty design of parent channel.
 Defective head regulator.
 Defective outlets
Control of silt through outlet

 Setting of outlet
 Bend outlet
 Pipe Semi-Module
Pipe Semi-Module
Control of silt in Punjab canals

 Pipe Semi-Module offers a complete


control over the silt induction by the
outlet.
 But, some points should be kept in
mind.
Setting of outlet for proportion
al distribution of water.
 For normal irrigation system a higher setting
is more desirable than proportional setting.
 For non- perennial system, it is essential to
have proportional setting so that an equal
amount of water is distributed at all times.
Suitability of adaptability of
World types in Pakistan

Two types can be successfully used in


Pakistan
 Plastic Siphon outlet (Turkey)

 P.V.C Pipe Turn out (Korea)


Plastic Syphon Outlet
P.V.C Pipe Turn Out

Figure No. 3.12 PVC Pipe Turnout


Conclusions and
Recommendations
 Pipe Type Outlet of Pakistan can be
successfully replaced by P.V.C. Pipe Turnout
(Korea).
 Plastic Siphon Outlet can be successfully
used in Potohar region of Pakistan where
slopes are so steep that dynamic velocity
head can be successfully utilized for lift
irrigation.
 Irrigation efficiency of the Outlets can be
increased by proper designing of outlets.
 In order to keep percentage error
within a permissible limit as in case of
A.O.S.M it is advantageous to use the
water depth on the top edge of the
orifice more than three times the depth
of orifice.
 The tail reaches of the canals should
closely monitored by the Irrigation
Department as these are indicators of
theft in the canal system.
 Pipe Semi Module is the best choice if
we can not kept a lower setting of the
outlet for proper silt control.
 Higher setting of outlets should be
preferred in perennial canals while
proportional setting should be
preferred in non perennial canals.
Thanks

You might also like