Professional Documents
Culture Documents
Control Charts For Attributes: P-Chart
Control Charts For Attributes: P-Chart
for Attributes
p-chart: A chart used for controlling
the proportion of defective services or
products generated by the process.
p = p(1 p)/n
Where
n = sample size
p = central line on the chart, which can be either the historical
average population proportion defective or a target value.
Control limits are: UCLp = p+zp and LCLp = pzp
Is the booking process out of statistical control? Use three-sigma control limits.
Hometown Bank
Using a p-Chart to monitor a process
n = 2500 Sample Wrong Proportion
147 Number Account # Defective
p= = 0.0049
12(2500) 1 15 0.006
2 12 0.0048
p = p(1 p)/n 3 19 0.0076
4 2 0.0008
p = 0.0049(1 0.0049)/2500 5 19 0.0076
6 4 0.0016
7 24 0.0096
p = 0.0014
8 7 0.0028
UCLp = 0.0049 + 3(0.0014) 9 10 0.004
10 17 0.0068
= 0.0091 11 15 0.006
LCLp = 0.0049 3(0.0014)
12 3 0.0012
= 0.0007
Total 147
Hometown Bank
Using a p-Chart to monitor a process
Example
In class Problem
Control Charts
Two types of error are possible with
control charts
A type I error occurs when a process
is thought to be out of control when
in fact it is not
A type II error occurs when a process
is thought to be in control when it is
actually out of statistical control
These errors can be controlled by the
choice of control limits
Process Capability
Nominal
value
Process distribution
Lower Upper
specification specification
20 25 30
Process is capable
Process Capability
Nominal
value
Process distribution
Lower Upper
specification specification
20 25 30
Process
Cpk = Minimum of 1.53, 0.94 = 0.94 Capabilit
y Index
Intensive Care Lab
Assessing Process Capability
Example
Upper specification - Lower specification
Cp =
6
30 - 20
Cp = = 1.23 Process Capability Ratio
6(1.35)
Four sigma
Two sigma
Lower Upper
specification specification
Mean
What it means to operate at 6-
sigma
Expected frequency Approx. frequency for
Range Population in range
outside range daily event
ISO
A set of standards governing
documentation of a quality program.
9000
Documentation standards that require
14000
hazardous wastes.
Malcolm Baldrige National
Quality Award
Named after the late secretary of commerce, a strong
proponent of enhancing quality as a means of
reducing the trade deficit. The award promotes,
recognizes, and publicizes quality strategies and
achievements.
1. Category 1 Leadership 120 points
2. Category 2 Strategic Planning 85 points
3. Category 3 Customer and Market Focus 85 points
4. Category 4 Measurement, Analysis, and