Water Chemistry Aspects For Supercritical Unit: V Chandrasekharan Sr. Manager NTPC Sipat
Water Chemistry Aspects For Supercritical Unit: V Chandrasekharan Sr. Manager NTPC Sipat
ASPECTS FOR
SUPERCRITICAL UNIT
V Chandrasekharan
Sr. Manager
NTPC SIPAT
DETAILS
WATER TREATMENT
OT INTRODUCTION
BOILER ACID CLEANING
BOILER WATER PARAMETERS
LP & OXYGEN DOSING SYSTEM
ON LINE MONITORING
CHANGE OVER FROM ALKALINE
TREATMENT TO OT
WATER TREATMENT -
EXTERNAL
Depending on the source of water
1. Clarification
2. Filtration
3. Demineralization
4. DM With RO
Make up water quality at DM Outlet
Conductivity of > 0. 1 ms/cm
Silica - <10 ppb
FEED WATER TREATMENT
Acceptable limits
corrosion rate should be less than 0.1 Mg/cm2/hr
Citric Acid: which dissolves the rust. The pH is raised to an alkaline value
using ammonia, and the sequestered iron remains in solution
Function of Chemicals
Inhibitor: Makes a passivation layer to save
the parent metal
Detergent: Removes oil & grease
QUALITY OF
MAGNETITE LAYER
FORMATION AFTER
PASSIVATION AS
VISUAL INSPECTION.
FEED WATER SPECIFICATION
S.NO Parameter Units Normal Operation During
Start up
4 DEAERATOR OUTLET DO