MAXIMUM POWER POINT TRACKED PV SYSTEM

WITH SMES BASED POWER STABILIZATION FOR


ISOLATED POWER SYSTEM

GUIDED BY, PRESENTED BY,


PROF. ASEEM K SHANIBA TP
ASSISTANT PROFESSOR S2 M-TECH
1
EEE DEPARTMENT
LBSCEK
CONTENTS
2

1. INTRODUCTION
2. GENERAL V-I AND P-V CHARACTERISTICS OF SOLAR CELL
3. PV ARRAY BLOCK
4. VARIATION IN SUN IRRADIANCE AND TEMERATURE
5. MAXIMUM POWER POINT TRACKING
6. INCREMENTAL CONDUCTANCE(IC)
7. FLOWCHART OF IC ALGORITHM
8. MATLAB BASED MPPT MODEL
9. SIMULATION MODEL & OUTPUT OF PV WITH FAULT
10. SIMULATION MODEL & OUTPUT OF PV WITHOUT FAULT
11. SMES AND CONTROL BLOCK DIAGRAM
12. CONCLUSIONS
13. REFERENCES
INTRODUCTION
3

MATHEMATICAL MODEL OF SOLAR CELL


GENERAL V-I AND P-V
4
CHARACTERISTICS OF SOLAR CELL
PV ARRAY BLOCK
5

PARAMETERS VALUES
PARALLEL 66
STRINGS
SERIES 5
CONNECTED
MODULE PER
STRINGS
VOC 64.2
Isc 5.96
Vmp 54.7
IMP 5.58
VARIATION IN SUN IRRADIANCE AND
6
TEMERATURE
7
8 MAXIMUM POWER POINT
TRACKING

 MPPT is an algorithm that included in charge controllers used for


extracting maximum available power from PV module under certain
conditions.

 The voltage at which PV module can produce maximum power is


called maximum power point voltage.

 MPPT TECHNIQUES:-

• PERTURB AND OBSERVE


• INCREMENTAL CONDUCTANCE
• BETA METHOD
INCREMENTAL CONDUCTANCE(IC)
9

 Incremental conductance considers the fact that the slope of the power-
voltage is zero at maximum power point(MPP), positive at the left of MPP
and negative at the right of MPP.
10
FLOWCHART OF IC ALGORITHM
11
MATLAB BASED MPPT MODEL
12 SOLAR BASED POWER SYSTEM WITH SMES
13 SIMULATION MODEL OF PV WITH MPPT
PV OUTPUT WITHOUT FAULT
14
SIMULATION MODEL OF PV WITH FAULT
15
16
PV OUTPUT WITH FAULT
SMES AND CONTROL BLOCK DIAGRAM
17
SIMULINK MODEL OF SMES WITH CONTROL
18
CONTROL BLOCK OF SMES INVERTER
19
20
CONCLUSIONS

 Simulation model of PV system without SMES is done.

 Theoretical analysis and simulation verification is done on the


transient performance of photovoltaic based microgrid without
SMES.

 When the SMES is not applied, The power transmitted to the load
reduces greatly during the fault.
REFERENCES
21
• lei chen , member, ieee, hongkun chen, yanhong li, guocheng li“Smes-battery
energy storage system for the stabilization of a photovoltaic-based microgrid”, IEEE
Transactions On Applied Superconductivity, Vol. 28, No. 4, June 2018.

• M. Farhadi and o. Mohammed“energy storage technologies for high-power


applications,”IEEE Trans. Ind. Appl., Vol. 52, No. 3, Pp. 1953–1961, May 2016

• Y. Kim, V. Raghunathan, and A. Raghunathan, “Design and management


• of battery-supercapacitor hybrid electrical energy storage systems for regulation
services,”IEEE Trans. Multi-Scale Comput. Syst., vol. 3, no. 1,
• pp. 12–24, Jan.–Mar. 2017

• L. Chenet al., “Conceptual design and evaluation of an HTS magnet for


• an SMES used in improving transient performance of a grid-connected
• PV system,”IEEE Trans. Appl. Supercond., vol. 28, no. 3, Apr. 2018, Art.
• no. 4600708.
22