0 50 150 250 350 450 550 650 1916

SKEW 90

A B
C

WELD
WELD

D G
E
F

SKEW 270 QUALIFICATION BLOCK ATI-VAL-24"-THK 32mm - 38.89mm

FLAW DETAILS
DEFECT LENGTH mm HEIGHT mm LOCATION FROM DEPTH mm TYPE OF FLAW
“0” mm A STAR TESTING & INSPECTION (M) SDN. BHD.

A 7.5 2.5 50 0 TOE NOTCH No121, Jalan Kempas 1, Taman Desaru Utama,
81930 Bandar Penawar, Johor
B 10 3 150 16 SWLOF
THIS DOCUMENT AND INFORMATION HEREIN IS THE
C 10 3 250 16 SWLOF PROPERTY OF A-STAR TESTING & INSPECTION AND
MUST NOT BE USED OR REPRODUCED WITHOUT
D 10 3 350 20 SLAG PRIOR WRITTEN PERMISSION
E 10 3 450 16 SWLOF
F 10 3 550 16 SWLOF
G 7.5 2.5 650 32 ROOT NOTCH NOTE: ALL DIMENSIONS ARE IN "mm"
WPS - PROFILE

37.5® 37.5®

SKEW 90 SKEW 270

32
20
38.89
1.5

QUALIFICATION BLOCK ATI-VAL-24"-THK 32mm - 38.89mm


A-TOE- NOTCH

HEIGHT
SKEW 90 SKEW 270
THICKNESS

THICHNESS
QUALIFICATION BLOCK ATI-VAL-24"-THK 32mm - 38.89mm
B-SWLOF

SKEW 90 SKEW 270

DEPTH
THICKNESS

THICHNESS
HEIGHT

QUALIFICATION BLOCK ATI-VAL-24"-THK 32mm - 38.89mm


C-SWLOF

SKEW 90 SKEW 270

DEPTH
THICKNESS

THICHNESS
HEIGHT

QUALIFICATION BLOCK ATI-VAL-24"-THK 32mm - 38.89mm


D-SLAG

SKEW 90 SKEW 270

DEPTH
THICKNESS

HEIGHT

THICHNESS
QUALIFICATION BLOCK ATI-VAL-24"-THK 32mm - 38.89mm
E-SWLOF

SKEW 90 SKEW 270

DEPTH
THICKNESS

THICHNESS
HEIGHT

QUALIFICATION BLOCK ATI-VAL-24"-THK 32mm - 38.89mm


F-SWLOF

SKEW 90 SKEW 270


DEPTH
THICKNESS

HEIGHT

THICHNESS
QUALIFICATION BLOCK ATI-VAL-24"-THK 32mm - 38.89mm
G-ROOT NOTCH

SKEW 90 SKEW 270


DEPTH
THICKNESS

THICHNESS
HEIGHT

QUALIFICATION BLOCK ATI-VAL-24"-THK 32mm - 38.89mm

You might also like