Basic SCBA

Self-Contained Breathing
Apparatus

Alabama Fire College


Introduction
• Failure to use the SCBA properly can
result in injury or death
• Respiratory system extremely
vulnerable
• Fire departments must have a mask
rule
• Wear and use SCBA in IDLH
atmosphere
• SCBA necessary even during exterior
defensive operations
7.2
Alabama Fire College
Introduction (cont’d.)
• Any inhaled toxic gas can directly
cause disease of the lung tissue
• One in 12 firefighters is injured in
the line of duty each year
• Smoke inhalation accounts for 18
percent of fatalities
– 21 percent of fireground injuries

7.3
Alabama Fire College
Conditions Requiring
Respiratory Protection
• Oxygen deficiency
• High temperatures
• Smoke or by-products of
combustion
• Toxic environments

7.4
Alabama Fire College
Oxygen-Deficient
Environments
• Fire consumes oxygen
– Produces toxic gases
– Displace or dilute oxygen
• Oxygen concentrations below 19.5
percent are oxygen-deficient
atmospheres
• Affects on the human body:
– Muscular impairment
– Mental confusion
– Death 7.5
Alabama Fire College
Table 7-1 Effects of Hypoxia (Reduced Oxygen)

7.6
Alabama Fire College
Elevated Temperatures
• Respiratory system sensitive to
temperature
• Air temperatures as low as 165°F can
cause death within 1 minute
• Inhaling gases causes:
– Pulmonary edema
– Asphyxiation
– Long-term damage
• Temperatures in structure fire reach
1000°F
– One unprotected breath will cause death or
severe damage to respiratory system
7.7
Alabama Fire College
Smoke
• Unburned products of combustion,
particles of carbon, tar, associated gases
• Large amounts of gases due to use of
plastics
• Inhalation of small amounts may be fatal
• Four causes of damage by smoke:
– Asphyxiation
– Chemical irritation
– Chemical asphyxiation
– Any combination of these

7.8
Alabama Fire College
Effects of Toxic Gases
and Toxic Environments
• Combustion produces toxic gases and
irritants
– Affect short- and long-term health
• When combustion products combine may
form lethal toxins
• Some common gases affect circulatory
system
• Commercial occupancies may produce
additional toxins
– Requires higher level of protection
7.9
Alabama Fire College
Table 7-2 Toxic Gases Formed as Products of Combustion

7.10
Alabama Fire College
Legal Requirements for
Self-Contained Breathing
Apparatus Use
• Common sense: Use SCBA on every
fire scene
– Start to finish
• Regulations developed for SCBA use
• Organizations established regulations
and standards

7.11
Alabama Fire College
Title 29 Code of Federal
Regulations, Section 1910.134
• Establishes standards for all entries into
IDLH atmospheres
• April 1998 revision contains requirements
related to interior structural firefighting
– Defines interior structural firefighting as IDLH
• Requires the use of SCBA
• Requirements for complete respiratory
protection program
– Regular medical evaluation

7.12
Alabama Fire College
NFPA 1500: Standard on Fire
Department Occupational Safety
and Health Program
• Authority having jurisdiction (AHJ) must
adopt the standard for the fire department
• Three additional standards:
– NFPA 1404: minimum requirements for
protection programs
– NFPA 1981: design and performance criteria
– NFPA 1982: standards on PASS

7.13
Alabama Fire College
Limitations of Self-Contained
Breathing Apparatus
• Understand limitations to use unit
effectively and safely
• Limitations of the SCBA unit itself
– Size, weight, air supply
• Physiological limitations of the user

7.14
Alabama Fire College
Figure 7-7 Continuous training with SCBA is one of
the keys to effective firefighting operations.

7.15
Alabama Fire College
SCBA Design and Size
• SCBA units add weight and bulk to PPE
• SCBA cylinder consumed more quickly
than length of time rated for:
– Limits advance into building
– More frequent crew rotations
• Other concerns:
– Restricted visibility
– Added weight and bulk
– Firefighter’s voice muffled
– Limited air quantity

7.16
Alabama Fire College
Limitations of the SCBA User
• Physical, mental, emotional state
cause usage problems
– Physical limitations: added weight and
bulk
– Physiological limitations
• Lack of confidence in SCBA unit
• Physical stress and anxiety
• Emotional conditions

7.17
Alabama Fire College
Air Supply Management
• Air supply management
– Must understand air consumption rates
– Individual point of no return
– Heads up display
• Various methods of breathing take
experimentation on the part of the firefighter
– Use normal breaths and exhale slowly
– Never hold breath
– Controlled breathing is most efficient use of air

7.18
Alabama Fire College
Figure 7-11 An example of an air consumption test.

7.19
Alabama Fire College
Types of Self-Contained
Breathing Apparatus
• Two types of SCBA:
– Open-circuit SCBA
• Exhaled air is vented to outside
atmosphere
• Most common
– Closed-circuit SCBA
• Exhaled air stays in the system for
filtering, cleaning, circulation
• Sometimes used for specialized rescue
incidents

7.20
Alabama Fire College
Open-Circuit Self-Contained
Breathing Apparatus
• Designed and built in accordance
with NIOSH and NFPA standards
• Four basic assembly components:
– Backpack and harness
– Cylinder
– Regulator
– Face piece assembly

7.21
Alabama Fire College
Figure 7-13 The four components of the open-circuit SCBA
are the backpack/harness, cylinder, regulator, and face piece
assemblies.

7.22
Alabama Fire College
Head Harness

Head Straps
Nose Cone

Voice Emitter Head Straps

Regulator Adapter Port

7.23
Alabama Fire College
Heads Up
Purge Valve Display
(Emergency (HUD)
Bypass)
Face Piece Lock Tab
Mechanism

Regulator Quick
Air Saver Switch or
Disconnect with HUD
Connector the
Don/Doff Switch

7.24
Alabama Fire College
Closed-Circuit Self-Contained
Breathing Apparatus
• Not used for firefighting operations
• Most common use: hazardous materials
incidents
• Air supplies range from 30 minutes to four hours
• Contain cylinder, filter system, regulator, and
valves
• Clean and filter exhaled breath and add oxygen
– Air supply duration based on filtering/cleaning and
oxygen capacity of unit

7.25
Alabama Fire College
Open-Circuit Supplied
Air Respirators
• Open-circuit supplied air respirators
(SARs)
– Also called airline respirators
– Remote air supply
• Commonly used for hazardous materials
incidents
– Confined space rescues
• Long-duration of air supply, mobility, agility
• SCBA escape unit with 510 minutes

7.26
Alabama Fire College
Inspection and Maintenance of
Self-Contained Breathing
Apparatus
• Inspection on daily or regular basis
• Always follow manufacturer’s
instructions
• Procedures in this chapter may differ
from the recommendation

7.27
Alabama Fire College
Daily Maintenance
• SCBA units should be checked
daily
• If used during emergency scene or
training exercise should be
serviced in same manner
• Follow 10-step inspection
procedure

7.28
Alabama Fire College
Monthly Maintenance
• Monthly SCBA check contains all
elements of the daily check
– Adds several checks of mechanics of
system
• Irregularities noted and repaired or
pull SCBA from service

7.29
Alabama Fire College
Annual and Biannual
Maintenance
• NIOSH and SCBA manufacturers
require different functional tests of
SCBA units
• Only manufacturer’s authorized or
trained service personnel shall
conduct these tests
• Firefighters should refer to the
instructions for the SCBA units used
7.30
Alabama Fire College
General Considerations
• Operational safety checks must be
performed
• Conducted on a daily or regular
basis
– Immediately prior to using the SCBA
unit
• If any component does not operate
properly or is damaged, unit taken
out of service immediately
7.31
Alabama Fire College
Figure 7-23 Firefighters must perform regular checks
of SCBA to ensure the unit’s ability to operate.

7.32
Alabama Fire College
Donning and Doffing Self-
Contained Breathing Apparatus
• Most common donning procedures:
– Seat-mounted position in the apparatus
– Side compartment on the apparatus
– Storage case
• Refer to manufacturer’s instructions

7.33
Alabama Fire College
Storage Case
• Two methods to don unit:
– “Over the head”
– “Coat”
– Choice is a matter of personal
preference and training
• Refer to donning instructions for the
particular SCBA unit

7.34
Alabama Fire College
Seat-Mounted Apparatus
• Allows for quick donning
• Unit readily available for regular
inspection
• Three important safety requirements:
– Storing of the face piece
– Donning the unit while vehicle is moving
– Checking the cylinder gauge
• Never don while vehicle is in motion
• Check gauge before response or use the
buddy system

7.35
Alabama Fire College
Compartment or Side-Mounted
Apparatus
• Similar to seat-mounted position
except firefighter is standing
• If mount bracket wrong height, use
“coat” method
• Follow donning methods for particular
mounting style

7.36
Alabama Fire College
Donning the SCBA Face Piece
• Most SCBA face pieces donned in a similar
manner
– Difference in style of head straps, regulator
location
• Essential to protect firefighter from toxic
gases
• Firefighter must be fitted for the face piece
to be used with a particular manufacturer’s
SCBA
• Prohibit anything that may interfere with
proper fit and seal of face piece
– Examples: eye glasses, beards, sideburns

7.37
Alabama Fire College
Removing/Doffing the
SCBA Unit
• Generally to remove SCBA donning procedure
is reversed
• If awaiting another assignment, remove face
piece
– Allow normal breathing, conserve air
• Do not wear the mask without air flowing into it
• Regulator or face piece must not be
contaminated
• After assignment complete, report to
rehabilitation
7.38
Alabama Fire College
Self-Contained Breathing
Apparatus Operation and
Emergency Procedures
• Fire departments must establish
respiratory protection programs
• Firefighters must be proficient in the
safe use of SCBA
– Donning and doffing procedures
– Individual limitations
– Limitations of SCBA unit
7.39
Alabama Fire College
Safe Use of SCBA
• Essential to firefighter survival
• SCBA unit and protective
equipment add weight and bulk
– Increased exertion and loss of body
fluids
• Firefighters must be aware of
symptoms of heat stress
– Be aware of own limitations and
abilities

7.40
Alabama Fire College
Operating in a Hostile
Environment
• General rules:
– Check in with accountability officer when entering
or exiting
– Remain low, check the environment and
conditions
– Never remove the face piece, maintain an
awareness of location
– Ventilate as you advance if it does not spread fire
– Check for outside openings
– Maintain direct contact with other team members
– Never enter a hostile environment alone
7.41
Alabama Fire College
Restricted Openings
• Probe tight spot with a tool
• Be sure conditions on other side of
obstacle are safe
• Shift pack to left side
• “Swim” through obstacle backwards
• “Forward dive” technique
• Do not remove SCBA unless
absolutely necessary

7.42
Alabama Fire College
Figure 7-31 Firefighters may have to get beneath an
obstacle to facilitate their escape, which may also
require them to lower their profile.

7.43
Alabama Fire College
Emergency Procedures
• Emergency procedures exist to assist a
firefighter in safe escape from hazard
• Remain calm, rely on training and
knowledge
• Never remove the face piece of the SCBA
• Standard emergency check procedure
stressed
• If entangled, do not pull forward
– Use wire cutters to cut one wire at a time
– “Swim” method

7.44
Alabama Fire College
Figure 7-32 Emergency procedures check.

7.45
Alabama Fire College
Changing SCBA Cylinders
• Cylinders changed after use, following
local SOPs
• Cylinder 90 percent full could mean loss
of 25 minutes of air supply
– Could make the difference in successful exit
• Follow 12-step replacement procedure
• Additional steps for two-person SCBA
cylinder replacement

7.46
Alabama Fire College
Servicing SCBA Cylinders
• Cylinder serviced when below full
– Air source must be tested and certified
– All cylinders must have a current
hydrostatic test date
– All fill stations must have fragmentation
containment devices
– All manufacturer’s recommendations
should be followed
– Fill rate may vary
• Cascade system
• Compressor/purifier system
7.47
Alabama Fire College
(A) (B)

Figure 7-36 (A) A cascade system is one of the systems available


to service SCBA cylinders. These may be fixed or mobile units. (B)

7.48
Alabama Fire College
Lessons Learned
• SCBA unit is to a firefighter as a weapon is
to a soldier
• No substitute for proper SCBA training
– Continued practice and advanced training
necessary
• Prevent failures: thoroughly inspect and
test SCBA function as often as possible
• Firefighters must be prepared to go in
harm’s way
– Be knowledgeable and proficient in use of SCBA

7.49
Alabama Fire College
Summary
• SCBA is one of the most important items of PPE
that firefighters have available to them.
• An increase in safety regulations and
improvements in design and construction of
SCBA have greatly increased their safety and
reliability.
• An SCBA has limitations and also increases the
limitations and demands on the firefighter’s
physical conditioning.

7.50
Alabama Fire College
Summary
• The firefighter must be familiar and
comfortable with the use, emergency
procedures, inspection, and maintenance
of an SCBA.
• The firefighter must be proficient in the
proper and rapid procedures for donning
and doffing SCBA.

7.51
Alabama Fire College