Professional Documents
Culture Documents
INSTITUTE OF TECHNOLOGY
SCHOOL OF CIVIL AND HYDRAULIC
ENGINEERING
1
SECONDARY/BIOLOGICAL WASTEWATER TREATMENT
2
3
Most commonly used biological processes are:
Trickling Filters
The Activated Sludge Process
Aerated Lagoons/ Stabilization Ponds
Rotating Biological Contactors
The common methods of biological wastewater treatment are:
a)Aerobic processes such as
activated sludge process, - suspended growth type
Trickling filters, attached growth type
Rotating biological contactors, attached growth type
Oxidation ponds and lagoons, oxidation ditches, suspended growth
type
Constructed wetland
b) Anaerobic processes such as anaerobic digestion, and UASB
c) Anoxic processes such as denitrification.
4
5
6
SECONDARY/BIOLOGICAL WASTEWATER TREATMENT
Principles of Biological Wastewater Treatment
Role of MO’s in WWT:
MO’s are the primary agents of biological WWT processes.
(bacteria, fungi, protozoa, and crustaceans)
7
SECONDARY/BIOLOGICAL WASTEWATER TREATMENT
Process;
8
SECONDARY/BIOLOGICAL WASTEWATER TREATMENT
Many types of microorganisms can be found in the wastewater treatment
system. However, the types of organisms that will dominate will be the
ones that are best suited to the “environment” or conditions in the
system.
Wastewater treatment systems are designed to foster an “environment”
that suits a certain type of microorganism.
These microorganisms not only remove organic wastes from the water,
but they also “settle out” as solid material for easy removal.
It is required to maintain the right conditions in the treatment system for
the right type of microorganisms.
If the right conditions are not present, the wrong microorganisms will
dominate.
These “wrong” microorganisms not only interfere with the successful
removal of wastes from the water, but they themselves may be difficult to
remove from the system.
9
G E N E R A L C H A R AC T E R I ST I C S O F M O ’ S
Growth kinetics
Growth of a microbial population is defined as an increase in numbers or an
increase in microbial mass.
Growth rate is the increase in microbial cell numbers or mass per unit
time.
Microbial populations can grow as:
10
1. Batch Cultures
Batch culture is the most common laboratory growth method in which
bacterial growth is studied,
When a suitable medium is inoculated with cells, the growth of the microbial
population shows four distinct phases.
11
2. Continuous Culture of Microorganisms
the exponential growth phase over a long
period of time can be achieved by growing
continuously the cells in a completely mixed
reactor in which a constant volume is
maintained.
The most commonly used device is the
chemostat
is a bioreactor to which fresh medium is
continuously added, while culture liquid
containing left over nutrients, metabolic end
products and microorganisms is continuously
removed at the same rate to keep the culture
volume constant
12
Physical and Chemical Factors Affecting Microbial Growth
1. Substrate Concentration
2. Temperature
3. pH
4. Oxygen Level
13
Trickling filter
A trickling filter is a bed of solid media for bacteria to
attach on its surfaces
Also called a biological filter/bio-film process/ slim layer
or fixed film process
Attached Growth Processes
14
Trickling filter
15
Trickling Filter (TF)- side view
16
B i o l o g i c a l Wa ste wate r Tre at m e nt
18
Trickling Filters
The liquid then washes the slime off the packing, and a new slime layer
starts to grow. The phenomenon of losing the slime layer is called
sloughing
The percolating sewage is collected at the bottom of the tank through a
well designed under-drainage system.
The effluent must be taken to the secondary sedimentation tank for
settling out the solids generated as a result of WW treatment.
19
Design consideration
Influent wastewater characteristics
Degree of treatment anticipated (BOD & TSS
removal).
Temperature range of applied wastewater
Pretreatment processes
Type of filter media
Recirculation rate
Hydraulic and organic loadings applied to the filter
Under drainage and ventilation systems
20
Design consideration - Recirculation
Why is recirculation required?
maintain constant wetting rate
dilute toxic wastes
increase air flow
recirculation flow dilutes the strength of raw
wastewater & allows untreated wastewater to be passes
through the filter more than once.
A common range for recirculation ratio
0.5 - 3.0
21
Trickling Filters
Distribution system
Provides uniform hydraulic loading on the filter
surface
Rotational speed is usually 1 rev/10 min
Under drain system
Supports the media
Collects the effluent
Permits circulation of air through the bed
Made of vitrified clay (for stone media) or simple
metal gratings (for plastic media)
Configuration
Trickling filters can be employed as a single unit,
units in series, or units in parallel
22
Flow Diagram for Trickling Filters
Recirculation= A portion of the TF effluent recycled through the filter
Recirculation ratio (R) = returned flow (Qr)/ influent flow (Q)
Recycle
Final
clarifier
Final
Influent effluent
Primary Waste
clarifier sludge
Trickling
filter
23
Trickling Filters
24
Trickling Filters
Single stage
25
Trickling Filters
Two stage
26
Trickling Filters
Design of Trickling Filters
involves the design of :
the diameter of the circular filter tank and its depth
Filter media
the distributors and
under-drainage system
Efficiency
Filter size
the filter diameter and depth is designed for average value of sewage flow.
Is based upon the values of the filter-loadings adopted for the design.
This loading on a filter can be expressed in two ways:
The design of the filter size is based upon the values of the filter-loadings
adopted for the design.
1. Organic loading rate
2. Hydraulic loading rate
1. Organic (BOD) loading rate:
Is the mass application rate of organic matter per unit volume of reactor.
Expressed as kg of BOD/m3/d
Typically, 0.320 - 0.640 kg/m3/d for single-stage filters
Typically, 0.640 -0.960 kg/m3/d for two-stage filters
27
Trickling Filters
2. Hydraulic loading rate:
Flow per unit area (m3 wastewater/m2 filter*d)
the rate of total influent flow is applied to the surface of
the filter media
Total influent flow = the raw WW + re circulated flow
Typically, 9.4 m3/m2/d
Maximum, 28 m3/m2/d
Knowing the area and volume, depth & diameter can be easily
determined
The depth of the rock packing ranges from 0.9 to 2.5 m (rock fill)
Moreover, since the rotary distributors are available indigenously only
up to 60m in length, it is desirable to keep the diameter of the filter
tank up to a maximum of 60m.
If the required filter diameter is more than 60m, then it is better to
use more units of lesser diameter. 28
Trickling Filters
Filtering medias (stone used)
consists of coarser materials like cubically broken stones, plastic packing,
slag …
should not be easily affected by acidic WW, and should be sufficiently
hard.
Its resistance to freezing and thawing is another important property,
A material with a specific surface area between
45 and 60 m2/m3 for rocks and
90 and 150 m2/m3 for plastic packing is normally used
Generally may range b/n 25-75mm
The filtering material may be placed in layers; with coarsest stone used
near the bottom, and. finer material towards the top.
should be washed before it is placed in position to free from dust
29
Trickling Filters
Sewage distributors over filters: are two types
- Rotary distributor:
The rotary distributor consists of a hollow vertical central column
carrying two or more radial pipes or arms, each of which contains a
number of nozzles or orifices for discharging the waste water onto the
filter media.
All of these nozzles point in the same direction at right angles to the
arms.
The force of the water causes the spray heads to rotate above the media,
acting like a sprinkler and evenly distributing waste water across the media.
(can also be driven by electric motor)
The rotary reaction is furnished by a head of 45 to 60cm.
- Spray nozzles:
• Stationary /Fixed/ Individual Spray Heads work best
for smaller areas
30
Trickling Filters
Under drains
Vitrified clay blocks are generally used as under-drains.
Ensures satisfactory drainage ……. Manning formula
The blocks are laid directly on the filter floor, which is sloped toward the
collection channel at 1 to 5% gradient.
The effluent channels are sized to produce a minimum velocity of 0.9
m/s
also ensure satisfactory ventilation and aeration of the filter bed
→ To allow air circulation, the under-drainage system should be
designed to flow half full
31
Trickling Filters
Efficiency:
32
Trickling Filters
33
Trickling Filters
34
Trickling Filters
35
Trickling Filters
36
Common Operational Problems
1. Fly nuisance
The filter fly which develops in the filter particles, may
prove to be nuisance, as the same may be carried away
into the habitation.
2. Odour nuisance
Odors, generally, do not prevail in trickling filters using
rotary distributors; but however, when fixed nozzles are
used, H2S and other odorous gases are frequently released
from the sprays into the atmosphere.
3. Ponding trouble
Sometimes, the voids in the filter media get clogged due
to heavy growth of fungi and algae. This may result in
ponding of the sewage over the filter bed.
37
Example-1
38
Example-2
A municipal wastewater having a BOD of 200mg/L is to
be treated by a two-stage trickling filter. The desired
effluent quality is 25 mg/L of BOD. If both of the filter
depths are to be 1.83 m and the recirculation ratio is 2:1,
find the required filter diameters.
Assume the following design assumptions:
Influent flow = 7570 m3/d
Recirculation ratio = 2
Depth of media = 1.83 m
Water temperature = 20oC
BOD removal in primary sedimentation = 35%
E = E = 0.65
1 2
39
Example -3
Influent BOD =200mg/L, influent flow = 1.8 ML/d,
diameter of the filter is 16 m & the depth of the filter is
2m. Calculate the organic loading rate.
Example 4
Influent flow = 8.5ML/d, the recirculation ratio is 2:1.
Diameter of the filter is 16 m & the depth of the filter is
2m. Calculate the hydraulic loading rate.
40