• Classroom Training
• DigiTest EDGE Hardware Overview
• Telaccord1000 Access Hardware Overview
• Overview of Installation of DigiTest EDGE and
Telaccord1000
• Lab Training
• Hands-On Installation Training
TAP1
LoopCare
DSL Services TAP2 TAP3 TAP4
DSLAM
POTS/DSL Services
ATM Core
Other Test Access
DSLAM/ngDLC
POTS Services
ngDLC
POTS/DSL Services
Optical
DSLAM Transport
Test Access Splitter
PSTN Core
HARDWARE OVERVIEW
• DigiTest EDGE:
• Compact, low-cost test solution for CO, Colo, and RT sites.
• Supports a wide variety of telecom services
• POTS, xDSL
• Mechanical
• 2RU
• NEBS Level 3, CE Certified
• Northbound communications
• Analog Dial-up
• Serial
• Ethernet
• DSL (ATU-R) Optional
• Test Access / Control
• Four 2-wire Metallic Test TAPs
• Also configurable as Two 4-wire Metallic Test TAPs
• Four serial ports / Integrated Terminal Server
• Control downstream serial devices
PROPRIETARY • TOLLGRADE AND AUTHORIZED CLIENTS ONLY
This document contains proprietary information that shall be distributed or
routed only within Tollgrade Communications, Inc. and its authorized
clients, except with written permission of Tollgrade.
DigiTest EDGE Feature Summary
• NB Metallic Testing:
• Voltage, Resistance, Capacitance, Load Coil Detect/Count, C-Message Noise, NB Tone,
Longitudinal Balance……
• DSL Testing:
• TDR – Bridged Tap Identification/Location
• Wideband Noise (E/F/G Filters)
• Send/Receive WB Tone
• ADSL and/or G.shdsl Service Assurance – DSL, ATM, IP, HTTP verification (DSL
Client/Server Emulation)
CHASSIS
Control Module
SLQ
Broadband Services
Option Fan & Filter
Status
LEDs
Front View
Rear View
Power Input
CONTROL MODULE
• Control Module
• Provides all communications and management of the DigiTest EDGE system
• Installs in the top horizontal slot of the EDGE chassis
• Hosts external connections for communications and testing
• Ethernet, Analog Modem, Serial, and ATU-R Option
• Features - NB • Features - WB
• Load Coil detection
• Hazardous Potential • Bridged Taps Detection and location
• AC/DC Voltage • Noise 20kHz – 2MHz
• AC/DC Resistance (3 Term) • Filtered Wideband Noise with E
• Capacitance (3Term) (ISDN), F (SDSL) and G (ADSL) filters
• Capacitive Balance • Send a single frequency tone up to 2 MHz
• Longitudinal Balance at any level up to +26 dBm
• Filtered Narrowband Noise (C, and • Measure the frequency and level of a
Psophometric filters) broadband tone.
• Draw and Break dial tone from the CO • Impulse Noise
• Pair ID tone • Quiet and Restore NT1 and ADSL Modem
• Apply an AC tone to the loop
• Speech Detection
Broadband Services
Option
SONET Network
IAD
Public
SONET Network ATM EDGE Internet
DSLAM IP Core
Class 5
• Power Module
• Supplies power to all modules of the EDGE
chassis
• Accepts -48VDC input from back plane of
chassis
• Slides into the left side of the chassis as
shown
• Fan Module
• Cools the installed modules of the EDGE
• Mounts in the right side vertical slot as
shown
DigiTest EDGE
• Components of Telaccord1000
System
TOOLS
UNPACKING AND INSPECTION
• Recommended Tools
• Wire strippers
• Cable ties
• Test handset
• Screwdrivers (Phillips head and slotted)
• Wire wrap tool
• Punch down tool (for cross-connections)
• Voltmeter
• Switchboard wiring (#22 AWG [0.643 mm diameter] or #24 AWG [0.511 mm diameter])
• Power wiring (2 lengths, red and black, solid #18 AWG or 1.02 mm diameter preferred)
• Quiet ground wire, stranded, insulated, green (#12 AWG or 2.05 mm diameter [preferred], #18 AWG or
1.02 mm diameter [minimum])
• Chassis (frame) ground wire, stranded, insulated, green (#12 AWG or 2.05 mm diameter [preferred],
#18 AWG or 1.02 mm diameter [minimum])
• Grounding Strap
• Communications cabling – Serial Craft Cable (PC to Craft Port)
• Note: As connections are made, be sure to route all wiring across the front of the DigiTest
EDGE and then along the side. The notch in the mounting ear has a protective plastic guard over
which the wires are routed. The side of the DigiTest EDGE chassis has special lances to which
the cables can be attached using the wire ties provided in the accessory kit.
• Wiring the Access Server Ports
• Four asynchronous ports are configured independently
• Specifications of the ports are:
• Connection Type: RJ-45 connector
• Signals: GND, TX, RX, DTR, DCD, DSR, RTS, and CTS (Pins 1-8, respectively. Facing the
connector, pin 1 is on the right side.)
• Baud Rates: 300, 600, 1200, 2400, 4800, 9600, 19200 (default), 38400, 57600, and 115200
• Protection: ESD protection circuitry and EMI filters
• Data Bits: 7 or 8
•• Stop Bits 1, 1.5, or 2
Parity None, Odd, Mark, Even, or Space
• Connect the desired EDGE Serial Port to the desired serial device, routing the
cables across the front of the EDGE
• PINOUTS
• Wiring the DigiTest EDGE Serial port to
the ASAM DB-9 Serial Port
• Route the cables across the front and then along the side of the DigiTest EDGE
• For use of the EDGE TAP 1, the following pinout needs to be followed:
2 R (Silkscreen Label)
• Configuration Prerequisites
• Terminal Emulation
• Craft Terminal Configuration Settings:
• Control: Asynchronous control with hardware handshaking (DTR control)
• Baud Rate: 38,400
• Parity: None
• Data Bits: 8
• Stop Bits: 1
• CLI command prompt is: RAC>
• The DigiTest EDGE must be properly configured using a Craft Interface Device (CID) connected directly to
the Craft interface of the test platform. CIDs include a VT100 (or similar) ASCII terminal or a PC using a
terminal emulation program such as HyperTerminal
• The CLI includes a variety of commands that not only configure the DigiTest EDGE, but also perform set-up,
installation verification, and commissioning functions.
• Security Access Levels:
• Access to the Command Line Interface (CLI) is limited to users who have a valid login password
• Craft or Supervisor
• The craft password offers a subset of the functions of the supervisor.
• Use the ADD command to add entries to the router table. Any
number of router table entries may be created, but only four
may be created for serial ports 1 through 4. Note that these
four special ports are also shown in the PORT submenu as
DSLAM1, DSLAM2, DSLAM3, and DSLAM4 by default.
• To delete an entry in the router table, use the DELETE
command.
• To change an entry in the router table, use the MODIFY
command.
• Using the GATEWAY command, enter the IP address of the gateway device.
• To specify the subnet mask, begin by logging in to the DigiTest EDGE at a supervisor level.
• From the RAC> prompt of the Command Line Interface (CLI), use the ROUTER command to access the Router Menu.
• From the RAC:CAL> prompt, type the CALIB or CALINT command. This forces the DigiTest EDGE
to perform a calibration function.
• Installation/provisioning personnel should not reset calibration reference values.
• To display the results of the calibration, use the STATUS command.
• Diagnostic LED’s
• DigiTest EDGE has four tri-color
diagnostic LEDs that provide visual
indication of the test platform’s overall
status, enabling simple troubleshooting
by a technician.
• Each LED can assume a green, amber,
or red color in either a steady or blinking
state.
Troubleshooting Matrix
Installation
• Ground Connections
• There are three separate Ground connections on the
• TELACCORD 1000 chassis. They are CHASSIS, FRAME, and
GND.
• Chassis Ground
• This connection pad is located near spin wrap posts
labeled FRAME for protective ground connections. This
allows users to tie grounds together if this is their standard
practice.
• Frame (Protective Ground) Connection
• This is the ground providing a return path for all second
level surge protection.
• The spin wrap posts provided are located on the bottom pin
field (TO CENTRAL OFFICE) labeled FRAME.
• The user should connect using a minimum of #18 AWG
solid wire and spin wrap to post using 6 or more wraps.
• “GND” Ground Connection
• This Ground is for the office battery common for unit power.
• This is located on the TCC and MCC 5-pin spin wrap
connections.
• TAP Connections:
• The TCC provides connections to the Tip and Ring of TAP number 1. A spin-wrap connector is provided on
the TCC for this purpose.
• Connector pin designations are indicated by the silkscreen under the pin for the Tip and Ring connections
from the test head.
• Connection for the communications cable is provided by a 40-pin male ribbon connector, P6. Install the
communications cable (supplied with the accessory kit) in P6 with the “key” on the fifth keyed, 40-pin
female connector at the bottom, and the ribbon cable exiting from the top of the connector.
• Craft
• The Craft port is used to receive the TL1 messages.
• Connect an RJ-45 male connector in to J9 of the TCC. The
• following parameters are used.
• Baud rate: 19,200; Data bits: 8; Parity: None; Stop bits: 1
Ethernet
Craft Port
Serial Port
FRONT VIEW
Control Test Bus
Matrix Module Daisy Chain
Cards Comms
Daisy Chain
Alarms
TAP Input
Power
REAR VIEW
PROPRIETARY • TOLLGRADE AND AUTHORIZED CLIENTS ONLY
This document contains proprietary information that shall be distributed or
Backplane RJ-21
routed only within Tollgrade Communications, Inc. and its authorized
clients, except with written permission of Tollgrade. Connectors
MSAS Test Access - Advantages
• Small Footprint
• Very Price competitive
• Modular design; Grow as you go
• POTS Keep Alive Support for DSL testing
• Robust support for 2 or 4 wire testing for multiple customer architectures
• 2 Wire POTS/DSL Applications
• 4 Wire Special Services Applications
• NAR and ETSI Versions Available
• Configurable as Splitter only; Splitter w/Test access; Test access only
• Supports POTS, T1, HDSL, ADSL(2+), Special Circuits Services
• Support for Video services using splitter: Ring Trip negated; Crosstalk minimized
• Standard Connectorization
• RJ-45 for Comms; RJ-45 for Test Access; RJ-21 25 Pair In/Out for Services
POTS/DSL
CPE Public
Internet
Splitter/Access
POTS/DSL
CPE IP Core
DSLAM
PROPRIETARY • TOLLGRADE AND AUTHORIZED CLIENTS ONLY
This document contains proprietary information that shall be distributed or
routed only within Tollgrade Communications, Inc. and its authorized
clients, except with written permission of Tollgrade.
MSAS - Components
Component Description Part Number CLEI Code
Chassis Houses the functional cards TLGD-MSAS-CH VAMDR10MRA
Control Module Master Main control module in a system
occupying the far right slot of the TLGD-MSAS-CM-M VAUCAA8HAA
first chassis
Control Module Control module of chassis of a system TLGD-MSAS-CM-E VAUCAA9HAA
Extender of daisy chained MSAS located in
far right slot
NAR Splitter Module North American Splitter Card Only – 24 TLGD-MSAS-NASP VAUIAD4NAA
Only Port
NAR Splitter Module North American splitter card w/Test TLGD-MSAS-NASP-T VAUIAD7NAA
w/Test Access Access – 24 Port
ETSI Splitter Module International splitter card only – 24 Port TLGD-MSAS-ESPL VAUIAD5NAA
Only
ETSI Splitter Module International splitter card w/Test Access TLGD-MSAS-ESPL-T VAUIAD6NAA
w/Test Access – 24 Port
Access Matrix Module Two Wire POTS/DSL - 24 Port Test TLGD-MSAS-AMM-SB VAUCABAHAA
– Single Bus access only module w/ one test bus
Access Matrix Module Four Wire - 12 Port Test Access only- TLGD-MSAS-AMM-DB VAUCABBHAA
– Dual Bus two test buses
PROPRIETARY • TOLLGRADE AND AUTHORIZED CLIENTS ONLY
This document contains proprietary information that shall be distributed or
routed only within Tollgrade Communications, Inc. and its authorized
clients, except with written permission of Tollgrade.
Questions / Comments