You are on page 1of 18

FIU 19E indoor unit

For internal use


2 © Nokia Siemens Networks Presentation / Author / Date
FIU 19E – Indoor units for varying needs

FIU 19E is available as four different variants


• T55340.01 FIU19E with 2 active FB interfaces and SNMP
• T55340.02 FIU19E with 1 active FB interface and SNMP
• T55340.03 FIU19E with 2 active FB interfaces, no SNMP
• T55340.04 FIU19E with 1 active FB interface, no SNMP
• HW of the variants is the same, 2nd FB and SNMP can be upgraded later with SW
licenses

FIU 19E can be upgraded with the following SW licenses


• L55341.02 FIU19E SNMP license enabling IP DCN and OSPF
– Available for T55340.03 and T55340.04

• L55341.03 FIU19E license for 2nd FB interface for chain and OU protected sites
– Available for T55340.02 and T55340.04

• T55340.01 already offers 2nd FB and SNMP readily activated – no separate licenses
needed

For internal use


3 © Nokia Siemens Networks Presentation / Author / Date
FIU 19E features
•Support for TDM and Ethernet traffic transmission
•Flexible capacity management – transmission capacity via the flexbus interfaces is
independent of the number of equipped add/drop physical E1 interfaces.
•Integrated cross-connections between physical E1 interfaces and up to three flexbus
directions.
•Support for multiple protection methods (HSB, diversities)
•4x2M plug-in units for 75ohm and 120ohm
•Ethernet plug-in unit with L2 Switch (with QoS from SW rel C3.2 onwards)
•Flexbus plug-in unit – for 3rd and 4th FB interface (local interconnection or OU
connection)
•AUX plug-in unit e.g. for external alarms or user data
•DCN capacity 64 – 512 kb (2x2 – 16x2)
•Configuration, Fault and Performance Management via Q1 and SNMP
– currently NetAct not supporting FIU19E PM via IP DCN but only via Q1
•Enhanced Configuration back-up Compatibility
•IP based Engineering Order Wire
•Factory default settings

Note that even FIU 19E supports these features a separate Plug-in Unit or a license might be needed for
taking the feature into use.
For internal use
4 © Nokia Siemens Networks Presentation / Author / Date
FIU 19E plug-in units (PIU)
T55340.0x FIU 19E basic unit with three slots for plug-in units (PIU)

PIU slot1 PIU slot2 PIU slot3

T55220.02 (slots 1,2,3) T55220.03 (slots 1,2,3) T55320.01 (slot 2)


4x2Mbps unbalanced 75-ohm 4x2Mbps balanced 120-ohm Ethernet plug-in unit
SMB connectors RJ45 connectors RJ45 connectors

T55221.01 (slot 3) T55223.01 (slots 1,2,3)


Flexbus plug-in unit Aux data plug-in unit
TNC connectors RJ45 connectors

For internal use


5 © Nokia Siemens Networks Presentation / Author / Date
FIU 19E indoor unit – standalone 19’’
Supports up to 3 Flexbus (radio) directions:
Two Flexbus interfaces in the basic unit (directions 1 and 2)
Two more Flexbus interfaces available in Flexbus plug-in unit (direction 3)
Flexbus 4 available if protected ODU in Flexbuses 1 and 2 (one direction)
Modular structure – E1 and Ethernet interface plug-in units
Integrated cross-connections with E1 granularity via SW
Capacity sharing between E1 and Ethernet traffic with 2Mbps granularity

2/3 U

Plug-in-unit
Plug-in-unitinterface
interfacemodules:
modules:
•E1
•E1tributaries
tributaries(75
(75and 120)
and120 )
•Ethernet
•Ethernet
•Flexbus
•Flexbus3rd
3rdand
and4th
4th
•Auxiliary data channels
•Auxiliary data channels

4xE1 2xEthernet 4xE1


For internal use
6 © Nokia Siemens Networks Presentation / Author / Date
FIU 19E Interfacing
Basic
BasicFIU
FIU19E
19Eindoor
indoorunit
unitwith
with4x2Mbps
4x2Mbpsadd/dropp
add/droppinterface
interfaceplug-in
plug-in
unit
unitand
andEthernet
Ethernetplug-in
plug-inunit.
unit.

Four
FourE1E1 Two
Two10/100BaseT
10/100BaseT One
One10BaseT
10BaseT Two
TwoQ1 Q1
interfaces Ethernet SNMP
SNMPmanagement management
interfaces Ethernettraffic
traffic interface
management management
interfaces
interfaces interface interfaces
interfaces

Measurement
Measurementpoint
point

Local
Localmanagement
managementport
port
Power
Powerconnector
connector Two
TwoFlexbus
Flexbus
interfaces
interfaces
Alarm
Alarmstatus
statussummary
summaryLED
LED

For internal use


7 © Nokia Siemens Networks Presentation / Author / Date
IP EOW

Engineering Order Wire (known also as Service Telephone) to be


connected directly from FIU 19E SNMP interface, AUX data plug-in-unit
not needed
Based on commercial low cost IP telephone, local purchase

Needs IP DCN via FIU 19E or via site IP/TCP connection

For internal use


8 © Nokia Siemens Networks Presentation / Author / Date
Ordering FIU 19E 16x2 1+0
Order one of
• T55340.01 FIU19E 0x2M with SNMP & FB2
• T55340.02 FIU19E 0x2M with SNMP
• T55340.03 FIU19E 0x2M with FB2
• T55340.04 FIU19E 0x2M with 1 FB interface
And one of
• T55246.41 FIU 19(E) UPG TO 16X2M 1+0 75
• T55246.42 FIU 19(E) UPG TO 16X2M 1+0 120 RJ-45

For internal use


9 © Nokia Siemens Networks Presentation / Author / Date
Ordering FIU 19E 16x2 1+1
Order two of
• (T55340.01 FIU19E 0x2M with SNMP & FB2)
• T55340.02 FIU19E 0x2M with SNMP
• (T55340.03 FIU19E 0x2M with FB2)
• T55340.04 FIU19E 0x2M with 1 FB interface
And one of
• T55246.43 FIU 19E UPG EXU to 16X2M 1+1 75
• T55246.44 FIU 19E UPG EXU to 16X2M 1+1 120 RJ-45

Note! In 1+1 configuration the 2nd Flexbus interface of FIU 19E can not be used,
therefore no point of ordering units with activated 2 nd Flexbus interface (.01 and.03).

For internal use


10 © Nokia Siemens Networks Presentation / Author / Date
Ethernet support in FlexiHopper with FIU19E
How can you transport Ethernet FIU 19E
traffic?
• Ethernet plug-in unit in FIU19E
EPIU
E1s E1s
Eth 16 x 2Mbps
Eth

Key features
FB1 FB2
• Arbitrary mix of E1 and Ethernet traffic
FIU 19E
• Embedded L2 switch
• Ethernet QoS with SW release 3.2 EPIU
X
Value proposition 2M CC
L2
switch
• Easy upgrade of TDM installed base 4x2M
4x2M
PIU
PIU
• Fit for hybrid and Ethernet backhaul
• Compatible with FTFB unit for E1’s Eth-1 Eth-2
FlexiWCDMA BTS
For internal use
11 © Nokia Siemens Networks Presentation / Author / Date
FIU 19E Ethernet & TDM
Ethernet and TDM traffic types are handled separately
Radio capacity not allocated for Ethernet can be used for TDM
TDM cross-connections between
FIU 19E Indoor Unit
up to three radio directions
FB and physical E1 interfaces
4x2M FB3
PIU
Ethernet plug-in unit (EPIU):
E1’s
PIU
X Two Ethernet ports towards
2M CC radio directions and two local
FE interfaces
Ethernet
PIU
SIO1
FB1 Arbitrary capacity mix between
Eth1
Ethernet and TDM traffic with
SIO2 2Mbps granularity towards
Eth2 FB2
flexbus interfaces
Ethernet capacity over the radio
hop up to 32Mbps per
Flexbus (max if no TDM used)

E1’s Eth1&2 FB3 FB1&2


For internal use
12 © Nokia Siemens Networks Presentation / Author / Date
SW release 3.2 for FIU19E FIU 19E 3.2 with EPIU
QoS requires Hopper
Manager rel 4.12

• Enables the use of Quality of Service (QoS) with Ethernet

• No HW changes for FIU 19E or Ethernet Plug-in Unit


– SW Release 3.2 can be upgraded to all existing rel 2.0 and newer FIU 19Es

• Two operating modes with Ethernet Plug-in unit


– Classic Mode (same functionality as today – no QoS)
– QoS Mode (EPIU operates as a Full Switch with QoS)
– Operating mode is selectable by the user

Existing
ExistingFIU
FIU19E
19E&&Ethernet
Ethernet
••3.2
3.2SW
SWUpgrade
Upgrade Plug-in Unit (EPIU)
Plug-in Unit (EPIU)
••QoS
QoSLicense
License

For internal use


13 © Nokia Siemens Networks Presentation / Author / Date
Classic Mode – Sub operating modes
Ethernet Channel Separation (Available only in
Classic Mode) Ethernet
SIO1
• Two independent Ethernet data channels over two radio links Eth1
PIU FB1
(Eth1 to SIO1 (in FB1), Eth2 to SIO2 (in FB2)
• Both Ethernet interfaces passed to own radio outdoor unit SIO2
Eth2 FB2
• Ethernet data channels are configured independently

Ethernet Capacity Sharing (Available only in


Ethernet
Classic Mode) PIU SIO1
Eth1 FB1
• Two individual Ethernet data channels over one radio link (Eth1
and Eth2 to SIO1 (in FB1) or SIO2 (in FB2)
• Flexible sharing of radio path capacity between two Ethernet Eth2
data channels

Ethernet Full Switch (Available in Classic and Ethernet


QoS Modes) PIU SIO1
Eth1 FB1
• EPIU operates as a four port L2 Ethernet Switch (The ports
being Eth1, Eth2, SIO1 (in FB1) and SIO2 (in FB2) SIO2
• Traffic from any input ports can be forwarded to any output port Eth2 FB2
• Ethernet interface unit learns up to 2048 MAC addresses
• Packet forwarding based on MAC addresses
For internal use
14 © Nokia Siemens Networks Presentation / Author / Date
QoS mode - Features Eth1
Ethernet PIU
SIO1
FB1 Operates
always as a
• VLAN aware switching (802.1Q) Eth2
SIO2
FB2 Full Switch
– Configurable VLAN membership/port (64
different VLAN IDs per unit)
Four queues/direction

• VLAN P-bits based prioritization


(802.1p)
SIO

• 4 queues/radio direction
Strict Priority

• Scheduling choices
1. Weighted Fair Queuing (WFQ) with
weights fixed to 8, 4, 2, 1 Four queues/direction
2. Strict Priority

• In QoS Mode the EPIU operates WFQ SIO


always as a full switch
Weighted Fair
Queuing
• 256kB memory dynamically
allocated between the buffer
For internal use
15 © Nokia Siemens Networks Presentation / Author / Date
EPIU QoS settings
Class of Service window VLAN window

Activate QoS Mode

Select Scheduling
- SP or
- WFQ VLAN ID entries
-max 64 per unit
Priority Remapping

Default Priority
- For untagged frames
Default VLAN ID
- For untagged frames

VLAN membership per port


Modify Priority Remapping
Factory default

For internal use


16 © Nokia Siemens Networks Presentation / Author / Date
Example: Connections in Hybrid Backhaul

Tail Site Chain Site


TDM TDM

Eth Eth

FIU 19E FIU 19E


TDM Cross-
Connect
X
EPIU EPIU
Ethernet L2
X Switch with
2M CC 2M CC
QoS
4x2M
4x2M 4x2M
PIU PIU
E1 Eth E1 Eth

FTIB E1 Eth FTIB E1 Eth

FlexiBTS System Module FlexiBTS System Module

For internal use


17 © Nokia Siemens Networks Presentation / Author / Date
Thank You

For internal use


18 © Nokia Siemens Networks Presentation / Author / Date

You might also like