Professional Documents
Culture Documents
com
www.raisecom.com
/
Three Condition
Ethernet Cable
IP Default ONT
IP laptop
192.168.1.1
192.168.1.xx/24
www.raisecom.com /
1. Solution for first condition Connect to ADTRAN OLT(swap from 3.018
to 3.0.5)
Ethernet Cable
IP Default ONT
IP laptop
192.168.1.1
192.168.1.xx/24
www.raisecom.com /
1. Solution for first condition Connect to ADTRAN OLT(swap from 3.018 to
3.0.5)
1. nv getenv sw_active
Mean to know current running
firmware, current is 1
2. nv getenv sw_version0/sw_version1
Mean to know firmware version of
firmware 0 and 1
3. nv setenv sw_commit o
Mean to change from firmware 1 to
firmware 0
4. Reboot
Reboot the ont to take effect changing
firmware
www.raisecom.com /
1. Solution for first condition Connect to ADTRAN OLT(swap from 3.018 to
3.0.5)
5. nv getenv sw_active
Check again after reboot
process is done, now current
firmware I change from 1 to 0
www.raisecom.com /
1. Solution for first condition Connect to ADTRAN OLT(swap from 3.018 to
3.0.5)
Firmware 3.0.5
already success swap
www.raisecom.com /
2 Solution for second condition Connect to ADTRAN OLT (inject firmware
3.0.5 to ONT)
www.raisecom.com /
2. Solution for second condition Connect to ADTRAN OLT (inject firmware
3.0.5 to ONT)
Ethernet Cable
IP Default ONT
IP laptop
192.168.1.1
192.168.1.xx/24
www.raisecom.com /
2. Solution for second condition Connect to ADTRAN OLT (inject firmware
3.0.5 to ONT)
Login : telecomadmin
Password : q!w@e#
www.raisecom.com /
2. Solution for second condition Connect to ADTRAN OLT (inject firmware
3.0.5 to ONT)
1. Choose Admin
2. Choose Firmware
Upgrade
www.raisecom.com /
2. Solution for second condition Connect to ADTRAN OLT (inject firmware
3.0.5 to ONT)
4. Choose Upgrade
5. Choose OK
www.raisecom.com /
2. Solution for second condition (inject firmware 3.0.5 to ONT)
6. Wait until
procces end
8. Firmware 3.0.5
already success
inject to ONT
www.raisecom.com /
www.raisecom.com /