You are on page 1of 13

Competitive Analysis

Electric Power
C175
Package Generator Set
Competitive Analysis

Competitive Comparison
Product Comparison Format

Green in the Cat column implies that Cat is better than


all the listed competitors for the specified criteria.

Red in the Cat column implies there is at least one


competitor with an advantage for the specified criteria.

Black in the Cat column implies there is at least one


competitor equal to Cat for the specified criteria.

One company.™ A multitude of solutions.


C175
Competitive Analysis

Electric Power
C175-16
Standby
3100ekW - Without Fan Rating
Tier 2
Package Generator Set
C175 – Standby 3100 ekW: Without Fan (Tier 2)

Without Fan Rating:


• Generator set package is not configured/rated for an engine driven radiator
• A remote radiator or cooling tower is required to meet engine cooling
requirements
• Power consumption by an electrically driven fan drive will reduce the
system’s net/exportable power below the ‘3100 ekW w/o Fan’ generator
nameplate rating
• (3100 ekW w/o Fan) – (Electrical Fan Power) = Net/Exportable Power
• A electrically driven, horizontal remote radiator is offered as an option from
the Caterpillar factory

One company.™ A multitude of solutions.


C175 – Standby 3100 ekW: Without Fan (Tier 2)

C175-16 Standby 3100 ekW w/o Fan (Tier 2)

Vs

Katolight Standby 3000 ekW Ratings (Tier 2)


MTU/DD Standby 3000 ekW Ratings (Tier 2)

One company.™ A multitude of solutions.


C175 – Standby 3100 ekW: Without Fan (Tier 2)

Package Data
Caterpillar Katolight MTU/DD
Model # CD3000-X6T2
Engine C175-16 20V-4000 G83L 20V4000 G83L
Engine Manufacturer Caterpillar MTU MTU
Packager Caterpillar Katolight MTU/DD
Rating (ekW) 3100 3000 3000
Rating (kVA) 3875 3750 3750
Bore (mm) 175 170 170
Stroke (mm) 220 210 210
Number of Cylinders 16 20 20
Displacement (L) 84.67 Remote w/ Rad 95.4 95.4
Compression Ratio 15.3:1 Radiator C175-16 16.5:1 16.5:1
Minimum Package Weight (kg) 18800 * 5455 ** 24255 ** 27,466 27,466
Package Minimum Length (mm) 6464.7 * 4721.6 11186.3 7780 7780
Package Minimum Height (mm) 2211.1 * 2092 2211.1 3310 3310
Package Minimum Width (mm) 2089.4 * 2285.6 2285.6 2900 2900
Min Footprint (m 2) *** 13.51 10.79 24.30 22.56 22.56

W/ Radiator Dimensions (units assumed end to end) * Without Radiator – Data not comparable
Weight and Length - added together
Height and Width – largest b/w engine & radiator ** Weight does not include customer supplied connecting lines
*** Min Footprint does not include space needed to service components

One company.™ A multitude of solutions.


C175 – Standby 3100 ekW: Without Fan (Tier 2)

Engine Attachments

Caterpillar Katolight MTU/DD


Engine C175-16 20V-4000 G83L 20V4000 G83L
Rating (eKW) 3100 3000 3000
Rating (kVA) 3875 3750 3750
Standard Air Cleaner Reg Duty * Reg Duty Reg Duty
Air Cleaner Service Indicator Standard Optional Info Not Avail
Oil Filter Type Canister Spin-on Full Flow
Standard Isolators Rubber Pad Info Not Avail
Optional Isolators Spring Spring Spring
Charging Alternator Optional Info Not Avail Standard
Batteries Standard Optional Info Not Avail

* Cat Regular Duty - Single Element, 4x Single Element Air Cleaners


- Includes service indicator

One company.™ A multitude of solutions.


C175 – Standby 3100 ekW: Without Fan (Tier 2)

Cooling System
Caterpillar Katolight MTU/DD
Engine C175-16 20V-4000 G83L 20V4000 G83L
Rating (ekW) 3100 3250 3250
Rating (kVA) 3875 3750 3750
Aspiration TA TA TA
Radiator Type Remote Package Mounted Package Mounted
Coolant to Aftercooler Temp Max (°C) 46 * 50** 50**
Ambient Capability at 300m (°C) 43 47 47
Maximum Radiator External Restriction kPA (H20) 0.25 (1.0 ) 0.12 (0.5) 0.12 (0.5)
1166 +
Total Coolant Capacity (L) Customer Supp Lines*** 1081 1074

* Max SCAC temp provided is at 30C ambient. At ambients over 30C, the SCAC temp should not
exceed 16C above ambient
** Information obtained from previous MTU spec sheet (Series 4000-03)
MTU data originally on 25°C day. Data adjusted to 30C ambient for comparison with Caterpillar

One company.™ A multitude of solutions.


C175 – Standby 3100 ekW: Without Fan (Tier 2)

Heat Rejection

Caterpillar Katolight MTU/DD


Engine C175-16 20V-4000 G83L 20V4000 G83L
Rating (ekW) 3100 3000 3000
Rating (kVA) 3875 3750 3750
Heat Rejection to Coolant (kW) 1365 1339 1339
Heat Rejection to Exhaust (kW) 3081 Info Not Avail Info Not Avail
Heat Rejection to After Cooler (kW) 487.5 999 999
Heat Rejected to Atmosphere from Engine (kW) 269 Info Not Avail Info Not Avail
Heat Rejection to Atmosphere from Generator (kW) 115.3 Info Not Avail Info Not Avail
Total Heat Rejected to Atmosphere (kW) 384.3 225 225
Max JW Outlet Temperature (C ) 99 100 100
Engine Power Deration (up to) 750m at 43°C 1500 at 25°C 1500 at 25°C

One company.™ A multitude of solutions.


C175 – Standby 3100 ekW: Without Fan (Tier 2)

Generator

Caterpillar Katolight MTU/DD


Engine C175-16 20V-4000 G83L 20V4000 G83L
Rating (eKW) 3100 3000 3000
Rating (kVA) 3875 3750 3750
Number of Bearings on Gen 2 2 2
Excitation PM PM PM
Winding Type Form Random Form
Insulation LV/MV Class H Class H Class F
Temp Rise LV/MV 150 deg C 150 deg C 130 deg C
Voltage Regulator Digital Digital Digital
Pitch 2/3 2/3 2/3
Space Heater Optional Optional Info Not Avail
Winding RTD Optional Info Not Avail Info Not Avail
Bearing RTD Optional Info Not Avail Info Not Avail
Motor Starting Capability (skVA)*** 8628 Info Not Avail 6400

* CAT publishes skVA at 30% volt dip and 0.4 pf


MTU publishes skVA at 30% voltage dip and 0.8 pf

One company.™ A multitude of solutions.


C175 – Standby 3100 ekW: Without Fan (Tier 2)
60 Hz Standby Duty
* With Remote Radiator
Caterpillar Katolight MTU/DD
Engine C175-16 20V-4000 G83L 20V4000 G83L
Rating (ekW) 3100 3000 3000
Rating (kVA) 3875 3750 3750
Power Drawn from Remote Fan (ekW) 90
Exportable Power (ekW) * 3010 3000 3000
RPM 1800 1800 1800
Emissions Compliance US EPA Tier 2 US EPA Tier 2 US EPA Tier 2
Power Density (ekW/L) 35.55 31.45 31.45
Air Flow Required for Rad. Cooled Unit (m3/min) 3256 4022 4022
Fuel Consumption @100% Rating (L/Hr) 798 803 803
Fuel Consumption @75% Rating (L/Hr) 605 591 591
Fuel Consumption @50% Rating (L/Hr) 474 409 409
Air Flow Required for Rad. Cooled Unit (m3/min)/kW ** 1.08 1.34 1.34
Fuel Consumption @100% Rating (L/Hr)/kW** 0.265 0.268 0.268
Fuel Consumption @75% Rating (L/Hr)/kW** 0.201 0.197 0.197
Fuel Consumption @50% Rating (L/Hr)/kW** 0.157 0.136 0.136

* Includes adjustment for remote fan parasitic


losses
** Calculation based on exportable power

One company.™ A multitude of solutions.


C175 – Standby 3100 ekW: Without Fan (Tier 2)

Exhaust System

Caterpillar Katolight MTU/DD


Engine C175-16 20V-4000 G83L 20V4000 G83L
Rating (ekW) 3100 3000 3000
Rating (kVA) 3875 3750 3750
Exhaust Gas Temp. (°C) 460 545 545
Exhaust Gas Flow (m 3/min) 676 708 708
Exhaust System Backpressure (max allowable) kPa (H2O) 6.7 (27) 8.5 (34.1) 8.5 (34.1)