You are on page 1of 29

HyBase 6100

HyBase 6100
Electro-Hydraulic Operating Table

2
HyBase 6100

 Max. lifting capacity up to 380kg with highest safety and stability

 Max. safe working load 275kg in normal position

 Longitudinal slide up to 320 mm for free access to C-arm

 498 mm lowest table position for Neurosurgery and Minimally Invasive Surgery

 Multi-layer decompression pad with waterproof and seamless design

 Wireless remote control system

 Foot pump Manual Override System

3
Outstanding Versatility for All Surgeries
 Lowest Table Height Up to 498mm

With the need of minimally invasive surgery and neurosurgery, lowest table height becomes the k
ey to providing a more comfortable and better ergonomic working environment for surgeons.

498mm

4
Outstanding Versatility for All Surgeries
 Height Adjustment Up to 502 mm

To maximize the flexibility, height adjustment up to 502mm makes it optimal for table’s v
ersatile positions, especially helpful for orthopedics surgeries, etc.

1,000mm

5
Outstanding Versatility for All Surgeries
 Built-in Kidney Bridge

HyBase 6100 provides a built-in kidney bridge(120mm) for kidney surgery.

6
Excellent C-arm Access for Imaging
 Large Longitudinal Slide up to 320 mm

With longitudinal slide up to 320 mm, HyBase 6100 enables optimum access to the C-ar
m without repositioning the patient for imaging purpose, ideally suitable for cardiovascul
ar or spinal surgery.

320mm

7
Excellent C-arm Access for Imaging
 Interchangeable Head Plate and Leg Plates

With interchangeable head plate and leg plates, the table top is able to maximum imaging space
up to 1,400mm for cardiovascular or spinal surgery.
The whole table top is made from radiolucent material and without any metal cross-bar for radi
oscopy. What’s more, the optional carbon fiber table top guarantees a better imaging solution.

1,400mm

1,000mm

8
Easy to Use
 One-Click Button Design

With convenient One-Click Button Design, it’s easier to remove or assembly the head and
leg plates.

plates.

9
Easy to Use
 Wireless Remote Control

1. Break system

2. Back plate up and down

3. Tilt left and right

5. Trendelenburg and Reverse Trendelenburg

6. Table up and down

7. Table top sliding (for slide version)

10
Easy to Use
 Hand control holding on the head plate design and Foot Switch is conve
nient for anesthesia doctors and surgeons adjust the table during the
surgery.

11
Easy to Use
 More Space for Surgeons

The u shape design on base cover forms a larger space for surgeons while doing the oper
ations, especially for gynecologic, urologic, etc..

12
Maximum Safety
 Standard Built-in Battery and Backup Control System

With two standard built-in batteries, the table can support approximately 60 to 80 surger
ies. There’s also a backup control system on the column for use.

13
Maximum Safety
 Manual Override System

Manual Override System is easily access at any time and allows table articulation movem
ents and release the break in the event of primary control or power malfunction.

Step 2:
Step 1:
Step on foot pump and press the hand control
Turn the nob clockwise to enter the Manual
simultaneously to start the articulation
Override System mode.
movements.

14
Maximum Safety
 Multi-layer Decompression Pad

With the Special Foam Core pad and multi-layer design, HyBase 6100 provides excellent pres
sure distribution, significantly helping patients avoid the main cause of decubitus, reduce the
rate of postoperative health risk. Meanwhile, the pad is waterproof and easy to clean as it’s
with ultrasonically-welded technology and GORE-TEX material.

75mm

15
Flexible Patient Positioning

Neurosurgery

Lowest table height with Skull Clamp Beach chair position for Neurosurgery
(DORO ) for Neurosurgery

16
Flexible Patient Positioning

ENT Surgery Ophthalmology Surgery

17
Flexible Patient Positioning

Orthopedic and Trauma Surgery

Orthopedic Surgery Orthopedic Surgery for Orthopedic Surgery for


lateral femoral extension tibia extension

18
Flexible Patient Positioning

Orthopedic and Trauma Surgery

Spinal Surgery Spinal Surgery

19
Flexible Patient Positioning

Orthopedic and Trauma Surgery

Knee Arthroscopy Surgery Knee Arthroscopy Surgery

20
Flexible Patient Positioning

Orthopedic and Trauma Surgery

Forearm Surgery Upper arm Surgery

21
Flexible Patient Positioning

Orthopedic and Trauma Surgery

Arm Surgery Upper arm Surgery

22
Flexible Patient Positioning

Struma Surgery General Surgery

23
Flexible Patient Positioning

Gynecology and Urology

The leg plate folded design helps avoiding the disassembly of Ergonomic lithotomy position with stirrups
the leg plate while surgeons operate the gynecology, urology,
etc. surgeries. And the u shape design on base cover forms a
larger space for surgeons while doing the operations.

24
Flexible Patient Positioning

Kidney Surgery Laparoscope Surgery

25
Flexible Patient Positioning

Proctology Surgery

26
Main Difference
  HyBase 6100 HyBase 6100
Standard Configuration Plus Configuration
Table height (without pad) Standard height: 600-950mm Ultra-low height: 498mm-1,000mm
Longitudinal slide Optional Optional
Kidney bridge Optional Optional
Manual override No Optional

HyBase 6100 HyBase 6100


Standard Configuration Plus Configuration

27
Technical Specifications

28
Thanks for your
attention!

healthcare within reach

You might also like