IPAC 5.5 TR Drop Test

©2015 Johnson Controls - Hitachi Air Conditioning


Model description

2
1

100mm lifted

Model

1.MOTOR: 10 Kg
2.CONTROLLER BOX: 7.0 Kg
3.HEX: 11Kg
4.COMP. WEIGHT ZPV038DE-4X9: 20.8Kg

Mesh model
Results

Displacement
89.4mm

Plastic strain 0.04


Stress value 295 MPa
Results

Stress 204MPa
Plastic strain 0.02

Stress 295MPa
Plastic strain 0.02
Stress 175MPa
Results Plastic strain 0.001

Stress 207MPa
Stress 192MPa Plastic strain 0.03
Plastic strain 0.007
Results

Stress 171.5MPa
Plastic strain 0.009

Stress 183.5MPa
Plastic strain 0.03
Results

Stress 160MPa Stress 110MPa

Conclusion :
In many cases stress value is very low and below 184 MPa,on the other side
stress value is higher is only near screw and edges highlighted in all slides

In slide 6 stress value is low but stress is distributed in higher area and the part is
displaced a bit from the position so need to add screw near highlighted area