You are on page 1of 56

AGRICULTURAL STRUCTURES – CARABAO FEEDLOT

PAES 408:2001
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

area with its physical facilities used for carabao fattening


PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

area with its physical facilities used for carabao fattening

 feedlot
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Philippine water buffalo or swamp buffalo


PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Philippine water buffalo or swamp buffalo

 carabao
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The minimum space requirement shall be_____.


PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The minimum space requirement shall be_____.

 4 m2/animal
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Concrete floors shall be skid resistant. The minimum floor thickness shall be ____with ____slope
towards the drainage.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Concrete floors shall be skid resistant. The minimum floor thickness shall be ____with ____slope
towards the drainage.

 76 mm, 2 - 4%
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

If the floor is earth lot, it shall have a slope of_____.


PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

If the floor is earth lot, it shall have a slope of_____.

 4 - 7%
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The roof slope shall not be less than____.


PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The roof slope shall not be less than____.

 25%
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

If roofing is made of indigenous materials, the minimum roof slope shall be____.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

If roofing is made of indigenous materials, the minimum roof slope shall be____.

 58%
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The minimum height of the top of the roof beam shall be ___m from the floor.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The minimum height of the top of the roof beam shall be ___m from the floor.

 2.5
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Pen walling and post shall be preferably made of G.I. pipes schedule 40. The diameter of vertical
and horizontal railing member of the pen wall shall be at least ______for the post.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Pen walling and post shall be preferably made of G.I. pipes schedule 40. The diameter of vertical
and horizontal railing member of the pen wall shall be at least ______for the post.

 50 mm and 75 mm
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The maximum center to center spacing between post shall be ____and shall be embedded in a
concrete pedestal with a minimum depth of 0.4 m.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The maximum center to center spacing between post shall be ____and shall be embedded in a
concrete pedestal with a minimum depth of 0.4 m.

 1.5 m, 0.4m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Each post shall be provided with ____concrete protectors.


PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Each post shall be provided with ____concrete protectors.

 0.15m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The pen shall be ____high.


PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The pen shall be ____high.

 1.2 m – 1.5 m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The dimension of the feed trough should be ____ m depth, ______bottom width and _____top
width.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The dimension of the feed trough should be ____ m depth, ______bottom width and _____top
width.

 be 0.4 m depth, 0.45 m – 0.7 m bottom width and 0.7 m – 0.9 m top width.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The bed of the trough should be ____above the level of the apron to facilitate natural feeding
stance.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The bed of the trough should be ____above the level of the apron to facilitate natural feeding
stance.

 150 mm
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The minimum space requirement for feeding shall be_______.


PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The minimum space requirement for feeding shall be_______.

 0.750 mm/animal
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Restraining horizontal rail shall be provided to prevent the animals from stepping into the trough.
This rail shall be ______from the floor supported by the post spaced at 1 m.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Restraining horizontal rail shall be provided to prevent the animals from stepping into the trough.
This rail shall be ______from the floor supported by the post spaced at 1 m.

 1m - 1.2 m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The water troughs should be provided with concrete or gravel packed aprons to improve sanitation
and keep the water clean, if the pen has an earth floor. Minimum length of concrete aprons shall
be____.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The water troughs should be provided with concrete or gravel packed aprons to improve sanitation
and keep the water clean, if the pen has an earth floor. Minimum length of concrete aprons shall
be____.

 1.5 m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The open water tank space shall be at least ___for every 10 heads.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The open water tank space shall be at least ___for every 10 heads.

 0.3 m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The housing shall be provided with lighting intensity of_____.


PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The housing shall be provided with lighting intensity of_____.

 200 lux
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Loading chute should be provided and should be oriented so as to minimize the effect of bright
sunlight. The width shall be______.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Loading chute should be provided and should be oriented so as to minimize the effect of bright
sunlight. The width shall be______.

 0.66 m – 0.76 m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Loading ramp floor shall have cross battens every ____to prevent slipping.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Loading ramp floor shall have cross battens every ____to prevent slipping.

 0.2 m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Ramp should have a slope of____.


PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

Ramp should have a slope of____.

 30%
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The slope of the permanently installed ramp shall not exceed____.


PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The slope of the permanently installed ramp shall not exceed____.

 36%
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

For portable or adjustable loading chute, slope shall not exceed____.


PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

For portable or adjustable loading chute, slope shall not exceed____.

 47%
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

If stair-stepped concrete ramps are provided, each step should have ___ mm – ___mm rise and ___
mm tread width. The step surface shall be roughened.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

If stair-stepped concrete ramps are provided, each step should have ___ mm – ___mm rise and ___
mm tread width. The step surface shall be roughened.

 90 mm – 100 mm rise and 300 mm tread width


PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The central alley or the driveway should be elevated and shall have a minimum width of ___if
vehicles are allowed to enter within the building and it shall have a solid base.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The central alley or the driveway should be elevated and shall have a minimum width of ___if
vehicles are allowed to enter within the building and it shall have a solid base.

 3m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The gutter shall have a minimum width of ____ m and a minimum depth of ____m.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot

The gutter shall have a minimum width of ____ m and a minimum depth of ____m.

 minimum width of 0.46 m and a minimum depth of 0.2 m

You might also like