Professional Documents
Culture Documents
PAES 408:2001
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
feedlot
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
carabao
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
4 m2/animal
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
Concrete floors shall be skid resistant. The minimum floor thickness shall be ____with ____slope
towards the drainage.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
Concrete floors shall be skid resistant. The minimum floor thickness shall be ____with ____slope
towards the drainage.
76 mm, 2 - 4%
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
4 - 7%
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
25%
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
If roofing is made of indigenous materials, the minimum roof slope shall be____.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
If roofing is made of indigenous materials, the minimum roof slope shall be____.
58%
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The minimum height of the top of the roof beam shall be ___m from the floor.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The minimum height of the top of the roof beam shall be ___m from the floor.
2.5
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
Pen walling and post shall be preferably made of G.I. pipes schedule 40. The diameter of vertical
and horizontal railing member of the pen wall shall be at least ______for the post.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
Pen walling and post shall be preferably made of G.I. pipes schedule 40. The diameter of vertical
and horizontal railing member of the pen wall shall be at least ______for the post.
50 mm and 75 mm
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The maximum center to center spacing between post shall be ____and shall be embedded in a
concrete pedestal with a minimum depth of 0.4 m.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The maximum center to center spacing between post shall be ____and shall be embedded in a
concrete pedestal with a minimum depth of 0.4 m.
1.5 m, 0.4m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
0.15m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
1.2 m – 1.5 m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The dimension of the feed trough should be ____ m depth, ______bottom width and _____top
width.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The dimension of the feed trough should be ____ m depth, ______bottom width and _____top
width.
be 0.4 m depth, 0.45 m – 0.7 m bottom width and 0.7 m – 0.9 m top width.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The bed of the trough should be ____above the level of the apron to facilitate natural feeding
stance.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The bed of the trough should be ____above the level of the apron to facilitate natural feeding
stance.
150 mm
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
0.750 mm/animal
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
Restraining horizontal rail shall be provided to prevent the animals from stepping into the trough.
This rail shall be ______from the floor supported by the post spaced at 1 m.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
Restraining horizontal rail shall be provided to prevent the animals from stepping into the trough.
This rail shall be ______from the floor supported by the post spaced at 1 m.
1m - 1.2 m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The water troughs should be provided with concrete or gravel packed aprons to improve sanitation
and keep the water clean, if the pen has an earth floor. Minimum length of concrete aprons shall
be____.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The water troughs should be provided with concrete or gravel packed aprons to improve sanitation
and keep the water clean, if the pen has an earth floor. Minimum length of concrete aprons shall
be____.
1.5 m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The open water tank space shall be at least ___for every 10 heads.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The open water tank space shall be at least ___for every 10 heads.
0.3 m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
200 lux
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
Loading chute should be provided and should be oriented so as to minimize the effect of bright
sunlight. The width shall be______.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
Loading chute should be provided and should be oriented so as to minimize the effect of bright
sunlight. The width shall be______.
0.66 m – 0.76 m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
Loading ramp floor shall have cross battens every ____to prevent slipping.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
Loading ramp floor shall have cross battens every ____to prevent slipping.
0.2 m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
30%
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
36%
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
47%
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
If stair-stepped concrete ramps are provided, each step should have ___ mm – ___mm rise and ___
mm tread width. The step surface shall be roughened.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
If stair-stepped concrete ramps are provided, each step should have ___ mm – ___mm rise and ___
mm tread width. The step surface shall be roughened.
The central alley or the driveway should be elevated and shall have a minimum width of ___if
vehicles are allowed to enter within the building and it shall have a solid base.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The central alley or the driveway should be elevated and shall have a minimum width of ___if
vehicles are allowed to enter within the building and it shall have a solid base.
3m
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The gutter shall have a minimum width of ____ m and a minimum depth of ____m.
PAES 408: 2001 - Agricultural Structures – Carabao Feedlot
The gutter shall have a minimum width of ____ m and a minimum depth of ____m.