The document outlines the specifications for a Multi Section Digital Axle Counter (MSDAC) system as per RDSO specifications 176/2013. The key points are:
1. The MSDAC system comprises of axle detectors, field units, a central evaluator, reset unit, relay unit, and event logger to support detection points across multiple track sections.
2. The central evaluator connects to field units in a star configuration and each track section can be independently reset.
3. The system is required to work on various Indian rail traction systems and with a DC power supply of 24V.
4. The system is required to pass various inspection and testing criteria including climatic, shock, high voltage
The document outlines the specifications for a Multi Section Digital Axle Counter (MSDAC) system as per RDSO specifications 176/2013. The key points are:
1. The MSDAC system comprises of axle detectors, field units, a central evaluator, reset unit, relay unit, and event logger to support detection points across multiple track sections.
2. The central evaluator connects to field units in a star configuration and each track section can be independently reset.
3. The system is required to work on various Indian rail traction systems and with a DC power supply of 24V.
4. The system is required to pass various inspection and testing criteria including climatic, shock, high voltage
The document outlines the specifications for a Multi Section Digital Axle Counter (MSDAC) system as per RDSO specifications 176/2013. The key points are:
1. The MSDAC system comprises of axle detectors, field units, a central evaluator, reset unit, relay unit, and event logger to support detection points across multiple track sections.
2. The central evaluator connects to field units in a star configuration and each track section can be independently reset.
3. The system is required to work on various Indian rail traction systems and with a DC power supply of 24V.
4. The system is required to pass various inspection and testing criteria including climatic, shock, high voltage
(VERSION:3.0) MULTI SECTION DIGITAL AXLE COUNTER(MSDAC) System Requirements The MSDAC system comprises of Axle Detectors, DAC field units, Central Evaluator, Reset unit, Relay unit, Event Logger and diagnostic terminal. It shall support detection points and generate vital relay outputs for requisite track sections as per the users requirement. The Central Evaluator shall be connected to DAC field units in star configuration. Each track section can be reset independently from the Reset Box/Reset Module of Reset Panel. The Event Logger shall record all the events occurring in the multiple section digital axle counter. MSDAC INTERCONNECTION BLOCK DIAGRAM GENERAL REQUIREMENTS • MSDAC SHALL BE CONFIGURED FOR DESIRED TRACK SECTIONS AS PER THE USER’S REQUIREMENT/SITE SPECIFIC CONDITION. • CENTRAL EVALUATOR MAY BE CONNECTED TO DETECTION POINTS ON 2 WIRE ARRANGEMENTS OR 4WIRE ARRANGEMENTS MAY BE PROVIDED TO REDUCE TRACK SIDE ELECTRONICS CONSIDERABLY. • TROLLEY PROTECTION TRACK CIRCUIT SHALL NOT BE REQUIRED WITH PHASE DETECTION. • AXLE COUNTER SHALL BE SUITABLE FOR TRAIN SPEEDS FROM 0 TO250KMPH. • CARD WISE FAILURE INDICATION SHALL BE PROVIDED IN CENTRAL EVALUATOR AND ALSO TOTAL SYSTEM FAILURE&O.K.INDICATIONS SHALL BE PROVIDED. • RESPONSE TIME OF TRAIN OCCUPANCY SHALL BE LESS THAN 1.0 SEC&CLEARENCE OF ANY TRACK SECTION AFTER TRAIN LEAVES THE SECTION SHALL BE LESS THAN2.5 SEC. GENERAL REQUIREMENTS
• AXLE COUNTER SHALL WITH STAND THE EFFECT OF LIGHTNING&SURGES
AS PER RDSO/SPN/144. • THE EQUIPMENT SHALL CONFIRM TO THE SAFETY INTEGRETY LEVEL 4 AS PER CENELEC STANDARD. • AXLE COUNTER SHALL HAVE THE A.C. IMMUNITY LEVEL OF 400V AC,50HZ INDUCED ON THE QUAD CABLE. • MSDAC SHALL HAVE 2 OUT OF 2 ARCHITECTURE. • PROVISION OF EARTHING SHOULD BE THERE IN THE CENTRAL EVALUATOR,FIELD UNIT AND RESET BOX.THE EARTH TERMINAL SHALL BE SUITABLE FOR TAKING UPTO 4mm dia COPPER WIRE WITH LUG. • THE EVENT LOGGER SHALL BE INBUILT IN THE CENTRAL EVALUATOR
• DIAGNOSTIC SYSTEM SHALL HAVE THE AXLE COUNTER SYSTEM.
TRACTION AND SUPPLY • AXLE COUNTER SYSTEM SHALL BE CAPABLE OF WORKING IN ALL SECTIONS OF • -NON RE AREA • -A.C. RE AREA: 25KV AC,50HZ,1000A • -D.C RE AREA :1.5 KV DC,6000A • -D.C RE AREA: 750V DC DC INPUT POWER SUPPLY • THE FIELD UNIT SHALL WORKWITHPOWER SUPPLY OF24VDC FED FROM REMOTE LOCATION
• THE INPUT VOLTAGE RANGE IS +24VDC(+20%to-30%)
• THE CENTRAL EVALUATOR SHALL WORK WITH 24VDC POWER SUPPLY BUT THE RANGE WILL BE +20%,-10%
• THE POWER CONSUMPTION IN THE EQUIPMENT SHALL BE LOW.IT
SHOULD BE LESS THAN 0.75A FOR FIELD UNIT AT 24VDC
• THERE SHOULD BE PROTECTION FOR OVER VOLTAGE,UNDER VOLTAGE
AND POLARITY REVERSAL.. HARDWARE STANDARDS • THE Ics USED IN THE EQUIPMENT SHALL BE OF INDUTRIAL GRADE AND SHALL BE PROCURED FROM RDSO APPROVED SOURCES • THE MATERIAL OF PCB SHALL BE COPPER CLAD AND THE SPACING BETWEEN TRACKS SHALL BE 0.5mm NOMINAL AND IN NO CASE IT SHALL BE LESS THAN0.3mm • BURNING TEST:ALL THE ELECTRONIC COMPONENTS USED IN THE EQUIPMENT SHALL BE SUBJECTED TO “BURN-IN” TEST FOR 48+/-1 Hr AT TEMPERATURE OF 65 DEGREES CENTIGRADE • AFTER MOUNTING OF COMPONENTS ,THE POPULATED PCB CARDS KEPT IN PROPER CHASIS IN ENERGISED CONDITION SHALL BE BURNT IN FOR 168Hrs at 60 DEGREES CENTIGRADE. • PERFORMANCE:THE AXLE COUNTER SERVICE LIFE SHALL NOT BE LESS THAN20 YEARS. INSPECTIONS AND TESTING • VISUAL INSPECTION • PERFORMANCE TEST • APPLIED HIGH VOLTAGE TEST • INSULATION RESISTANCE • CLIMATIC TESTS • SHOCK TESTS • 7KV STATIC DISCHARGE TEST • VIBRATION TEST • FAIL SAFE TESTS • THE TEST FOR SOFTWARE CHECK-SUM THANK YOU