12Gb SAS-3 SE Presentation

​Version 1.4.2

​AFF and FAS TME Team (ng-aff-fas-tme)


​June 2019

1 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Notice of NDA Content

The slides herein contain company confidential, proprietary information of NetApp and shall not be
disclosed outside NetApp without a binding nondisclosure agreement in place.

These documents are for viewing purposes only and shall not be distributed.

2 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Introducing the IOM12
12Gb shelf module

IOM12 1 2 3 4
 12Gb I/O SAS-3 Expander Modules
LNK LNK LNK LNK

||||||||||||||||||||||||||||||||||||||
S/N: 012345678901
 4x mini-SAS HD offers 48Gb bandwidth per port
 12Gb and 6G homogeneous stacks only
 Transitioning not allowed for external stack
 No IOM3 support with SAS-3 storage
 In-band Alternate Control Path (IBACP)
 Eliminates external Ethernet connections Out-of-Band ACP
(OOBACP)
 Supports Quad Path and Double-wide cabling options

4 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
2U Enclosures
Name scheme

 DS212C
 (2) rack units
 (12) drives
 (C) 12Gb SAS
 Aggregate 48Gb per SAS Domain

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

DS22 4C
 DS224C
 (2) rack units
900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB
 (24) drives
 (C) 12Gb SAS
 Aggregate 48Gb per SAS Domain

5 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
4U Enclosure
Name scheme

 DS460C
2 5 8 11
1 4 7 10

0 1 2 3 4 5 0 3 6 9 6 7 8 9 10 11
Front

 (4) rack units


2 5 8 11

1 4 7 10

0 1 2 3 4 5 0 3 6 9 6 7 8 9 10 11
Front

 (60) drives
2 5 8 11
1 4 7 10

0 3 6 9
0 1 2 3 4 5 6 7 8 9 10 11
Front

 (C) 12Gb SAS


2 5 8 11
1 4 7 10

0 3 6 9
0 1 2 3 4 5 6 7 8 9 10 11
Front

0 1 2 3 4 5
1

0
2 5
4

3
8 11
7 10

6
Front
9
6 7 8 9 10 11
 Aggregate 48Gb per SAS Domain

6 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Introducing the DS212C

4.0TB 4.0TB 4.0TB 4.0TB

DS21 2C
 Capacity class
4.0TB 4.0TB 4.0TB 4.0TB
 2U enclosure
4.0TB 4.0TB 4.0TB 4.0TB
 12x 3.5” 7.2k RPM drives
 Quotable NL-SAS/SATA drives: 2TB, 4TB, 8TB, & 10TB
IOM12

||||||||||||||||||||||||||||||||||||||
LNK
1 2

LNK LNK
3 4

LNK
A
IOM12

||||||||||||||||||||||||||||||||||||||
LNK
1 2

LNK LNK
3 4

LNK
 Quotable NL-SAS/SATA NSE drives: 10TB
 Support for legacy DS4243/DS4246 NL-SAS/SATA drives
S/N: 012345678901 S/N: 012345678901

 Refer to Hardware Universe for a complete list of supported drives


 12x 3.5” SSD
X2 2 X2 2

 960GB SSD available in Hybrid configuration only


 Same drive carrier as DS4243 and DS4246 shelves

 Common PSU
 Leverages same efficient 913W PSU as DS224C shelf and
FAS2600 series embedded systems

7 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Introducing the DS224C

 Performance class
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

DS22 4C

 2U enclosure
900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB
 24x 2.5” 10k RPM drives
 Quotable SAS drives: 900GB, 1.2TB, 1.8TB, 1.8TB NSE
IOM12

||||||||||||||||||||||||||||||||||||||
LNK
1 2

LNK LNK
3 4

LNK
A
IOM12

||||||||||||||||||||||||||||||||||||||
LNK
1 2

LNK LNK
3 4

LNK
 Support for legacy DS2246 drives

S/N: 012345678901 S/N: 012345678901

Refer to Hardware Universe for a complete list of supported drives

X2 2 X2 2
 24x 2.5” SSD
 Quotable SSD: 800GB NSE, 960GB, 3.8TB, 3.8TB NSE,
7.6TB, 15.3TB
 960GB, 3.8TB, 15.3TB available in Hybrid configuration only
 Same drive carrier as DS2246 shelf

 Common PSU
 Leverages same efficient 913W PSU as DS212C shelf and
FAS2600 series embedded systems

8 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Introducing the DS460C

 Density class
 4U enclosure
 60x 3.5” 7.2k RPM drives
 Quotable NL-SAS/SATA drives: 2TB, 4TB, 8TB, & 10TB
 Quotable NL-SAS/SATA NSE drives: 6TB & 10TB
 Orderable as empty, half-populated, or fully populated
 Minimum of 20x HDD requires for proper cooling
 Legacy drives from DS4243/DS4246 shelves not supported
X2 2
 Refer to Hardware Universe for a complete list of supported drives
IOM12
LNK
1 2

LNK LNK
3 4

LNK
 Maximum of 10x 3.5” SSD
 960GB available in Hybrid configuration only
||||||||||||||||||||||||||||||||||||||
S/N: 012345678901

IOM12 1 2 3 4

LNK LNK LNK LNK

 2325W ~220V PSU


||||||||||||||||||||||||||||||||||||||
S/N: 012345678901

X2 2

 Requires C19/C20 Power cable & compatible PDU


 Retrofits are not supported with C13/C19 power cords or
PDU

9 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Introducing the DS460C
Additional Features

 Requires ONTAP 9.1RC2 or later


 Shelf has 5 drawers with bays numbered 0-11 each, mapping 1-1 to drive elements 0 through 59
 Populate first row bays for each drawer for 20 drive minimum to ensure proper cooling
 Additional drives should be inserted in pairs for each drawer
 Populate from front to back

 Drive replacement is a non-disruptive operation


 Shelf drawer can be opened while system serving data to perform hot disk swap

 Stack depth
 Up to 4x DS460C shelves may be connected in same stack
 Attach only IOM12 based shelves (DS460C, DS224C, DS212C or IOM12 retrofit)
 IOM6 not supported in same stack

 Power
 Requires 220V power with C19/C20 based cords and cabinet PDU, C13/C19 not supported
10 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Introducing the DS460C
Drawer bay layout

2 5 8 11

1 4 7 10

0 3 6 9
Drawer front

11 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
DS460C Naming Convention
Drawer and bay numbering

cluster1::> storage disk show

                     Usable                  Disk    Container   Container  


Disk                   Size Shelf Drawer Bay Type    Type        Name      Owner
---------------- ---------- ----- ------ --- ------- ----------- --------- --------
1.16.0              546.9GB    16      1   0 SAS     spare       Pool0     cluster1-01
1.16.1              546.9GB    16      1   1 SAS     spare       Pool0     cluster1-01
1.16.2              546.9GB    16      1   2 SAS     spare       Pool0     cluster1-01
1.16.3              546.9GB    16      1   3 SAS     spare       Pool0     cluster1-01
1.16.4              546.9GB    16      1   4 SAS     spare       Pool0     cluster1-01
1.16.5              546.9GB    16      1   5 SAS     spare       Pool0     cluster1-01
1.16.6              546.9GB    16      1   6 SAS     spare       Pool0     cluster1-01
1.16.7              546.9GB    16      1   7 SAS     spare       Pool0     cluster1-01
1.16.8              546.9GB    16      1   8 SAS     spare       Pool0     cluster1-01
1.16.9              546.9GB    16      1   9 SAS     spare       Pool0     cluster1-01
1.16.10             546.9GB    16      1  10 SAS     spare       Pool0     cluster1-01
1.16.11             546.9GB    16      1  11 SAS     spare       Pool0     cluster1-01
1.16.12             546.9GB    16      2   0 SAS     spare       Pool0     cluster1-01
1.16.13             546.9GB    16      2   1 SAS     spare       Pool0     cluster1-01
1.16.14             546.9GB    16      2   2 SAS     spare       Pool0     cluster1-01
1.16.15             546.9GB    16      2   3 SAS     spare       Pool0     cluster1-01
1.16.16             546.9GB    16      2   4 SAS     spare       Pool0     cluster1-01
1.16.17             546.9GB    16      2   5 SAS     spare       Pool0     cluster1-01
1.16.18             546.9GB    16      2   6 SAS     spare       Pool0     cluster1-01
1.16.19             546.9GB    16      2   7 SAS     spare       Pool0     cluster1-01
1.16.20             546.9GB    16      2   8 SAS     spare       Pool0     cluster1-01
1.16.21             546.9GB    16      2   9 SAS     spare       Pool0     cluster1-01
.......
1.16.57             546.9GB    16      5   9 SAS     spare       Pool0     cluster1-01
1.16.58             546.9GB    16      5  10 SAS     spare       Pool0     cluster1-01
1.16.59             546.9GB    16      5  11 SAS     spare       Pool0     cluster1-01

12 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Hardware

13 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
IOM12
Rear view

mini-SAS HD mini-SAS HD
Warning LED

IOM12 1 2 3 4

LNK LNK LNK LNK

||||||||||||||||||||||||||||||||||||||
S/N: 012345678901

Blue LED beacon

14 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
DS212C Shelf
Front view

Bay 0

Power LED 4.0TB 4.0TB 4.0TB 4.0TB

DS21 2C

Warning LED
4.0TB 4.0TB 4.0TB 4.0TB

Blue LED beacon

4.0TB 4.0TB 4.0TB 4.0TB

Shelf ID Bay 11

15 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
DS224C Shelf
Front view

Bay 0

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Power LED
DS22 4C

Warning LED

Blue LED beacon


900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB

900GB
Shelf ID Bay 23

16 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
DS212C / DS224C Shelf
Rear view

IOM12 1 2 3 4 IOM12 1 2 3 4
A
Module A LNK LNK LNK LNK
Module B LNK LNK LNK LNK

|||||||||||||||||||||||||||||||||||||| ||||||||||||||||||||||||||||||||||||||
S/N: 012345678901 S/N: 012345678901

X2 2 X2 2

PSU PSU

17 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
DS460C Shelf
Front view

Drawer 1

2 5 8 11

1 4 7 10

0 3 6 9
0 1 2 3 4 5 6 7 8 9 10 11
Front

2 5 8 11

1 4 7 10

0 1 2 3 4 5 0 3 6 9 6 7 8 9 10 11
Front

2 5 8 11

1 4 7 10

0 1 2 3 4 5 0 3 6 9 6 7 8 9 10 11
Shelf ID Front

Power LED 1
2 5

4
8 11

7 10

0 1 2 3 4 5 0 3 6 9 6 7 8 9 10 11
Front

Warning LED
2 5 8 11

1 4 7 10

Blue LED beacon 0 1 2 3 4 5 0 3 6 9 6 7 8 9 10 11


Front

OPS Panel Drawer 5


Display Button

18 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
DS460C Shelf
Rear view
Fan Module PSU Fan Module

X2 2

IOM12 1 2 3 4

Module A LNK LNK LNK LNK

||||||||||||||||||||||||||||||||||||||
S/N: 012345678901

IOM12 1 2 3 4
Module B
LNK LNK LNK LNK

||||||||||||||||||||||||||||||||||||||
S/N: 012345678901

X2 2

PSU

19 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Controller-to-Shelf Conversions

Conversion Stack Speed Part Number


FAS2240-2, FAS2552  DS2246 6Gb X896A
DS2246  DS224C1 12Gb X899A
FAS2240-4, FAS2554  DS4246 6Gb X897A
DS4246  DS424C1 12Gb X898A
FAS2620, FAS2720  DS212C 12Gb X898A
FAS2650, FAS2750  DS224C 12Gb X899A

1. Used for creating 12Gb homogeneous stack with existing storage. Speed of storage stack will be 12Gb, but shelf backplane is locked at 6Gb speed.
20 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3 Upgrade Paths
Shelf Conversion Kits

 NetApp Part Number: X898A


 Conversion Kit for FAS2720, FAS2620, FAS2554, FAS2240-4
 Can also be used for DS4246 shelf upgrades
 2x IOM12 shelf modules
 2x .5 meter shelf-to-shelf cables (mini-SAS HD)
 2x shelf end caps for DS212C

 NetApp Part Number: X899A


 Conversion Kit for FAS2750, FAS2650, FAS2552, FAS2240-2
 Can also be used for DS2246 shelf upgrades
 2x IOM12 shelf modules
 2x .5 meter shelf-to-shelf cables (mini-SAS HD)
 2x shelf end caps for DS224C
 Not supported for usage with AFF A200

21 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
SAS-3
Technical details

22 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3 Storage
Requirements

 ONTAP 9.0 or later


 ONTAP 8.x not supported

 Shelves
 DS224C: 12Gb, 24x 2.5” SFF drive enclosure
 DS212C: 12Gb, 12x 3.5” LFF drive enclosure
 DS460C1: 12Gb, 60x 3.5” LFF drive enclosure

 I/O module expanders


 IOM12: 4-port, mini-SAS HD

 HBA adapter support


 X2069-R6: 4-port, QSFP, PCIe HBA
 X2071-R62: 4-port, mini-SAS HD, PCIe HBA
 X92071A: 4-port, mini-SAS HD, PCIe I/O module
 ATTO 7500N: Embedded HBA
 FAS8200, FAS2600: Embedded HBA
1. Supported with ONTAP 9.1RC2 or later.
2. Supported with ONTAP 9.2 or later.
23 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3 Storage
Stack support and limitations

 SAS-3 stack support


 Standard mini-SAS HD cables
 Transitional mini-SAS HD-to-QSFP cables
 Optical cabling (requires ONTAP 9.1 or higher)
 Homogeneous Add-ons
 12Gb and 6Gb only; IOM3 is not supported
 Stack cannot be a mix of SAS-3 and SAS-2
 Entry level embedded platforms support both SAS-2 and SAS-3, but the external stack cannot be mixed
 Quad-path and Double-wide cabling support available
 Support for 7500N Fabric Bridge (MCC) only, 6500N is not supported with SAS-3 storage

 Upgrade path from SAS-1 and SAS-2


 6Gb DS2246 + IOM12  12Gb SAS upgrade; backplane remains 6Gb
 6Gb DS4246 + IOM12  12Gb SAS upgrade; backplane remains 6Gb
 3Gb DS4243 + IOM12  12Gb SAS upgrade; backplane performance upgrades to 6Gb

Refer to slide 31 for additional details


24 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3 Storage
Differences between X2069A and X2071A

 SAS adapter X2071A is very similar to X2069A X2071A X2069A

 Based on the same PMC Sierra (now Microsemi) Ports 4 4


PM8072 chip
Connector Mini-SAS HD QSFP
 Firmware and ONTAP drivers are the same as the
existing X2069A Speed 12Gb/6Gb 12Gb/6Gb

ASIC Microsemi PM8072 Microsemi PM8072


 Only difference is the connections
 X2069A uses QSFP wide SAS connections ONTAP Support ONTAP 9.1P10+ ONTAP 8.2.3+

 X2071A uses mini-SAS connections AFF A700s, AFF A700s,


Platform Support AFF A300, FAS8200 AFF A300, FAS8200
AFF/FAS8000 Series AFF/FAS8000 Series
 X2071A supported at 6Gb and 12Gb speeds
 Use mini-SAS to QSFP cables to connect to 6Gb IOM6
shelf modules

Refer to Hardware Universe for additional platform and ONTAP support details.
25 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3 Storage
Legacy Shelf Support with X2071A

 All 6Gb shelves are supported for use with X2071A


 DS2246
 DS4246
 DS4486

 DS4243 shelves are also supported for use with X2071A


 IOM3 must be upgraded to IOM6

 12Gb and 6Gb shelves must be on separate homogenous stacks


 Optional to change IOM6 with IOM12 to mix in same stack

 Order mini-SAS HD to QSFP cables to connect X2071A to 6Gb shelves

26 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
SAS-3 12Gb Storage
Stack enhancements

 Software Enhancements
 In-band ACP (IBACP)
 External Ethernet cabling is not required
 Updated SAS-3 aware Config Advisor tool for deployments
 NSS download from Tool Chest
 New and improved Node Connectivity Health Monitor (NCHM)
 Blue Location LED on DS224C and DS212C chassis

27 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
SAS-3 12Gb Storage
Innovations

 New SSD Technology


 MSW (Multi-Stream Write) capabilities
 Overprovisioning requirements decrease by up to 20% (MSW not required for Lower Overprovision)
 Enable support for lower capacity drives

 SSD High Capacity First


 First to market with 15.3TB SSD
 Leverages Advanced Drive Partitioning (ADP) with Root-Data-Data (R-D2) SSD sharing
 Provides 17% greater efficiency compared to Root-Data (RD) partitioning

 HDD NL-SAS/SATA Offering


 Support for 10TB, 8TB and 4TB LFF 7.2K SAS HDD
 10TB > HDD requires RAID-TEC and ONTAP 9 or later

28 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3 IOM12 Expander Module

 IOM12 Upgrade path for 3 & 6 Gb shelves IOM12 1 2 3 4

LNK LNK LNK LNK

 DS4246 + IOM12 ||||||||||||||||||||||||||||||||||||||


S/N: 012345678901

 DS4243 + IOM12
 DS2246 + IOM12

 In-band Alternate Control Path (IBACP)


only LNK LNK
IOM6

 Eliminates external ACP Ethernet connections


Out-of-Band ACP (OOBACP) IOM6

 Note: IOM6 supports IBACP but requires


minimum shelf firmware 0209 or later

29 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3 at a Glance
Storage enclosures

DS224C DS212C DS460C


Segment Performance Capacity Density

Rack Space 2U 2U 4U

Drive Slots 24 12 60

Drive Size SFF - 2.5” LFF- 3.5” LFF-3.5”

SSD 7.2K NL-SAS 7.2K NL-SAS


Drive Types
10K SAS SSD (Hybrid Only) SSD (Hybrid Only)

SAS Interface Speed 12Gb 12Gb 12Gb

Backplane Speed 12Gb 12Gb 12Gb


ONTAP® support 9.0+ 9.0+ 9.1RC2+

30 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3 Upgrade Paths
Storage enclosures

DS2246 + IOM12 DS4246 + IOM12 DS4243 + IOM12


Segment Performance Capacity Capacity

Rack Space 2U 4U 4U

Drive Slots 24 24 24

Drive Size SFF - 2.5” LFF- 3.5” LFF-3.5”

SSD 7.2K NL-SAS 7.2K NL-SAS


Drive Types
10K SAS SSD (Hybrid Only) SSD (Hybrid Only)

SAS Interface Speed 12Gb 12Gb 12Gb

Backplane Speed 6Gb 6Gb 6Gb


ONTAP® support 9.0+ 9.0+ 9.0+

Refer to Hardware Universe for supported drive configurations.


31 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Drive Ownership

32 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Drive Ownership
An overview

 There are five drive assignment policies that determine physical drive ownership in a HA pair
 Bay assignment: entry FAS systems
 Used by entry AFF systems running ONTAP 9.3 or earlier
 Stack assignment: mid or high-range FAS systems
 Shelf assignment: mid or high-range FAS systems
 Split-shelf assignment: AFF systems
 Support added for entry AFF systems with ONTAP 9.4 or later
 Drawer assignment: FAS systems

 The policy used will vary between AFF and FAS platforms configurations

33 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Drive Ownership
Bay Assignment Bay 0

 Used by entry FAS (2620 | 2720) systems


 Drives in even numbered bays are assigned to Node 1
 Drives in odd numbered bays are assigned to Node 2

Bay 0 Bay 11

 Used by entry FAS (2650 | 2750) systems


 Drives in even numbered bays are assigned to Node 1
 Drives in odd numbered bays are assigned to Node 2

Bay 23

34 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Drive Ownership
Stack Assignment

 Used when multiple stacks are present


 All drives per stack are assigned to one node
 Shelf type is irrelevant

35 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Drive Ownership
Shelf Assignment

 Used when a single stack is present


 All drives in a shelf are assigned to one node
 Shelf type is irrelevant

36 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Drive Ownership
Split-shelf Assignment Bay 0

 Support added for entry AFF systems


 Support added for AFF A220 in ONTAP 9.4
 Support added for AFF A200 in ONTAP 9.5

 AFF A220 / A200


Bay 12
 Drives in bays 0-11 are assigned to Node 1
 Drives in bays 12-23 are assigned to Node 2

37 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Drive Ownership
Split-shelf Assignment

 Used in mid and high-range AFF systems


 Requires DS2246 or DS224C shelves
 Drives in bays 0-11 are assigned to Node 1
 Drives in bays 12-23 are assigned to Node 2

38 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Drive Ownership
Drawer Assignment

 Used when a single DS460 shelf is present

Drawer Node A Node B


1 00-11 -
2 - 12-23
3 (unassigned)
4 (unassigned)
5 (unassigned)

39 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
SAS-3 Cabling

40 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3
Cables

HBA/expander cable connectors – Support 12Gb connectivity:


 Native SAS-3 - both endpoints Mini-SAS HD
 Transitional Cable SAS-3 – (1) endpoint Mini-SAS HD & (1) endpoint QSFP

41 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3 Supported Cables
ONTAP 9.0 and later

Part No Mfg Part No Length End 1 End 2 Supported Speed(s)


X66030A 112-00435 0.5m mini-SAS HD mini-SAS HD 12/6 Gb

X66020A 112-00429 1m mini-SAS HD QSFP 12/6 Gb

X66031A 112-00436 1m mini-SAS HD mini-SAS HD 12/6 Gb

X66021A 112-00430 2m mini-SAS HD QSFP 12/6 Gb

X66032A 112-00437 2m mini-SAS HD mini-SAS HD 12/6 Gb

X66033A 112-00438 3m mini-SAS HD mini-SAS HD 12/6 Gb

X66022A 112-00431 5m mini-SAS HD QSFP 12/6 Gb

X66034A 112-00439 5m mini-SAS HD mini-SAS HD 12/6 Gb

Refer to Hardware Universe for additional cabling details.


42 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3 Supported Cables
ONTAP 9.1 and later

Part No Mfg Part No Length End 1 End 2 Supported Speed(s)


X66040A 112-00449 1m mini-SAS HD mini-SAS HD 12/6 Gb

X66041A 112-00450 2m mini-SAS HD mini-SAS HD 12/6 Gb

X66042A 112-00451 3m mini-SAS HD mini-SAS HD 12/6 Gb

X66043A 112-00452 5m mini-SAS HD mini-SAS HD 12/6 Gb

X66044A 112-00453 15m mini-SAS HD mini-SAS HD 12/6 Gb

X66045A 112-00454 30m mini-SAS HD mini-SAS HD 12/6 Gb

X66046A 112-00455 50m mini-SAS HD mini-SAS HD 12/6 Gb

X660471 112-00456 5m mini-SAS HD LC 12/6 Gb

X66048A1 112-00457 30m mini-SAS HD LC 12/6 Gb

1. Refer to the SAS-3 Cabling Guide for optical cabling rules. Refer to Hardware Universe for additional cabling details.
43 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Expander & SAS Initiator Support
ONTAP 9.1 and later

SAS-2 SAS-3 SAS-2 Shelf SAS-3 Shelf HBA SAS Initiator


Support Support IOM6 Expander IOM12 Expander

FAS2700, AFF A220 ✔ ✔ QSFP: 6Gb Mini-SAS HD: 12Gb Onboard: mini-SAS HD, 12Gb

FAS2600, AFF A200 ✔ ✔ QSFP: 6Gb Mini-SAS HD: 12Gb Onboard: mini-SAS HD, 12Gb

Onboard: mini-SAS HD, 12Gb


FAS8200, AFF A300 ✔ ✔ QSFP: 6Gb Mini-SAS HD: 12Gb External: X2069-R6, 12Gb, QSFP, PCIe
External: X2071-R6, 12Gb, mini-SAS HD, PCIe

FAS9000, AFF A700 ✔ ✔ QSFP: 6Gb Mini-SAS HD: 12Gb External: X92071A, mini-SAS HD, 12Gb, PCIe

✔ ✔ QSFP: 6Gb Mini-SAS HD: 12Gb External: X2069-R6, 12Gb, QSFP, PCIe
AFF A700s External: X2071-R6, 12Gb, mini-SAS HD, PCIe

 Stack operations can be run at 12Gb if HBA is 12Gb and are SAS-3 shelves
 DS212C, DS224C, DS460C, or DS4243/DS4246/DS2246 with IOM12, otherwise speed will negotiate to 6Gb

 Transitional QSFP-to-Mini-SAS HD cabling required for mixed interface connectivity


 Speed will negotiate at lowest common speed
44 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Expander & SAS Initiator Support
ONTAP 9.1 and later

SAS-2 SAS-3 SAS-2 Shelf SAS-3 Shelf HBA SAS Initiator


Support Support IOM6 Expander IOM12 Expander

FAS22xx, FAS25xx ✔ ✔ QSFP: 6Gb Mini-SAS HD: 12Gb Onboard: QSFP, 6Gb

✔ ✔ QSFP: 6Gb Mini-SAS HD: 12Gb Onboard: QSFP, 6Gb


FAS32xx External: X2069-R6, 12Gb, QSFP, PCIe

✔ ✔ QSFP: 6Gb Mini-SAS HD: 12Gb External: X2067-R6, 6Gb, QSFP, PCIe
FAS62xx External: X2069-R6, 12Gb, QSFP, PCIe

✔ ✔ QSFP: 6Gb Mini-SAS HD: 12Gb Onboard: QSFP, 6Gb


FAS80xx, AFF80xx External: X2069-R6, 12Gb, QSFP, PCIe

 Stack operations can be run at 12Gb if HBA is 12Gb and are SAS-3 shelves
 DS212C, DS224C, DS460C, or DS4243/DS4246/DS2246 with IOM12, otherwise speed will negotiate to 6Gb

 Transitional QSFP-to-Mini-SAS HD cabling required for mixed interface connectivity


 Speed will negotiate at lowest common speed

45 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
SAS-3 Stack Cabling
Multipath and Quad-Path Configurations

46 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
MPHA Cabling
FAS2600 with external shelves

 FAS2600 HA pair
 Cabling is the same for a FAS2700 controller

 3x DS212C or DS224C shelves


 Single stack configuration

 12Gb SAS Cabling

47 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
MPHA Cabling
FAS2520 with external shelves

 FAS2520 HA pair
 3x DS212C or DS224C shelves
 Single stack configuration

 12Gb SAS Cabling


 Transitional cables between controller and
shelves 1 and 3
 Native 12Gb SAS cabling between shelves

48 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
MPHA Cabling
FAS8200 with external shelves

 FAS8200 HA pair
 2 connections per controller to storage stack

 3x DS212C or DS224C shelves


 Single stack configuration

 12Gb SAS Cabling

49 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
QPHA Cabling
FAS8200 with external shelves

 FAS8200 HA pair
 4 connections per controller to storage stack

 3x DS212C or DS224C shelves


 Single stack configuration

 12Gb SAS Cabling

50 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
SAS-3 Mixing Rules
Mixing rules and best practices

51 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3 Requirements
Overview

 ONTAP 9.x is required for 12Gb SAS-3 attachment


 ONTAP 8.x is not supported

 Speed transitions are not permitted between shelves in a 12Gb stack


 12Gb or 6Gb homogenous stacks must be cabled into separate stacks

 12Gb entry platforms support both 12Gb and 6Gb speeds


 Shelf speeds in the external stack must be homogenous

52 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3 Recommendations
Best practices

 Provision SAS-3 native homogeneous configurations


 Ideal to provision native 12Gb SAS-3 shelves for all add-on storage within the HA pair

 For best performance, provision SAS-3 storage in homogenous stacks within the HA pair
 Separate 12Gb and 6Gb stacks are permitted within an HA pair, but it is best not to mix speeds within the stack
 12Gb entry platforms support both 12Gb and 6Gb
 Shelf speeds in the external stack must be homogenous

 Quad Path cabling recommended for large block, 64k or larger, sequential read workloads
 Multipath HA sufficient for other workloads

 Upgrade legacy 3Gb and 6Gb shelves with IOM12 for 12Gb intrastack connectivity
 Upgrading to IOM12 modules enables interoperability with SAS-3 shelves at 12Gb
 Storage stack will operate at 12Gb, but shelf backplanes will limit individual shelf performance to 6Gb
 12Gb drives are not required

53 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3 Stack Mixing Rules
Maximum stack depth and drive types

 HDD shelves support a maximum stack depth of (10) shelves


 SSD shelves support a maximum stack depth of (4) shelves
 FAS2600, FAS2700, AFF A200, & AFF A220 support a maximum of (6) SSD-only shelves

 Up to 6 shelves for hybrid or mixed storage (SSD+HDD), are supported in same stack
 Drives of the same type (e.g. NL-SAS) but different capacity can be mixed in the same shelf
 Not recommended to provision in same RAID group

 Drives of different types (e.g. NL-SAS and SAS 10k) can be mixed in the same stack
 Cannot be mixed within the same RAID group or aggregate

54 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
6Gb SAS-3 Stack Mixing Rules
Maximum stack depth and drive types

 IOM12 shelf support


 New controllers: FAS2700, FAS2600, FAS8200, FAS9000, AFF A200, AFF A300, AFF A700, and AFF A700s
 Support mix of IOM12 shelves in the same stack in ONTAP 9.1 or later
 Legacy controllers: FAS2200, FAS2500, FAS3200, FAS6200, FAS8000, and AFF8000
 Support mix of IOM12 shelves in the same stack running ONTAP 9.0 or later

 IOM3 and IOM6 shelf support


 New controllers support mix of IOM6 shelves in the same stack in ONTAP 9.1 or later
 IOM3 are not supported
 Legacy controllers support mix of IOM12 based shelves in the same stack running ONTAP 9.0 or later
 Stacks with 3Gb and 6Gb shelves will negotiate to the lowest common speed

55 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Alternate Control Path
Overview

 12Gb shelves support in-band ACP (IBACP) with 12Gb SAS-3 cabling
 IBACP is also supported on legacy controllers (9.0+) and new controllers in (9.1+)

 6Gb shelves support both IBACP & out-of-band ACP (OOBACP)


 Requires separate Ethernet cabling
 OOBACP offered for legacy in 9.1, 9.0 and earlier
 IBACP requires shelf firmware 2.09 or later; See KB InBand ACP setup
 Legacy systems with existing IOM6, require OOBACP to be setup before updating shelf firmware and enabling IBACP
 New controllers must have the shelf firmware for IOM6 updated to 2.09 prior to attaching storage

 3Gb shelves support only OOBACP


 New controllers do not support IOM3 as a dedicated ACP port is not present
 Supported with legacy systems in 9.1 and earlier

56 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Shelf Stack Drive Limits - FAS
ONTAP 9.x with SAS-3

System Model HDD only stack SSD only stack SSD+HDD stack
maximum drives maximum drives maximum drives

All FAS/V-Series systems, except those listed below 240 96 96

FAS2220 and FAS2520 84 60 60


FAS26201 ,FAS27201 1442 1442 1442

FAS2240-2, FAS2240-4, FAS2552, FAS2554, FAS8020 144 96 144

FAS2650, FAS2750 144 144 144

1. Must not exceed stack depth of 10 including internal shelf


2. Maximum listed when DS224C or DS2246 are attached

57 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Shelf Stack Drive Limits - AFF
ONTAP 9.x with SAS-3

System Model SSD only stack


maximum drives
All AFF, except listed below 96

AFF A200, AFF A220 144

Best Practices for SSDs:


 Provision additional stacks before increasing stack depth whenever possible to minimize latency
Example: In an HA pair with two 2 SSD-only shelves, Option 1 is recommended
 Option 1: 2 separate stacks of 1 shelf per node (Best)
 Option 2: 1 larger stack of 2 shelves

58 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb Shelf Upgrades
Mixing rules

 Upgrade option of DS4243, DS2246, DS4246's modules to IOM12


 Enables 12Gb transport speed for the data between shelves
 Shelf backplane will continue to run at 6Gb

 IOM12 upgrade procedure is a disruptive operation


 System and storage must be powered down to complete swap operation of IOM3/IOM6 to IOM12

 Upgrade Ordering Process


 Order one conversation kit per shelf
 Refer to slide 21 for details

 Drive and Cabling Support for IOM12 upgrade


 All drives installed in DS4243, DS4246 and DS2246 will be supported with IOM12 modules including 15K SAS
 5-year window from first purchase observed for spare replacement entitlements
 All legacy platforms running 9.0 or 9.1, or new 12G controllers on 9.1, are supported
 ONTAP 8.x is not supported
 Cabling rules follow same guidelines as native SAS-3 - DS212C & DS224C
59 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
6Gb Shelf Upgrades
Mixing rules

 Upgrade option of DS4243 modules to IOM6


 Enables 6Gb transport speed for the data between shelves
 Shelf backplane will continue to run at 6Gb

 IOM6 upgrade procedure is a disruptive operation


 System and storage must be powered down to complete swap operation of IOM3 to IOM6

 Upgrade Ordering Process


 Order one conversation kit per shelf
 Refer to slide 21 for details

 Drive and Cabling Support for IOM6 upgrade


 All drives installed in DS4243 shelves will be supported with IOM6 modules including 15K SAS
 5-year window from first purchase observed for spare replacement entitlements
 Cabling rules follow same guidelines as native SAS-1 (DS4243)
 Multiple stack transitions between IOM6 and IOM3 are permitted with ONTAP 9.2P1 or later

60 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
12Gb SAS-3 Platform Support
ONTAP 9.1 and later

Shelf Type FAS2220 FAS2240-2 FAS2240-4 FAS3200


IOM3 IOM6 IOM12 FAS8000 AFF8000
(External) FAS2520 FAS2552 FAS2554 FAS6200
DS224C no no yes ✔ ✔ ✔ ✔ ✔ ✔

DS212C no no yes ✔ ✔ ✔ ✔ ✔

DS460C1 no no yes ✔ ✔

DS2246 no yes yes* ✔ ✔ ✔ ✔ ✔ ✔

DS4246 no yes yes* ✔ ✔ ✔ ✔ ✔

DS4243 no yes* yes* ✔ ✔ ✔ ✔ ✔

 All drives supported in DS4243, DS2246 & DS4246, will be supported on 9.x in upgraded shelf (IOM6, IOM12) configurations
 Includes 15K SAS drives
 Must be within 5 year window of original sale to qualify for service entitlement drive replacements
 DS460C shelves require ONTAP 9.1RC2 or later
1. Refer to Hardware Universe for additional platform support information.
61 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Cooling Architecture

 PSU blowers provide cooling for power supplies, shelf modules, and drives
 Air flows in through disks, then splits between shelf modules and power supplies
 Fan speed regulated by Storage Enclosure Services (SES)
 SES forces higher or lower fan speeds to provide adequate cooling
 ONTAP monitors temperature sensors, power supplies, and fan speeds via SES

 One failed fan allowed per storage enclosure


 Storage enclosure will run indefinitely with one failed PSU
 Blowers continue to operate even if PSU fails
 2-minute shutdown rule applies during PSU removal and replacement
 ONTAP® initiates the shutdown

62 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Power Architecture

 Number of power supplies (PSU) is dependent on storage enclosure


 DS212C: Two PSUs present
 Two blowers per PSU
 DS224C: Two PSUs present
 Two blowers per PSU
 DS460C: Two PSUs present
 Blowers are present in a separate field-replaceable unit (FRU)
 4 blowers per FRU

 One failed power supply allowed per storage enclosure


 Shelf will run indefinitely with single failed PSU

 Blowers are powered by the backplane and will continue to run if PSU fails
 Leave failed PSU in place until replacement arrives
 2-minute shutdown rule applies during PSU removal and replacement

63 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Environmental Details
Power, thermals, weight, dimensions

 For the latest and most complete environmental information, refer to:

Hardware Universe
(https://hwu.netapp.com)

64 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Dimensions, Weight, and Acoustics
DS212C

Metric Imperial
Rack Units 2U
Chassis Height 8.7 cm 3.43 in
Width 48.0 cm 18.9 in
Width (without mounting flanges) 44.7 cm 17.6 in
Chassis depth 53.4 cm 21.02 in
Chassis depth (without cable
50.5 cm 19.88 in
management)
Weight (empty) 16.0 kg 35.27 lbs
Sound power (LwAd) per ISO 9296 6.3 bels

65 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Dimensions, Weight, and Acoustics
DS224C

Metric Imperial
Rack Units 2U
Chassis Height 8.5 cm 3.35 in
Width 48.0 cm 18.9 in
Width (without mounting flanges) 44.7 cm 17.6 in
Chassis depth 61.3 cm 20.2 in
Chassis depth (without cable
51.3 cm 19.02 in
management)
Weight (empty) 16.0 kg 35.27 lbs
Sound power (LwAd) per ISO 9296 6.9 bels

66 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Dimensions, Weight, and Acoustics
DS460C

Metric Imperial
Rack Units 4U
Chassis Height 17.6 cm 6.93 in
Width 48.6 cm 19.13 in
Width (without mounting flanges) 44.9 cm 17.68 in
Chassis depth 92.2 cm 36.3 in
Chassis depth (without cable
85.9 cm 33.82 in
management)
Weight 61.0 kg 134.48 lbs
Sound power (LwAd) per ISO 9296 5.0 bels

67 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Certification Information
EMI certifications
Type  Country  Test Standards  Notes
 Safety  U.S.  60950-1  
   CAN  CAN/CSA-22-2 NO.60950-1  Equivalent to UL 60950
   EU  EN 60950-1  
 Emission  U.S.  FCC part 15, Subpart B, Class A  FCC Class A minimum
   CAN  ICES-003   
   EU  EN 55022, Class A  Emission of ITE
     CISPR22  
     EN 61000-3-2  AC Line Harmonic
     EN 61000-3-3  AC Line Flicker
 Immunity  U.S.  N/A  
   CAN  N/A  
   EU  EN 55024  Immunity of ITE
     EN 61000-4-2  ESD
     EN 61000-4-3  RF
     EN 61000-4-4  Fast Transient
     EN 61000-4-5  Surge
     EN 61000-4-6  Conducted
     EN 61000-4-11  Line Dip/ Interrupt
Environmental ASHRAE A4 Compliant

68 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---
Thank You.

69 © 2019 NetApp, Inc. All rights reserved. --- NETAPP CONFIDENTIAL ---