• There is no specific FAR with means of access of 3.5 m to
7m width • Ground coverage up to 45% • Minimum open spaces for land area above 500sqm and building height above 10 m up to 15.5 m : 3.5 m in front , 4.0 m in both sides, 5.0 m in rear side. • For land area above 500 sqm , width of staircases is min 1.8m , no of staircases should be 2 • at least one lift shall be provided in every building more than 12.5 m. in height • in the case of buildings more than 20 m. in height, and 1000 sq. m. of floor area for each floor at least two lifts shall be provided. • A parapet and guardrails shall be provided on the edge of any roof terrace or balcony, and it shall not be more than 1.5 m. in height on average. • Exits shall be so located that the travel distance shall not exceed - (a) 22.5 m., in the case of a residential building or an educational building or an institutional building