You are on page 1of 65

IP-20N Overview

Ceragon Training Services

Proprietary and Confidential


August 2016
Agenda
• IP-20N Product Highlights

• Network topology with IP-20N

• IP-20N Overview
• 1U and 2U chassis
• TCC – Traffic Control Card
• RMC – Radio Modem Cards
• ELIC – Ethernet Line Interface Cards & TDM Line cards
• IVM – Inventory Module
• PDC – Power Distribution Card & Fan Module and Air Filter
• RFU – Radio Frequency Units

• IP-20N Block Diagram

Proprietary and Confidential 2


FibeAir IP-20 Platform
A SINGLE platform serving ALL your wireless backhaul needs

Small Cells Access Access 1st Aggregation 1st Aggregation


2nd Aggregation 2nd Aggregation
Backbone Backbone

FibeAir IP-20V IP-20E IP-20S IP-20G IP-20C IP-20GX IP-20N IP-20LH


2500SC JET All-Outdoor All-Outdoor All-Outdoor Split Mount Multicore Extendable Modular Long Haul

Sub 6GHz V-Band E-Band 6 - 42GHz 4 – 11GHz

Proprietary and Confidential 3


FibeAir IP-20 Platform
A SINGLE platform serving ALL your wireless backhaul needs

Shorthaul to Longhaul Ultra High Capacity All Site Configurations


Backhaul & Fronthaul All Frequencies

1st Aggregation 1st Aggregation2 Aggregation Backbone


nd
Small Cells Access Access 2nd Aggregation Backbone

Proprietary and Confidential 4


FibeAir IP-20 Product Family

IP-20E

IP-20N 1RU & 2RU


IP-20S

IP-20
IP-20C

IP-20GX

Platform
IP-20G

IP-20A= IP20N for US & NA market

IP-20LH
Proprietary and Confidential 5
Product selection - band Hybrid All-IP

Modular Multi-core
Hybrid All-IP
Sub-6GHz V-Band E-Band 4-42 GHz

FibeAir FibeAir FibeAir FibeAir FibeAir FibeAir FibeAir FibeAir


2000/2500 IP-20V IP-20E IP-20S IP-20G IP-20GX IP-20N IP-20LH
IP-20LH
IP-20C

Proprietary and Confidential


Product selection – technology/configuration Hybrid All-IP

Modular Multi-core
Microwave Hybrid All-IP

All-IP TDM / Hybrid

All-Indoor/Split
All Outdoor
mount

FibeAir FibeAir FibeAir FibeAir


IP-20E FibeAir FibeAir
IP-20S IP-20G IP-20GX
IP-20C IP-20N

Proprietary and Confidential


FibeAir IP-20N

Proprietary and Confidential


IP-20N – High-availability aggregation node for all-
packet and hybrid networks
Hybrid
• High capacity modular aggregation node TDM-IP
Split-mount /
• Up to 10 radio carriers All indoor
• Supporting TDM and IP Aggregation
• 16xE1/T1, 4xGE, ch-STM-1/OC-3 interfaces
10 Carriers
• 10GBps switching capacity
4-42 GHz
• Internal full redundancy
• 1RU, 2RU options 5,7-56,60
MHz

Proprietary and Confidential 9


Unified architecture with common
FibeAir IP-20N Highlights cards
• Traffic/control card (TCC)
• Radio modem/interface cards (RMC/RIC)
o XPIC or non-XPIC
o 2048 QAM
1RU chassis, Up to 5 RFUs
• Same platform for SH & LH
• Standard power radios
• High power radio => 30dBm
• All-indoor / split-mount
• Line cards (LIC)
• Ethernet: LIC-X-E4-Elec./Opt (4x 1GE / 1x
10GE)
• TDM:
2RU chassis, Up to 10 RFUs
• LIC-T16 (16x E1/T1)
Full redundancy option (No SPoF)
• LIC-T155(1x ch-STM-1/
• LIC-STM1/OC3-RST(1xSTM-1)
Purpose-built for aggregation nodal sites ; Ultra-high flexibility/modularity
Optimized foot-print, density, scalability & availability

Proprietary and Confidential 10


FibeAir IP-20N Highlights
Optimized nodal solution
• Multi-Carrier ABC:
• 1 x Up to 8+0 MC-ABC (Up to 1Gbps)
• 1+1/2+2 MC-ABC/HSB (Up to 1Gbps)
• Mixed Nx1+0/1+1 & 1x ABC (4+0)
• 4 X 2+0 Multi-Carrier ABC (2RU chassis)
• 2 X 2+0 Multi Carrier ABC (1RU chassis)
• 2 X 4+0 Multi-Carrier ABC (2RU chassis)

• High Availability node, No Single Point Of Failure in 2RU

• Support for multi-operator scenarios

• High capacity, scalability and spectral efficiency, High precision, flexible packet Synchronization solution

• Best-in-class TDM migration using PWE3 (Circuit Emulation)

• Support for Ceragon’ s current and future Radio Frequency Units

• Built for supporting resilient and adaptive multi-carrier links scaling to GE capacity

• Future-proof with maximal investment protection

• Advanced Security features: payload encryption AES-256

Proprietary and Confidential 11


FibeAir IP-20N – Carrier Ethernet Transport
Main features
• Flexible transport

• Flexible service classification

• Full E-Line, E-LAN support

• Complete SOAM(Service Operations Administration and Maintenance) and SLA assurance mechanisms

• MSTP

• Enhanced <50msec network level resiliency (G.8032)

• Advanced L2-4 security policy (Access Control List) engine

• ACM QPSK – 2048 QAM

• LIC-X-E4-Electrical / Optical (4x 1GE )

Future proof architecture for supporting


backhaul evolution to emerging services
Proprietary and Confidential 12
Network Topologies examples

Proprietary and Confidential 13


FibeAir IP-20 Platform
Deliver Multi-Gbps Anywhere That It’s Needed
Microwave
60GHz
MSC/RNC/S-GW

Macro E-Band
Fiber Aggregation
Network PtMP Sub 6GHz
Macrocell Macro+

Backhaul Macro
Aggregation
Versatile deployment
Node
scenarios
Carrier Ethernet
MPLS-TP
IP/MPLS
and DU
E-B CPRI
r Super Size
Fo Aggregation
RU Macro Site Aggregation Node
Node
E-Band

CPR
I Macro-Site
C-RAN p re ssed nds
a Aggregation
Com icense b 60GHz
Fronthaul over
l
High capacity &
Small
High capacity, low latency DU interoperability
RU Cells
Super Size
Macro Site
PtMP
Sub 6GHz

Small
DU
Cells
RU

Compressed CPRI
over license bands

Proprietary and Confidential 14


Network Topology Example (Tree)
FibeAir IP-20C
Compact All-Outdoor
Multi-Core

Fiber
IP-20G Aggregation Core
Network
Network
IP-20C

IP-20C IP-20N 1RU IP-20N 2RU


Tail/Edge Node
IP-20C
FibeAir IP-20N
1RU / 2RU Modular Chassis

IP-20S IP-20S

IP-20G
FibeAir IP-20S
Compact All-Outdoor IP-20G
Multi-Core IP-20G IP-20G
Aggregation Node
Up to 5/10 RFUs
FibeAir IP-20G Full redundancy
1RU Fixed Design, Cascadable

IP-20S IP-20G

Tail Node Tail/Edge Node 15


Proprietary and Confidential
FibeAir IP-20N
1 RU Modular Chassis

Network Topology Example (Ring) IP-20G


FibeAir IP-20C
Compact All-Outdoor Aggregation Node
Multi-Core Up to 5 RFUs
IP-20G

IP-20N
Fiber
1RU
IP-20C IP-20N Aggregation
1RU
Network
IP-20C IP-20N 2RU
Tail/Edge Node IP-20N 1RU
Core Network
IP-20C

IP-20S IP-20S FibeAir IP-20N


2RU Modular Chassis

IP-20G
FibeAir IP-20S
Compact All-Outdoor IP-20G
Multi-Core IP-20G IP-20G
Aggregation Node
Up to 10 RFUs
FibeAir IP-20G Full redundancy
1RU Fixed Design, Cascadable

IP-20S IP-20G

Tail Node Edge Node 16


Proprietary and Confidential
Overview

Proprietary and Confidential 17


FibeAir IP-20N – 2RU chassis
Fans tray
2 x Slots for
power distribution
cards (PDC)

Filter tray
(optional)

11 12 50
7 8 9 10
3 4 5 6
1 2 51
2 x Slots for 10 x Universal slots for:
main traffic and control - Radio interface cards (RMC)
cards (TCC)
- Ethernet line cards (4x GE)
- TDM line cards (16x E1, 1x ch-STM1)

Proprietary and Confidential 18


FibeAir IP-20N – 1RU chassis
Fans tray
1 x Slot for
Filter tray power distribution
(optional) card (PDC)
Single or dual feed

3 4 5 6
1 2 51
1 x Slot for 5 x Universal slots for:
Main traffic and control
card (TCC)
- Radio interface cards (RMC, RIC)
- Ethernet line cards (4x 1GE, 1x 10GE)
- TDM line cards (16x E1, 1x ch-STM1)

Proprietary and Confidential 19


Slots Numbering
From Bottom Left to Right and Up

3 4 5 6
1 2 51

11 12 50
7 8 9 10
3 4 5 6
1 2 51

Proprietary and Confidential


FibeAir IP-20N redundancy options
• Traffic/control card (TCC) redundancy option (2RU only)

• Radio modem/interface cards (RMC) redundancy


• 1+1/2+2 HSB
• N+0 Multi-carrier ABC

• Ethernet interfaces
• Ethernet Interface redundancy using LAG
• On the TCC or extra slots.

• TDM interfaces
• 1x ch-STM1 card – full card and interface redundancy option (1+1 MSP)

• Power supply
• Fully distributed power supply architecture
• Dual power-feed

• Fan redundancy – sustained operation with single fan failure

Proprietary and Confidential 21


Card types allowed per slot
1 RU
Slot
Allowed Card Type
Number
1 • TCC
NOTE:

• 2 x GE interfaces on the TCC-B-MC


• RMC-A, RMC-B or 6 x GE interfaces on the TCC-B2
or TCC-B2-XG-MC, and 4 x GE
• Ethernet LIC interfaces on the Ethernet LIC, for a
2
• TDM LIC total of 6 or 10 GE interfaces per
chassis.
• {Does not include LIC-STM1/OC3-RST (1 x STM1/OC-3)}
• When a second Ethernet LIC is
installed, two GE interfaces on the
TCC-B or TCC-B-MC are disabled,
leaving a total of 8 GE interfaces
• RMC-A, RMC-B, RMC-E per chassis.
• TDM LIC
3-6
• {Where Multi-Carrier ABC is used, slot 3 can be unoccupied or must be populated with an
RMC, which must be part of the Multi-Carrier ABC group}

Proprietary and Confidential 22


Card types allowed per slot
2 RU
Slot Allowed Card Type
Number
1 TCC
NOTE:
2,12 • RMC
When using a TCC-B2 or TCC-B2-XG-
• Ethernet – LIC-X-E4-Elec (4x GbE)
MC, four GE interfaces on the TCC
• Ethernet – LIC-X-E4-Opt (4x GbE) are disabled, leaving a total of 10 GE
interfaces per chassis.
• TDM – LIC-T16 (16x E1)
• TDM – LIC-T155 (1x ch-STM-1)

3 - 10 • RMC
• TDM – LIC-T16 (16x E1)
• TDM – LIC-T155 (1x ch-STM-1)
• TDM – LIC-STM1/OC3-RST

11 TCC

Proprietary and Confidential 23


Adjacent Pair Guidelines
Place the same type of cards in adjacent pairs, as follows:
• Slots 3 and 4
• Slots 5 and 6
• Slots 7 and 8 (2RU only)
• Slots 9 and 10 (2RU only)

Reason - for certain features, connectivity is supported in the backplane between these slot pairs.
• E.G: 2+2 HSB SD with XPIC: user must configure the radio protection group in non-adjacent channels, e.g., slots 3 and 5 or slots 4 and 6

Reason - XPIC groups must be in adjacent slots. 2+0 XPIC configuration is not available for RMCs in slots 2 and 12. A
valid combination would be:
• XPIC Group #1: Slot 3 and 4
• XPIC Group #2: Slot 5 and 6
• Radio Protection Group #1: Slot 3 and 5 (recommendation for leaving XPIC slots available)
• Radio Protection Group #2: Slot 4 and 6 (recommendation for leaving XPIC slots available)

For TCC-B2-XG-MC (in 2.5 Gbps ) these 4 slots can only be used by RMC-B and LIC-STM1/OC3-RST cards that belong
to a MC ABC group:
• 1RU chassis – Slots 3, 4, 5, and 6.
• 2RU chassis – Slots 3, 4, 7, and 8.

Proprietary and Confidential 24


Traffic – Ethernet Matrix
TCC Slot 11 Slot 12

Slot 7 Slot 8 Slot 9 Slot 10

Slot 3 Slot 4 Slot 5 Slot 6

SGMII to primary TCC


TCC Slot 1 Slot 2 SGMII to back-up TCC

Proprietary and Confidential 25


Supported Configuration
Configuration Special Requirements Configuration Instructions
1+0 and 1+0 IF combining  For IF Combining Requires RMC-B and 1500HP 1+0 Link, Quick Configuration Wizard

2+0 Single/Dual Polarization - XPIC Requires Multi-Carrier ABC or LAG.  


N(<=8)+0 Single Polarization or Dual Polarization XPIC Requires Multi-Carrier ABC or LAG.  
4, 6, 8+0 IF Combining / IF combining and XPIC Requires Multi-Carrier ABC and 1500HP.  
NOTES:
4+0 IF Combining and XPIC Requires Multi-Carrier ABC and 1500HP.   • Multi-Carrier ABC configurations require
TCC-B-MC or TCC-B2-XG-MC, and RMC-
1+1 HSB Protection Not on Evolution IP20 LH Systems  HSB Radio Protection B.
1+1 HSB Protection with BBS Space Diversity Requires Multi-Carrier ABC MC-ABC, Link Aggregation (LAG) • With TCC-B-MC, one Multi-Carrier ABC
group can be configured per unit with up to
2+2 HSB Protection Requires Multi-Carrier ABC MC-ABC, XPIC, Link Aggregation (LAG)
8 carriers aggregated in the group.
2+2 HSB Protection with BBS Space Diversity Requires Multi-Carrier ABC MC-ABC, IF Combining • With TCC-B2-XG-MC, up to four Multi-
2+2 HSB Protection with XPIC Requires Multi-Carrier ABC MC-ABC, IF Combining, XPIC Carrier ABC groups can be configured per
unit.
2+2 HSB Protection with BBS Space Diversity and XPIC Requires Multi-Carrier ABC HSB Radio Protection • Multi-Carrier ABC configurations can be
combined with non-Multi-Carrier ABC
2+2 HSB Protection with IF Combining and XPIC Requires Multi-Carrier ABC and 1500HP HSB Radio Protection, MC-ABC
configurations in the same unit. For
2 X 2+0 Multi-Carrier ABC Requires TCC-B2-XG-MC, RMC-B, and Multi-Carrier HSB Radio Protection, MC-ABC example, a single IP-20N unit can support
ABC a 4+0 Multi-Carrier ABC group and, in
Requires TCC-B2-XG-MC, RMC-B, and Multi-Carrier addition, an N+0 or a 1+1 HSB protection
4 X 2+0 Multi Carrier ABC ABC HSB Radio Protection, MC-ABC
group that is not part of the Multi-Carrier
Requires TCC-B2-XG-MC, RMC-B, and Multi-Carrier ABC group.
2 X 1+1 HSB-SD HSB Radio Protection, MC-ABC, XPIC
ABC
4 X 1+1 HSB-SD Requires TCC-B2-XG-MC, RMC-B, and Multi-Carrier HSB Radio Protection, MC-ABC, XPIC
ABC
Requires TCC-B2-XG-MC, RMC-B, and Multi-Carrier HSB Radio Protection, MC-ABC, IF
2 X 4+0 Multi-Carrier ABC
ABC Combining, XPIC

Proprietary and Confidential 26


Traffic Control Card - TCC

Proprietary and Confidential 27


Traffic Control Card - TCC 11

Main Functions: 1

• Provides the main CPU for the IP-20N chassis


• Responsible for chassis management
• Responsible for switch aggregation
• Responsible for synchronization in the IP-20N chassis

• TCC-B & TCC-B2 – do not support MC-ABC


• TCC-B-MC & TCC-B2-XG-MC - MC-ABC configurations, HSB BBS SD support:
• 1x Up to 8+0 MC-ABC (Up to 1Gbps)
• 1+1/2+2 MC-ABC/HSB (Up to 1Gbps)
• Mixed Nx1+0/1+1 & 1x ABC (4+0)

• Switching capacity: 10 Gbps


• 6,25 Mpps (Mega packet per second) switching capacity
• Shelf control and management

Ceragon approved SD cards
Ethernet traffic management and switching
with Cera OS
• Clock unit
Industrial Class6 1GB

Proprietary and Confidential


TCC connections 9
12
7 8 10
3 4 5 6
2

MNG Port
MNG port 1 1

MNG Port 2
CPU
1Gb SGMII / (2.5Gb)
Radio Card

10Gbps

1Gb SGMII / (2.5Gb)

Line Interface 1 Gb SGMII / 2.5 Gb 1Gb SGMII / (2.5Gb)


Ethernet Card
1Gb SGMII / (2.5Gb)
Line Interface 1 Gb SGMII / 2.5 Gb
1Gb SGMII / (2.5Gb)

Proprietary and Confidential 29


TCC- B & TCC-B-MC - Ports Description 11

1
Handle

Combo Ports
NOTES:

When a second Ethernet LIC is


installed, the two GbE interfaces on
the TCC-B or TCC-B-MC are
disabled, leaving a total of 8 GbE
interfaces per chassis.
Serial Port

Handle

Proprietary and Confidential 30


TCC- B2 & TCC-B2-XG-MC - Ports Description 11

Eth 1

Traffic or Handle
Handle
cascadin
g for
Hybrid
NOTES:
When using a TCC-B2 or TCC-B2-
XG-MC, you should avoid placing
any type of traffic cards (Ethernet
LIC, TDM LIC, and RMC) in certain
slots.
If you place a traffic card in one of
Serial Port these slots, some interfaces on the
TCC-B2 or TCC-B2-XGMC cannot
be used, table below.

Traffic Card in Slot: TCC-B2/TCC-B2-XG-MC Interfaces not Available for Use:


9 GbE5
10 GbE6
Ethernet LIC in Slot 12: SFP1, SFP2, GbE3/CS3, GbE4/CS4
12 TDM LIC or RMC in Slot 12: GbE3/CS3 only

Proprietary and Confidential 31


TCC Cards – Interfaces pin out

Proprietary and Confidential 32


TCC-B vs TCC-B2 vs TCC-B-MC vs TCC-B2-XG-MC

TCC Part No. Ethernet Traffic Interfaces Ethernet Management Interfaces Sync Ext Supports Multi-Carrier ABC
Interface Alarms
Type
TCC-B 24-T002-0 2 x GbE combo (optical or electrical) 2 x FE interfaces Yes Yes No
interfaces

TCC-B-MC 24-T004-0 2 x GbE combo (optical or electrical) 2 x FE interfaces Yes Yes Supports single Multi-Carrier ABC group
interfaces of up to 1 Gbps (8+0)

TCC-B2 24-T001-0 2 x GbE electrical interfaces 2 x FE interfaces, which connect to a single Yes Yes No
2 x GbE optical interfaces RJ-45 physical connector on the front
2 x dual mode electrical or cascading panel
interfaces

TCC-B2-XG-MC 24-T005-1 2 x GbE electrical interfaces 2 x FE interfaces, which connect to a single Yes Yes • From CeraOS 8.2.5, supports single
2 x GbE optical interfaces RJ-45 physical connector on the front Multi-Carrier ABC group and non MC-
2 x Dual Mode electrical or cascading panel ABC on the same unit: 1 x 8+0 MC-
interfaces ABC or 2.5Gbps
• From CeraOS 8.3.7, also supports
multiple Multi-Carrier ABC groups of
up to 1 Gbps per group.

Proprietary and Confidential 33


Ethernet Management of TCCs
• TCC-B and TCC-B-MC contain two GbE Ethernet interfaces and two FE interfaces for management.
MGMT 1 and 2.

• TCC-B2 and TCC-B2-XG-MC contain two FE management interfaces, which connect to a single RJ-45
physical connector on the front panel (MGMT) – special 2xFE cable to be ordered for both ports.

SPL-ETH-CBL Ethernet split cable rohs WA-0245-0

Proprietary and Confidential 34


IP-20N - No-Single-Point-of-Failure Architecture
• IP-20N - 2RU can have 2 TCCs for TCC redundancy
• Full support Hot Switchover (HSO) is available for all TCC models. HSO takes place
with no unit reset and a minimal traffic disruption.
• TCC Redundancy & Radio redundancy, PDC, Ethernet and TDM redundancy
• In redundant mode, TCCs share configuration and status information via internal
management channels, both TCCs have access to IVM for activation key information,
MAC addresses and serial numbers.
• TCC switchover automatically or manually.
• 3 Ethernet interface protection options:
• Ethernet Line Protection Mode – external switch needed.
• Optical Splitter Mode - Y optical cable needed on both active and standby Eth Ports.
• Electrical Splitter Mod – Y electrical cable needed on both active and standby Eth Ports. (Fast Ethernet
speeds only) – PN: WA-0244-0

• Y cable used for T3 synchronization input on TCCs and Management. T4 sync is not
supported in TCC redundancy mode.
Proprietary and Confidential 35
Radio Modem Cards - RMCs

Proprietary and Confidential 36


Radio Modem Cards (RMCs) 7 8 9
12
10
3 4 5 6
2

RMC A RMC B RMC E


• RMC-A
XPIC No Yes
• Based on Ceragon’s well known SoC modem
Multi-Carrier ABC No Yes Yes
• Supports up to 256QAM with ACM Modulation 256 2048 1024
QAM + QAM QAM +
• FibeAir IP-10G & IP10 E Series support across a link ACM RFU + ACM
ACM
• RMC-B FD and SD Yes Yes Yes
• Ceragon’s proprietary modem with ACM IP20
communication
Yes No No
• Supports up to 2048 QAM, XPIC and non XPIC (same Hardware) with IP10 across a
link
• Supports Header De-Duplication

• RMC-E
• For Evolution Transceivers
• Up to 1024 QAM with ACM
• Can include STM1-RST port

Proprietary and Confidential


Radio Modem Cards (RMC-E) 7 8 9 10
3 4 5 6

• Not for slots 2 and 12

• Only Evolution IP-20 LH systems

Proprietary and Confidential 38


RMC Indicators and Connectors 7 8 9
12
10
3 4 5 6
IF Connector 2

Handle Handle

ACT LINK RFU


LED LED LED

Color ACT LINK RFU


off No power No power No power
green OK, active mode Link OK no alarms RFU is OK

yellow OK, standby mode Minor or warning alarm Minor or warning alarm

red failure Critical or major alarm Critical or major alarm

Proprietary and Confidential 39


Ethernet Line Interface Cards – E-LICs

Proprietary and Confidential 40


Ethernet Line Interface Cards 12

LIC-XE4-Electrical LIC-X-E4-Opt (4x GbE) 2

• 1 GbE combo interface • 1 GbE combo interface


• 1 GbE electrical (RJ-45) interface • 1 GbE optical (SFP) interface
• 2 dual mode electrical/cascading • 2 dual mode optical/cascading
interfaces interfaces
• Only in slots 2(1RU) or 2 & 12 • Only in slots 2(1RU) or 2 & 12
• MDI/MDIX support • MDI/MDIX support
• Cascading ports (port 3 & 4) • Cascading ports (port 3 & 4)

Proprietary and Confidential 41


LIC-X-E4-Elec & LIC-X-E4-Opt 12

2
Gigabit Electrical Ports Gigabit Optical Ports

Handle Handle

ACT ACT Elect LEDs SFP


SFP SFP
LED Slot LED LED Gigabit LED
Electrical port

Color ACT Left LED for port Right LED for port SFP LED

Interface is disabled or Cable not connected, link


off No power Interface is disabled the interface operates at
100BaseT mode
not ok, interface is
disabled

Interface operates at
the interface is enabled Interface is enabled and
green OK, no alarms and link is OK (Blinking =
traffic activity)
1000BaseT mode,
Blinking means operates link is OK, blinking means
traffic activity
at 10BaseT mode

red Card failure or hardware


failure
--------------------------- --------------------------- ----------------------------

Proprietary and Confidential 42


TDM Line Interface Cards

Proprietary and Confidential 43


TDM Line Interface Cards 7 8 9
12
10
3 4 5 6
2

Available TDM Line Cards


• LIC-T16 and LIC-T155 cards can be placed in any slot (no TCC or PDC)
• LIC-STM1/OC3-RST cards cannot be used in 2 or 2&12 (d. chassis)
LIC-T16 (16 x E1) LIC-T155 (1 x ch-STM-1) LIC-STM1/OC3-RST (1 x STM-1)

Proprietary and Confidential 44


TDM Line Interface Cards 7 8 9
12
10
3 4 5 6
2

This card is also


available without
SYNC port

Color ACT Sync Left LED for Sync Right LED for E1/DS1 LED STM1/OC3
port port

The interface is
off No power disabled or no signal is The interface is The interface is The interface is
being received disabled disabled disabled

Indicates whether a valid Indicates whether the


green OK, no alarms signal is being received interface is configured to No alarms No alarms
when enabled export a clock

Card failure or
red hardware failure --------------------------- --------------------------- Any alarms Any alarms

Proprietary and Confidential


LIC-T16 (16xE1) Connector and Sync Interface 7 8 9
12
10
3 4 5 6
2

Proprietary and Confidential 46


TDM LIC-T155 (1 x ch-STM-1) 7 8 9
12
10
3 4 5 6
2

Proprietary and Confidential 47


TDM LIC-STM-1/OC3-RST 7 8 9 10
3 4 5 6

Proprietary and Confidential 48


Inventory Module - IVM

Proprietary and Confidential 49


Mandatory Cards – Inventory Module
• Single card for 1RU and 2RU chassis.
• 2 x EEPROM on single board (function as 2 separated cards).
• Installed at the back of the chassis
• Holds the chassis:
• License.
• Node MAC address (48 MACs per unit).
• Serial number.

Proprietary and Confidential 50


Inventory Module - IVM
• The IVM contains pre-programmed information that defines chassis & slots:
• Module/Card types that go into the chassis, per slot
• Product and card names
• Internal MAC addresses
• Serial number
• Hardware versions
• Activation keys code for activated features and capacities

• The IVM stores information in a 8 KB (64 kb) EEPROM. A 2RU IP-20N IVM contains two EEPROMs.
If a redundant TCC configuration is used, each EEPROM is dedicated to a specific TCC
IVM

EEPROM EEPROM
TCC 2 TCC 1

Proprietary and Confidential 51


Power Distribution Card

Proprietary and Confidential 52


Power Distribution Cards - PDCs 52

51

IP-20N receives a supply of -48V current via 1 or 2 Power Distribution Cards. Functions:
• Distributes power via the backplane to rest of modules
• Gets -48V signal and regulates it down for other cards.
• RFUs are powered from the PDC, via the RMC
Du
al-
Si po Inp
ng w e ut
le r r PD
In ed C
p ut
PD un –
da 1 R
C nc U
-2 y
RU

-40  -60 V, 30A

Proprietary and Confidential 53


Power Distribution Cards 52

51

• LED is red for under/over powered & green for normal operation
• Reversed polarity protection + -
• A diode bridge in the modules prevents power spikes and unstable power from the two power
sources.
• The power source must be grounded

Single/Standard Input PDC Interface Dual Input PDC Interface

Proprietary and Confidential 54


Power consumption specifications
Card Type/Configuration Power (W) Comments
TCC 25W  
RMC 17W  
LIC-X-E4-Elec (4x GbE) 9W  
LIC-X-E4-Opt (4x GbE) 9W  
LIC-T16 (16x E1) 17W  
LIC-T155 (1x ch-STM-1) 25W  
LIC-STM1/OC3-RST (1 x STM-1) 9W  

Fan – 2RU Chassis 30W max (6W typical at 25°C) Kinetic energy.

Fan – 1RU Chassis 6W max (4W typical at 25°C) Kinetic energy.


Max Bias: 85W
1500HP Min Bias: 72W RFU only
Mute: 29W
Max Bias: 73W
6-8 GHz Mid Bias: 48W
Min Bias: 34W
RFU-HP Mute: 18W RFU only
Max Bias: 74W
11 GHz Min Bias: 64W
Mute: 21W
6-26 GHz 1+0: 22 RFU only.
1+1: 39
RFU-C
28-42 GHz 1+0: 26 RFU only.
1+1: 43
Proprietary and Confidential 55
Fans Module & Air Filter

Proprietary and Confidential 56


Mandatory Cards – Fans
• 4 fans -48VDC inside the module, powered from the backplane, PDC
• Different module for 1RU and 2RU chassis

Fa Fa
ns ns
f fo
or r1
2R RU
U ch
ch as
as sis
sis

Proprietary and Confidential 57


Filter Tray – optional card
• IP-20N offers a filter as optional equipment. If a filter tray is not ordered, the IP-20N chassis is
delivered with a blank filter slot cover.

Proprietary and Confidential 58


IP-20N Block diagram

Proprietary and Confidential 59


Chassis Management

• IP-20N implements internal chassis


2RU Chassis – Up to 10 RMCs/LICs
1RU Chassis – Up to 5 RMCs/LICs
(Any Combination)

management via a dedicated


channel between the TCCs and
each slot in the chassis, including RMC-D / RMC-S / LIC
RMC-D/RMC-S
TCC 1
the PDCs and the FAN slots. TCC 2 (in 2RU
High Availability
Backplane
RMC-D/RMC-S
RMC or LIC
node)

FAN Tray

PDC (2 x PDC
option in 2RU
chassis).

Control lines for PDC and FAN Tray.


Black – TCC 1
Green – TCC 2

Proprietary and Confidential


System Backplane
TDM Sync Ethernet MC-ABC

Block Diagram 1RU 48V PDC RMC

Framer Modem IF
Power Supply

RFU
RFU
TCC
Interface

Power Supply XPIC

Sync
In/Out Sync Unit RFU
Framer Modem IF RFU
Interface
FE Management
Interfaces (1 or 2)
CPU
Terminal Power Supply
Ethernet RMC
GE Traffic Ethernet Services
Interfaces Network
(2 to 6) Processor
STM-1 RST
Services Line Card
Engine STM-1 RST
Native TDM Service
TDM Cross Services STM-1 Interface
Connect

Multi-Carrier Power Supply

ABC Engine

E1 Line Card
TDM Pseudowire
Services
TDM
16 x E1
Services Framer LIU
Interface
Processor

1588 OC/BC PPS


(Optional) ToO

Power Supply

TDM Pseudowire
ch-STM-1 Line Card
Services
TDM
STM-1
Services Framer LIU
Interface
Processor

1588 OC/BC PPS


(Optional) ToO

Power Supply

Ethernet Line Card


Ethernet Line Interface

Ethernet Line Interface

Ethernet Line Interface

Ethernet Line Interface

Power Supply

Proprietary and Confidential 61


System Backplane
TDM Sync Ethernet MC-ABC

Block Diagram 2RU


48V PDC 1 RMC Power Supply

RFU
Framer Modem IF RFU

TCC & PDC Redundancy


TCC 1
Interface

Power Supply XPIC

Sync
In/Out Sync Unit RFU
Framer Modem IF RFU
Interface
FE Management
Interfaces (1 or 2)
CPU
Terminal Power Supply
Ethernet RMC
GE Traffic Ethernet Services
Interfaces Network
(2 to 6) Processor
STM-1 RST
Services Line Card
Engine STM-1 RST
Native TDM Service
TDM Cross Services STM-1 Interface
Connect

Multi-Carrier Power Supply

ABC Engine

E1 Line Card
TCC 2 TDM Pseudowire
Services
(Optional) TDM
Services Framer LIU
16 x E1
Interface
Processor
Power Supply

Sync
1588 OC/BC PPS
In/Out Sync Unit (Optional) ToO

FE Management Power Supply


Interfaces (1 or 2)
CPU
Terminal
Ethernet

GE Traffic
Ethernet Services
TDM Pseudowire
ch-STM-1 Line Card
Interfaces Network Services
TDM
(2 to 6) Processor Services Framer LIU
STM-1
Interface
Processor

Services
1588 OC/BC PPS
Engine
Native TDM
(Optional) ToO
TDM Cross Services
Power Supply
Connect

Multi-Carrier Ethernet Line Card


ABC Engine
Ethernet Line Interface

Ethernet Line Interface

Ethernet Line Interface

48V
PDC 2
(Optional) Ethernet Line Interface

Power Supply

Proprietary and Confidential 62


Front Panel Overview

Proprietary and Confidential 63


What was discussed
 IP-20N Product Highlights

 Network topology with IP-20N

 IP-20N Overview
 1U and 2U chassis
 TCC – Traffic Control Card
 RMC – Radio Modem Cards
 ELIC – Ethernet Line Interface Cards & TDM Line cards
 IVM – Inventory Module
 PDC – Power Distribution Card & Fan Module and Air Filter
 RFU – Radio Frequency Units

 IP-20N Block Diagram

Proprietary and Confidential 66


Thank You

Proprietary and Confidential

You might also like