Professional Documents
Culture Documents
Polarizer Installation
Update : 2 Apr 2010
Page
3
1. Hardware Parts (Polarizer)
4
2. Machine Setup
5
3. Pre Bond Substrate Inspection (Lighting)
6
4. Pre buyoff Sample 1 (Result)
7
5. Pre buyoff Sample 2 (Result)
8
6. Problem Facing
9
7. Software Issue
10
8. Action taken
Project Updates 2
Hardware Parts (Polarizer)
Project Updates 3
Machine Setup
Machine Setup:
i. Pre bond Substrate Failure Handling
select “Stop”.
ii. Num of Insp.Win select “4”.
iii. Defect Threshold select “Very Tight”.
iv. Diff. Lighting select “Different”
Project Updates 4
Pre Bond Substrate Inspection (Lighting)
Inspection region 4
Coaxial light 40%
Ring light 40%
Exposure 8%
Project Updates 5
Pre buyoff Sample 1 (Result)
Project Updates 6
Pre buyoff Sample 2 (Result)
Project Updates 7
Problem Facing
Problem Facing
~ Some unit the extra glue can’t detect
Project Updates 8
Software Issue
Software Issue
V2.24.18E & V3.20.06 Wineagle
Defect Threshold – Very Tight can’t be trigger
It occupy by Pre bond Substrate Failure Handling
Project Updates 9
Action Taken
Action Taken:
Log file sent to AAA Vision group (Hong Kong) for study
Defect Threshold – “Very Tight” can be Trigger
Project Updates 10
Thank you for your attention.