“ IS CHANCES OF ECONOMISER TUBE STARVATION IN BOILER- DESCRIBE ”
Youtube.com/@AtharvaOnlineStudyCentre Make in India IS CHANCE OF ECONOMISER TUBE STARVATION
Starvation may occur during the start-up of
boiler from cold condition.
there will not be any flow from the economiser
tubes till substantial amount of continuous steam generation starts in the boiler.
This leads to the water in economiser tubes
get evaporated and move out of tubes thereby resulting in starvation. IS CHANCE OF ECONOMISER TUBE STARVATION
To prevent this, the boilers will have a
economiser recirculation system. In this a tapping from the downcomer with the NRV end isolating valve will be connected to economizer inlet. IS CHANCE OF ECONOMISER TUBE STARVATION
Keeping this line open during light-up ensures
circulation of water through the economiser thereby avoiding starvation.
This re-circulation line must be closed once